Test report

FCC ID: K4E266CQ

Test Report

Download: PDF
FCCID_3939068

                             Global United Technology Services Co., Ltd.

                                                                                  Report No.: GTS201806000203F01



                                       FCC REPORT
    Applicant:                        Superior Electronics Corporation

    Address of Applicant:             No. 10 Lane 31, Chongde St., Sinyi District, Taipei City, Taiwan

    Manufacturer/Factory:             Superior Electronics Corporation

    Address of                        No. 10 Lane 31, Chongde St., Sinyi District, Taipei City, Taiwan
    Manufacturer/Factory:
    Equipment Under Test (EUT)

      Product Name:                   Wireless video doorphone
      Model No:                       DP-266-CQ
    FCC ID:                           K4E266CQ
    Applicable standards:             FCC CFR Title 47 Part 15 Subpart C Section 15.249

    Date of sample receipt:           June 20, 2018

    Date of Test:                     June 28-29, 2018

    Date of report issued:            July 03, 2018

    Test Result :                     PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




      Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.


                                                                               Report No.: GTS201806000203F01


2      Version
           Version No.                                  Date                            Description
                 0.0                               July 03, 2018                          Original




Prepared By:                                                       Date:                 July 03, 2018

                                     Project Engineer



Check By:                                                          Date:                 July 03, 2018

                                          Reviewer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 2 of 42


                                                                                                            Report No.: GTS201806000203F01


3         Contents
                                                                                                                                                           Page
1     COVER PAGE ............................................................................................................................................ 1

2      VERSION .................................................................................................................................................. 2

3      CONTENTS .............................................................................................................................................. 3

4      TEST SUMMARY ..................................................................................................................................... 4
    4.1        MEASUREMENT UNCERTAINTY ............................................................................................................ 4
5      GENERAL INFORMATION ...................................................................................................................... 5
    5.1        GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.2        TEST MODE ........................................................................................................................................ 7
    5.3        DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7
    5.4        TEST FACILITY.................................................................................................................................... 7
    5.5        TEST LOCATION ................................................................................................................................. 7
    5.6        OTHER INFORMATION REQUESTED BY THE CUSTOMER ......................................................................... 7
    5.7        ADDITIONAL INSTRUCTIONS ................................................................................................................. 7
6      TEST INSTRUMENTS LIST ..................................................................................................................... 8

7      TEST RESULTS AND MEASUREMENT DATA.................................................................................... 10
    7.1     ANTENNA REQUIREMENT ................................................................................................................... 10
    7.2     CONDUCTED EMISSIONS ................................................................................................................... 11
    7.3     RADIATED EMISSION METHOD ........................................................................................................... 14
       7.3.1 Field Strength of The Fundamental Signal ................................................................................ 16
       7.3.2 Spurious emissions .................................................................................................................... 18
       7.3.3 Bandedge emissions.................................................................................................................. 23
    7.4     20DB OCCUPY BANDWIDTH .............................................................................................................. 27
8      TEST SETUP PHOTO ............................................................................................................................ 29

9      EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 31




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                     Page 3 of 42


                                                                               Report No.: GTS201806000203F01


4      Test Summary
                 Test Item                             Section in CFR 47                     Result
          Antenna requirement                                 15.203                          Pass
    AC Power Line Conducted Emission                          15.207                          Pass
Field strength of the fundamental signal                    15.249 (a)                        Pass
           Spurious emissions                         15.249 (a) (d)/15.209                   Pass
                Band edge                               15.249 (d)/15.205                     Pass
        20dB Occupied Bandwidth                             15.215 (c)                        Pass
Pass: The EUT complies with the essential requirements in the standard.
Remark: Test according to ANSI C63.10: 2013.


4.1 Measurement Uncertainty
            Test Item                      Frequency Range                Measurement Uncertainty       Notes
        Radiated Emission                     9kHz ~ 30MHz                        ± 4.34dB               (1)
        Radiated Emission                  30MHz ~ 1000MHz                        ± 4.24dB               (1)
        Radiated Emission                   1GHz ~ 26.5GHz                        ± 4.68dB               (1)
    AC Power Line Conducted
                                            0.15MHz ~ 30MHz                       ± 3.45dB               (1)
          Emission
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 4 of 42


                                                                               Report No.: GTS201806000203F01


5      General Information
5.1 General Description of EUT

      Product Name:                      Wireless video doorphone
      Model No.:                         DP-266-CQ
      Test sample(s) ID:                 GTS201806000203-1
      Sample(s) Status                   Engineer sample
      Hardware:                          TP35-70-Out-Ver:1.1
      Software:                          ENFORCER-S V2.2.3
      Operation Frequency:               2406MHz~2480MHz
      Channel numbers:                   16
      Modulation type:                   GFSK
      Antenna Type:                      Integral Antenna
      Antenna gain:                      0dBi(Max)
      Power supply:                      AC/DC Adapter
                                         Model: BSG-0501000
                                         Input: AC 100V-240V, 50/60Hz
                                         Output: DC 5V,1A
                                         3.7 Vdc (Li-ON battery)




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 5 of 42


                                                                                 Report No.: GTS201806000203F01




Operation Frequency each of channel
 Channel     Frequency   Channel    Frequency                 Channel          Frequency   Channel        Frequency
    01          2406MHz            05         2420MHz            09            2445MHz       13           2466MHz
    02          2410MHz            06         2428MHz            10            2452MHz       14           2470MHz
    03          2412MHz            07         2435MHz            11            2456MHz       15           2476MHz
    04          2415MHz            08         2440MHz            12            2459MHz       16           2480MHz




Note:
In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
middle frequency, and the highest frequency of channel were selected to perform the test, and the selected
channel see below:
         Channel                        Frequency

   The lowest channel                   2406MHz

   The middle channel                   2440MHz

  The Highest channel                   2480MHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 6 of 42


                                                                                Report No.: GTS201806000203F01




5.2 Test mode
       Transmitting mode                    Keep the EUT in continuously transmitting mode.
       Remark: During the test, the test voltage was tuned from 85% to 115% of the nominal rated
       supply voltage, and found that the worst case was under the nominal rated supply condition. So
       the report just shows that condition’s data.
Per-test mode.
We have verified the construction and function in typical operation, The EUT was placed on three
different polar directions; i.e. X axis, Y axis, Z axis. only worse case is reported:
            Axis                            X                             Y                         Z
  Field Strength(dBuV/m)                 97.65                          98.93                    97.81
5.3 Description of Support Units
       None.

5.4 Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ● FCC —Registration No.: 381383
       Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fuly
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in files. Registration 381383, January 08, 2018.
       ● Industry Canada (IC) —Registration No.: 9079A-2
       The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
       Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
       No.: 9079A-2, August 15, 2016
5.5 Test Location
       All tests were performed at:
       Global United Technology Services Co., Ltd.
       Address: No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road,
       Baoan District, Shenzhen, Guangdong, China 518102
       Tel: 0755-27798480
       Fax: 0755-27798960
5.6 Other Information Requested by the Customer
       None.
5.7 Additional instructions
Power level setup in software
Test Software Name                  KDB302A
Test Software Version               ENFORCER-V1.1.0
Support Units                           Description                   Manufacturer                Model
(Software installation media)          Notebook PC                      Lenovo                    E40-80
Mode                                     Channel                    Frequency (MHz)               Soft Set
GFSK                                         CH01                          2406
                                             CH08                          2440             TX level: Default
                                             CH16                          2480

Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 7 of 42


                                                                                Report No.: GTS201806000203F01


6        Test Instruments list
Radiated Emission:
                                                                               Inventory     Cal.Date        Cal.Due date
Item       Test Equipment          Manufacturer            Model No.
                                                                                  No.       (mm-dd-yy)       (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron    9.2(L)*6.2(W)* 6.4(H)     GTS250      July. 03 2015     July. 02 2020
             Chamber
 2          Control Room         ZhongYu Electron    6.2(L)*2.5(W)* 2.4(H)     GTS251          N/A               N/A
 3        EMI Test Receiver      Rohde & Schwarz            ESU26              GTS203      June. 27 2018     June. 26 2019
                                 SCHWARZBECK
 4       BiConiLog Antenna                                VULB9163             GTS214      June. 27 2018     June. 26 2019
                                MESS-ELEKTRONIK
       Double -ridged waveguide SCHWARZBECK
 5                                                       BBHA 9120 D           GTS208      June. 27 2018     June. 26 2019
                  horn         MESS-ELEKTRONIK
 6          Horn Antenna         ETS-LINDGREN                3160              GTS217      June. 27 2018     June. 26 2019
 7        EMI Test Software          AUDIX                    E3                 N/A           N/A               N/A
 8          Coaxial Cable              GTS                    N/A              GTS213      June. 27 2018     June. 26 2019
 9          Coaxial Cable              GTS                    N/A              GTS211      June. 27 2018     June. 26 2019
10          Coaxial cable              GTS                    N/A              GTS210      June. 27 2018     June. 26 2019
11          Coaxial Cable              GTS                    N/A              GTS212      June. 27 2018     June. 26 2019
12     Amplifier(100kHz-3GHz)          HP                   8347A              GTS204      June. 27 2018     June. 26 2019
13     Amplifier(2GHz-20GHz)           HP                   84722A             GTS206      June. 27 2018     June. 26 2019
                                                         AFS33-18002
14      Amplifier (18-26GHz)     Rohde & Schwarz                               GTS218      June. 27 2018     June. 26 2019
                                                         650-30-8P-44
15           Band filter            Amindeon                 82346             GTS219      June. 27 2018     June. 26 2019
16          Power Meter              Anritsu               ML2495A             GTS540      June. 27 2018     June. 26 2019
17          Power Sensor             Anritsu               MA2411B             GTS541      June. 27 2018     June. 26 2019
          Wideband Radio
18                               Rohde & Schwarz           CMW500              GTS575      June. 27 2018     June. 26 2019
        Communication Tester
19             Splitter              Agilent                11636B             GTS237      June. 27 2018     June. 26 2019
20          Loop Antenna             ZHINAN               ZN30900A             GTS534      June. 27 2018     June. 26 2019




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 8 of 42


                                                                               Report No.: GTS201806000203F01



Conducted Emission
                                                                               Inventory     Cal.Date      Cal.Due date
 Item          Test Equipment       Manufacturer            Model No.
                                                                                  No.       (mm-dd-yy)     (mm-dd-yy)
     1         Shielding Room     ZhongYu Electron    7.3(L)x3.1(W)x2.9(H)     GTS252      May.16 2014     May.15 2019
     2       EMI Test Receiver         R&S                   ESCI 7            GTS552      June. 27 2018   June. 26 2019
     3         Coaxial Switch     ANRITSU CORP               MP59B             GTS225      June. 27 2018   June. 26 2019
               Artificial Mains   SCHWARZBECK
     4                                                      NSLK8127           GTS226      June. 27 2018   June. 26 2019
                   Network           MESS
     5          Coaxial Cable          GTS                     N/A             GTS227      June. 27 2018   June. 26 2019
     6       EMI Test Software        AUDIX                     E3               N/A           N/A             N/A
     7         Thermo meter             KTJ                   TA328            GTS233      June. 27 2018   June. 26 2019


General used equipment:

                                                                               Inventory      Cal.Date      Cal.Due date
Item        Test Equipment        Manufacturer              Model No.
                                                                                  No.        (mm-dd-yy)     (mm-dd-yy)

              Humidity/
 1                                    KTJ                    TA328             GTS243      June. 27 2018   June. 26 2019
         Temperature Indicator

 2            Barometer           ChangChun                  DYM3              GTS255      June. 27 2018   June. 26 2019




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 9 of 42


                                                                                 Report No.: GTS201806000203F01


7      Test results and Measurement Data
7.1 Antenna requirement
      Standard requirement:           FCC Part15 C Section 15.203
      15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
       party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a
       unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can
       be replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
      EUT Antenna:

        The antenna is integral antenna, the best case gain of the antenna is 0dBi.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 10 of 42


                                                                                 Report No.: GTS201806000203F01


7.2 Conducted Emissions
      Test Requirement:                FCC Part15 C Section 15.207
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            150KHz to 30MHz
      Class / Severity:                Class B
      Receiver setup:                  RBW=9KHz, VBW=30KHz, Sweep time=auto
      Limit:                                                                            Limit (dBuV)
                                          Frequency range (MHz)
                                                                               Quasi-peak              Average
                                                  0.15-0.5                      66 to 56*              56 to 46*
                                                    0.5-5                          56                     46
                                                     5-30                          60                     50
                                       * Decreases with the logarithm of the frequency.
      Test setup:




      Test procedure:                  1. The EUT and simulators are connected to the main power through a
                                          line impedance stabilization network (L.I.S.N.). This provides a
                                          50ohm/50uH coupling impedance for the measuring equipment.
                                       2. The peripheral devices are also connected to the main power through a
                                          LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                          termination. (Please refer to the block diagram of the test setup and
                                          photographs).
                                       3. Both sides of A.C. line are checked for maximum conducted
                                          interference. In order to find the maximum emission, the relative
                                          positions of equipment and all of the interface cables must be changed
                                          according to ANSI C63.10: 2013 on conducted measurement.
      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 11 of 42


                                                                               Report No.: GTS201806000203F01


Measurement data
Line:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 12 of 42


                                                                               Report No.: GTS201806000203F01




Neutral:




Notes
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak
     emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss
4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet
   both limits and measurement with the average detector receiver is unnecessary.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 13 of 42


                                                                               Report No.: GTS201806000203F01




7.3 Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            9kHz to 25GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                       Frequency            Detector       RBW        VBW             Value
                                          9KHz-150KHz          PK/AV/QP         200Hz      600Hz      PK/AV/QP
                                         150KHz-30MHz          PK/AV/QP         9KHz       30KHz      PK/AV/QP
                                          30MHz-1GHz           Quasi-peak      120KHz     300KHz      Quasi-peak
                                                                   Peak         1MHz       3MHz            Peak
                                           Above 1GHz
                                                                   Peak         1MHz       10Hz           Average
      Limit:                                    Frequency               Limit (dBuV/m @3m)            Remark
      (Field strength of the                                                     94.00             Average Value
                                          2400MHz-2483.5MHz
      fundamental signal)                                                       114.00              Peak Value
      Limit:                                                                                        Measurement
                                               Frequency             Limit (uV/m)       Value
      (Spurious Emissions)                                                                           Distance
                                         0.009MHz-0.490MHz         2400/F(KHz)      PK/AV/QP           300m
                                         0.490MHz-1.705MHz         24000/F(KHz)        QP              300m
                                          1.705MHz-30MHz                30             QP              30m
                                            30MHz-88MHz                 100            QP
                                            88MHz-216MHz                150            QP
                                           216MHz-960MHz                200            QP
                                                                                                       3m
                                             960MHz-1GHz                500            QP
                                                                        500          Average
                                            Above 1GHz
                                                                       5000           Peak
      Limit:                           Emissions radiated outside of the specified frequency bands, except for
      (band edge)                      harmonics, shall be attenuated by at least 50 dB below the level of the
                                       fundamental or to the general radiated emission limits in Section 15.209,
                                       whichever is the lesser attenuation.
      Test setup:                      Below 30MHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 14 of 42


                                                                               Report No.: GTS201806000203F01


                                       Below 1GHz




                                       Above 1GHz




      Test Procedure:                  1.   The EUT was placed on the top of a rotating table (0.8m for below 1G
                                            and 1.5m for above 1G) above the ground at a 3 meter camber. The
                                            table was rotated 360 degrees to determine the position of the highest
                                            radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                          antenna, which was mounted on the top of a variable-height antenna
                                          tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                          ground to determine the maximum value of the field strength. Both
                                          horizontal and vertical polarizations of the antenna are set to make the
                                          measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                          and then the antenna was tuned to heights from 1 meter to 4 meters
                                          and the rota table was turned from 0 degrees to 360 degrees to find the
                                          maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and
                                          Specified Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the

Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 15 of 42


                                                                                Report No.: GTS201806000203F01


                                          limit specified, then testing could be stopped and the peak values of the
                                          EUT would be reported. Otherwise the emissions that did not have
                                          10dB margin would be re-tested one by one using peak, quasi-peak or
                                          average method as specified and then reported in a data sheet.
        Test Instruments:              Refer to section 6.0 for details
        Test mode:                     Refer to section 5.2 for details
        Test results:                  Pass


Measurement data:



7.3.1     Field Strength of The Fundamental Signal
Peak value:
                  Read        Antenna         Cable     Preamp                                   Over
 Frequency                                                             Level      Limit Line
                  Level        Factor         Loss       Factor                                  Limit      polarization
   (MHz)                                                             (dBuV/m)     (dBuV/m)
                 (dBuV)        (dB/m)          (dB)       (dB)                                   (dB)
  2406.00         88.87        27.58          5.39       30.18         91.66       114.00       -22.34        Vertical
  2406.00         96.14        27.58          5.39       30.18         98.93       114.00       -15.07      Horizontal
  2440.00         88.20        27.55          5.43       30.06         91.12       114.00       -22.88        Vertical
  2440.00         94.10        27.55          5.43       30.06         97.02       114.00       -16.98      Horizontal
  2480.00         88.12        27.52          5.47       29.93         91.18       114.00       -22.82        Vertical
  2480.00         94.19        27.52          5.47       29.93         97.25       114.00       -16.75      Horizontal
Average value:
                  Read        Antenna         Cable     Preamp                                   Over
 Frequency                                                             Level      Limit Line
                  Level        Factor         Loss       Factor                                  Limit      polarization
   (MHz)                                                             (dBuV/m)     (dBuV/m)
                 (dBuV)        (dB/m)          (dB)       (dB)                                   (dB)
  2406.00         77.33        27.58          5.39       30.18         80.12        94.00       -13.88        Vertical
  2406.00         82.34        27.58          5.39       30.18         85.13        94.00        -8.87      Horizontal
  2440.00         76.64        27.55          5.43       30.06         79.56        94.00       -14.44        Vertical
  2440.00         81.49        27.55          5.43       30.06         84.41        94.00        -9.59      Horizontal
  2480.00         76.89        27.52          5.47       29.93         79.95        94.00       -14.05        Vertical
  2480.00         81.22        27.52          5.47       29.93         84.28        94.00        -9.72      Horizontal



Note: For fundamental frequency ,RBW 5MHz VBW 5MHz ,Peak detector is for PK value , RMS detector is for
AV value



Test Read plot of worse case as follows:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 16 of 42


                                                                               Report No.: GTS201806000203F01



Worse case 2406MHz(Horizontal):




                                             Read level for peak value




                                           Read level for average value




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 17 of 42


                                                                               Report No.: GTS201806000203F01



7.3.2   Spurious emissions
   9 kHz ~ 30 MHz
The low frequency, which started from 9 kHz to 30 MHz, was pre-scanned and the result which was 20 dB
lower than the limit line per 15.31(o) was not reported.


   Below 1GHz
Horizontal:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 18 of 42


                                                                               Report No.: GTS201806000203F01

Vertical:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 19 of 42


                                                                               Report No.: GTS201806000203F01



     Above 1GHz
Test channel:                                          Lowest channel

Peak value:
                 Read        Antenna        Cable      Preamp                                    Over
Frequency                                                            Level      Limit Line
                 Level        Factor        Loss        Factor                                   Limit   polarization
  (MHz)                                                            (dBuV/m)     (dBuV/m)
                (dBuV)        (dB/m)        (dB)         (dB)                                    (dB)
    4812.00      63.61         31.22        4.61        37.73         61.71       74.00         -12.29        Vertical
    7218.00      52.03         36.20        6.50        35.63         59.10       74.00         -14.90        Vertical
    9624.00      45.65         37.93        7.98        34.94         56.62       74.00         -17.38        Vertical
 12030.00           *                                                             74.00                       Vertical
 14436.00           *                                                             74.00                       Vertical
    4812.00      65.96         31.22        4.61        37.73         64.06       74.00         -9.94        Horizontal
    7218.00      52.82         36.20        6.50        35.63         59.89       74.00         -14.11       Horizontal
    9624.00      46.10         37.93        7.98        34.94         57.07       74.00         -16.93       Horizontal
 12030.00           *                                                             74.00                      Horizontal
 14436.00       *                                                                 74.00                      Horizontal
Average value:
              Read           Antenna       Cable       Preamp                                    Over
Frequency                                                            Level      Limit Line
              Level           Factor       Loss        Factor                                    Limit   polarization
   (MHz)                                                           (dBuV/m)     (dBuV/m)
             (dBuV)           (dB/m)       (dB)          (dB)                                    (dB)
  4812.00     42.37            31.22       4.61         37.73        40.47        54.00         -13.53        Vertical
    7218.00      27.69         36.20        6.50        35.63        34.76        54.00         -19.24        Vertical
    9624.00      21.74         37.93        7.98        34.94        32.71        54.00         -21.29        Vertical
 12030.00          *                                                              54.00                       Vertical
 14436.00          *                                                              54.00                       Vertical
    4812.00      43.63         31.22        4.61        37.73        41.73        54.00         -12.27       Horizontal
    7218.00      28.88         36.20        6.50        35.63        35.95        54.00         -18.05       Horizontal
    9624.00      23.50         37.93        7.98        34.94        34.47        54.00         -19.53       Horizontal
 12030.00          *                                                              54.00                      Horizontal
 14436.00         *                                                             54.00                        Horizontal
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 20 of 42


                                                                               Report No.: GTS201806000203F01



Test channel:                                                Middle
Peak value:
                 Read        Antenna       Cable       Preamp                                    Over
Frequency                                                            Level      Limit Line
                 Level        Factor       Loss        Factor                                    Limit   polarization
  (MHz)                                                            (dBuV/m)     (dBuV/m)
                (dBuV)        (dB/m)       (dB)          (dB)                                    (dB)
  4880.00        63.76         31.31       4.69         37.75         62.01       74.00         -11.99        Vertical
  7320.00        52.13         36.43        6.63        35.60         59.59       74.00         -14.41        Vertical
  9760.00        45.74         38.10        8.03        35.03         56.84       74.00         -17.16        Vertical
 12200.00          *                                                              74.00                       Vertical
 14640.00          *                                                              74.00                       Vertical
  4880.00        66.14         31.31        4.69        37.75         64.39       74.00         -9.61        Horizontal
  7320.00        52.93         36.43        6.63        35.60         60.39       74.00         -13.61       Horizontal
  9760.00        46.21         38.10        8.03        35.03         57.31       74.00         -16.69       Horizontal
 12200.00          *                                                              74.00                      Horizontal
 14640.00       *                                                                 74.00                      Horizontal
Average value:
              Read           Antenna       Cable       Preamp                                    Over
Frequency                                                            Level      Limit Line
              Level           Factor       Loss        Factor                                    Limit   polarization
   (MHz)                                                           (dBuV/m)     (dBuV/m)
             (dBuV)           (dB/m)       (dB)          (dB)                                    (dB)
  4880.00     42.51            31.31       4.69         37.75         40.76       54.00         -13.24        Vertical
  7320.00        27.78         36.43        6.63        35.60         35.24       54.00         -18.76        Vertical
  9760.00        21.83         38.10        8.03        35.03         32.93       54.00         -21.07        Vertical
 12200.00          *                                                              54.00                       Vertical
 14640.00          *                                                              54.00                       Vertical
  4880.00        43.79         31.31        4.69        37.75         42.04       54.00         -11.96       Horizontal
  7320.00        28.98         36.43        6.63        35.60         36.44       54.00         -17.56       Horizontal
  9760.00        23.60         38.10        8.03        35.03         34.70       54.00         -19.30       Horizontal
 12200.00          *                                                              54.00                      Horizontal
 14640.00         *                                                             54.00                        Horizontal
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 21 of 42


                                                                                     Report No.: GTS201806000203F01



Test channel:                                                      Highest
Peak value:
                   Read         Antenna         Cable       Preamp                                     Over
Frequency                                                                  Level      Limit Line
                   Level         Factor         Loss        Factor                                     Limit   polarization
  (MHz)                                                                  (dBuV/m)     (dBuV/m)
                  (dBuV)         (dB/m)         (dB)          (dB)                                     (dB)
     4960.00       63.42          31.44         4.79         37.78         61.87         74.00        -12.13        Vertical
     7440.00       51.91          36.66         6.77         35.56         59.78         74.00        -14.22        Vertical
     9920.00       45.54          38.30         8.09         35.14         56.79         74.00        -17.21        Vertical
 12400.00             *                                                                  74.00                      Vertical
 14880.00             *                                                                  74.00                      Vertical
     4960.00       65.73          31.44         4.79         37.78         64.18         74.00        -9.82        Horizontal
     7440.00       52.67          36.66         6.77         35.56         60.54         74.00        -13.46       Horizontal
     9920.00       45.97          38.30         8.09         35.14         57.22         74.00        -16.78       Horizontal
 12400.00             *                                                                  74.00                     Horizontal
 14880.00       *                                                                        74.00                     Horizontal
Average value:
              Read              Antenna         Cable       Preamp                                     Over
Frequency                                                                  Level      Limit Line
              Level              Factor         Loss        Factor                                     Limit   polarization
   (MHz)                                                                 (dBuV/m)     (dBuV/m)
             (dBuV)              (dB/m)         (dB)          (dB)                                     (dB)
  4960.00     42.30               31.44         4.79         37.78         40.75         54.00        -13.25        Vertical
     7440.00       27.64          36.66         6.77         35.56         35.51         54.00        -18.49        Vertical
     9920.00       21.71          38.30         8.09         35.14         32.96         54.00        -21.04        Vertical
 12400.00             *                                                                  54.00                      Vertical
 14880.00             *                                                                  54.00                      Vertical
     4960.00       43.56          31.44         4.79         37.78         42.01         54.00        -11.99       Horizontal
     7440.00       28.83          36.66         6.77         35.56         36.70         54.00        -17.30       Horizontal
     9920.00       23.45          38.30         8.09         35.14         34.70         54.00        -19.30       Horizontal
 12400.00             *                                                                  54.00                     Horizontal
 14880.00             *                                                                  54.00                     Horizontal
Remark:
1.    Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.    “*”, means this data is the too weak instrument of signal is unable to test.
3.    The emission levels of other frequencies are very lower than the limit and not show in test report.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                        Page 22 of 42


                                                                               Report No.: GTS201806000203F01



7.3.3   Bandedge emissions
All of the restriction bands were tested, and only the data of worst case was exhibited.

 Mode:                   Transmitting mode               Test channel:              Lowest channel
 Temp./Hum.(%H):         25℃/56%RH                       Polarity:                  Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 23 of 42


                                                                               Report No.: GTS201806000203F01




 Mode:                   Transmitting mode               Test channel:              Lowest channel
 Temp./Hum.(%H):         25℃/56%RH                       Polarity:                  Vertical




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 24 of 42


                                                                               Report No.: GTS201806000203F01




 Mode:                   Transmitting mode               Test channel:              Highest channel
 Temp./Hum.(%H):         25℃/56%RH                       Polarity:                  Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 25 of 42


                                                                               Report No.: GTS201806000203F01




 Mode:                   Transmitting mode               Test channel:              Highest channel
 Temp./Hum.(%H):         25℃/56%RH                       Polarity:                  Vertical




Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 26 of 42


                                                                               Report No.: GTS201806000203F01



7.4 20dB Occupy Bandwidth
      Test Requirement:                FCC Part15 C Section 15.249/15.215
      Test Method:                     ANSI C63.10:2013
      Limit:                           Operation Frequency range 2400MHz~2483.5MHz
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Measurement Data
          Test channel                        20dB bandwidth(MHz)                            Result
               Lowest                                 4.609                                  Pass
               Middle                                 4.569                                  Pass
               Highest                                4.609                                  Pass


Test plot as follows:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 27 of 42


                                                                               Report No.: GTS201806000203F01




                                                  Lowest channel




                                                   Middle channel




                                                  Highest channel




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 28 of 42



Document Created: 2018-07-26 12:47:19
Document Modified: 2018-07-26 12:47:19

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC