                                 RF EXPOSURE REPORT

                                   REPORT NO.:                    SA130111C27
                                     MODEL NO.:                   WDAM2120-RX
                                              FCC ID:             JVPRX
                                       RECEIVED:                  Jan. 15, 2013
                                            TESTED:               Feb. 04 ~ Feb. 18, 2013
                                             ISSUED:              Feb. 22, 2013



                            APPLICANT: BenQ Corporation

                               ADDRESS: 16 Jihu Road,Neihu, Taipei 114, Taiwan



                             ISSUED BY: Bureau Veritas Consumer Products Services
                                        (H.K.) Ltd., Taoyuan Branch

                     LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist.,
                                  New Taipei City, Taiwan, R.O.C.

                  TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei
                                 Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C.




    This report should not be used by the client to claim
    product certification, approval, or endorsement by
    any government agencies.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results
set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar
or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon
the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by
our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such
issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the
correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the
compliance or non-compliance to the specification.

 Report No.: SA130111C27                                                  1 of 5                                        Report Format Version 5.0.0


                                          TABLE OF CONTENTS

RELEASE CONTROL RECORD ..............................................................................................................3
1.   CERTIFICATION ...........................................................................................................................4
2.   RF EXPOSURE ............................................................................................................................5
2.1  LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE) ......................................................5
2.2  MPE CALCULATION FORMULA .................................................................................................5
2.3  CLASSIFICATION.........................................................................................................................5
2.4  CALCULATION RESULT OF MAXIMUM CONDUCTED POWER ...............................................5




Report No.: SA130111C27                                             2 of 5                                     Report Format Version 5.0.0


                            RELEASE CONTROL RECORD

ISSUE NO.             REASON FOR CHANGE                    DATE ISSUED
SA130111C27           Original release                     Feb. 22, 2013




Report No.: SA130111C27                   3 of 5     Report Format Version 5.0.0


1. CERTIFICATION

                PRODUCT: Wireless Receiver
                    MODEL: WDAM2120-RX
                    BRAND: BenQ
              APPLICANT: BenQ Corporation
                   TESTED: Feb. 04 ~ Feb. 18, 2013
         TEST SAMPLE: ENGINEERING SAMPLE
            STANDARDS: FCC Part 2 (Section 2.1091)
                              FCC OET Bulletin 65, Supplement C (01-01)
                              IEEE C95.1




The above equipment (model: WDAM2120-RX) has been tested by Bureau
Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found
compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are
true and accurate accounts of the measurements of the sample’s EMC
characteristics under the conditions specified in this report.




   PREPARED BY            :                              , DATE :   Feb. 22, 2013
                                 Ivy Lin / Specialist


   APPROVED BY            :                              , DATE :   Feb. 22, 2013
                                 Ken Liu / Manager




Report No.: SA130111C27                        4 of 5               Report Format Version 5.0.0


2. RF EXPOSURE
2.1    LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

   FREQUENCY              ELECTRIC FIELD MAGNETIC FIELD POWER DENSITY                 AVERAGE TIME
   RANGE (MHz)            STRENGTH (V/m) STRENGTH (A/m)   (mW/cm2)                      (minutes)
               LIMITS FOR GENERAL POPULATION / UNCONTROLLED EXPOSURE
      300-1500                    …                …                F/1500                    30
   1500-100,000                   …                …                 1.0                      30

F = Frequency in MHz


2.2    MPE CALCULATION FORMULA

Pd = (Pout*G) / (4*pi*r2)
where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm


2.3    CLASSIFICATION

The antenna of this product, under normal use condition, is at least 20cm away from
the body of the user. So, this device is classified as Mobile Device.


2.4    CALCULATION RESULT OF MAXIMUM CONDUCTED POWER

 FREQUENCY                            ANTENNA                         POWER
                   MAX POWER                             DISTANCE                          LIMIT
    BAND                                GAIN                         DENSITY
                     (dBm)                                  (cm)                         (mW/cm2)
    (MHz)                               (dBi)                        (mW/cm2)
   5180-5240              14.16          2                  20         0.008                   1

   5745-5825              21.90          2                  20         0.049                   1




Report No.: SA130111C27                         5 of 5                         Report Format Version 5.0.0