Dipole Validation

FCC ID: JVPH0523

RF Exposure Info

Download: PDF
FCCID_257753

SAR Data Report 02052303

  Start        :   05-Jun-02 9:29:10 am
  End          :   05-Jun-02 9:35:13 am
  Code Version :   4.08
  Robot Version:   4.08

Product Data:
  Type              :   Validation
  Frequency         :   835 MHz
  Transmit Pwr      :   0.250 W
  Antenna Type      :   Dipole

Measurement Data:
  Phantom Name          :   SAM-FLAT
  Phantom Type          :   Uniphantom
  Tissue Type           :   Brain
  Tissue Dielectric     :   43.400
  Tissue Conductivity   :   0.870
  Tissue Density        :   1.000
  Robot Name            :   CRS

Probe Data:
  Probe Name              : PCT002
  Probe Type              : E Fld Triangle
  Frequency               : 835 MHz
  Tissue Type             : Brain
  Calibrated Dielectric   : 40.700
  Calibrated Conductivity : 0.890
  Calibrated Density      : 1.000
  Probe Offset            : 2.400 mm
  Conversion Factor       : 5.800
  Probe Sensitivity : 3.597    3.474   3.049    mV/(mW/cm^2)
  Amplifier Gains   : 20.00    20.00   20.00

Sample:
  Rate:          6000 Samples/Sec
  Count:         100 Samples
  NIDAQ Gain:    5

Comments:
  835 MHz Validation

  CF=1; Amb. Temp= 21.1 'C; Liq. Temp=21.0 'C




Area Scan - Max Peak SAR Value at x=1.0 y=0.0 = 2.34 W/kg

Zoom Scan - Max Peak SAR Value at x=1.0 y=1.0 z=0.0 = 3.68 W/kg

Max 1g SAR at x=1.0 y=1.0 z=0.0 = 2.45 W/kg

Max 10g SAR at x=1.0 y=1.0 z=0.0 = 1.54 W/kg

Validation Results at 0.25 W:
Peak Nominal = 3.5, Error: 5.01 %
1g Nominal   = 2.4, Error: 3.19 %
10g Nominal = 1.6, Error: -0.94 %


                              SAR - Z Axis
                          at Hotspot x:1.0 y:1.0

             4




             3
SAR (mW/g)




             2




             1




             0
                 0   10                            20   30
                                 Z Distance (mm)


1g SAR Values




                2.451
                2.375
                2.299
                2.223
                2.147
                2.071
                1.995
                1.919
                1.842
                1.766
                1.690




SAR Data Report 02052316

  Start        :   05-Jun-02 09:40:33 am
  End          :   05-Jun-02 09:45:58 am
  Code Version :   4.08
  Robot Version:   4.08

Product Data:
  Type              :   Validation
  Frequency         :   1900 MHz
  Transmit Pwr      :   0.250 W
  Antenna Type      :   Dipole

Measurement Data:
  Phantom Name          :   SAM-FLAT
  Phantom Type          :   Uniphantom
  Tissue Type           :   Brain
  Tissue Dielectric     :   41.400
  Tissue Conductivity   :   1.420
  Tissue Density        :   1.000
  Robot Name            :   CRS

Probe Data:
  Probe Name              : PCT002
  Probe Type              : E Fld Triangle
  Frequency               : 1900 MHz
  Tissue Type             : Brain
  Calibrated Dielectric   : 40.200
  Calibrated Conductivity : 1.410
  Calibrated Density      : 1.000
  Probe Offset            : 2.400 mm
  Conversion Factor       : 4.700
  Probe Sensitivity : 3.000    2.995   2.653    mV/(mW/cm^2)
  Amplifier Gains   : 20.00    20.00   20.00

Sample:
  Rate:          6000 Samples/Sec
  Count:         100 Samples
  NIDAQ Gain:    5

Comments:
  1900 MHz Validation

  CF=1; Amb. Temp= 21.3 'C; Liq. Temp=21.0 'C




Area Scan - Max Peak SAR Value at x=0.0 y=1.0 = 9.25 W/kg

Zoom Scan - Max Peak SAR Value at x=-1.0 y=0.0 z=0.0 = 16.62 W/kg

Max 1g SAR at x=0.0 y=1.0 z=0.0 = 9.74 W/kg

Max 10g SAR at x=0.0 y=1.0 z=0.0 = 5.09 W/kg

Validation Results at 0.25 W:
Peak Nominal = 18.0, Error: -7.77 %
1g Nominal   = 9.9, Error: -1.86 %
10g Nominal = 5.1, Error: -0.67 %


                               SAR - Z Axis
                           at Hotspot x:-1.0 y:0.0

             18


             16


             14


             12
SAR (mW/g)




             10


             8


             6


             4


             2


             0
                  0   10                             20   30
                                   Z Distance (mm)


1g SAR Values




                9.74
                9.23
                8.71
                8.20
                7.68
                7.17
                6.65
                6.14
                5.63
                5.11
                4.60





Document Created: 2002-06-28 11:36:58
Document Modified: 2002-06-28 11:36:58