SAR System Validation

FCC ID: JUPTRIMTRACE

RF Exposure Info

Download: PDF
FCCID_833384

                                                                                     Date/Time: 6/21/2007 5:34:43 PM

Test Laboratory: Compliance Certification Services

System Performance Check @ 900MHz
DUT: Dipole 900 MHz; Type: D900V2;Serial: D900V2 - SN:108

Communication System: CW;Frequency: 900 MHz;Duty Cycle: 1:1
Medium parameters used: f = 900 MHz; σ = 1.05 mho/m; εr = 54.3; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(7.58, 7.58, 7.58); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

d=15mm, Pin=250mW/Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 2.99 mW/g

d=15mm, Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 53.7 V/m; Power Drift = -0.117 dB
Peak SAR (extrapolated) = 4.10 W/kg
SAR(1 g) = 2.78 mW/g; SAR(10 g) = 1.81 mW/g
Maximum value of SAR (measured) = 3.00 mW/g




                     0 dB = 3.00mW/g


                                                                 Date/Time: 6/21/2007 5:47:14 PM

Test Laboratory: Compliance Certification Services

System Performance Check @ 900MHz
DUT: Dipole 900 MHz; Type: D900V2; Serial: D900V2 - SN:108

Communication System: CW; Frequency: 900 MHz;Duty Cycle: 1:1



d=15mm, Pin=250mW/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm
Maximum value of SAR (measured) = 2.99 mW/g


                                                                                    Date/Time: 6/22/2007 12:09:27 AM

Test Laboratory: Compliance Certification Services

System Performance Check @ 1900MHz
DUT: Dipole 1900 MHz; Type: D1900V2;Serial: D1900V2 - SN:5d043

Communication System: CW;Frequency: 1900 MHz;Duty Cycle: 1:1
Medium parameters used: f = 1900 MHz; σ = 1.47 mho/m; εr = 53.7; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(6.61, 6.61, 6.61); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: SAM 2; Type: SAM 2; Serial: 1050
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

d=10mm; Pin=250mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 11.6 mW/g

d=10mm; Pin=250mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 88.6 V/m; Power Drift = 0.064 dB
Peak SAR (extrapolated) = 18.5 W/kg
SAR(1 g) = 10.3 mW/g; SAR(10 g) = 5.4 mW/g
Maximum value of SAR (measured) = 11.5 mW/g




                     0 dB = 11.5mW/g


                                                                  Date/Time: 6/22/2007 12:20:14 AM

Test Laboratory: Compliance Certification Services

System Performance Check @ 1900MHz
DUT: Dipole 1900 MHz; Type: D1900V2; Serial: D1900V2 - SN:5d043

Communication System: CW; Frequency: 1900 MHz;Duty Cycle: 1:1



d=10mm; Pin=250mW/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm, dz=2.5mm
Maximum value of SAR (measured) = 11.6 mW/g



Document Created: 2007-06-22 01:50:38