SAR Plots GSM 850

FCC ID: JUPTRIMTRACE

RF Exposure Info

Download: PDF
FCCID_833381

                                                                                       Date/Time: 6/21/2007 7:34:38 PM

Test Laboratory: Compliance Certification Services

Cell Band
DUT: TrimTrac Pro E; Type: N/A ;Serial: Project No 07U11144

Communication System: GSM850;Frequency: 837 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 837 MHz; σ = 0.996 mho/m; εr = 55.3; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(8, 8, 8); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172



Position 1 - M ch/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.670 mW/g

Position 1 - M ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 4.52 V/m; Power Drift = 0.116 dB
Peak SAR (extrapolated) = 0.820 W/kg
SAR(1 g) = 0.638 mW/g; SAR(10 g) = 0.480 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.672 mW/g


                                                                                      Date/Time: 6/22/2007 12:50:42 AM

Test Laboratory: Compliance Certification Services

Cell Band
DUT: TrimTrac Pro E; Type: N/A;Serial: Project No 07U11144

Communication System: GSM850;Frequency: 837 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 837 MHz; σ = 0.996 mho/m; εr = 55.3; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(8, 8, 8); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

Position 1 - M ch with alternate Battery/Area Scan (9x13x1): Measurement grid: dx=15mm,
dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.667 mW/g

Position 1 - M ch with alternate Battery/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 4.25 V/m; Power Drift = 0.150 dB
Peak SAR (extrapolated) = 0.825 W/kg
SAR(1 g) = 0.645 mW/g; SAR(10 g) = 0.485 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.678 mW/g


                                                                    Date/Time: 6/22/2007 1:07:51 AM

Test Laboratory: Compliance Certification Services

Cell Band
DUT: TrimTrac Pro E; Type: N/A; Serial: Project No 07U11144

Communication System: GSM850; Frequency: 837 MHz;Duty Cycle: 1:8



Position 1 - M ch with alternate Battery/Z Scan (1x1x41): Measurement grid: dx=20mm, dy=20mm,
dz=2.5mm

Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.682 mW/g


                                                                                       Date/Time: 6/21/2007 8:01:50 PM

Test Laboratory: Compliance Certification Services

Cell Band
DUT: TrimTrac Pro E; Type: N/A;Serial: Project No 07U11144

Communication System: GSM850;Frequency: 837 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 837 MHz; σ = 0.996 mho/m; εr = 55.3; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(8, 8, 8); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

Position 2 - M ch/Area Scan (9x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.359 mW/g

Position 2 - M ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 4.28 V/m; Power Drift = 0.121 dB
Peak SAR (extrapolated) = 0.446 W/kg
SAR(1 g) = 0.349 mW/g; SAR(10 g) = 0.263 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.367 mW/g


                                                                                       Date/Time: 6/21/2007 8:30:13 PM

Test Laboratory: Compliance Certification Services

Cell Band
DUT: TrimTrac Pro E; Type: N/A;Serial: Project No 07U11144

Communication System: GSM850;Frequency: 837 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 837 MHz; σ = 0.996 mho/m; εr = 55.3; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(8, 8, 8); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172



Position 3 - M ch/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.280 mW/g

Position 3 - M ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 5.65 V/m; Power Drift = 0.023 dB
Peak SAR (extrapolated) = 0.357 W/kg
SAR(1 g) = 0.272 mW/g; SAR(10 g) = 0.200 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.287 mW/g


                                                                                       Date/Time: 6/21/2007 8:55:06 PM

Test Laboratory: Compliance Certification Services

Cell Band
DUT: TrimTrac Pro E; Type: N/A;Serial: Project No 07U11144

Communication System: GSM850;Frequency: 837 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 837 MHz; σ = 0.996 mho/m; εr = 55.3; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(8, 8, 8); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

Position 4 - M ch/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.310 mW/g

Position 4 - M ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 4.48 V/m; Power Drift = 0.117 dB
Peak SAR (extrapolated) = 0.407 W/kg
SAR(1 g) = 0.309 mW/g; SAR(10 g) = 0.227 mW/g
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.327 mW/g


                                                                                      Date/Time: 6/21/2007 10:29:34 PM

Test Laboratory: Compliance Certification Services

Cell Band
DUT: TrimTrac Pro E; Type: N/A;Serial: Project No 07U11144

Communication System: GSM850;Frequency: 837 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 837 MHz; σ = 0.996 mho/m; εr = 55.3; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(8, 8, 8); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

Position 5 - M ch/Area Scan (7x9x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.017 mW/g

Position 5 - M ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 3.50 V/m; Power Drift = -0.055 dB
Peak SAR (extrapolated) = 0.023 W/kg
SAR(1 g) = 0.016 mW/g; SAR(10 g) = 0.012 mW/g
Info: Interpolated medium parameters used for SAR evaluation.


                                                                                      Date/Time: 6/21/2007 11:14:47 PM

Test Laboratory: Compliance Certification Services

Cell Band
DUT: TrimTrac Pro E; Type: N/A;Serial: Project No 07U11144

Communication System: GSM850;Frequency: 837 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 837 MHz; σ = 0.996 mho/m; εr = 55.3; ρ = 1000 kg/m3
Phantom section: Flat Section

Room AmbientTemperature: 22.0deg. C; Liquid Temperature: 21.0 deg. C

DASY4 Configuration:
- Area Scan setting - Find Secondary Maximum Within: 2.0 dB and witha peak SAR value greater than 0.0012W/kg
- Probe: EX3DV4 - SN3554; ConvF(8, 8, 8); Calibrated: 4/24/2007
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE3 Sn427; Calibrated: 11/16/2006
- Phantom: Flat Phantom ELI4.0; Type: QDOVA001BA; Serial: SN:1003
- Measurement SW: DASY4, V4.7 Build 53; Postprocessing SW: SEMCAD, V1.8 Build 172

Position 6 - M ch/Area Scan (7x11x1): Measurement grid: dx=15mm, dy=15mm
Info: Interpolated medium parameters used for SAR evaluation.
Maximum value of SAR (measured) = 0.024 mW/g

Position 6 - M ch/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=7.5mm, dy=7.5mm, dz=5mm
Reference Value = 4.61 V/m; Power Drift = -0.029 dB
Peak SAR (extrapolated) = 0.030 W/kg
SAR(1 g) = 0.023 mW/g; SAR(10 g) = 0.018 mW/g
Info: Interpolated medium parameters used for SAR evaluation.



Document Created: 2007-06-22 01:41:53
Document Modified: 2007-06-22 01:41:53