CKC test report

FCC ID: JQ6537Y

Test Report

Download: PDF
FCCID_62889

                                       CERTIFICATION TEST REPORT

                                                         FOR THE

                 RFID PROXIMITY READER, 5375A MAXIPROX (5375-310-01)

                                 FCC PART 15 SUBPART C &
                         CANADIAN DEPARTMENT OF INDUSTRY RSS-210

                                                     COMPLIANCE


                                  DATE OF ISSUE: SEPTEMBER 14, 1999



PREPARED FOR:                                                             PREPARED BY:

HID Corporation                                                           Joyce Walker
9292 Jeronimo Road                                                        CKC Laboratories, Inc.
Irvine, CA 92618-1905                                                     5473A Clouds Rest
                                                                          Mariposa, CA 95338
P.O. No: 008008
W.O. No: 72268                                                            Date of test: August 30 & September 2, 1999

Report No: FC99-030

DOCUMENTATION CONTROL:                                                    APPROVED BY:




_____________________________                                             _____________________________
Tracy Phillips                                                            Dennis Ward
Documentation Control Supervisor                                          Director of Laboratories
CKC Laboratories, Inc.                                                    CKC Laboratories, Inc.

This report contains a total of 34 pages and may be reproduced in full only. Partial reproduction may only be done with the
written consent of CKC Laboratories, Inc.

                                                                                                           Page 1 of 34
                                                                                                   Report No: FC99-030


                                                   TABLE OF CONTENTS



Administrative Information .............................................................................................3
Summary Of Results........................................................................................................4
Equipment Under Test (EUT) Description......................................................................4
Measurement Uncertainty................................................................................................4
EUT Operating Frequency...............................................................................................4
Peripheral Devices...........................................................................................................4
Report Of Measurements.................................................................................................5
        Table 1: Highest Radiated Emission Levels - 9 kHz-30 MHz ...........................5
        Table 2: Six Highest Radiated Emission Levels - 30 MHz-1000 MHz .............6
        Table 3: Six Highest Conducted Emission Levels – 12 & 24 VDC...................7
Table A : List Of Test Equipment ...................................................................................8
EUT Setup .......................................................................................................................9
Test Instrumentation And Analyzer Settings...................................................................10
        Table B : Analyzer Bandwidth Settings Per Frequency Range...........................10
        Spectrum Analyzer Detector Functions...............................................................11
               Peak .........................................................................................................11
               Quasi-Peak...............................................................................................11
               Average....................................................................................................11
Test Methods ...................................................................................................................12
        Radiated Emissions Testing.................................................................................12
        Conducted Emissions Testing .............................................................................13
Sample Calculations ........................................................................................................13
Appendix A : Information About The Equipment Under Test........................................14
        I/O Ports...............................................................................................................15
        Crystal Oscillators ...............................................................................................15
        Printed Circuit Boards .........................................................................................15
        Cable Information................................................................................................15
        Required EUT Changes To Comply....................................................................15
        Photograph Showing Radiated Emissions...........................................................16
        Photograph Showing Radiated Emissions...........................................................17
        Photograph Showing Conducted Emissions........................................................18
Appendix B : Measurement Data Sheets.........................................................................19




                                                                                                                     Page 2 of 34
                                                                                                             Report No: FC99-030


CKC Laboratories, Inc. has Certificates of Accreditation from the following agencies:
DATech (Germany); A2LA (USA); FCC (USA); VCCI (Japan); BSMI (Taiwan); HOKLAS (Hong Kong).
CKC Laboratories, Inc. has Letters of Acceptance through an MRA for the following agencies:
ACA/NATA (Australia); SABS (South Africa); SWEDAC (Sweden); TUV Rheinland-Germany; TUV Rheinland-
Korea; TUV Rheinland-Russia; Radio Communications Agency (RA); NEMKO (Norway).



                           ADMINISTRATIVE INFORMATION


DATE OF TEST:                                       August 30 & September 2, 1999

PURPOSE OF TEST:                                    To demonstrate the compliance of the RFID
                                                    Proximity Reader, 5375A MaxiProx (5375-
                                                    310-01), with the requirements for FCC Part
                                                    15 Subpart C & RSS-210 devices.

MANUFACTURER:                                       HID Corporation
                                                    9292 Jeronimo Road
                                                    Irvine, CA 92618-1905

REPRESENTATIVE:                                     Ken Long

TEST LOCATION:                                      CKC Laboratories, Inc.
                                                    5473A Clouds Rest
                                                    Mariposa, CA 95338

TEST PERSONNEL:                                     Dustin Oaks

TEST METHOD:                                        ANSI C63.4 1992

FREQUENCY RANGE TESTED:                             9kHz - 1000 MHz

EQUIPMENT UNDER TEST:                               RFID Proximity Reader
                                                    Manuf:      HID Corporation
                                                    Model:      5375A MaxiPro
                                                    Final Assy: 5375-310-01
                                                    Serial:     N/A
                                                    FCC ID:     JQ6537Y(pending)




                                                                                   Page 3 of 34
                                                                           Report No: FC99-030


                                 SUMMARY OF RESULTS


The HID Corporation RFID Proximity Reader, 5375A MaxiProx (5375-310-01), was tested in
accordance with ANSI C63.4 1992 for compliance with FCC Part 15 Subpart C and RSS-210.

As received, the above equipment was found to be fully compliant with the limits of FCC Part 15
Subpart C and RSS-210. The results in this report apply only to the items tested, as identified
herein.


EQUIPMENT UNDER TEST (EUT) DESCRIPTION

RFID Proximity Reader


MEASUREMENT UNCERTAINTY

Associated with data in this report is a ±4dB measurement uncertainty.


EUT OPERATING FREQUENCY

The EUT was operating at 0.125 MHz.


TEMPERATURE AND HUMIDITY DURING TESTING

The temperature during testing was within +15°C and + 35°C.
The relative humidity was between 20% and 75%.


PERIPHERAL DEVICES

The EUT was tested with the following peripheral device(s):

DC Power Supply
Manuf: Topward Electric Instruments
Model: 2306
Serial: 920035
FCC ID: N/A




                                                                                 Page 4 of 34
                                                                         Report No: FC99-030


                                  REPORT OF MEASUREMENTS


The following tables report the highest worst case levels recorded during the tests performed on
the RFID Proximity Reader, 5375A MaxiProx (5375-310-01). All readings taken are peak
readings unless otherwise noted by a “Q” or “A”. The data sheets from which these tables were
compiled are contained in Appendix B.


                          Table 1: Highest Radiated Emission Levels – 9 kHz-30 MHz

                  METER         CORRECTION FACTORS           CORRECTED         SPEC
FREQUENCY        READING      Mag Cable 15.31   Dist          READING          LIMIT      MARGIN      NOTES
                              Loop
     MHz          dBµV         dB    dB   DB    dB             dBµV/m         dBµV/m         dB

    0.125          48.5        12.2    0.1    -40.0              20.8           25.7         -4.9     NA-1

    0.125          50.9        12.2    0.1    -40.0              23.2           25.7         -2.5     NA-2


Test Method:                ANSI C63.4 1992                NOTES:       H = Horizontal Polarization
Spec Limit :                FCC Part 15.209                             V = Vertical Polarization
Test Distance:              30 Meters                                   N = No Polarization
                                                                        D = Dipole Reading
                                                                        Q = Quasi Peak Reading
                                                                        A = Average Reading
                                                                        1 = 12VDC
                                                                        2 = 24VDC



COMMENTS: EUT operating on 12/24VDC via DC power supply. EUT is in continuos read
mode with no card in the field. 40dB correction factor IAW FCC 15.31. Frequency Range
scanned from 9kHz to 30MHz.




                                                                                          Page 5 of 34
                                                                                  Report No: FC99-030


                    Table 2: Six Highest Radiated Emission Levels – 30 MHz-1000 MHz

                  METER        CORRECTION FACTORS         CORRECTED          SPEC
FREQUENCY        READING      Ant  Amp Cable   Dist        READING           LIMIT      MARGIN      NOTES
   MHz             dBµV       dB    dB    dB   dB           dBµV/m          dBµV/m        dB

    32.064         42.6      12.8   -27.0    1.0               29.4           40.0        -10.6      V-1

    43.879         39.4      10.7   -27.0    1.2               24.3           40.0        -15.7      V-2

    56.217         44.3       9.8   -26.8    1.3               28.6           40.0        -11.4      V-2

   108.806         32.6      12.7   -26.8    1.9               20.4           43.5        -23.1      V-2

   134.956         33.2      13.6   -26.8    2.1               22.1           43.5        -21.4      V-1

   150.042         36.1      12.7   -26.8    2.2               24.2           43.5        -19.3      V-1


Test Method:               ANSI C63.4 1992              NOTES:        H = Horizontal Polarization
Spec Limit :               FCC Part 15.209                            V = Vertical Polarization
Test Distance:             3 Meters                                   N = No Polarization
                                                                      D = Dipole Reading
                                                                      Q = Quasi Peak Reading
                                                                      A = Average Reading
                                                                      1 = 12VDC
                                                                      2 = 24VDC



COMMENTS: EUT operating on 12 VDC & 24VDC via power supply. EUT operating in
normal configuration, no card in the field. Frequency Range scanned from 30MHz – 1000MHz.




                                                                                        Page 6 of 34
                                                                                Report No: FC99-030


                    Table 3: Six Highest Conducted Emission Levels - 12 & 24 VDC

                METER        CORRECTION FACTORS          CORRECTED        SPEC
FREQUENCY      READING     Lisn        Cable              READING         LIMIT     MARGIN    NOTES
   MHz           dBµV       dB    dB    dB   dB             dBµV          dBµV        dB

  2.907180       37.7       0.0            0.10              37.8          48.0       -10.2    B-2

  3.145198       38.0       0.0            0.10              38.1          48.0        -9.9    B-2

  9.908866       40.2       0.0            0.20              40.4          48.0        -7.6    W-2

  13.644450      40.7       0.0            0.20              40.9          48.0        -7.1    W-1

  19.415950      41.0       0.0            0.30              41.3          48.0        -6.7    W-2

  19.611300      38.0       0.0            0.30              38.3          48.0        -9.7    W-2


Test Method:             ANSI C63.4 1992               NOTES:       Q = Quasi Peak Reading
Spec Limit :             FCC 15.207                                 A = Average Reading
                                                                    B = Black Lead
                                                                    W = White Lead
                                                                    1 = 12VDC
                                                                    2 = 24VDC



COMMENTS: EUT operating in normal mode with no card in the field. EUT operating on
12VDC & 24VDC via power supply.




                                                                                     Page 7 of 34
                                                                             Report No: FC99-030


                                           TABLE A

                                LIST OF TEST EQUIPMENT

                  Mariposa Site B Industry Canada File No. IC 3082-D
1. Spectrum Analyzer, Hewlett Packard, Model No. 8566B, CKC 1, S/N 2403A08241 (Display
   Unit), S/N 2209A01404 (rf Unit). Calibration date: July 7, 1999. Calibration due date: July 7,
   2000.

2. Preamp, Hewlett Packard, Model No. 8447D, S/N 1937A02604. Calibration Date: April 28,
   1999. Calibration Due: April 28, 2000.

3. Quasi-Peak Adapter, Hewlett Packard, Model No. 85650A, S/N 2811A01267. Calibration
   Date: July 7, 1999. Calibration Due; July 7, 2000.

4. Biconical Antenna, A & H Systems, Model No. SAS-200/542, S/N 156. Calibration Date:
   May 20, 1999. Calibration Due: May 20, 2000.

5. Log Periodic Antenna, A & H Systems, Model No. SAS-200/512, S/N 154. Calibration date:
   May 20, 1999. Calibration Due: May 20, 2000.

6. Magnetic Loop Antenna, EMCO, Model 6502, S/N 1074. Calibration date: June 16, 1999.
   Calibration due date: June 16, 2000.

7. LISN (FCC), Solar Electronics, S/N 855996, 992. Calibration date: June 4, 1999.
   Calibration due date: June 4, 2000.

8. LISN, Solar Electronics, S/N 8144793, 474. Calibration date: June 2, 1999. Calibration due
   date: June 2, 2000.

9. Mariposa Site B (Barn). Calibration date: June 18, 1998. Calibration due date: June 18
   2001.

10. Test software, EMI Test 3.08.




                                                                                  Page 8 of 34
                                                                          Report No: FC99-030


EUT SETUP

The equipment under test (EUT) and the peripheral(s) listed were set up in a manner that
represented their normal use. Any special conditions required for the EUT to operate normally
are identified in the comments that accompany Tables 1-3 for l radiated and conducted
emissions. Additionally, a complete description of all the ports and I/O cables is included on the
information sheets contained in Appendix A.

During radiated emissions testing, the EUT was mounted on a nonconductive, rotating table 80
cm above the conductive grid. The nonconductive table dimensions were 1 meter by 1.5 meters.
This configuration is typical for radiated emissions testing of table top devices.

I/O cables were connected to the EUT and peripherals in the manner required for normal
operation of the system. Excess cabling was bundled in the center in a serpentine fashion using
30-40 centimeter lengths.

During conducted emissions testing, the EUT was located on a wooden table measuring
approximately 80 cm high, 1 meter deep, and 1.5 meters in length. One wall of the room where
the EUT is located has a minimum 2 meter by 2 meter conductive plane. The EUT was mounted
on the wooden table 40 cm away from the conductive plane, and 80 cm from any other
conductive surface.

The vertical metal plane used for conducted emissions was grounded to the earth. Power to the
EUT was provided through a LISN. The LISN was grounded to the ground plane. All other
objects were kept a minimum of 80 cm away from the EUT during the conducted test.
Conducted emissions tests required the use of the LISN's listed in Table A.




                                                                                   Page 9 of 34
                                                                           Report No: FC99-030


TEST INSTRUMENTATION AND ANALYZER SETTINGS

The test instrumentation and equipment listed in Table A were used to collect both the radiated
and conducted emissions data for the RFID Proximity Reader, 5375A MaxiProx (5375-310-01).
For radiated measurements below 300 MHz, the biconical antenna was used. For frequencies
from 300 to 1000 MHz, the log periodic antenna was used. All antennas were located at a
distance of 30 meters from the edge of the EUT while doing testing from 9kHz to 30 MHz, and 3
meters while doing testing from 30 MHz to 1 GHz. Conducted emissions tests required the use
of the FCC type LISN's.

The HP spectrum analyzer was used for all measurements. Table B shows the analyzer
bandwidth settings that were used in designated frequency bands. For conducted emissions, an
appropriate reference level and a vertical scale size of 10 dB per division were used. A 10 dB
external attenuator was also used during conducted tests, with internal offset correction in the
analyzer. During radiated testing, the measurements were made with 0 dB of attenuation, a
reference level of 97 dBµV, and a vertical scale of 10 dB per division.


      TABLE B : ANALYZER BANDWIDTH SETTINGS PER FREQUENCY RANGE

        TEST             BEGINNING FREQUENCY        ENDING FREQUENCY        BANDWIDTH SETTING
CONDUCTED EMISSIONS             450 kHz                   30 MHz                  9 kHz
 RADIATED EMISSIONS              9 kHz                    150 kHz                200 Hz
 RADIATED EMISSIONS             150 kHz                   30 MHz                  9 kHz
 RADIATED EMISSIONS             30 MHz                   1000 MHz                120 kHz




                                                                                Page 10 of 34
                                                                         Report No: FC99-030


SPECTRUM ANALYZER DETECTOR FUNCTIONS

The notes that accompany the measurements contained in Tables 1-3 indicate the type of detector
function used to obtain the given readings. Unless otherwise noted, all readings were made in
the "Peak" mode. Whenever a "Quasi-Peak" or "Average" reading is listed as one of the highest
readings, this is indicated as a "Q" or an "A" in the appropriate table. The following paragraphs
describe in more detail the detector functions and when they were used to obtain the emissions
data for the RFID Proximity Reader, 5375A MaxiProx (5375-310-01).

Peak

In this mode, the Spectrum Analyzer or test engineer recorded all emissions at their peak value
as the frequency band selected was scanned. By combining this function with another feature of
the analyzer called "peak hold," the analyzer had the ability to measure transients or low duty
cycle transient emission peak levels. In this mode the analyzer made a slow scan across the
frequency band selected and measured the peak emission value found at each frequency across
the band.

Quasi-Peak

When the true peak values exceeded or were within 2 dB of the specification limit, quasi-peak
measurements were taken using the HP Quasi-Peak Adapter for the HP Spectrum Analyzer. The
detailed procedure for making quasi peak measurements contained in the HP Quasi-Peak
Adapter manual were followed.

Average

When the frequencies are between 9-90 kHz, 110-490 kHz or exceed 1 GHz, average
measurements may be made using the spectrum analyzer. To make these measurements, the test
engineer reduces the video bandwidth on the analyzer until the modulation of the signal is
filtered out. At this point the analyzer is set into the linear mode and the scan time is reduced.




                                                                                  Page 11 of 34
                                                                           Report No: FC99-030


TEST METHODS

The radiated and conducted emissions data of the RFID Proximity Reader, 5375A MaxiProx
(5375-310-01) was taken with the HP Spectrum Analyzer. Incorporating the applicable
correction factors for distance, antenna, cable loss and amplifier gain, the data was reduced as
shown in the "Sample Calculations". The corrected data was then compared to the FCC Part 15,
Subpart C emissions limits to determine compliance.

Preliminary and final measurements were taken in order to better ensure that all emissions from
the EUT were found and maximized.

Radiated Emissions Testing

During the preliminary radiated scan, the EUT was powered up and operating in its defined FCC
test mode with the I/O cables and line cords facing the antenna. The frequency range of 9 kHz –
30 MHz was scanned with the magnetic loop antenna. The frequency range of 30 MHz - 88
MHz was then scanned with the biconical antenna located about 1.5 meter above the ground
plane in the vertical configuration. During this scan, the turntable was rotated and all peaks
which were at or near the limit were recorded. The frequency range of 100 - 300 MHz was
scanned with the biconical antenna in the same manner, and the peaks recorded. Lastly, a scan
of the FM band from 88 - 110 MHz was made, using a reduced resolution bandwidth and a
reduced frequency span. The biconical antenna was changed to the horizontal polarity and the
above steps were repeated. After changing to the log periodic antenna in the horizontal
configuration, the frequency range of 300 - 1000 MHz was scanned. The log periodic antenna
was changed to the vertical polarity and the frequency range of 300 - 1000 MHz was again
scanned. Care was taken to ensure that no frequencies were missed within the FM and TV
bands. An analysis was performed to determine if the signals that were at or near the limit were
caused by an ambient transmission. If unable to determine by analysis, the equipment was
powered down to make the final determination if the EUT was the source of the emission.

For the final radiated scan, the equipment was again positioned with its I/O and power cables
facing the antenna. A thorough scan of all frequencies was manually made using a small
frequency span, rotating the turntable as needed. Comparison with the previously recorded
measurements was then made.

Using the peak readings from both scans as a guide, the test engineer then maximized the
readings with respect to the table rotation, antenna height and configuration of the peripherals
and cables. Maximizing of the cables was achieved by monitoring the spectrum analyzer on a
closed circuit television monitor while the EUT cables were being moved and rearranged on the
EUT table for maximum emissions. Photographs showing the final worst case configuration of
the EUT are contained in Appendix A.




                                                                                Page 12 of 34
                                                                         Report No: FC99-030


Conducted Emissions Testing

For conducted emissions testing, a 30 to 50 second sweep time was used for automated
measurements in the frequency bands of 450 kHz to 1.705 MHz, 1.705 MHz to 3 MHz, and 3
MHz to 30 MHz. All readings within 20 dB of the limit were recorded. At frequencies where
the recorded emissions were close to the limit, further investigation was performed manually at a
slower sweep rate.


SAMPLE CALCULATIONS

The basic spectrum analyzer reading was converted using correction factors as shown in the
emissions readings in Tables 1-3. For radiated emissions in dBµV/m, the spectrum analyzer
reading in dBµV was corrected by using the following formula:

                 Meter reading (dBµV)
                 + Antenna Factor (dB)
                 + Cable Loss (dB)
                 - Distance Correction (dB)
                 - Pre-amplifier Gain (dB)

                 = Corrected Reading (dBµV/m)

This reading was then compared to the applicable specification limit to determine compliance.

A typical data sheet will display the following in column format:

# Freq    Rdng     Cable   Amp   Bicon    Mag     Log   Dist   15.31    Corr      Spec   Margin    Polar
  MHz     dBuV                            Loop                         dBuV/m
# means reading number
Freq MHz is the frequency in MHz of the obtained reading.
Rdng dBuV is the reading obtained on the spectrum analyzer in dBµV.
Amp is short for the preamplifier factor or gain in dB.
Bicon is the biconical antenna factor in dB.
Log is the log periodic antenna factor in dB.
Mag Loop is the magnetic loop antenna factor in dB.
Cable is the cable loss in dB of the coaxial cable on the OATS.
Dist is the distance factor (in dB). It is used when testing at a different test distance than the one
stated in the spec.
Corr dBµ  µV/m is the corrected reading which is now in dBµV/m (field strength).
Spec is the specification limit (dB) stated in the agency's regulations.
Margin is the closeness to the specified limit in dB; + is over and - is under the limit.
Polar is the Polarity of the antenna with respect to earth.
15.31 is the FCC extraploation factor.


                                                                                     Page 13 of 34
                                                                              Report No: FC99-030


                APPENDIX A

INFORMATION ABOUT THE EQUIPMENT UNDER TEST




                                            Page 14 of 34
                                     Report No: FC99-030


             INFORMATION ABOUT THE EQUIPMENT UNDER TEST
                      Test Software/Firmware: 5375-520-01
                           CRT was displaying: NA
                   Power Supply Manufacturer: Customer Supplied
                    Power Supply Part Number:
                   AC Line Filter Manufacturer: NA
                    AC Line Filter Part Number: NA
                Line voltage used during testing: 12 & 24 VDC


               I/O PORTS                             CRYSTAL OSCILLATORS
Type                               #           Type                Freq In MHz
DC Power & IO Signals              1           Crystal                 4.00


PRINTED CIRCUIT BOARDS
Function         Model & Rev                 Clocks, MHz           Layers     Location
All              Rev. 3                      4                     4
                                             0.001


                                CABLE INFORMATION

               Cable #:                          Cable(s) of this type:

           Cable Type: Shielded                          Shield Type: Foil with drain
                                                                      wire
         Construction: Multiconductor               Length In Meters: *
 Connected To End (1): MaxiProx                Connected To End (2): DC supply &
                                                                      controller
 Connector At End (1): None                    Connector At End (2):
Shield Grounded At (1): TB1-2                 Shield Grounded At (2): DC supply “-“ &
                                                                      chassis ground
          Part Number:                        Number of Conductors: 5 to 14
                 Notes:
*Up to 152m for Wiegand, 15.2m for RS232, or 1,220m for RS422



REQUIRED EUT CHANGES TO COMPLY:
None.




                                                                             Page 15 of 34
                                                                      Report No: FC99-030


PHOTOGRAPH SHOWING RADIATED EMISSIONS




        Radiated Emissions - Front View




                                                 Page 16 of 34
                                          Report No: FC99-030


PHOTOGRAPH SHOWING RADIATED EMISSIONS




        Radiated Emissions - Back View




                                                Page 17 of 34
                                         Report No: FC99-030


PHOTOGRAPH SHOWING CONDUCTED EMISSIONS




        Conducted Emissions - Front View




                                                  Page 18 of 34
                                           Report No: FC99-030


      APPENDIX B

MEASUREMENT DATA SHEETS




                                 Page 19 of 34
                          Report No: FC99-030


Test Location:        CKC Laboratories, Inc / 5473A Clouds Rest / Mariposa, CA 95338•   •   •

Customer:             HID
Specification:        FCC 15 C PARA 15.209
Work Order #:         72268                                               Date:    Mon Aug-30-1999
Test Type:            Maximized Emissions                                 Time:    16:51:41
Equipment:            Proximity Reader                               Sequence#:    32
Manufacturer:         HID                                            Tested By:    Dustin Oaks
Model:                5375A
S/N:                  N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                        Model #                       S/N
Proximity Reader*         HID                                 5375A                         N/A
 Support Devices:
Function                          Manufacturer                Model #                       S/N
DC Power Supply                   Topward Electric            2306                          920035
                                  Instruments
 Test Conditions / Notes:
EUT operating on 12/24VDC via DC power supply. EUT is in continuos read mode with no card in the field. 40dB
correction factor IAW FCC 15.31. Frequency Range scanned from 9kHz to 30MHz.
Measurement Data:          Reading listed by order taken.                   Test Distance: 30 Meters
                               Mag       Cable 15.31
  #       Freq          Rdng   Loop                                     Dist   Corr    Spec     Margin       Polar
          MHz           dBµV    dB        dB        dB         dB       Table dBµV/m dBµV/m       dB          Ant
      1 124.968k          50.9 +12.2       +0.1     -40.0                +0.0  23.2     25.7     -2.5        None
       Ave                                                                           EUT operating on
                                                                                     24VDC
      2    124.982k        48.5     +12.2     +0.1    -40.0              +0.0   20.8    25.7      -4.9       None
          Ave                                                                        EUT operating on
                                                                                     12VDC




                                                                                                       Page 20 of 34
                                                                                                Report No: FC99-030


Test Location:       CKC Laboratories, Inc / 5473A Clouds Rest / Mariposa, CA 95338 •     •   •

Customer:            HID
Specification:       FCC 15.209
Work Order #:        72268                                                 Date:    Mon Aug-30-1999
Test Type:           Maximized Emissions                                   Time:    16:58:37
Equipment:           Proximity Reader                                 Sequence#:    34
Manufacturer:        HID                                              Tested By:    Dustin Oaks
Model:               5375A
S/N:                 N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                       Model #                          S/N
Proximity Reader*         HID                                5375A                            N/A
 Support Devices:
Function                         Manufacturer                Model #                          S/N
DC Power Supply                  Topward Electric            2306                             920035
                                 Instruments
 Test Conditions / Notes:
EUT operating on 12VDC via power supply. EUT operating in normal configuration, no card in the field.
Measurement Data:         Reading listed by order taken.            Test Distance: 3 Meters
                              Amp Bicon           Log    Cable
  #        Freq        Rdng                                     Dist     Corr       Spec    Margin               Polar
           MHz         dBµV    dB        dB        dB     dB    Table dBµV/m dBµV/m           dB                  Ant
      1   56.219M        43.2   -26.8     +9.8      +0.0   +1.3 +0.0      27.5       40.0    -12.5               Vert

      2   32.064M         42.6      -27.0   +12.8     +0.0     +1.0     +0.0       29.4           40.0   -10.6   Vert

      3   43.870M         38.3      -27.0   +10.7     +0.0     +1.2     +0.0       23.2           40.0   -16.8   Vert

      4   150.042M        36.1      -26.8   +12.7     +0.0     +2.2     +0.0       24.2           43.5   -19.3   Vert

      5   108.813M        32.3      -26.8   +12.7     +0.0     +1.9     +0.0       20.1           43.5   -23.4   Vert

      6   134.956M        33.2      -26.8   +13.6     +0.0     +2.1     +0.0       22.1           43.5   -21.4   Vert




                                                                                                          Page 21 of 34
                                                                                                   Report No: FC99-030


Test Location:       CKC Laboratories, Inc / 5473A Clouds Rest / Mariposa, CA 95338•      •   •

Customer:            HID
Specification:       FCC 15.209
Work Order #:        72268                                                 Date:    Mon Aug-30-1999
Test Type:           Maximized Emissions                                   Time:    14:50:44
Equipment:           Proximity Reader                                 Sequence#:    29
Manufacturer:        HID                                              Tested By:    Dustin Oaks
Model:               5375A
S/N:                 N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                       Model #                          S/N
Proximity Reader*         HID                                5375A                            N/A
 Support Devices:
Function                         Manufacturer                Model #                          S/N
DC Power Supply                  Topward Electric            2306                             920035
                                 Instruments
 Test Conditions / Notes:
EUT operating on 24VDC via power supply. EUT operating in normal configuration, no card in the field.
Measurement Data:         Reading listed by order taken.            Test Distance: 3 Meters
                              Amp Bicon           Log    Cable
  #        Freq        Rdng                                     Dist     Corr       Spec    Margin               Polar
           MHz         dBµV    dB        dB        dB     dB    Table dBµV/m dBµV/m           dB                  Ant
      1   32.056M        40.2   -27.0 +12.8         +0.0   +1.0 +0.0      27.0       40.0    -13.0               Vert

      2   43.846M         39.3      -27.0   +10.7     +0.0     +1.2     +0.0       24.2           40.0   -15.8   Vert

      3   143.300M        31.5      -26.8   +13.2     +0.0     +2.1     +0.0       20.0           43.5   -23.5   Vert

      4   150.037M        34.0      -26.8   +12.7     +0.0     +2.2     +0.0       22.1           43.5   -21.4   Vert

      5   134.946M        31.5      -26.8   +13.6     +0.0     +2.1     +0.0       20.4           43.5   -23.1   Vert

      6   108.806M        32.6      -26.8   +12.7     +0.0     +1.9     +0.0       20.4           43.5   -23.1   Vert

      7   43.879M         39.4      -27.0   +10.7     +0.0     +1.2     +0.0       24.3           40.0   -15.7   Vert

      8   56.217M         44.3      -26.8    +9.8     +0.0     +1.3     +0.0       28.6           40.0   -11.4   Vert




                                                                                                          Page 22 of 34
                                                                                                   Report No: FC99-030


Test Location:       CKC Laboratories, Inc / 5473A Clouds Rest / Mariposa, CA 95338 •    •   •

Customer:            HID
Specification:       FCC 15.207
Work Order #:        72268                                                Date:    Thur Sep-02-1999
Test Type:           Conducted Emissions                                  Time:    18:35:41
Equipment:           Proximity Reader                                Sequence#:    44
Manufacturer:        HID                                             Tested By:    Dustin Oaks
Model:               5375A
S/N:                 N/A
 Equipment Under Test (* = EUT):
Function                  Manufacturer                       Model #                         S/N
Proximity Reader*         HID                                5375A                           N/A
 Support Devices:
Function                         Manufacturer                Model #                         S/N
DC Power Supply                  Topward Electric            2306                            920035
                                 Instruments
 Test Conditions / Notes:
EUT operating in normal mode with no card in the field. EUT operating on 12VDC via power supply.
Measurement Data:             Reading listed by margin.                        Test Lead: Black
                                Cable
  #        Freq        Rdng                                            Dist   Corr   Spec               Margin   Polar
           MHz         dBµV         dB      dB       dB       dB       Table dBµV/m dBµV/m               dB       Ant
      1   13.644M        38.4        +0.2                               +0.0   38.6   48.0               -9.4    Black

      2   11.783M         34.6       +0.2                              +0.0       34.8           48.0    -13.2   Black

      3    9.611M         34.4       +0.2                              +0.0       34.6           48.0    -13.4   Black

      4   11.674M         33.8       +0.2                              +0.0       34.0           48.0    -14.0   Black

      5    4.395M         33.7       +0.1                              +0.0       33.8           48.0    -14.2   Black

      6    9.949M         33.4       +0.2                              +0.0       33.6           48.0    -14.4   Black

      7    8.758M         33.4       +0.2                              +0.0       33.6           48.0    -14.4   Black

      8   556.608k        33.5       +0.1                              +0.0       33.6           48.0    -14.4   Black

      9   14.000M         33.3       +0.2                              +0.0       33.5           48.0    -14.5   Black

   10      1.493M         33.4       +0.1                              +0.0       33.5           48.0    -14.5   Black

   11     14.888M         33.2       +0.2                              +0.0       33.4           48.0    -14.6   Black

   12     12.757M         33.2       +0.2                              +0.0       33.4           48.0    -14.6   Black

   13     16.379M         33.0       +0.3                              +0.0       33.3           48.0    -14.7   Black

   14     26.821M         32.9       +0.3                              +0.0       33.2           48.0    -14.8   Black


                                                                                                         Page 23 of 34
                                                                                                  Report No: FC99-030


15   6.259M   33.0   +0.2   +0.0   33.2   48.0   -14.8   Black




                                                  Page 24 of 34
                                           Report No: FC99-030


      ore Te mceimTe naras worme
      ree mar      Hex las ta  Soaweer o
sowam snsaore
  wo




  wooe        ns                           ns   sns


Test Location:      CKC Laboratories, Inc / 5473A Clouds Rest / Mariposa, CA 95338 •    •   •

Customer:           HID
Specification:      FCC 15.207
Work Order #:       72268                                                Date:    Thu Sep-02-1999
Test Type:          Conducted Emissions                                  Time:    18:40:04
Equipment:          Proximity Reader                                Sequence#:    45
Manufacturer:       HID                                             Tested By:    Dustin Oaks
Model:              5375A
S/N:                N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                      Model #                         S/N
Proximity Reader*         HID                               5375A                           N/A
 Support Devices:
Function                        Manufacturer                Model #                         S/N
DC Power Supply                 Topward Electric            2306                            920035
                                Instruments
 Test Conditions / Notes:
EUT operating in normal mode with no card in the field. EUT operating on 12VDC via power supply.
Measurement Data:            Reading listed by margin.                        Test Lead: White
                               Cable
  #        Freq       Rdng                                            Dist   Corr   Spec               Margin   Polar
           MHz        dBµV         dB      dB       dB        dB      Table dBµV/m dBµV/m               dB       Ant
      1   13.644M       40.7        +0.2                               +0.0   40.9   48.0               -7.1    White

      2   9.919M         37.9       +0.2                               +0.0      38.1           48.0     -9.9   White

      3   11.873M        37.5       +0.2                               +0.0      37.7           48.0    -10.3   White

      4   9.611M         37.5       +0.2                               +0.0      37.7           48.0    -10.3   White

      5   15.030M        36.0       +0.3                               +0.0      36.3           48.0    -11.7   White

      6   9.830M         34.4       +0.2                               +0.0      34.6           48.0    -13.4   White

      7   16.876M        34.0       +0.3                               +0.0      34.3           48.0    -13.7   White

      8   11.674M        33.9       +0.2                               +0.0      34.1           48.0    -13.9   White

      9   9.512M         33.6       +0.2                               +0.0      33.8           48.0    -14.2   White

   10     12.508M        33.5       +0.2                               +0.0      33.7           48.0    -14.3   White

   11     2.137M         33.6       +0.1                               +0.0      33.7           48.0    -14.3   White

   12     28.704M        33.2       +0.4                               +0.0      33.6           48.0    -14.4   White

   13     24.086M        33.2       +0.4                               +0.0      33.6           48.0    -14.4   White

   14     20.819M        33.3       +0.3                               +0.0      33.6           48.0    -14.4   White


                                                                                                        Page 26 of 34
                                                                                                 Report No: FC99-030


15   11.337M   33.3   +0.2   +0.0   33.5   48.0   -14.5   White




                                                   Page 27 of 34
                                            Report No: FC99-030


      ore Te mczim me nae wornie
      ree mar      Hex lwee    Soaweer a
sowam snsaore
  wo




  wooe        ns                           ns   sns


Test Location:      CKC Laboratories, Inc / 5473A Clouds Rest / Mariposa, CA 95338 •    •   •

Customer:           HID
Specification:      FCC 15.207
Work Order #:       72268                                                Date:    Thu Sep-02-1999
Test Type:          Conducted Emissions                                  Time:    18:33:00
Equipment:          Proximity Reader                                Sequence#:    43
Manufacturer:       HID                                             Tested By:    Dustin Oaks
Model:              5375A
S/N:                N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                      Model #                         S/N
Proximity Reader*         HID                               5375A                           N/A
 Support Devices:
Function                        Manufacturer                Model #                         S/N
DC Power Supply                 Topward Electric            2306                            920035
                                Instruments
 Test Conditions / Notes:
EUT operating in normal mode with no card in the field. EUT operating on 24VDC via power supply.
Measurement Data:            Reading listed by margin.                        Test Lead: White
                               Cable
  #        Freq       Rdng                                            Dist   Corr   Spec               Margin   Polar
           MHz        dBµV         dB      dB       dB        dB      Table dBµV/m dBµV/m               dB       Ant
      1   19.150M       47.9        +0.3                               +0.0   48.2   48.0               +0.2    White

      2   19.416M        41.0       +0.3                               +0.0      41.3           48.0     -6.7   White

      3   9.909M         40.2       +0.2                               +0.0      40.4           48.0     -7.6   White

      4   13.644M        39.5       +0.2                               +0.0      39.7           48.0     -8.3   White

      5   19.611M        38.0       +0.3                               +0.0      38.3           48.0     -9.7   White

      6   12.508M        37.3       +0.2                               +0.0      37.5           48.0    -10.5   White

      7   15.278M        37.0       +0.3                               +0.0      37.3           48.0    -10.7   White

      8   13.751M        37.1       +0.2                               +0.0      37.3           48.0    -10.7   White

      9   20.144M        36.3       +0.3                               +0.0      36.6           48.0    -11.4   White

   10     11.873M        36.2       +0.2                               +0.0      36.4           48.0    -11.6   White

   11     11.754M        35.9       +0.2                               +0.0      36.1           48.0    -11.9   White

   12     11.674M        35.6       +0.2                               +0.0      35.8           48.0    -12.2   White

   13     2.391M         35.7       +0.1                               +0.0      35.8           48.0    -12.2   White

   14     2.125M         35.4       +0.1                               +0.0      35.5           48.0    -12.5   White


                                                                                                        Page 29 of 34
                                                                                                 Report No: FC99-030


15     12.011M   35.2   +0.2   +0.0   35.4   48.0   -12.6   White

16     19.150M   26.0   +0.3   +0.0   26.3   48.0   -21.7   White
     QP




                                                     Page 30 of 34
                                              Report No: FC99-030


      ore Te mcem me wass wornie
      ree mar     es lwee      Sowea
sowam snsaore
  wo




  wooe      ns                         ns   sns


Test Location:      CKC Laboratories, Inc / 5473A Clouds Rest / Mariposa, CA 95338 •    •   •

Customer:           HID
Specification:      FCC 15.207
Work Order #:       72268                                                Date:    Thu Sep-02-1999
Test Type:          Conducted Emissions                                  Time:    18:27:20
Equipment:          Proximity Reader                                Sequence#:    42
Manufacturer:       HID                                             Tested By:    Dustin Oaks
Model:              5375A
S/N:                N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                      Model #                         S/N
Proximity Reader*         HID                               5375A                           N/A
 Support Devices:
Function                        Manufacturer                Model #                         S/N
DC Power Supply                 Topward Electric            2306                            920035
                                Instruments
 Test Conditions / Notes:
EUT operating in normal mode with no card in the field. EUT operating on 24VDC via power supply.
Measurement Data:            Reading listed by margin.                        Test Lead: Black
                               Cable
  #       Freq        Rdng                                            Dist   Corr   Spec               Margin   Polar
          MHz         dBµV         dB      dB       dB        dB      Table dBµV/m dBµV/m               dB       Ant
      1   3.145M        38.0        +0.1                               +0.0   38.1   48.0               -9.9    Black

      2   2.907M         37.7       +0.1                               +0.0      37.8           48.0    -10.2   Black

      3   3.403M         37.0       +0.1                               +0.0      37.1           48.0    -10.9   Black

      4   13.609M        36.4       +0.2                               +0.0      36.6           48.0    -11.4   Black

      5   19.931M        35.5       +0.3                               +0.0      35.8           48.0    -12.2   Black

      6   2.659M         35.7       +0.1                               +0.0      35.8           48.0    -12.2   Black

      7   14.994M        35.3       +0.3                               +0.0      35.6           48.0    -12.4   Black

      8   20.464M        35.2       +0.3                               +0.0      35.5           48.0    -12.5   Black

      9   20.286M        35.0       +0.3                               +0.0      35.3           48.0    -12.7   Black

   10     3.641M         35.2       +0.1                               +0.0      35.3           48.0    -12.7   Black

   11     29.982M        34.6       +0.3                               +0.0      34.9           48.0    -13.1   Black

   12     4.137M         34.8       +0.1                               +0.0      34.9           48.0    -13.1   Black

   13     19.327M        34.5       +0.3                               +0.0      34.8           48.0    -13.2   Black

   14     6.269M         34.6       +0.2                               +0.0      34.8           48.0    -13.2   Black


                                                                                                        Page 32 of 34
                                                                                                 Report No: FC99-030


15   2.123M   34.6   +0.1   +0.0   34.7   48.0   -13.3   Black




                                                  Page 33 of 34
                                           Report No: FC99-030


      ore Te mceimTe zza wormie
      ree mar      Hex baa ta Sower a
sowam snsaore
  wo




  wooe       ns                         ns   sns



Document Created: 1999-10-08 10:29:55