Test Setup Photos on Pages 17 and 18

FCC ID: JQ6535Y

Test Setup Photos

Download: PDF
FCCID_124763

                                ADDENDUM TO TEST REPORT FC99-014

                                                         FOR THE

                                         PROXPRO, 5355/8A (5355-300)

                                            FCC PART 15 SUBPART C
                                             SECTION 15.207/15.209

                                                     COMPLIANCE


                                  DATE OF ISSUE: SEPTEMBER 19, 2000



PREPARED FOR:                                                             PREPARED BY:

HID Corporation                                                           Joyce Walker
9292 Jeronimo                                                             CKC Laboratories, Inc.
Irvine, CA 92618-1905                                                     5473A Clouds Rest
                                                                          Mariposa, CA 95338
P.O. No: 007532
W.O. No: 70946                                                            Date of test: February 18, 25, 1999

Report No: FC99-014A

DOCUMENTATION CONTROL:                                                    APPROVED BY:




_____________________________                                             _____________________________
Tracy Phillips                                                            Dennis Ward
Documentation Control Supervisor                                          Director of Laboratories
CKC Laboratories, Inc.                                                    CKC Laboratories, Inc.
This report contains a total of 25 pages and may be reproduced in full only. Partial reproduction may only be done with the
written consent of CKC Laboratories, Inc.

                                                                                                               Page 1 of 25
                                                                                                     Report No: FC99-014A


                                                    TABLE OF CONTENTS



Administrative Information .............................................................................................3
Summary Of Results........................................................................................................4
Equipment Under Test (EUT) Description......................................................................4
Measurement Uncertainty................................................................................................4
EUT Operating Frequency...............................................................................................4
Peripheral Devices...........................................................................................................5
Report Of Measurements.................................................................................................6
        Table 1: Six Highest Radiated Emission Levels – 9kHz-30MHz .......................6
        Table 2: Six Highest Radiated Emission Levels - 30MHz-1000MHz ................7
        Table 3: Six Highest Conducted Emission Levels ..............................................8
Table A : List Of Test Equipment ...................................................................................9
EUT Setup .......................................................................................................................10
Test Instrumentation And Analyzer Settings...................................................................10
        Table B : Analyzer Bandwidth Settings Per Frequency Range...........................11
        Spectrum Analyzer Detector Functions...............................................................11
               Peak .........................................................................................................11
               Quasi-Peak...............................................................................................11
               Average....................................................................................................12
Test Methods ...................................................................................................................12
        Radiated Emissions Testing.................................................................................12
        Conducted Emissions Testing .............................................................................13
Sample Calculations ........................................................................................................13
Appendix A : Information About The Equipment Under Test........................................15
        I/O Ports...............................................................................................................16
        Crystal Oscillators ...............................................................................................16
        Printed Circuit Boards .........................................................................................16
        Required EUT Changes To Comply....................................................................16
        Photograph Showing Radiated Emissions...........................................................17
        Photograph Showing Conducted Emissions........................................................18
Appendix B: Measurement Data Sheets..........................................................................19




                                                                                                                          Page 2 of 25
                                                                                                                Report No: FC99-014A


CKC Laboratories, Inc. has Certificates of Accreditation from the following agencies:
DATech (Germany); A2LA (USA); FCC (USA); VCCI (Japan); BSMI (Taiwan); HOKLAS (Hong Kong).
CKC Laboratories, Inc. has Letters of Acceptance through an MRA for the following agencies:
ACA/NATA (Australia); SABS (South Africa); SWEDAC (Sweden); TUV Rheinland-Germany; TUV Rheinland-
Korea; TUV Rheinland-Russia; Radio Communication Agency (RA); NEMKO (Norway).



                           ADMINISTRATIVE INFORMATION


DATE OF TEST:                                       February 18, 25, 1999

PURPOSE OF TEST:                                    To demonstrate the compliance of the
                                                    ProxPro, 5355/8A (5355-300), with the
                                                    requirements for FCC Part 15 Subpart C
                                                    Sections 15.207/15.209 devices.
                                                    The addendum is to accommodate product
                                                    name changes by the manufacturer.

MANUFACTURER:                                       HID Corporation
                                                    9292 Jeronimo
                                                    Irvine, CA 92618-1905

REPRESENTATIVE:                                     Frank de Vall

TEST LOCATION:                                      CKC Laboratories, Inc.
                                                    5473A Clouds Rest
                                                    Mariposa, CA 95338

TEST PERSONNEL:                                     Dustin Oaks

TEST METHOD:                                        ANSI C63.4 1992

FREQUENCY RANGE TESTED:                             9 kHz - 1000 MHz

EQUIPMENT UNDER TEST:                               ProxPro
                                                    Manuf:          HID Corporation
                                                    Model:          5355/8A (5355-300)
                                                    Serial:         N/A
                                                    FCC ID:         JQ6535Y (pending)




                                                                                       Page 3 of 25
                                                                             Report No: FC99-014A


                                  SUMMARY OF RESULTS


The HID Corporation ProxPro, 5355/8A (5355-300), was tested in accordance with ANSI C63.4
1992 for compliance with FCC Part 15 Subpart C Sections 15.207/15.209.

As received, the above equipment was found to be fully compliant with the limits of FCC Part 15
Subpart C Sections 15.207/15.209. The results in this report apply only to the items tested, as
identified herein.


EQUIPMENT UNDER TEST (EUT) DESCRIPTION

RFID Access Control Reader.

The following model has been tested by CKC Laboratories:

Prox Reader, 5355/8B

The following additional model is identical electrically to the one, which was tested, or any
differences between them do not affect their EMC characteristics, and therefore they comply
with the level of testing equivalent to the tested models.

ProxPro, 5355/8A (5355-300)


MEASUREMENT UNCERTAINTY

Associated with data in this report is a ±4dB measurement uncertainty.


EUT OPERATING FREQUENCY

The EUT was operating at 125 kHz.


TEMPERATURE AND HUMIDITY DURING TESTING

The temperature during testing was within +15°C and + 35°C.
The relative humidity was between 20% and 75%.




                                                                                      Page 4 of 25
                                                                            Report No: FC99-014A


PERIPHERAL DEVICES

The EUT was tested with the following peripheral device(s):

Power Supply                                   Power Supply
Manuf: Sorensen                                Manuf: Topward Electronic Instruments
Model: DCR60 - 30B                             Model: 2306
Serial: 0176                                   Serial: 920035
FCC ID: N/A                                    FCC ID: N/A




                                                                                Page 5 of 25
                                                                      Report No: FC99-014A


                                   REPORT OF MEASUREMENTS


The following tables report the six highest worst case levels recorded during the tests performed
on the ProxPro, 5355/8A (5355-300). All readings taken are peak readings unless otherwise
noted by a “Q” or “A”. The data sheets from which these tables were compiled are contained in
Appendix B.


                          Table 1: Six Highest Radiated Emission Levels - 9kHz-30MHz

                  METER          CORRECTION FACTORS           CORRECTED         SPEC
FREQUENCY        READING        Mag  Cable FCC    Dist         READING          LIMIT     MARGIN       NOTES
                                            15.31
     MHz          dBµV          dB    dB     dB   dB             dBµV/m        dBµV/m           dB

    0.125          42.5         12.2     0.1    -40.0             14.8           25.7          -10.9    N

    0.375          28.2         14.3     0.1    -40.0              2.6           16.1          -13.5    N

    0.500          6.8          12.8     0.2     0.0              19.8           33.6          -13.8    N

    0.625          9.9          11.6     0.2     0.0              21.7           31.7          -10.0    N

    0.750          0.5          10.7     0.2     0.0              11.4           30.1          -18.7    N

    0.875          7.5          10.0     0.2     0.0              17.7           28.7          -11.0    N


Test Method:                ANSI C63.4 1992                 NOTES:       N = No Polarization
Spec Limit :                FCC Part 15.209
Test Distance:              30 Meters



COMMENTS: EUT operating in normal mode. No Proxcard in field. EUT receiving operating
voltage of 24VDC via power supply. 40dB/Dec correction used in accordance to FCC Part
15.31.




                                                                                              Page 6 of 25
                                                                                    Report No: FC99-014A


                     Table 2: Six Highest Radiated Emission Levels - 30MHz-1000MHz

                  METER        CORRECTION FACTORS         CORRECTED          SPEC
FREQUENCY        READING     Amp   Ant   Cable Dist        READING           LIMIT      MARGIN     NOTES
   MHz             dBµV       dB    dB    dB                dBµV/m          dBµV/m        dB

    33.940         49.4      -27.3   12.6    1.0               35.7           40.0         -4.3      VQ

    48.063         46.5      -27.2   11.0    1.3               31.6           40.0         -8.4      VQ

    65.072         49.3      -27.2   8.9     1.4               32.4           40.0         -7.6      VQ

   119.976         45.5      -27.2   13.8    2.0               34.1           43.5         -9.4       V

   188.025         42.0      -26.8   16.7    2.6               34.5           43.5         -9.0       V

   192.037         41.4      -26.8   17.1    2.6               34.3           43.5         -9.2       V


Test Method:               ANSI C63.4 1992              NOTES:        Q = Quasi Peak Reading
Spec Limit :               FCC Part 15.209                            V = Vertical Polarization
Test Distance:             3 Meters



COMMENTS: EUT operating in normal mode. No Proxcard in field. EUT receiving operating
voltage of 24VDC via power supply.




                                                                                            Page 7 of 25
                                                                                  Report No: FC99-014A


                              Table 3: Six Highest Conducted Emission Levels

                  METER        CORRECTION FACTORS           CORRECTED          SPEC
FREQUENCY        READING     Lisn                            READING           LIMIT     MARGIN    NOTES
   MHz             dBµV       dB    dB    dB   dB              dBµV            dBµV        dB

   8.509804        34.1       0.0                                34.1          48.0       -13.9       W

  11.511150        35.4       0.0                                35.4          48.0       -12.6       B

  11.639690        34.2       0.0                                34.2          48.0       -13.8       B

  15.142350        34.2       0.0                                34.2          48.0       -13.8       W

  15.640430        35.0       0.0                                35.0          48.0       -13.0       W

  16.636600        35.6       0.0                                35.6          48.0       -12.4       W


Test Method:               ANSI C63.4 1992                NOTES:        B = Black Lead
Spec Limit :               FCC Part 15.207                              W = White Lead
Test Distance:             No Distance




COMMENTS: EUT is operating in normal operating mode. No Proxcard located in field. EUT
received operating voltage of 24VDC via power supply. Negative power lead from EUT tied to
DC power supply chassis ground.




                                                                                            Page 8 of 25
                                                                                  Report No: FC99-014A


                                        TABLE A

                              LIST OF TEST EQUIPMENT



1. Spectrum Analyzer, Hewlett Packard, Model No. 8566B, S/N 2209A01404. Calibration
   date: June 12, 1998. Calibration due date: June 12, 1999.

2. Preamp, Hewlett Packard, Model No. 8447D, S/N 1937A02604. Calibration date: April 10,
   1998. Calibration due date: April 10, 1999.

3. Quasi-Peak Adapter, Hewlett Packard, Model No. 85650A, S/N 2811A01267. Calibration
   date: June 12, 1998. Calibration due date: June 12, 1999.

4. Biconical Antenna, A & H Systems, Model No. SAS-200/542, S/N 156. Calibration date:
   June 9, 1998. Calibration due date: June 9, 1999.

5. Log Periodic Antenna, A & H Systems, Model No. SAS-200/512, S/N 154. Calibration date:
   June 9, 1998. Calibration due date: June 9, 1999.

6. Magnetic Loop Antenna, EMCO, Model No. 6502, S/N 1074. Calibration date: May 11,
   1998. Calibration due date: May 11, 1999.

7. LISN (FCC), Solar Electronics, S/N 855996, 992. Calibration date: May 28, 1998.
   Calibration due date: May 28, 1999.




                                                                                  Page 9 of 25
                                                                        Report No: FC99-014A


EUT SETUP

The equipment under test (EUT) and the peripheral(s) listed were set up in a manner that
represented their normal use. Any special conditions required for the EUT to operate normally
are identified in the comments that accompany Table 1-3 for radiated and conducted emissions.
Additionally, a complete description of all the ports and I/O cables is included on the information
sheets contained in Appendix A.

During radiated emissions testing, the EUT was mounted on a nonconductive, rotating table 80
cm above the conductive grid. The nonconductive table dimensions were 1 meter by 1.5 meters.
This configuration is typical for radiated emissions testing of wall mounted devices.

I/O cables were connected to the EUT and peripheral in the manner required for normal
operation of the system. Excess cabling was bundled in the center in a serpentine fashion using
30-40 centimeter lengths.

During conducted emissions testing, the EUT was located on a wooden table measuring
approximately 80 cm high, 1 meter deep, and 1.5 meters in length. One wall of the room where
the EUT is located has a minimum 2-meter by 2-meter conductive plane. The EUT was mounted
on the wooden table 40 cm away from the conductive plane, and 80 cm from any other
conductive surface.

The vertical metal plane used for conducted emissions was grounded to the earth. Power to the
EUT was provided through a LISN. The LISN was grounded to the ground plane. All other
objects were kept a minimum of 80 cm away from the EUT during the conducted test.
Conducted emissions tests required the use of the LISN's listed in Table A.


TEST INSTRUMENTATION AND ANALYZER SETTINGS

The test instrumentation and equipment listed in Table A were used to collect both the radiated
and conducted emissions data for the ProxPro, 5355/8A (5355-300). For frequencies below 30
MHz, the magnetic loop antenna was used. For radiated measurements below 300 MHz, the
biconical antenna was used. For frequencies from 300 to 1000 MHz, the log periodic antenna
was used. All antennas were located at a distance of 30 meters from the edge of the EUT while
doing testing from 9kHz to 30 MHz, and 3 meters while doing testing from 30 MHz to 1 GHz.
Conducted emissions tests required the use of the FCC type LISN's.




                                                                                      Page 10 of 25
                                                                             Report No: FC99-014A


The HP spectrum analyzer was used for all measurements. Table B shows the analyzer
bandwidth settings that were used in designated frequency bands. For conducted emissions, an
appropriate reference level and a vertical scale size of 10 dB per division were used. A 10 dB
external attenuator was also used during conducted tests, with internal offset correction in the
analyzer. During radiated testing, the measurements were made with 0 dB of attenuation, a
reference level of 97 dBµV, and a vertical scale of 10 dB per division.


       TABLE B : ANALYZER BANDWIDTH SETTINGS PER FREQUENCY RANGE

        TEST              BEGINNING FREQUENCY        ENDING FREQUENCY        BANDWIDTH SETTING
CONDUCTED EMISSIONS              450 kHz                   30 MHz                  9 kHz
 RADIATED EMISSIONS               9 kHz                    150 kHz                200 Hz
 RADIATED EMISSIONS              150 kHz                   30 MHz                  9 kHz
 RADIATED EMISSIONS              30 MHz                   1000 MHz                120 kHz



SPECTRUM ANALYZER DETECTOR FUNCTIONS

The notes that accompany the measurements contained in Tables 1, 2 and 3 indicate the type of
detector function used to obtain the given readings. Unless otherwise noted, all readings were
made in the "Peak" mode. Whenever a "Quasi-Peak" or "Average" reading is listed as one of the
six highest readings, this is indicated as a "Q" or an "A" in the appropriate table. The following
paragraphs describe in more detail the detector functions and when they were used to obtain the
emissions data for the ProxPro, 5355/8A (5355-300).

Peak

In this mode, the Spectrum Analyzer or test engineer recorded all emissions at their peak value
as the frequency band selected was scanned. By combining this function with another feature of
the analyzer called "peak hold," the analyzer had the ability to measure transients or low duty
cycle transient emission peak levels. In this mode the analyzer made a slow scan across the
frequency band selected and measured the peak emission value found at each frequency across
the band.

Quasi-Peak

When the true peak values exceeded or were within 2 dB of the specification limit, quasi-peak
measurements were taken using the HP Quasi-Peak Adapter for the HP Spectrum Analyzer. The
detailed procedure for making quasi peak measurements contained in the HP Quasi-Peak
Adapter manual were followed.




                                                                                     Page 11 of 25
                                                                            Report No: FC99-014A


Average

When the frequencies are below 30 MHz, average measurements may be made using the
spectrum analyzer. To make these measurements, the test engineer reduces the video bandwidth
on the analyzer until the modulation of the signal is filtered out. At this point the analyzer is set
into the linear mode and the scan time is reduced.


TEST METHODS

The radiated and conducted emissions data of the ProxPro, 5355/8A (5355-300), was taken with
the HP Spectrum Analyzer. Incorporating the applicable correction factors for distance, antenna,
cable loss and amplifier gain, the data was reduced as shown in the "Sample Calculations". The
corrected data was then compared to the FCC Part 15 Subpart C Sections 15.207/15.209
emissions limits to determine compliance.

Preliminary and final measurements were taken in order to better ensure that all emissions from
the EUT were found and maximized.

Radiated Emissions Testing

During the preliminary radiated scan, the EUT was powered up and operating in its defined FCC
test mode with the I/O cables and power cable facing the antenna. The frequency range of 9 kHz
to 30 MHz was scanned with the magnetic loop antenna. The frequency range of 30 MHz - 88
MHz was then scanned with the biconical antenna located about 1.5 meter above the ground
plane in the vertical configuration. During this scan, the turntable was rotated and all peaks,
which were at or near the limit, were recorded. The frequency range of 100 - 300 MHz was
scanned with the biconical antenna in the same manner, and the peaks recorded. Lastly, a scan
of the FM band from 88 - 110 MHz was made, using a reduced resolution bandwidth and a
reduced frequency span. The biconical antenna was changed to the horizontal polarity and the
above steps were repeated. After changing to the log periodic antenna in the horizontal
configuration, the frequency range of 300 - 1000 MHz was scanned. The log periodic antenna
was changed to the vertical polarity and the frequency range of 300 - 1000 MHz was again
scanned. Care was taken to ensure that no frequencies were missed within the FM and TV
bands. An analysis was performed to determine if the signals that were at or near the limit were
caused by an ambient transmission. If unable to determine by analysis, the equipment was
powered down to make the final determination if the EUT was the source of the emission.

For the final radiated scan, the equipment was again positioned with its I/O and power cables
facing the antenna. A thorough scan of all frequencies was manually made using a small
frequency span, rotating the turntable as needed. Comparison with the previously recorded
measurements was then made.



                                                                                        Page 12 of 25
                                                                               Report No: FC99-014A


Using the peak readings from both scans as a guide, the test engineer then maximized the
readings with respect to the table rotation, antenna height and configuration of the peripheral and
cables. Maximizing of the cables was achieved by monitoring the spectrum analyzer on a closed
circuit television monitor while the EUT cables were being moved and rearranged on the EUT
table for maximum emissions. Photographs showing the final worst case configuration of the
EUT are contained in Appendix A.


Conducted Emissions Testing

For conducted emissions testing, a 30 to 50 second sweep time was used for automated
measurements in the frequency bands of 450 kHz to 1.705 MHz, 1.705 MHz to 3 MHz, and 3
MHz to 30 MHz. All readings within 20 dB of the limit were recorded. At frequencies where
the recorded emissions were close to the limit, further investigation was performed manually at a
slower sweep rate.



SAMPLE CALCULATIONS

The basic spectrum analyzer reading was converted using correction factors as shown in the
emissions readings in Tables 1, 2 and 3. For radiated emissions in dBµV/m, the spectrum
analyzer reading in dBµV was corrected by using the following formula:

               Meter reading (dBµV)
               + Antenna Factor (dB)
               + Cable Loss (dB)
               - Distance Correction (dB)
               - Pre-amplifier Gain (dB)

               = Corrected Reading (dBµV/m)

This reading was then compared to the applicable specification limit to determine compliance.




                                                                                      Page 13 of 25
                                                                             Report No: FC99-014A


A typical data sheet will display the following in column format:

#   Freq    Rdng    Cable    Amp    Bicon    Mag     FCC     Dist    Corr      Spec   Margin    Polar
    MHz     dBuV                                     15.31          dBuV/m

    LISN
# means reading number
Freq MHz is the frequency in MHz of the obtained reading.
Rdng dBuV is the reading obtained on the spectrum analyzer in dBµV.
Amp is short for the preamplifier factor or gain in dB.
Bicon is the biconical antenna factor in dB.
FCC 15.31 is 40dB/Dec correction used in accordance with 15.31.
Mag is the magnetic loop antenna factor in dB.
Cable is the cable loss in dB of the coaxial cable on the OATS.
Dist is the distance factor (in dB). It is used when testing at a different test distance than the one
stated in the spec.
Corr dBµ  µV/m is the corrected reading which is now in dBµV/m (field strength).
Spec is the specification limit (dB) stated in the agency's regulations.
Margin is the closeness to the specified limit in dB; + is over and - is under the limit.
Polar is the Polarity of the antenna with respect to earth.
FCC 15.31 is the average correction called in FCC Part 15.31.
LISN is the line impedance stabilization network factor in dB.




                                                                                         Page 14 of 25
                                                                                Report No: FC99-014A


                APPENDIX A

INFORMATION ABOUT THE EQUIPMENT UNDER TEST




                                               Page 15 of 25
                                      Report No: FC99-014A


            INFORMATION ABOUT THE EQUIPMENT UNDER TEST
                    Test Software/Firmware: None
                        CRT was displaying: NA
                 Power Supply Manufacturer: Customer Supplied
                  Power Supply Part Number: NA
                AC Line Filter Manufacturer: NA
                 AC Line Filter Part Number: NA
                  Voltage used during testing: 24VDC

              I/O PORTS                        CRYSTAL OSCILLATORS
Type                              #       Type               Freq In MHz
DC Power & Signals                1       Ceramic Resonator     4 MHz


PRINTED CIRCUIT BOARDS
Function         Model & Rev            Clocks, MHz           Layers         Location
All Electronics  Rev B                  4 MHz                 4


                              CABLE INFORMATION

              Cable #:                      Cable(s) of this type:

          Cable Type: Shielded                     Shield Type: Foil with Drain
         Construction: Multiconductor          Length In Meters: 152
 Connected To End (1): Reader             Connected To End (2): DC Supply and
                                                                 Controller
 Connector At End (1): None               Connector At End (2): None
Shield Grounded At (1): Shield Ground    Shield Grounded At (2): NC
          Part Number:                   Number of Conductors: 6 to 10
                Notes:


REQUIRED EUT CHANGES TO COMPLY:
None.




                                                                              Page 16 of 25
                                                                     Report No: FC99-014A


PHOTOGRAPH SHOWING RADIATED EMISSIONS




        Radiated Emissions - Front View




                                                   Page 17 of 25
                                          Report No: FC99-014A


PHOTOGRAPH SHOWING CONDUCTED EMISSIONS




        Conducted Emissions - Front View




                                                    Page 18 of 25
                                           Report No: FC99-014A


      APPENDIX B

MEASUREMENT DATA SHEETS




                                   Page 19 of 25
                          Report No: FC99-014A


Test Location:      CKC Laboratories, Inc. • 5473A Clouds Rest Rd, Barn • Mariposa, CA 95338 • (800)-500-
                    4EMC

Customer:           HID Corporation                                  Date: Feb-18-99
Specification:      FCC 15.209                                       Time: 10:46
Test Type:          Maximized Emissions                         Sequence#: 17
Equipment:          Proximity Reader
Manufacturer:       HID                                         Tested By: Dustin Oaks
Model:              5355/8B
S/N:                N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                    Model #                     S/N
Proximity Reader*         HID                             5355/8B                     N/A

 Support Devices:
Function                       Manufacturer               Model #                     S/N
Power Supply                   Sorensen                   DCR60 - 30B                 0176

 Test Conditions / Notes:
EUT operating in normal mode. No Proxcard in field. EUT receiving operating voltage of 24VDC via power
supply. 40dB/Dec correction used in accordance with FCC Part 15.31.

Measurement Data:                  Sorted by Margin                     Test Distance: 30 Meters
                                                 FCC
                                                15.31
  #       Freq     Rdng          Mag    Cable                       Dist   Corr   Spec    Margin           Polar
                   dBµV          dB       dB      dB       dB       dB    dBµV/m dBµV/m    dB
      1   625.144k    9.9        +11.6     +0.2    +0.0              +0.0    21.7    31.7   -10.0           None

      2   125.009k      42.5     +12.2    +0.1    -40.0             +0.0       14.8       25.7     -10.9    None

      3   874.973k       7.5     +10.0    +0.2    +0.0              +0.0       17.7       28.7     -11.0    None

      4   374.985k      28.2     +14.3    +0.1    -40.0             +0.0        2.6       16.1     -13.5    None

      5   500.144k       6.8     +12.8    +0.2    +0.0              +0.0       19.8       33.6     -13.8    None

      6   749.973k       0.5     +10.7    +0.2    +0.0              +0.0       11.4       30.1     -18.7    None

      7   250.144k      24.4     +14.7    +0.1    -40.0             +0.0       -0.8       19.6     -20.4    None




                                                                                                     Page 20 of 25
                                                                                            Report No: FC99-014A


Test Location:      CKC Laboratories, Inc. • 5473A Clouds Rest Rd, Barn •   Mariposa, CA 95338 • (800)-500-
                    4EMC
Customer:           HID Corporation                                 Date:   Feb-18-99
Specification:      FCC 15.209                                      Time:   14:54
Test Type:          Maximized Emissions                        Sequence#:   24
Equipment:          Proximity Reader
Manufacturer:       HID                                        Tested By:   Dustin Oaks
Model:              5355/8B
S/N:                N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                 Model #                     S/N
Proximity Reader*         HID                          5355/8B                     N/A

 Support Devices:
Function                       Manufacturer            Model #                     S/N
Power Supply                   Sorensen                DCR60 - 30B                 0176

 Test Conditions / Notes:
EUT operating in normal mode. No Proxcard in field. EUT receiving operating voltage of 24VDC via power
supply.

Measurement Data:                  Sorted by Margin                  Test Distance: 3 Meters
                                 Amp Bicon             Cable
  #        Freq     Rdng                                         Dist   Corr   Spec    Margin            Polar
           MHz      dBµV         dB       dB      dB     dB      dB    dBµV/m dBµV/m    dB
      1      33.940   49.3       -27.3    +12.6           +1.0    +0.0    35.7    40.0    -4.3             Vert
        Quasi Peak
      ^      33.905   54.3        -27.3   +12.6           +1.0   +0.0       40.6        40.0      +0.6     Vert

      3      65.072     49.3      -27.2    +8.9           +1.4   +0.0       32.4        40.0      -7.6     Vert
        Quasi Peak
      ^      65.070     51.8      -27.2    +8.9           +1.4   +0.0       34.9        40.0      -5.1     Vert

      5      48.063     46.5      -27.2   +11.0           +1.3   +0.0       31.6        40.0      -8.4     Vert
        Quasi Peak
      ^      48.054     50.7      -27.2   +11.0           +1.3   +0.0       35.8        40.0      -4.2     Vert

      7    188.025      42.0      -26.8   +16.7           +2.6   +0.0       34.5        43.5      -9.0     Vert

      8    192.036      41.4      -26.8   +17.1           +2.6   +0.0       34.3        43.5      -9.2     Vert

      9    119.976      45.5      -27.2   +13.8           +2.0   +0.0       34.1        43.5      -9.4     Vert

   10      168.043      42.0      -26.9   +14.8           +2.4   +0.0       32.3        43.5     -11.2     Vert

   11      180.041      40.4      -26.9   +15.9           +2.5   +0.0       31.9        43.5     -11.6     Vert




                                                                                                   Page 21 of 25
                                                                                          Report No: FC99-014A


Test Location:      CKC Laboratories, Inc. • 5473A Clouds Rest Rd, Barn •   Mariposa, CA 95338 • (800)-500-
                    4EMC
Customer:           HID Corporation                                 Date:    Feb-25-99
Specification:      FCC pt 15.207                                   Time:    10:02
Test Type:          Conducted Emissions                        Sequence#:    40
Equipment:          Proximity Reader
Manufacturer:       HID                                        Tested By:    Dustin Oaks
Model:              5355/8B
S/N:                N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                   Model #                    S/N
Proximity Reader*         HID                            5355/8B                    N/A

 Support Devices:
Function                       Manufacturer              Model #                    S/N
Power Supply                   Topward Electronic        2306                       920035
                               Instruments

 Test Conditions / Notes:
EUT is operating in normal operating mode. No Proxcard located in field. EUT received operating voltage of
24VDC via power supply. Negative power lead from EUT tied to DC power supply chassis ground.

Measurement Data:                  Sorted by Margin                       Test Lead: Black

  #       Freq    Rdng                                             Dist   Corr   Spec    Margin           Polar
          MHz     dBµV            dB      dB        dB    dB       dB    dBµV/m dBµV/m    dB
      1    11.511   35.4                                            +0.0    35.4    48.0   -12.6           Black

      2     16.653      34.8                                       +0.0      34.8        48.0     -13.2    Black

      3     11.640      34.2                                       +0.0      34.2        48.0     -13.8    Black

      4      8.632      33.9                                       +0.0      33.9        48.0     -14.1    Black

      5     17.660      33.8                                       +0.0      33.8        48.0     -14.2    Black

      6     16.139      33.8                                       +0.0      33.8        48.0     -14.2    Black

      7     17.022      33.7                                       +0.0      33.7        48.0     -14.3    Black

      8     16.010      33.7                                       +0.0      33.7        48.0     -14.3    Black

      9      7.009      33.6                                       +0.0      33.6        48.0     -14.4    Black

   10        1.510      33.5                                       +0.0      33.5        48.0     -14.5    Black




                                                                                                    Page 22 of 25
                                                                                           Report No: FC99-014A


     CKC Laboratories, Inc._. Date: Thy Feb25—1999 Tine: 100230 won: 70946
     ECC t5.207              Test Lead: Black       Sequencetl 40
dBy. 59697Connected to LISN
 se

70—

sa4

soe—

ane4

ane4

2004

1e                    :                                                 :
 asocne             mine                                             toune   coutte


Test Location:      CKC Laboratories, Inc. • 5473A Clouds Rest Rd, Barn •   Mariposa, CA 95338 • (800)-500-
                    4EMC
Customer:           HID Corporation                                 Date:    Feb-25-99
Specification:      FCC pt 15.207                                   Time:    10:02
Test Type:          Conducted Emissions                        Sequence#:    41
Equipment:          Proximity Reader
Manufacturer:       HID                                        Tested By:    Dustin Oaks
Model:              5355/8B
S/N:                N/A

 Equipment Under Test (* = EUT):
Function                  Manufacturer                   Model #                    S/N
Proximity Reader*         HID                            5355/8B                    N/A

 Support Devices:
Function                       Manufacturer              Model #                    S/N
Power Supply                   Topward Electronic        2306                       920035
                               Instruments

 Test Conditions / Notes:
EUT is operating in normal operating mode. No Proxcard located in field. EUT received operating voltage of
24VDC via power supply. Negative power lead from EUT tied to DC power supply chassis ground.

Measurement Data:                  Sorted by Margin                       Test Lead: White

  #       Freq    Rdng                                             Dist   Corr   Spec    Margin           Polar
          MHz     dBµV            dB      dB        dB    dB       dB    dBµV/m dBµV/m    dB
      1    16.637   35.6                                            +0.0    35.6    48.0   -12.4           White

      2     15.640      35.0                                       +0.0      35.0        48.0     -13.0    White

      3     15.142      34.2                                       +0.0      34.2        48.0     -13.8    White

      4     17.006      34.1                                       +0.0      34.1        48.0     -13.9    White

      5     15.512      34.1                                       +0.0      34.1        48.0     -13.9    White

      6      8.510      34.1                                       +0.0      34.1        48.0     -13.9    White

      7     13.632      33.9                                       +0.0      33.9        48.0     -14.1    White

      8     12.636      33.9                                       +0.0      33.9        48.0     -14.1    White

      9      1.020      33.8                                       +0.0      33.8        48.0     -14.2    White

   10        9.003      33.6                                       +0.0      33.6        48.0     -14.4    White




                                                                                                    Page 24 of 25
                                                                                           Report No: FC99-014A


     CKC Laboratories, Inc._. Date: Thu Feb25—1999 Tine: 100217 Won: 70946
     ECC t5.207              Test Lead: whie        Sequencetl 4t
dBy. 59697Connected to LISN
 se

70—

sa4

soe—

ane4

aned

2004

1e                    :                                                 :
 asocne             mine                                             toune   coutte



Document Created: 2000-09-21 09:46:36
Document Modified: 2000-09-21 09:46:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC