Test Report

FCC ID: JQ61351B

Test Report

Download: PDF
FCCID_787234

                           HID GLOBAL CORPORATION TEST REPORT

                                                      FOR THE

                                                1351 PROXPASS II

                              FCC PART 15 SUBPART C SECTION 15.209

                                                  COMPLIANCE



                                 DATE OF ISSUE: NOVEMBER 29, 2006



PREPARED FOR:                                                 PREPARED BY:

HID Global Corporation                                        Mary Ellen Clayton
9292 Jeromino Road                                            CKC Laboratories, Inc.
Irvine, CA 92618-1905                                         5046 Sierra Pines Drive
                                                              Mariposa, CA 95338

P.O. No.: 11008315                                            Date of test: November 17-20, 2006
W.O. No.: 85557


                                              Report No.: FC06-074



This report contains a total of 24 pages and may be reproduced in full only. Partial reproduction may only be done with the
written consent of CKC Laboratories, Inc. The results in this report apply only to the items tested, as identified herein.




                                                                                                            Page 1 of 24
                                                                                                   Report No.: FC06-074


                                                    TABLE OF CONTENTS

Administrative Information .............................................................................................3
FCC to Canada Standard Correlation Matrix...................................................................4
Conditions for Compliance ..............................................................................................4
Approvals.........................................................................................................................4
FCC 15.31(e) Voltage Variation......................................................................................5
FCC 15.31(m) Number Of Channels ...............................................................................5
FCC 15.33(a) Frequency Ranges Tested .........................................................................5
FCC 15.35 Analyzer Bandwidth Settings........................................................................5
FCC 15.203 Antenna Requirements ................................................................................5
FCC 15.205 Restricted Bands..........................................................................................5
EUT Operating Frequency...............................................................................................5
Temperature And Humidity During Testing....................................................................5
Equipment Under Test (EUT) Description ......................................................................6
Equipment Under Test .....................................................................................................6
Peripheral Devices ...........................................................................................................6
Report of Measurements ..................................................................................................7
       Table 1: FCC 15.209 Carrier Emission Levels....................................................7
       Table 2: FCC 15.209 Six Highest Radiated Emission Levels .............................8
       Occupied Bandwidth............................................................................................9
EUT Setup........................................................................................................................10
Correction Factors............................................................................................................10
       Table A: Sample Calculations .............................................................................10
Test Instrumentation and Analyzer Settings ....................................................................11
       Spectrum Analyzer Detector Functions ...............................................................11
                Peak..........................................................................................................11
                Quasi-Peak ...............................................................................................11
                Average ....................................................................................................11
EUT Testing.....................................................................................................................12
       Radiated Emissions..............................................................................................12
Appendix A: Test Setup Photographs..............................................................................13
       Photograph Showing Radiated Emissions ...........................................................14
       Photograph Showing Radiated Emissions ...........................................................15
       Photograph Showing Radiated Emissions ...........................................................16
       Photograph Showing Radiated Emissions ...........................................................17
Appendix B: Test Equipment List ...................................................................................18
Appendix C: Measurement Data Sheets ..........................................................................19




                                                                                                                             Page 2 of 24
                                                                                                                    Report No.: FC06-074


                   ADMINISTRATIVE INFORMATION


DATE OF TEST:                November 17-20, 2006


DATE OF RECEIPT:             November 17, 2006


MANUFACTURER:                HID Global Corporation
                             9292 Jeromino Road
                             Irvine, CA 92618-1905


REPRESENTATIVE:              Frank de Vall


TEST LOCATION:               CKC Laboratories, Inc.
                             5046 Sierra Pines Drive
                             Mariposa, CA 95338

TEST METHOD:                 ANSI C63.4 (2003)


PURPOSE OF TEST:             To demonstrate the compliance of the 1351
                             ProxPass II with the requirements for FCC Part 15
                             Subpart C Section 15.209 devices.




                                                                      Page 3 of 24
                                                             Report No.: FC06-074


               FCC TO CANADA STANDARD CORRELATION MATRIX


 Canadian     Canadian       FCC          FCC                       Test Description
 Standard      Section     Standard      Section
 RSS GEN        7.1.4       47CFR        15.203     Antenna Connector Requirements
 RSS GEN        7.2.1       47CFR       15.35(c)    Pulsed Operation
 RSS GEN        7.2.2       47CFR        15.207     AC Mains Conducted Emissions Requirement
 RSS 210         2.1        47CFR       15.215(c)   Frequency Stability Recommendation
 RSS 210         2.2        47CFR        15.205     Restricted Bands of Operation
 RSS 210         2.6        47CFR        15.209     General Radiated Emissions Requirement
             IC 3082A-1                  784962     Site File No.



CONDITIONS FOR COMPLIANCE
No modifications to the EUT were necessary to comply. Conducted emissions not required for
this device because it is battery powered.

                                         APPROVALS

                           Steve Behm, Director of Engineering Services

QUALITY ASSURANCE:                                  TEST PERSONNEL:




Joyce Walker, Quality Assurance Administrative      Randy Clark, EMC Engineer
Manager




Mike Wilkinson, EMC Engineer/Lab
Manager




                                                                                      Page 4 of 24
                                                                             Report No.: FC06-074


FCC 15.31(e) Voltage Variations
Not applicable to this device because it is battery powered.

FCC 15.31(m) Number Of Channels
This device operates on a single channel.

FCC 15.33(a) Frequency Ranges Tested
15.209 Radiated Emissions: 9 kHz – 1000 MHz

                          FCC SECTION 15.35:
           ANALYZER BANDWIDTH SETTINGS PER FREQUENCY RANGE
        TEST              BEGINNING FREQUENCY         ENDING FREQUENCY       BANDWIDTH SETTING
 RADIATED EMISSIONS               9 kHz                     150 kHz               200 Hz
 RADIATED EMISSIONS              150 kHz                    30 MHz                 9 kHz
 RADIATED EMISSIONS              30 MHz                    1000 MHz               120 kHz


FCC 15.203 Antenna Requirements
The antenna is an integral part of the EUT and is non-removable; therefore the EUT complies
with Section 15.203 of the FCC rules.

FCC 15.205 Restricted Bands
The fundamental operating frequency lies outside the restricted bands and therefore complies
with the requirements of Section 15.205 of the FCC rules. Any spurious emission coming from
the EUT was investigated to determine if any portion lies inside the restricted band. If any
portion of a spurious emissions signal was found to be within a restricted band, investigation was
performed to ensure compliance with Section 15.209.

EUT Operating Frequency
The EUT was operating at 139.6 kHz.

Temperature And Humidity During Testing
The temperature during testing was within +15°C and + 35°C.
The relative humidity was between 20% and 75%.




                                                                                        Page 5 of 24
                                                                               Report No.: FC06-074


EQUIPMENT UNDER TEST (EUT) DESCRIPTION
The customer declares the EUT tested by CKC Laboratories was representative of a production
unit.


EQUIPMENT UNDER TEST

ProxPass II
Manuf:        HID Global Corporation
Model:        1351
Serial:       111706
FCC ID:       JQ61351



PERIPHERAL DEVICES

The EUT was not tested with peripheral devices.




                                                                                    Page 6 of 24
                                                                           Report No.: FC06-074


                                 REPORT OF MEASUREMENTS

The following tables report the worst case emissions levels recorded during the tests performed
on the EUT. All readings taken were peak readings unless otherwise stated. The data sheets
from which the emissions tables were compiled are contained in Appendix C.



                                Table 1: FCC 15.209 Carrier Emission Levels

                  METER        CORRECTION FACTORS               CORRECTED      SPEC
FREQUENCY        READING     Cable Ant         Corr              READING       LIMIT      MARGIN          NOTES
   MHz             dBµV       dB    dB         dB                 dBµV/m      dBµV/m        dB

    0.138          53.8       0.2     10.1              -80.0      -15.9        24.8        -40.7          V

    0.138          53.2       0.2     10.1              -80.0      -16.5        24.8        -41.3          V

    0.139          53.0       0.2     10.1              -80.0      -16.7        24.7        -41.4          V

    0.139          52.7       0.2     10.1              -80.0      -17.0        24.7        -41.7          V

    0.140          53.9       0.2     10.1              -80.0      -15.8        24.7        -40.5          V

    0.140          53.6       0.2     10.1              -80.0      -16.1        24.7        -40.8          V


Test Method:     ANSI C63.4 (2003)                              NOTES:        V = Vertical Polarization
Spec Limit:      FCC Part 15 Subpart C Section 15.209
Test Distance:   3 Meters



COMMENTS: EUT is a hand held card transmitting at 139.6 kHz and is battery operated only.
The EUT is transmitting continuously with duty cycle during the test. Fresh batteries were
installed prior to test. Test distance correction factor applied in accordance with 15.31 of 40dB
per decade to correct test data for comparison to the limit. Measurements were performed over a
ground plane. Measurements include peak data for all modulation products within the 20dB
bandwidth of the device. EUT Testing in three orthogonal positions, indicated by X, Y and Z
notes. No EUT Emissions detected within 40dB of the limit. Frequency Range Investigated:
Carrier Upper Sideband (centered on 139 kHz). Temperature: 21.1ºC, Relative Humidity: 32%.




                                                                                                Page 7 of 24
                                                                                       Report No.: FC06-074


                          Table 2: FCC 15.209 Six Highest Radiated Emission Levels

                  METER        CORRECTION FACTORS               CORRECTED     SPEC
FREQUENCY        READING     Cable Ant         Corr              READING      LIMIT      MARGIN      NOTES
   MHz             dBµV       dB    dB         dB                 dBµV/m     dBµV/m        dB

    0.110          44.9        0.2    10.3              -40.0      -24.6       26.8        -51.4           V

    0.112          44.8        0.2    10.3              -40.0      -24.7       26.6        -51.3           V

    0.112          44.3        0.2    10.3              -40.0      -25.2       26.6        -51.8           V

    4.000          13.9        0.6    10.0              -40.0      -15.5       29.5        -45.0           H

    8.000           8.5        0.8    9.8               -40.0      -20.9       29.5        -50.4           H

    16.000          7.2        1.0    9.3               -40.0      -22.5       29.5        -52.0           H


Test Method:     ANSI C63.4 (2003)                              NOTES:       H = Horizontal Polarization
Spec Limit:      FCC Part 15 Subpart C Section 15.209                        V = Vertical Polarization
Test Distance:   3 Meters



COMMENTS: EUT is a hand held card transmitting at 139.6 kHz and is battery operated only.
The EUT is transmitting continuously with duty cycle during the test. Fresh batteries were
installed prior to test. Test distance correction factor applied in accordance with 15.31 of 40dB
per decade to correct test data for comparison to the limit. Measurements were performed over a
ground plane. Frequency Range Investigated: 9 kHz – 1000 MHz. No EUT emissions
detected in the frequency range of 30-1000 MHz. Temperature: 21.1ºC, Relative Humidity:
32%.




                                                                                               Page 8 of 24
                                                                                      Report No.: FC06-074


OCCUPIED BANDWIDTH




                              Page 9 of 24
                     Report No.: FC06-074


EUT SETUP
The equipment under test (EUT) was set up in a manner that represented its normal use, as
shown in the photographs in Appendix A. Any special conditions required for the EUT to
operate normally are identified in the comments that accompany the emissions tables. The
corrected data was then compared to the applicable emission limits to determine compliance.

The cables were routed consistent with the typical application by varying the configuration of the
test sample. Interface cables were connected to the available I/O ports of the test unit. The
effect of varying the position of the cables was investigated to find the configuration that
produced maximum emissions. I/O cables were of the type and length specified in the individual
requirements. The length of cable that produced maximum emissions was selected.

The radiated emissions data of the EUT was taken with the HP Spectrum Analyzer.
Incorporating the applicable correction factors for distance, antenna, cable loss and amplifier
gain, the data was reduced as shown in Table A.

Preliminary and final measurements were taken in order to ensure that all emissions from the
EUT were found and maximized.

CORRECTION FACTORS
The basic spectrum analyzer reading was converted using correction factors as shown in the
highest emissions readings in the tables. For radiated emissions in dBµV/m, the spectrum
analyzer reading in dBµV was corrected by using the following formula in Table A. This
reading was then compared to the applicable specification limit to determine compliance.

                            TABLE A: SAMPLE CALCULATIONS
                                Meter reading       (dBµV)
                            +   Antenna Factor      (dB)
                            +   Cable Loss          (dB)
                            -   Distance Correction (dB)
                            -   Preamplifier Gain   (dB)
                            =   Corrected Reading   (dBµV/m)




                                                                                       Page 10 of 24
                                                                               Report No.: FC06-074


TEST INSTRUMENTATION AND ANALYZER SETTINGS
The test instrumentation and equipment listed in Appendix B were used to collect the radiated
emissions data. For radiated measurements from 9 kHz to 30 MHz, the magnetic loop antenna was
used. For frequencies from 30 to 1000 MHz, the biconilog antenna was used. The horn antenna was
used for frequencies above 1000 MHz.

The HP spectrum analyzer was used for all measurements. Table B shows the analyzer
bandwidth settings that were used in designated frequency bands. During radiated testing, the
measurements were made with 0 dB of attenuation, a reference level of 97 dBµV, and a vertical
scale of 10 dB per division.

SPECTRUM ANALYZER DETECTOR FUNCTIONS
The notes that accompany the measurements contained in the Tables indicate the type of detector
function used to obtain the given readings. Unless otherwise noted, all readings were made in the
"Peak" mode. Whenever a "Quasi-Peak" or "Average" reading is listed as one of the six highest
readings, this is indicated as a "Q" or an "A" in the appropriate table. The following paragraphs
describe in more detail the detector functions and when they were used to obtain the emissions data.
Peak
In this mode, the Spectrum Analyzer or test engineer recorded all emissions at their peak value as the
frequency band selected was scanned. By combining this function with another feature of the
analyzer called "peak hold," the analyzer had the ability to measure transients or low duty cycle
transient emission peak levels. In this mode the analyzer made a slow scan across the frequency band
selected and measured the peak emission value found at each frequency across the band.
Quasi-Peak
When the true peak values exceeded or were within 2 dB of the specification limit, quasi-peak
measurements were taken using the HP Quasi-Peak Adapter for the HP Spectrum Analyzer. The
detailed procedure for making quasi peak measurements contained in the HP Quasi-Peak Adapter
manual were followed.
Average
For certain frequencies, average measurements may be made using the spectrum analyzer. To
make these measurements, the test engineer reduces the video bandwidth on the analyzer until
the modulation of the signal is filtered out. At this point the analyzer is set into the linear mode
and the scan time is reduced.




                                                                                          Page 11 of 24
                                                                                  Report No.: FC06-074


EUT TESTING

Radiated Emissions
The EUT was mounted on a nonconductive, rotating table 80 cm above the conductive grid. The
nonconductive table dimensions were 1 meter by 1.5 meters.

During the preliminary radiated scan, the EUT was powered up and operating in its defined FCC
test mode. For radiated measurements from 9 kHz to 30 MHz, the magnetic loop antenna was
used. The frequency range of 30 MHz to 1000 MHz was scanned with the biconilog antenna
located about 1.5 meter above the ground plane in the vertical polarity. During this scan, the
turntable was rotated and all peaks at or near the limit were recorded. A scan of the FM band
from 88 to 110 MHz was then made using a reduced resolution bandwidth and frequency span.
The biconilog antenna was changed to the horizontal polarity and the above steps were repeated.
Care was taken to ensure that no frequencies were missed within the FM and TV bands. An
analysis was performed to determine if the signals that were at or near the limit were caused by
an ambient transmission. If unable to determine by analysis, the equipment was powered down
to make the final determination if the EUT was the source of the emission.

A thorough scan of all frequencies was made manually using a small frequency span, rotating the
turntable and raising and lowering the antenna from one to four meters as needed. The test
engineer maximized the readings with respect to the table rotation, antenna height, and
configuration of EUT. Maximizing of the EUT was achieved by monitoring the spectrum
analyzer on a closed circuit television monitor.




                                                                                     Page 12 of 24
                                                                             Report No.: FC06-074


      APPENDIX A

TEST SETUP PHOTOGRAPHS




                                 Page 13 of 24
                         Report No.: FC06-074


PHOTOGRAPH SHOWING RADIATED EMISSIONS




        Radiated Emissions – Test Setup


                                                  Page 14 of 24
                                          Report No.: FC06-074


PHOTOGRAPH SHOWING RADIATED EMISSIONS




           Radiated Emissions - X




                                                Page 15 of 24
                                        Report No.: FC06-074


PHOTOGRAPH SHOWING RADIATED EMISSIONS




           Radiated Emissions - Y




                                                Page 16 of 24
                                        Report No.: FC06-074


PHOTOGRAPH SHOWING RADIATED EMISSIONS




           Radiated Emissions - Z




                                                Page 17 of 24
                                        Report No.: FC06-074


                                         APPENDIX B

                                    TEST EQUIPMENT LIST


 FCC 15.209 9 kHz – 30 MHz and Carrier
Function                S/N              Calibration Date   Cal Due Date   Asset #
Agilent E4446A SA       US44300407       01/12/2005         01/12/2007     02660
EMCO Loop Antenna       1074             05/13/2005         05/13/2007     00226

 FCC 15.209 30-1000 MHz
Function              S/N                Calibration Date   Cal Due Date   Asset #
Agilent E4446A SA     US44300407         01/12/2005         01/12/2007     02660
Chase CBL6111C Bilog 2456                06/07/2005         06/07/2007     01991
HP 8447D Preamp       1937A02604         03/11/2005         03/11/2007     00099




                                                                                    Page 18 of 24
                                                                            Report No.: FC06-074


      APPENDIX C:

MEASUREMENT DATA SHEETS




                                  Page 19 of 24
                          Report No.: FC06-074


Test Location:      CKC Laboratories •4933 Sierra Pines Dr. • Mariposa, CA 95338 • 1-800-500-4EMC (4362)
Customer:           HID Global
Specification:      FCC 15.209
Work Order #:       85557                                                Date: 11/20/2006
Test Type:          Maximized Emissions                                 Time: 14:13:14
Equipment:          ProxPass II                                   Sequence#: 3
Manufacturer:       HID Global                                     Tested By: Randal Clark
Model:              1351
S/N:                111706
 Equipment Under Test (* = EUT):
Function                  Manufacturer                     Model #                     S/N
ProxPass II*              HID Global                       1351                        111706
 Support Devices:
Function                        Manufacturer               Model #                     S/N
 Test Conditions / Notes:
EUT is a hand held card transmitting at 139.6 kHz and is battery operated only. The EUT is transmitting
continuously with duty cycle during the test. Fresh batteries were installed prior to test. Test distance correction
factor applied in accordance with 15.31 of 40dB per decade to correct test data for comparison to the limit.
Measurements were performed over a ground plane. Measurements include peak data for all modulation products
within the 20dB bandwidth of the device. EUT Testing in three orthogonal positions, indicated by X, Y and Z
notes. No EUT Emissions detected within 40dB of the limit. Frequency Range Investigated: Carrier Upper
Sideband (centered on 139 kHz). Temperature: 21.1ºC, Relative Humidity: 32%.
 Transducer Legend:
T1=Cable - Site D 10m 9k-1G                                T2=Mag Loop - AN 00226 - 9kHz-30M
T3=15.31 3m 40dB/Dec Correction

Measurement Data:       Reading listed by margin.                        Test Distance: 3 Meters
 #      Freq      Rdng     T1        T2      T3                      Dist     Corr       Spec    Margin     Polar
        MHz       dBµV     dB        dB      dB             dB       Table dBµV/m dBµV/m           dB        Ant
   1 140.316k       53.9    +0.2 +10.1        -80.0                   +0.0    -15.8       24.7    -40.5     Verti
                                                                                      X                      100
    2    137.754k        53.8      +0.2   +10.1    -80.0              +0.0    -15.9       24.8    -40.7     Verti
                                                                                      X                      100
    3    140.309k        53.6      +0.2   +10.1    -80.0              +0.0    -16.1       24.7    -40.8     Verti
                                                                                      Z                      100
    4    137.740k        53.2      +0.2   +10.1    -80.0              +0.0    -16.5       24.8    -41.3     Verti
                                                                                      Z                      100
    5    139.042k        53.0      +0.2   +10.1    -80.0              +0.0    -16.7       24.7    -41.4     Verti
                                                                                      X                      100
    6    139.028k        52.7      +0.2   +10.1    -80.0              +0.0    -17.0       24.7    -41.7     Verti
                                                                                      Z                      100
    7    140.295k        49.3      +0.2   +10.1    -80.0              +0.0    -20.4       24.7    -45.1     Horiz
                                                                                      X                      100
    8    137.747k        49.2      +0.2   +10.1    -80.0              +0.0    -20.5       24.8    -45.3     Horiz
                                                                                      X                      100
    9    141.590k        48.7      +0.2   +10.1    -80.0              +0.0    -21.0       24.6    -45.6     Verti
                                                                                      X                      100
   10    141.590k        48.5      +0.2   +10.1    -80.0              +0.0    -21.2       24.6    -45.8     Verti
                                                                                      Z                      100


                                                                                                        Page 20 of 24
                                                                                                Report No.: FC06-074


11   140.309k   48.6   +0.2   +10.1   -80.0   +0.0   -21.1       24.7       -45.8   Horiz
                                                             Z                       100
12   137.754k   48.5   +0.2   +10.1   -80.0   +0.0   -21.2       24.8       -46.0   Horiz
                                                             Z                       100
13   139.042k   48.3   +0.2   +10.1   -80.0   +0.0   -21.4       24.7       -46.1   Horiz
                                                             X                       100
14   139.035k   47.8   +0.2   +10.1   -80.0   +0.0   -21.9       24.7       -46.6   Horiz
                                                             Z                       100
15   136.487k   47.9   +0.2   +10.1   -80.0   +0.0   -21.8       24.9       -46.7   Verti
                                                             X                       100
16   136.494k   47.4   +0.2   +10.1   -80.0   +0.0   -22.3       24.9       -47.2   Verti
                                                             Z                       100
17   141.583k   44.8   +0.2   +10.1   -80.0   +0.0   -24.9       24.6       -49.5   Horiz
                                                             X                       100
18   141.583k   44.2   +0.2   +10.1   -80.0   +0.0   -25.5       24.6       -50.1   Horiz
                                                             Z                       100
19   136.466k   43.8   +0.2   +10.1   -80.0   +0.0   -25.9       24.9       -50.8   Horiz
                                                             X                       100
20   136.480k   43.4   +0.2   +10.1   -80.0   +0.0   -26.3       24.9       -51.2   Horiz
                                                             Z                       100
21   137.740k   40.7   +0.2   +10.1   -80.0   +0.0   -29.0       24.8       -53.8   Verti
                                                             Y                       100
22   140.309k   40.3   +0.2   +10.1   -80.0   +0.0   -29.4       24.7       -54.1   Verti
                                                             Y                       100
23   139.028k   40.0   +0.2   +10.1   -80.0   +0.0   -29.7       24.7       -54.4   Verti
                                                             Y                       100
24   141.597k   36.7   +0.2   +10.1   -80.0   +0.0   -33.0       24.6       -57.6   Verti
                                                             Y                       100
25   136.473k   36.3   +0.2   +10.1   -80.0   +0.0   -33.4       24.9       -58.3   Verti
                                                             Y                       100
26   139.000k   31.6   +0.2   +10.1   -80.0   +0.0   -38.1       24.7       -62.8   Horiz
                                                             Y - No EUT signals      100
                                                             detected in this
                                                             configuration.




                                                                                Page 21 of 24
                                                                        Report No.: FC06-074


Test Location:      CKC Laboratories •4933 Sierra Pines Dr. • Mariposa, CA 95338 • 1-800-500-4EMC (4362)

Customer:           HID Global
Specification:      FCC 15.209
Work Order #:       85557                                                Date:    11/20/2006
Test Type:          Maximized Emissions                                  Time:    12:30:09
Equipment:          ProxPass II                                     Sequence#:    2
Manufacturer:       HID Global                                      Tested By:    Randal Clark
Model:              1351
S/N:                111706
 Equipment Under Test (* = EUT):
Function                  Manufacturer                        Model #                        S/N
ProxPass II*              HID Global                          1351                           111706
 Support Devices:
Function                        Manufacturer                  Model #                        S/N
 Test Conditions / Notes:
EUT is a hand held card transmitting at 139.6 kHz and is battery operated only. The EUT is transmitting
continuously with duty cycle during the test. Fresh batteries were installed prior to test. Test distance correction
factor applied in accordance with 15.31 of 40dB per decade to correct test data for comparison to the limit.
Measurements were performed over a ground plane.            Frequency Range Investigated: 9 kHz – 30 MHz
Temperature: 21.1ºC, Relative Humidity: 32%.
 Transducer Legend:
T1=Cable - Site D 10m 9k-1G                                   T2=Mag Loop - AN 00226 - 9kHz-30M
T3=15.31 3m 40dB/Dec Correction

Measurement Data:       Reading listed by margin.                           Test Distance: 3 Meters
 #      Freq      Rdng     T1        T2      T3                         Dist     Corr       Spec    Margin        Polar
        MHz       dBµV     dB        dB      dB                dB       Table dBµV/m dBµV/m           dB           Ant
   1    4.000M      13.9    +0.6 +10.0        -40.0                      +0.0    -15.5       29.5    -45.0        Horiz

    2     8.000M          8.5      +0.8        +9.8   -40.0              +0.0    -20.9        29.5        -50.4   Horiz

    3    112.225k        44.8      +0.2   +10.3       -80.0              +0.0    -24.7        26.6        -51.3   Verti
                                                                                         X
    4    109.695k        44.9      +0.2   +10.3       -80.0              +0.0    -24.6        26.8        -51.4   Verti
                                                                                         Z
    5    112.245k        44.3      +0.2   +10.3       -80.0              +0.0    -25.2        26.6        -51.8   Verti
                                                                                         Z
    6    16.000M          7.2      +1.0        +9.3   -40.0              +0.0    -22.5        29.5        -52.0   Horiz

    7    12.000M          6.7      +1.0        +9.7   -40.0              +0.0    -22.6        29.5        -52.1   Horiz

    8    109.685k        43.8      +0.2   +10.3       -80.0              +0.0    -25.7        26.8        -52.5   Verti
                                                                                         X




                                                                                                              Page 22 of 24
                                                                                                      Report No.: FC06-074


 9   110.970k   43.7   +0.2   +10.3   -80.0   +0.0   -25.8       26.7       -52.5   Verti
                                                             Z
10   110.965k   43.4   +0.2   +10.3   -80.0   +0.0   -26.1       26.7       -52.8   Verti
                                                             X
11   113.520k   40.4   +0.2   +10.3   -80.0   +0.0   -29.1       26.5       -55.6   Verti
                                                             X
12   125.000k   29.7   +0.2   +10.2   -80.0   +0.0   -39.9       25.7       -65.6   Verti
                                                             Z




                                                                                Page 23 of 24
                                                                        Report No.: FC06-074


Test Location:      CKC Laboratories •4933 Sierra Pines Dr. • Mariposa, CA 95338 • 1-800-500-4EMC (4362)

Customer:           HID Global
Specification:      FCC 15.209
Work Order #:       85557                                             Date:   11/20/2006
Test Type:          Maximized Emissions                               Time:   15:44:43
Equipment:          ProxPass II                                  Sequence#:   8
Manufacturer:       HID Global                                   Tested By:   Randal Clark
Model:              1351
S/N:                111706
 Equipment Under Test (* = EUT):
Function                  Manufacturer                   Model #                     S/N
ProxPass II*              HID Global                     1351                        111706
 Support Devices:
Function                     Manufacturer                Model #                     S/N
 Test Conditions / Notes:
EUT is a hand held card transmitting at 139.6 kHz and is battery operated only. The EUT is transmitting
continuously with duty cycle during the test. Fresh batteries were installed prior to test. No EUT emissions
detected in this frequency range. Frequency Range Investigated: 30-1000 MHz. Temperature: 21.1ºC, Relative
Humidity: 32%.
Transducer Legend:


Measurement Data:      Reading listed by margin.                       Test Distance: 3 Meters
 #      Freq      Rdng                                             Dist     Corr       Spec    Margin      Polar
        MHz       dBµV    dB        dB      dB             dB      Table dBµV/m dBµV/m          dB          Ant




                                                                                                      Page 24 of 24
                                                                                              Report No.: FC06-074



Document Created: 2006-12-01 15:38:57
Document Modified: 2006-12-01 15:38:57