Cover Letters Summary of Responses for Additional Informatio

FCC ID: JQ61351

Cover Letter(s)

Download: PDF
FCCID_129824

Responses to Non-Conformities (Ref # E00-000502-1)


Item 1: Please provide a label showing the correct FCC ID
        number as stated on the 731 form (FCC ID: JQ61351A).

        FROM: CKC Laboratories Inc.
        DATE: 11/09/2000 09:13:29
        Items 1 & 2 - please revise the 731 form for the FCC ID#
        to read JQ61351.

Item 2: The FCC ID mentioned in the Users Manual does not
        match with what is stated on the 731 form. Please correct
        accordingly.

        FROM: CKC Laboratories Inc.
        DATE: 11/09/2000 09:13:29
        Items 1 & 2 - please revise the 731 form for the FCC ID#
        to read JQ61351.



Item 3: From the test data provided it appears that some of the
        spurious emissions readings in the six highest table are
        higher than the fundamental reading.           Spurious
        emissions cannot be higher than the fundamental
        regardless if all emissions comply. Please explain and
        correct and/or retest if necessary.

        FROM: CKC Laboratories Inc.
        DATE: 11/09/2000 09:13:29

        Item 3 - addendum test report FC99-038B has been
        uploaded to reflect corrected spurious emissions data.
        Joyce Walker Report Deparment Manager CKC
        Laboratories Inc.


Responses to Non-Conformities           (Ref # E00-000502-2)
FCC ID: JQ661351


Item 1: Spurious emissions cannot be higher than the
        fundamental regardless if all emissions comply. Please
        explain and correct and/or retest if necessary.

FROM: CKC Laboratories Inc.
DATE: Wednesday, December 06, 2000 10:04:37 AM
Uploaded CKC Test Report FC99-038C. Combined original testing
with revised test data into one comprehensive report.Explanation
of revised data is on page 3.



Document Created: 2000-12-20 17:27:00
Document Modified: 2000-12-20 17:27:00