Test Report Funda

FCC ID: JQ60006A

Test Report

Download: PDF
FCCID_169154

Test Location:       CKC Laboratories, Inc. • 5473A Clouds Rest • Mariposa, CA 95338 • 800-500-4362

Customer:            HID
Specification:       FCC 15.209
Work Order #:        77304                                                    Date:       07/19/2001
Test Type:           Maximized Emissions                                      Time:       10:54:53
Equipment:           Proximity Card Reader                               Sequence#:       2
Manufacturer:        HID                                                 Tested By:       Randal Clark
Model:               5455/8B (5455-310)
S/N:                 2901-2
 Test Equipment:
Function                 S/N                        Calibration Date          Cal Due Date                 Asset #
Spectrum Analyzer RF     2209A01404                 11/03/2000                11/03/2001                   490
Section
Spectrum Analyzer        2403A08241                 11/03/2000                11/03/2001                   489
Display
QP Adapter               2811A01267                 11/03/2000                11/03/2001                   478
Preamplifier             1937A02604                 03/29/2001                03/29/2002                   0
Log Periodic             154                        05/07/2001                05/07/2002                   0
Biconical Antenna        156                        12/18/2000                12/18/2001                   0
 Equipment Under Test (* = EUT):
Function                     Manufacturer                        Model #                          S/N
Proximity Card Reader*       HID                                 5455/8B (5455-310)               2901-2
 Support Devices:
Function                          Manufacturer                   Model #                          S/N
Power Supply                      Topward Electric Instruments   TPS-2000                         920035
 Test Conditions / Notes:
EUT is a proximity card reader operating on a frequency of 125kHz. EUT is powered by 12VDC though a DC power supply.
EUT is operating in normal mode with no card in the field. Frequency Range Tested: 125kHz.
Measurement Data:            Reading listed by order taken.                         Test Distance: 10 Meters
                                Loop       Cable      15.31
  #         Freq        Rdng                                                Dist       Corr       Spec           Margin   Polar
           MHz          dBµV         dB        dB       dB        dB        Table     dBµV/m     dBµV/m            dB     Ant
      1   126.073k        63.9       +10.1      +0.1     -60.0               +0.0       14.1       25.6           -11.5   Vert

      2   126.051k         45.5      +10.1      +0.1     -60.0              +0.0         -4.3       25.6          -29.9   Horiz



Document Created: 2019-06-04 10:30:36
Document Modified: 2019-06-04 10:30:36

© 2024 FCC.report