MPE Calculation

FCC ID: JQ6-OK5127CKMINI

RF Exposure Info

Download: PDF
FCCID_2574015

                                                       MPE CALCULATION
_____________________________________________________________________________________________________________________

RF Exposure Requirements:                                                       47 CFR §1. 1307(b)

RF Radiation Exposure Limits:                                                   47 CFR §1. 1310

RF Radiation Exposure Guidelines:                                               FCC OST/OET Bulletin Number 65

EUT Frequency Band:                                                             2402 - 2480 MHz
Limits for General Population/Uncontrolled Exposure in the band of:             1500 - 100,000 MHz
Power Density Limit:                                                            1 mW / cm2
Equation:          S = PG / 4R2 or R = √PG / 4S
         Where,    S = Power Density
                   P = Power Input to Antenna
                   G = Antenna Gain
                   R = distance to the center of radiated antenna
______________________________________________________________________________________________________________________
Prediction distance 20cm

                  Power = 1.009 mW (Maximum peak output power),
                  Antenna Gain = 3 dBi (Numerical Antenna; equal to 4.0 dBi)
                  Power density = 0.00057 mW/ cm2

         Mode             Prediction          Target           Tune up power    Max Tune up       Max Antenna    Power density
                        distance (cm)       Power (dBm)        tolerance (dB)   Power (dBm)        Gain (dBi)      (mW/ cm2)
   DTS band BT LE             20               0.04                  1.5           1.54                3            0.00057
  Note: The MPE value is calculated on the channel with the worst case scenario. In this case low channel is investigated.


In conclusion, SAR is not required. The maximum power density is 0.00057 mW/ cm2, which is less than 1 mW/ cm2.
The Above Result had shown that the Device complied with MPE requirement.


Completed By:



Osvaldo Casorla
SIEMIC, Inc
775 Montague Expressway, Milpitas, CA 95035
Phone: (408) 526-1188


Date: April 01, 2015



Document Created: 2015-04-01 16:31:15
Document Modified: 2015-04-01 16:31:15