 Report No.: RF_SL14092201-HID-028_FCC-IC OK5021 Rev. 1.0
 Supersede Report No.: RF_SL14092201-HID-028_FCC-IC OK5021


 Applicant          HID Global Corporation
 Product Name       Smart Card Reader
 Model No.          OMNIKEY OK5021 CL
                    47 CRF 15.225: 2014
 Test Standard
                    RSS-210 Issue 8: 2010
                    ANSI C63.10: 2009
 Test Method
                    RSS Gen 4.9
 FCC ID             JQ6-OK5021CL
 IC ID              2236B-OK5021CL
 Date of test       10/27/2014-10/29/2014
 Issue Date         11/03/2014
 Test Result        Pass                Fail
 Equipment complied with the specification                      [x]
 Equipment did not comply with the specification                [ ]




                    Teody Manansala                                                 David Zhang
                     Test Engineer                                                Engineer Reviewer
                                    This test report may be reproduced in full only
                    Test result presented in this test report is applicable to the tested sample only


                                                  Issued By:
                                             SIEMIC Laboratories
                                  775 Montague Expressway, Milpitas, 95035 CA




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                   Test report No.     RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                                   Page                2 of 20




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
          Country/Region                 Accreditation Body                                      Scope
                USA                           FCC, A2LA                                EMC, RF/Wireless, Telecom
             Canada                        IC, A2LA, NIST                              EMC, RF/Wireless, Telecom
              Taiwan                      BSMI, NCC, NIST                               EMC, RF, Telecom, Safety
            Hong Kong                        OFTA, NIST                                   RF/Wireless, Telecom
             Australia                       NATA, NIST                                 EMC, RF, Telecom, Safety
              Korea                        KCC/RRA, NIST                              EMI, EMS, RF, Telecom, Safety
              Japan                    VCCI, JATE, TELEC, RFT                          EMI, RF/Wireless, Telecom,
              Mexico                   NOM, COFETEL, Caniety                         EMC, RF/Wireless, Telecom, Safety
              Europe                          A2LA, NIST                                EMC, RF, Telecom, Safety
               Israel                         MOC, NIST                                 EMC, RF, Telecom, Safety

                                    Accreditations for Product Certifications
              Country                      Accreditation Body                                    Scope
                USA                          FCC TCB, NIST                                  EMC, RF, Telecom
              Canada                          IC FCB, NIST                                  EMC, RF, Telecom
             Singapore                          iDA, NIST                                   EMC, RF, Telecom
                EU                                 NB                                     EMC & R&TTE Directive
               Japan                         MIC (RCB 208)                                    RF, Telecom
             Hong Kong                       OFTA (US002)                                     RF, Telecom



          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                Test report No.      RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                                                Page                 3 of 20




CONTENTS
1      REPORT REVISION HISTORY ....................................................................................................................... 4
2      EXECUTIVE SUMMARY ................................................................................................................................ 5
3      CUSTOMER INFORMATION .......................................................................................................................... 5
4      TEST SITE INFORMATION ............................................................................................................................ 5
5      MODIFICATION ............................................................................................................................................ 5
6      EUT INFORMATION ...................................................................................................................................... 6
    6.1 EUT Description ........................................................................................................................................ 6
    6.2 Radio Description ...................................................................................................................................... 6
    6.3 EUT test modes/configuration Description ................................................................................................... 6
    6.4 EUT External Photos ................................................................................................................................. 7
    6.5 EUT Internal Photos .................................................................................................................................. 8
    6.6 EUT Test Setup Photos ............................................................................................................................. 9
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION ...................................................... 10
    7.1 Supporting Equipment ............................................................................................................................. 10
    7.2 Test Software Description ........................................................................................................................ 10
8      TEST SUMMARY ........................................................................................................................................ 11
9      MEASUREMENT UNCERTAINTY ................................................................................................................ 12
10         MEASUREMENTS, EXAMINATION AND DERIVED RESULTS .................................................................. 13
    10.1       Radiated Spurious Emissions below 30 MHz ......................................................................................... 13
    10.2       Radiated Spurious Emissions 30 MHz – 1000MHz ................................................................................. 15
ANNEX A. TEST INSTRUMENT.......................................................................................................................... 17
ANNEX B. USER MANUAL, BLOCK & CIRCUIT DIAGRAM.................................................................................. 18
ANNEX C. SIEMIC ACCREDITATION .................................................................................................................. 19




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                       Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                            Page              4 of 20




1   Report Revision History

                                                          Report
                   Report No.                                                     Description               Issue Date
                                                          Version
   RF_SL14092201-HID-028_FCC-IC_OK5021                     None                     Original                11/03/2014
RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0                1.0               Change test standard          11/12/2014
                                                                            Change equipment class
                                                                              Change test distance
                                                                           Add table and remarks for
                                                                          below 30MHz test procedure




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                             Page              5 of 20




2    Executive Summary

The purpose of this test program was to demonstrate compliance of following product
 Company:       HID Global Corporation
 Product:       Smart Card Reader
 Model:         OMNIKEY OK5021 CL

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with
the Stipulated Standard listed on 1st page.


3    Customer information

 Applicant Name                         HID Global Corporation
 Applicant Address                      15370 Barranca Parkway, Irvine, CA 92618 USA
 Manufacturer Name                      HID Global Corporation
 Manufacturer Address                   15370 Barranca Parkway, Irvine, CA 92618 USA


4    Test site information

 Lab performing tests                   SIEMIC Laboratories
 Lab Address                            775 Montague Expressway, Milpitas, CA 95035
 FCC Test Site No.                      881796
 IC Test Site No.                       4842D-2
 VCCI Test Site No.                     A0133


5    Modification

                Index                           Item                           Description                     Note
                  -                               -                                 -                            -




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                             Page              6 of 20




6     EUT Information

6.1    EUT Description

 Product Name                           Smart Card Reader
 Model No.                              OMNIKEY OK5021 CL
 Trade Name                             HID
 Serial No.                             N/A
 Input Power                            N/A
 Power Adapter Manu/Model               N/A
 Power Adapter SN                       N/A
 Hardware version                       N/A
 Software version                       N/A
 Date of EUT received                   10/27/2014
 Equipment Class/ Category               DXX
 Operating Frequencies                  13.56 MHz
 Port/Connectors                        N/A


6.2    Radio Description

Spec for Radio -
            Radio Type
Operating Frequency                    13.56 MHz(RFID)
Modulation                             ASK (13.56MHz)
Channel Spacing                        N/A
Number of Channels                     1(RFID)
Antenna Type                           Inductive Loop Antenna
Antenna Gain                           1dBi
Antenna Connector Type                 N/A


6.3    EUT test modes/configuration Description

                                              Test Mode                                                       Note
         Pre_test_mode_1                                   RFID Continuous Transmit                            -
         Pre_test_mode_2                                              -                                        -
         Pre_test_mode_3                                              -                                        -




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                            Page              7 of 20




6.4   EUT External Photos




                   EUT– Front View                                                   EUT – Rear View




                   EUT – Top View                                                  EUT – Bottom View




                 EUT – Left Side View                                             EUT – Right Side View




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.     RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                            Page                8 of 20




6.5   EUT Internal Photos




                    OK5021 PCBA - Top View                                    OK5021 PCBA - Bottom View




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                             Page              9 of 20




6.6    EUT Test Setup Photos




        Radiated Emissions (<30MHz) – Front View                           Radiated Emissions (<30MHz) – Rear View




      Radiated Emissions (30MHz-1GHz) – Front View                       Radiated Emissions (30MHz-1GHz) – Rear View




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.     RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                                Page                10 of 20




7     Supporting Equipment/Software and cabling Description

7.1       Supporting Equipment

                Supporting Equipment
    Item                                              Model                 Serial Number          Manufacturer        Note
                    Description
      1                Laptop                     Latitude D600                   920027                Dell             -




7.2       Test Software Description

           Test Item                       Software                                         Description
               -                               -                                                 -




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                                 Page              11 of 20




8    Test Summary

        Test Item                    Test standard                           Test Method/Procedure                        Pass / Fail

    Radiated Spurious          FCC            15.209           FCC                 ANSI C63.10 – 2009                     ☒ Pass
       Emissions               IC        RSS 210(A8.5)           IC                     RSS Gen 4.9                       ☐ N/A
                        1.   All measurement uncertainties do not take into consideration for all presented test results.
    Remark              2.   The applicant shall ensure frequency stability by showing that an emission is maintained within the band
                             of operation under all normal operating conditions as specified in the user’s manual.




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                             Page              12 of 20




9    Measurement Uncertainty

                                                       Emissions
             Test Item                   Frequency Range                         Description                   Uncertainty
                                                                 Confidence level of approximately 95% (in
                                                                 the case where distributions are normal),       +5.6dB/-
    Radiated Spurious Emissions           150 kHz – 1GHz
                                                                  with a coverage factor of 2 (for EUTs <         4.5dB
                                                                           0.5m X 0.5m X 0.5m)
                                                                 Confidence level of approximately 95% (in
                                                                 the case where distributions are normal),       +4.3dB/-
    Radiated Spurious Emissions            1GHz – 40GHz
                                                                  with a coverage factor of 2 (for EUTs <         4.1dB
                                                                           0.5m X 0.5m X 0.5m)




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                               Page              13 of 20




10 Measurements, Examination and Derived Results

10.1 Radiated Spurious Emissions below 30 MHz
Requirement(s):
Spec                 Requirement                                                                                Applicable

                     The field strength of any emissions appearing outside of the 13.110–14.010 MHz
                     band shall not exceed the general radiated emission limits in § 15.225.
                                                                                       Measurement
                       Frequency range (MHz)           Field Strength (uV/m)
                                                                                         Distance
47 CFR § 15.225                0.009-0.490                  2400/F(KHz)                      300
                                                                                                                      ☒
RSS-210 (A2.6)                 0.490-1.705                  2400/F(KHz)                      30
                               1.705-30.00                       30                          30
                               30.00-88.00                      100                           3
                               88.00-216.00                     150                           3
                              216.00-960.00                     200                           3
                                Above 960                       500                           3




  Test Setup




                     For < 30MHz, Radiated emissions were measured according to ANSI C63.4. The EUT was set to
                     transmit at the highest output power.
   Procedure         The EUT was set 10 meter away from the measuring antenna. The loop antenna was positioned 1
                     meter above the ground from the centre of the loop. The measuring bandwidth was set to 10 kHz.
                     The limit is converted from microvolt/meter to decibel microvolt/meter.

                     Limit calculation example:
                      Frequency = 0.8 MHz, limit @ 30m = 24000/800=30uV/m=29.5424 dBuV/m
    Remark            To convert the limit from 30m to 10m, use following formula
                      Limit @ 10m = Limit @ 30m + 40 log (30/10)
                      Frequency = 0.8 MHz, limit @ 10m = 29.5424 + 19.0848 = 48.6272 dBuV/m
       Result        ☒ Pass             ☐ Fail


Test Data       ☒ Yes (See below)            ☐ N/A

Test Plot       ☒ Yes (See below)           ☒ N/A



          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                                  Test report No.    RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                                  Page               14 of 20




  Test specification:                  Radiated Spurious Emissions (below 30MHz)
                                       Temp(° C):             26
Environmental Conditions:              Humidity (%):          45.6
                                                                                                                       ☒ Pass
                                       Atmospheric(mbar):     1021
                                                                                                        Result:
Mains Power:                           120VA, 60Hz
                                       Teody Manansala                                                                  ☐ Fail
Tested by:
Test Date:                             10/27/2014
Remarks:                               OK5021 at 0 degrees and 90 degrees


Loop Antenna

Loop antenna at 0 degrees
                                    Total
       Frequency         Raw                  Level      Measurement           Hgt     Azt       Limit      Margin   Pass
                                    Loss
         (MHz)          (dBuV)              (dBuV/m)        Type              (cm)    (Deg)    (dBuV/m)      (dB)    /Fail
                                    (dB)
           0.86         31.19      11.23      42.42       Quasi Max        100.00     95.00     47.99        -5.57   Pass
           0.55         29.19      14.95      44.14       Quasi Max        100.00     80.00     51.84        -7.70   Pass
           0.81         31.13      11.71      42.84       Quasi Max        100.00     56.00     48.52        -5.68   Pass

Loop antenna at 90 Degrees
                                   Total
       Frequency         Raw                  Level     Measurement            Hgt     Azt       Limit      Margin   Pass
                                   Loss
         (MHz)          (dBuV)              (dBuV/m)       Type               (cm)    (Deg)    (dBuV/m)      (dB)    /Fail
                                   (dB)
          0.86          31.47      11.24      42.71       Quasi Max       100.00 134.00          48.00       -5.29   Pass
          0.81          30.56      11.70      42.26       Quasi Max       100.00 172.00          48.51       -6.25   Pass
          0.55          29.45      14.98      44.43       Quasi Max       100.00 176.00          51.87       -7.44   Pass




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.    RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                               Page               15 of 20




10.2 Radiated Spurious Emissions 30 MHz – 1000MHz

Requirement(s):
 Spec                  Item   Requirement                                                                       Applicable
                       a)
                              Except higher limit as specified elsewhere in other section, the emissions        ☒
                              from the low-power radio-frequency devices shall not exceed the field
                              strength levels specified in the following table and the level of any
                              unwanted emissions shall not exceed the level of the fundamental
 47CFR§ 15.209,               emission. The tighter limit applies at the band edges
  RSS210(A8.5)                       Frequency range (MHz)                       Field Strength (uV/m)
                                             30 – 88                                      100
                                            88 – 216                                      150
                                            216 960                                       200
                                           Above 960                                      500




   Test Setup




                       1.       The EUT was switched on and allowed to warm up to its normal operating condition.
                       2.       The test was carried out at the selected frequency points obtained from the EUT
                                characterisation. Maximization of the emissions, was carried out by rotating the EUT,
                                changing the antenna polarization, and adjusting the antenna height in the following
                                manner:
                                a.       Vertical or horizontal polarisation (whichever gave the higher emission level over a
    Procedure                            full rotation of the EUT) was chosen.
                                b.       The EUT was then rotated to the direction that gave the maximum emission.
                                c.       Finally, the antenna height was adjusted to the height that gave the maximum
                                         emission.
                       3.       A Quasi-peak measurement was then made for that frequency point.
                       4.       Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points
                                were measured.

     Remark

        Result         ☒ Pass            ☐ Fail

Test Data        ☒ Yes (See below)           ☐ N/A

Test Plot        ☒ Yes (See below)           ☐ N/A



          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                                Page              16 of 20




Test specification:                  Radiated Spurious Emissions (30MHz – 1000MHz)
                                     Temp(° C):             23.7
Environmental Conditions:            Humidity (%):          44.9
                                                                                                                    ☒ Pass
                                     Atmospheric(mbar):     1021
                                                                                                    Result:
Mains Power:                         120VA, 60Hz
                                                                                                                     ☐ Fail
Tested by:                           Teody Manansala
Test Date:                           10/29/2014
Remarks:                             OK5021




                       Cable
Frequency      Raw                 AF        Level     Measurement        Pol       Hgt     Azt        Limit    Margin    Pass
                       Loss
  (MHz)       (dBuV)              (dB)     (dBuV/m)       Type           (V/H)     (cm)    (Deg)     (dBuV/m)    (dB)     /Fail
                       (dB)
 40.42        56.60     1.20     -26.10     31.70       Quasi Peak.         V     104.00   257.00     40.00      -8.30    Pass
 46.50        55.79     1.16     -28.51     28.44       Quasi Max           V     152.00   254.00     40.00     -11.56    Pass
 311.89       60.77     3.04     -25.89     37.93       Quasi Max           H     100.00   207.00     46.00      -8.07    Pass
 180.05       50.20     2.40     -28.88     23.72       Quasi Max           H     246.00   126.00     43.50     -19.78    Pass
 284.78       61.71     2.94     -26.49     38.16       Quasi Max           H     110.00   265.00     46.00      -7.84    Pass
 80.87        50.35     1.52     -31.66     20.21       Quasi Max           V     138.00   259.00     40.00     -19.79    Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                            Page              17 of 20




Annex A. TEST INSTRUMENT

        Instrument                    Model            Serial #          Cal Date      Cal Cycle      Cal Due      In use
    Radiated Emissions
       R & S Receiver                 ESL6             100178           03/04/2014       1 Year     03/04/2015
       R & S Receiver                ESIB 40           100179           05/24/2014       1 Year     05/24/2015
 ETS-Lingren Loop Antenna              6512           00049120          08/22/2014       1 Year     08/22/2015
Bi-Log antenna (30MHz~2GHz)            JB1            A030702           08/12/2014       1 Year     08/12/2015
 Horn Antenna (1-26.5GHz)              3115           10SL0059          04/26/2014       1 Year     04/26/2015
  Pre-Amplifier (1-26.5GHz)           8449B         3008A00715          05/30/2014       1 Year     05/30/2015
Microwave Preamplifier (18-40
                                     PA-840            181251           05/30/2014       1 Year     05/30/2015
           GHz)
       3 Meters SAC                     3M               N/A            10/13/2014       1 Year     10/13/2015
       10 Meters SAC                   10M               N/A            06/05/2014       1 Year     06/05/2015
 Sekonic Hygro Hermograph             ST-50         HE01-000092         05/25/2014       1 Year     05/25/2015




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                          Page              18 of 20




Annex B. USER MANUAL, BLOCK & CIRCUIT DIAGRAM

                                              Please see attachment




     775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                         Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.     RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                               Page                19 of 20




Annex C. SIEMIC Accreditation

        Accreditations         Document                                          Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio & Telecommunications Terminal Equipment:
                                           EN45001 – EN ISO/IEC 17025
EU NB
                                           Electromagnetic Compatibility:
                                           EN45001 – EN ISO/IEC 17025

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
Hong Kong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.   RF_SL14092201-HID-028_FCC-IC_OK5021 Rev. 1.0
                                                                Page              20 of 20




                                           Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                           Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                           1 of the Radio Law

                                           EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                           KN22: Test Method for EMI
                                           EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                           KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                    Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                           RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                           80, RRL Notice 2004-68

                                           Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                           attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                           LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                           PLMN08

Taiwan BSMI CAB Recognition                CNS 13438

                                           R-3083: Radiation 3 meter site
Japan VCCI                                 C-3421: Main Ports Conducted Interference Measurement
                                           T-1597: Telecommunication Ports Conducted Interference Measurement

                                           EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                           61000.6.3, AS/NZS 61000.6.4

                                           Radio communications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                           AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                           AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                           Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                           AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                           AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                           AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                 S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF