Test Report

FCC ID: JQ6-BCC101

Test Report

Download: PDF
FCCID_3048048

RF TEST
REPORT

Report No.: FCC_IC_RF_SL16041201-HID-019
Supersede Report No.: NONE

  Applicant                :
                        HID Global Corporation
  Product Name             :
                        USB Coupler
  Model No.                :
                        BCC101
                        FCC 15.225
  Test Standard       :
                        RSS-210 Issue 8: 2010
                        FCC 15.225
  Test Method         : ANSI C63.10 2013
                        RSS Gen Issue 4 2014
  FCC ID              : JQ6-BCC101
  IC ID               : 2236B-BCC101
  Dates of test       : 05/31/2016 to 06/07/2016
  Issue Date          : 06/10/2016
  Test Result         : ☒ Pass            ☐ Fail
  Equipment complied with the specification                               [X ]
  Equipment did not comply with the specification                          [ ]


  This Test Report is Issued Under the Authority of:




                     Teody Manansala                                                          Chen Ge
                        Test Engineer                                                     Engineer Reviewer
                                           This test report may be reproduced in full only
                           Test result presented in this test report is applicable to the tested sample only



                                                   Issued By:
                                              SIEMIC Laboratories
                                   775 Montague Expressway, Milpitas, CA 95035




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.       FCC_IC_RF_SL16041201-HID-019
                                                          Page                  2 of 33




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
           Country/Region                  Accreditation Body                                   Scope
                 USA                            FCC, A2LA                             EMC, RF/Wireless, Telecom
              Canada                         IC, A2LA, NIST                           EMC, RF/Wireless, Telecom
               Taiwan                       BSMI, NCC, NIST                            EMC, RF, Telecom, Safety
             Hong Kong                         OFTA, NIST                                RF/Wireless, Telecom
              Australia                        NATA, NIST                              EMC, RF, Telecom, Safety
               Korea                         KCC/RRA, NIST                           EMI, EMS, RF, Telecom, Safety
               Japan                     VCCI, JATE, TELEC, RFT                        EMI, RF/Wireless, Telecom
               Mexico                    NOM, COFETEL, Caniety                      EMC, RF/Wireless, Telecom, Safety
               Europe                           A2LA, NIST                             EMC, RF, Telecom, Safety
                Israel                          MOC, NIST                              EMC, RF, Telecom, Safety


                                    Accreditations for Product Certifications
               Country                      Accreditation Body                                   Scope
                 USA                          FCC TCB, NIST                                 EMC, RF, Telecom
               Canada                          IC FCB, NIST                                 EMC, RF, Telecom
              Singapore                          iDA, NIST                                  EMC, RF, Telecom
                 EU                                 NB                                    EMC & R&TTE Directive
                Japan                         MIC (RCB 208)                                   RF, Telecom
              Hong Kong                       OFTA (US002)                                    RF, Telecom




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                             Test report No.              FCC_IC_RF_SL16041201-HID-019
                                                                             Page                         3 of 33




CONTENTS
1      REPORT REVISION HISTORY .......................................................................................................................................4
2      EXECUTIVE SUMMARY.................................................................................................................................................5
3      CUSTOMER INFORMATION ..........................................................................................................................................5
4      TEST SITE INFORMATION ............................................................................................................................................5
5      MODIFICATION .............................................................................................................................................................5
6      EUT INFORMATION ......................................................................................................................................................6
     6.1    EUT Description ........................................................................................................................................................6
     6.2    Radio Description ......................................................................................................................................................6
     6.3    EUT test modes/configuration Description....................................................................................................................7
     6.4    EUT Photos – External ..............................................................................................................................................8
     6.5    EUT Photos – Internal................................................................................................................................................9
     6.6    EUT Test Setup Photos ........................................................................................................................................... 10
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION ....................................................................... 12
     7.1    Supporting Equipment ............................................................................................................................................. 12
     7.2    Cabling Description ................................................................................................................................................. 12
     7.3    Test Software Description ........................................................................................................................................ 12
8      TEST SUMMARY ......................................................................................................................................................... 13
9      MEASUREMENT UNCERTAINTY ................................................................................................................................. 14
10          MEASUREMENTS, EXAMINATION AND DERIVED RESULTS .................................................................................. 15
     10.1       Antenna Requirement.......................................................................................................................................... 15
     10.2       Conducted Emissions Test Result ........................................................................................................................ 16
     10.3       Radiated Measurements 30MHz to 1GHz .............................................................................................................. 19
     10.4       Radiated Measurements below 30MHz ................................................................................................................. 21
     10.5       Frequency Stability.............................................................................................................................................. 26
     10.6       Occupied bandwidth ............................................................................................................................................ 28
ANNEX A. TEST INSTRUMENT ........................................................................................................................................... 31
ANNEX B. SIEMIC ACCREDITATION ................................................................................................................................... 32




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                          Visit us at: www.siemic.com; Follow us at:


                                                    Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                    Page                4 of 33




1   Report Revision History
               Report No.                           Report Version                Description           Issue Date
FCC_IC_RF_SL16041201-HID-019                               -                       Original             06/10/2016




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                         Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                         Page                5 of 33




2     Executive Summary

The purpose of this test program was to demonstrate compliance of following product
  Company:          HID Global Corporation
  Product:          USB Coupler
  Model:            BCC101

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with the
Stipulated Standard listed on 1st page.



3     Customer information

Applicant Name                         :     HID Global Corporation
Applicant Address                      :     15370 Barranca Parkway, Irvine, CA 92618 USA
Manufacturer Name                      :     HID Global Corporation
Manufacturer Address                   :     10385 Westmoor Drive, Suite 300,Westminster, CO 80021



4     Test site information

Lab performing tests                   :     SIEMIC Laboratories
Lab Address                            :     775 Montague Expressway, Milpitas, CA 95035
FCC Test Site No.                      :     881796
IC Test Site No.                       :     4842D-2
VCCI Test Site No.                     :     A0133



5     Modification

    Index                       Item                                         Description                              Note
      -                           -                                               -                                    -




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                      Page                6 of 33




6     EUT Information

6.1    EUT Description

Product Name                                  :    USB Coupler
Model No.                                     :    BCC101
Trade Name                                    :    HID
Serial No.                                    :    N/A
Input Power                                   :    12V DC
Product Hardware version                      :    N/A
Product Software version                           N/A
Radio Hardware version                             N/A
Radio Software version                             N/A
Test SW Version                                    N/A
Date of EUT received                          :    05/31/2016
Equipment Class/ Category                     :    DXX, DCD
Working Frequencies                           :    125 kHz, 13.56MHz
Port/Connectors                               :    USB


6.2    Radio Description

Specifications for Radio:
              Radio Type                  RFID
         Operating Frequency              125KHz, 13.56MHz
              Modulation                  ASK (125KHz), ASK (13.56MHz)
           Channel Spacing                None
             Antenna Type                 inductor coil type, mounted external to printed circuit board
             Antenna Gain                 1 dBi
        Antenna Connector Type            soldered to printed circuit board

Channel List:
          Type                      Mode                Channel No.             Frequency (MHz)           Available (Y/N)
          RFID                     125KHz                   1                        0.125                      Y
          RFID                    13.56MHz                  1                        13.56                      Y




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                         Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                         Page                7 of 33




6.3    EUT test modes/configuration Description

                  Mode                                                                 Note
                 RF test                      EUT is set to continuously transmit at 13.56MHz and 125kHz


Note: None


                  Test Item                              Operating mode                Tested antenna port   Test frequencies

             Antenna Requirement                                N/A                             -

        Conducted Emissions Voltage                    Continuous Transmit                      -

   Limit in the band of 13.553 – 13.567 MHz            Continuous Transmit                      -

 Limit in the band of 13.410 – 13.553 MHz and
                                                       Continuous Transmit                      -
              13.567 – 13.710 MHz                                                                                125kHz

 Limit in the band of 13.110 – 13.410 MHz and                                                                   13.56MHz
                                                       Continuous Transmit                      -
              13.710 – 14.010 MHz

Limit outside the band of 13.110 – 14.010 MHz          Continuous Transmit                      -

              Frequency Stability                      Continuous Transmit                      -

             Occupied Bandwidth                        Continuous Transmit                      -

Note: EUT uses a PCB trace antenna attached to the PCB board. Only radiated measurements were performed during the test.




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                    Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                    Page                8 of 33




6.4   EUT Photos – External




                      Top View                                                        Bottom View




                     Front View                                                        Rear View




                    Left Side View                                                  Right Side View


       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                    Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                    Page                9 of 33




6.5   EUT Photos – Internal




                   PCBA Top View                                                   PCBA Bottom View




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.    FCC_IC_RF_SL16041201-HID-019
                                                          Page               10 of 33




6.6    EUT Test Setup Photos




          AC Line Conducted Emissions– Front View                               AC Line Conducted Emissions– Rear View




          Radiated Emissions (<1GHz) – Front View                               Radiated Emissions (<1GHz) – Rear View




      Radiated Emissions (<30MHz) – Front View 0 degree                     Radiated Emissions (<30MHz) – Rear View 0 degree



         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                    Test report No.    FCC_IC_RF_SL16041201-HID-019
                                                    Page               11 of 33




Radiated Emissions (<30MHz) – Front View 0 degree                     Radiated Emissions (<30MHz) – Rear View 0 degree




   775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                        Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.        FCC_IC_RF_SL16041201-HID-019
                                                           Page                   12 of 33




7        Supporting Equipment/Software and cabling Description

7.1        Supporting Equipment

Index                Supporting Equipment              Model                 Serial No                    Manu            Note
                         Description
    1                       Laptop                   Thinkpad         L3-BY5447 07/86                      IBM                -


7.2        Cabling Description

                          Connection Start                 Connection Stop                     Length / shielding Info
    Name                                                                                                                 Note
                       From          I/O Port             To           I/O Port              Length (m)      Shielding
    USB                EUT             USB              Laptop           USB                    1M              N/A       -


7.3        Test Software Description

        Test Item                 Software                                                Description
        RF Testing                RealTerm                             Set the EUT to transmit at 125KHz and 13.56MHz




             775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.            FCC_IC_RF_SL16041201-HID-019
                                                                 Page                       13 of 33




8    Test Summary

              Test Item                                   Test standard                           Test Method/Procedure                      Pass / Fail

                                               FCC                15.203                          ANSI C63.10 – 2013                        ☒ Pass
         Antenna Requirement
                                                IC                                       558074 D01 DTS Meas. Guidance v03r02               ☐ N/A
                                               FCC               15.225(a)                                                                  ☒ Pass
    AC Conducted Emissions Voltage                                                                     ANSI C63.10 2013
                                                IC           RSS Gen (7.2.2)                             RSS Gen. 8.8                       ☐ N/A

                Remark                               1.     AC Line tests were performed on the support equipment’s power adapter, laptop.




              Test Item                                   Test standard                           Test Method/Procedure                      Pass / Fail
                                               FCC               15.225(a)            FCC                 ANSI C63.10 2013                  ☒ Pass
Limit in the band of 13.553 – 13.567 MHz                                                                                                    ☐ N/A
                                                IC             RSS210(A2.6)            IC                   RSS Gen 6.13
Limit in the band of 13.410 – 13.553 MHz       FCC               15.225(b)            FCC                 ANSI C63.10 2013                  ☒ Pass
         and 13.567 – 13.710 MHz                IC             RSS210(A2.6)            IC                  RSS Gen 6.13                     ☐ N/A
Limit in the band of 13.110 – 13.410 MHz       FCC               15.225(c)            FCC                 ANSI C63.10 2013                  ☒ Pass
         and 13.710 – 14.010 MHz                IC             RSS210(A2.6)            IC                   RSS Gen 6.13                    ☐ N/A

        Limit outside the band of              FCC           15.225(d), 15.209        FCC                 ANSI C63.10 2013                  ☒ Pass
         13.110 – 14.010 MHz                    IC             RSS210(A2.6)            IC                   RSS Gen 6.13
                                                                                                                                            ☐ N/A
                                                                                                                                            ☐ Pass
      Receiver Spurious Emission                IC                    -                IC                   RSS Gen 7.1
                                                                                                                                            ☒ N/A
                                               FCC               15.225(e)            FCC                          -                        ☒ Pass
          Frequency Stability                                                                                                               ☐ N/A
                                                IC             RSS210(A2.6)            IC                   RSS Gen 6.11
                                               FCC                    -               FCC                          -                        ☒ Pass
          Occupied Bandwidth                                                                                                                ☐ N/A
                                                IC             RSS-210(5.9.1)          IC                    RSS Gen 6.6
                                                     2.     All measurement uncertainties are not taken into consideration for all presented test result.
                                                     3.     The applicant shall ensure frequency stability by showing that an emission is maintained
                Remark                                      within the band of operation under all normal operating conditions as specified in the user’s
                                                            manual.
                                                     4.     Test Method: ANSI C63.10: 2013 / RSS – Gen Issue 4: November 2014.




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                    Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                      Page                14 of 33




9   Measurement Uncertainty

                     Test Item                                      Description                     Uncertainty
                                                      Confidence level of approximately 95%
         AC Conducted Emissions Voltage                (in the case where distributions are              ±3.5dB
                                                       normal), with a coverage factor of 2
      Limit in the band of 13.553 – 13.567 MHz                                                     +5.6dB/-4.5dB

    Limit in the band of 13.410 – 13.553 MHz and
                                                                                                   +5.6dB/-4.5dB
                 13.567 – 13.710 MHz
                                                      Confidence level of approximately 95%
    Limit in the band of 13.110 – 13.410 MHz and       (in the case where distributions are
                                                                                                   +5.6dB/-4.5dB
                 13.710 – 14.010 MHz                   normal), with a coverage factor of 2
                                                        (for EUTs < 0.5m X 0.5m X 0.5m)
              Limit outside the band of
                                                                                                   +5.6dB/-4.5dB
               13.110 – 14.010 MHz
           Radiated Spurious Emissions                                                             +5.6dB/-4.5dB




      775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.      FCC_IC_RF_SL16041201-HID-019
                                                      Page                 15 of 33




10 Measurements, examination and derived results

10.1 Antenna Requirement

Spec            Requirement                                                                                        Applicable
                An intentional radiator shall be designed to ensure that no antenna other than that furnished
                by the responsible party shall be used with the device.

                Antenna requirement must meet at least one of the following:
   §15.203                                                                                                              ☒
                a) Antenna must be permanently attached to the device.
                b) The antenna must use a unique type of connector to attach to the device.
                c) Device must be professionally installed. The installer shall be responsible for ensuring that
                the correct antenna is employed by the device.


                The RFID antenna is integral to the PCB board permanently to the device which meets the requirement (See
   Remark
                Internal Photographs submitted as another Exhibit).

   Result       ☒ PASS             ☐ FAIL




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                                             Test report No.       FCC_IC_RF_SL16041201-HID-019
                                                             Page                  16 of 33




10.2 Conducted Emissions Test Result
                                                         Conducted Emission Limit

                                       Frequency ranges                               Limit (dBuV)
                     Section
                                            (MHz)                          QP                        Average
                                            0.15 ~ 0.5                   66 – 56                     56 – 46
                     Class B
                                             0.5 ~ 5                       56                          46
                     devices
                                              5 ~ 30                       60                          50

Spec                Item        Requirement                                                                               Applicable
                                For an intentional radiator that is designed to be connected to the public utility (AC)
                                power line, the radio frequency voltage that is conducted back onto the AC power line
  § 15.207,                     on any frequency or frequencies, within the band 150 kHz to 30 MHz, shall not exceed
                       a)       the limits set in § 15.207, as measured using a 50 μH/50 ohms line impedance                   ☒
RSS210(A8.1)
                                stabilization network (LISN).
                                AC Line conducted emission within the band 150kHz to 30MHz




  Test Setup




                            -    The EUT and supporting equipment were set up in accordance with the requirements of the standard on
                                 top of a 1.5m x 1m x 0.8m high, non-metallic table, as shown in Annex B.
  Procedure                 -    The power supply for the EUT was fed through a 50/50H EUT LISN, connected to filtered mains.
                            -    The RF OUT of the EUT LISN was connected to the EMI test receiver via a low-loss coaxial cable.
                            -    All other supporting equipment was powered separately from another main supply.
                                                                                              Temperature                  21°C
  Test Date         06/07/2016                             Environmental conditions           Relative Humidity            38 %
                                                                                              Atmospheric Pressure         1025 mbar
   Remark           The EUT was tested at 120VAC, 60Hz.

    Result          ☒ Pass               ☐ Fail

Test Data      ☒ Yes                        ☐ N/A
Test Plot      ☒ Yes                        ☐ N/A

Test was done by Teody Manansala at Conducted Emission test site.

            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                   Visit us at: www.siemic.com; Follow us at:


                                                         Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                         Page                17 of 33




Test specification:                   Conducted Emissions
Mains Power:                          110VAC, 60Hz
Tested by:                            Teody Manansala                                                               ☒ Pass
                                                                                                Result:
                                                                                                                    ☐ Fail
Test Date:                            06/07/2016
Remarks:                              AC Line @ Live




                                                             Fundamental
                                                             frequency




                                             Quasi Peak and Average Measurements

      Frequency         Raw        Cable    Factors     Level      Measurement       Line/     Limit      Margin
                                                                                                                   Pass /Fail
         MHz            dBuV       Loss       dB        dBuV          Type          Neutral    dBuV        dB
           0.16         45.15      10.00      1.69      56.84        Quasi Peak         Live   65.52      -8.68      Pass
         13.56          35.41      10.06      0.59      46.05        Quasi Peak         Live   60.00      -13.95     Pass
           0.24         35.56      10.00      1.12      46.69        Quasi Peak         Live   62.23      -15.54     Pass
           0.33         27.50      10.01      0.85      38.36        Quasi Peak         Live   59.47      -21.11     Pass
           3.23         16.38      10.03      0.55      26.96        Quasi Peak         Live   56.00      -29.04     Pass
           3.14         16.73      10.03      0.55      27.30        Quasi Peak         Live   56.00      -28.70     Pass
         0.16           26.65      10.00      1.69      38.34          Average          Live   55.52      -17.18     Pass
         13.56          35.02      10.06      0.59      45.66          Average          Live   50.00       -4.34     Pass
         0.24           14.56      10.00      1.12      25.68          Average          Live   52.23      -26.55     Pass
         0.33            9.50      10.01      0.85      20.36          Average          Live   49.47      -29.12     Pass
         3.23            0.22      10.03      0.55      10.80          Average          Live   46.00      -35.20     Pass
         3.14            1.80      10.03      0.55      12.38          Average          Live   46.00      -33.62     Pass




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                         Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                         Page                18 of 33




Test specification:                   Conducted Emissions
Mains Power:                          110VAC, 60Hz
Tested by:                            Teody Manansala                                                              ☒ Pass
                                                                                               Result:
                                                                                                                   ☐ Fail
Test Date:                            06/07/2016
Remarks:                              AC Line @ Neutral




                                                              Fundamental
                                                              frequency




                                             Quasi Peak and Average Measurements

      Frequency         Raw        Cable    Factors     Level      Measurement       Line/    Limit      Margin
                                                                                                                  Pass /Fail
         MHz           dBµV        Loss       dB        dBµV          Type          Neutral   dBµV        dB
           0.16         33.42      10.00      1.66      45.08        Quasi Peak     Neutral   65.42      -20.34     Pass
         13.56          35.77      10.06      0.59      46.41        Quasi Peak     Neutral   60.00      -13.59     Pass
           0.25         31.96      10.00      1.06      43.02        Quasi Peak     Neutral   61.73      -18.71     Pass
           1.94         14.66      10.02      0.55      25.24        Quasi Peak     Neutral   56.00      -30.77     Pass
           4.39         15.24      10.03      0.55      25.82        Quasi Peak     Neutral   56.00      -30.18     Pass
           1.84         15.45      10.02      0.55      26.03        Quasi Peak     Neutral   56.00      -29.97     Pass
         0.16           11.53      10.00      1.66      23.20          Average      Neutral   55.42      -32.22     Pass
         13.56          35.28      10.06      0.59      45.93          Average      Neutral   50.00       -4.07     Pass
         0.25           15.00      10.00      1.06      26.06          Average      Neutral   51.73      -25.67     Pass
         1.94           -0.40      10.02      0.55      10.18          Average      Neutral   46.00      -35.83     Pass
         4.39           -0.86      10.03      0.55       9.73          Average      Neutral   46.00      -36.27     Pass
         1.84            2.79      10.02      0.55      13.37          Average      Neutral   46.00      -32.63     Pass




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.       FCC_IC_RF_SL16041201-HID-019
                                                           Page                  19 of 33




10.3 Radiated Measurements 30MHz to 1GHz
Requirement(s):
 Spec                   Requirement                                                                                       Applicable
                                                Operation within the band 13.110–14.010 MHz:
                             (a) The field strength of any emissions within the band 13.553–13.567 MHz shall
                                               not exceed 15,848 microvolts/meter at 30 meters.
                                (b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field
                               strength of any emissions shall not exceed 334 microvolts/meter at 30 meters.
                                 (c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field
                               strength of any emissions shall not exceed 106 microvolts/meter at 30 meters.
  47 CFR §15.225              (d) The field strength of any emissions appearing outside of the 13.110–14.010                    ☒
  RSS-210 (A2.6)                 MHz band shall not exceed the general radiated emission limits in §15.209.

                                      Frequency range (MHz)                      Field Strength (uV/m)
                                              30 – 88                                     100
                                             88 – 216                                     150
                                             216 960                                      200
                                            Above 960                                     500




    Test Setup




                        1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                        2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                  Maximization of the emissions, was carried out by rotating the EUT, changing the antenna
                                  polarization, and adjusting the antenna height in the following manner:
                                  a.         Vertical or horizontal polarisation (whichever gave the higher emission level over a full
     Procedure                               rotation of the EUT) was chosen.
                                  b.         The EUT was then rotated to the direction that gave the maximum emission.
                                  c.         Finally, the antenna height was adjusted to the height that gave the maximum emission.
                        3.        A Quasi-peak measurement was then made for that frequency point.
                        4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                  measured.
                                                                                               Temperature                   20.1°C
     Test Date          05/31/2016                              Environmental conditions       Relative Humidity             36%
                                                                                               Atmospheric Pressure          1026mbar
        Remark          -

        Result          ☒ Pass            ☐ Fail

Test Data      ☒ Yes (See below)             ☐ N/A
Test Plot      ☒ Yes (See below)             ☐ N/A
Test was done by Teody Manansala at 10 meter chamber.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.         FCC_IC_RF_SL16041201-HID-019
                                                        Page                    20 of 33




Test specification:                  Radiated Emissions
Mains Power:                         12VDC
Tested by:                           Teody Manansala                                                                ☒ Pass
                                                                                                    Result:
                                                                                                                    ☐ Fail
Test Date:                           05/31/2016
Remarks:                             125KHz and 13.56MHz Below 1GHz

                                         ƒ=30MHz – 1000MHz plot and 3 meter distance




                                              ƒ=30MHz – 1000MHz Measurements

Frequency       Raw       Cable     AF       Level     Measurement                    Hgt     Azt        Limit    Margin     Pass
                                                                            Pol
   MHz         dBµV/m     Loss      dB      dBµV/m        Type                        cm      Deg       dBµV/m     dB        /Fail
  325.44         67.03     2.74    -25.22    44.55        Quasi Max         H       100.00   30.00        46.02   -1.47      Pass
  352.56         63.29     2.90    -24.75    41.44        Quasi Max         H       100.00   43.00        46.02   -4.58      Pass
  298.38         59.02     2.62    -26.11    35.53        Quasi Max         H       116.00   281.00       46.02   -10.49     Pass
  284.75         63.67     2.59    -26.25    40.00        Quasi Max         H       104.00   273.00       46.02   -6.02      Pass
  338.99         62.21     2.82    -25.12    39.91        Quasi Max         H       100.00   48.00        46.02   -6.11      Pass
  379.68         61.42     3.02    -24.16    40.28        Quasi Max         H       100.00   264.00       46.02   -5.74      Pass




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                         Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                         Page                21 of 33




10.4 Radiated Measurements below 30MHz

Requirement(s):
Spec                   Requirement                                                                                  Applicable
                       Operation within the band 13.110–14.010 MHz
                       (a) The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed
                       15,848 microvolts/meter at 30 meters.
                       (b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of any
 47 CFR §15.225        emissions shall not exceed 334 microvolts/meter at 30 meters.                                     ☒
 RSS-210 (A2.6)        (c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any
                       emissions shall not exceed 106 microvolts/meter at 30 meters.
                       (d) The field strength of any emissions appearing outside of the 13.110–14.010 MHz band
                       shall not exceed the general radiated emission limits in §15.209.




   Test Setup




                       For < 30MHz, Radiated emissions were measured according to ANSI C63.10. The EUT was set to transmit at
                       the highest output power.
    Procedure          The EUT was set 3 meter away from the measuring antenna. The loop antenna was positioned 1 meter above
                       the ground from the center of the loop. The measuring bandwidth was set to 10 kHz.
                       The limit is converted from microvolt/meter to decibel microvolt/meter.
                                                                                           Temperature               22°C
    Test Date          05/31/2016                             Environmental conditions     Relative Humidity         40%
                                                                                           Atmospheric Pressure      1026mbar
       Remark          -

       Result          ☒ Pass            ☐ Fail


Test Data       ☒ Yes (See below)           ☐ N/A

Test Plot       ☒ Yes (See below)          ☐ N/A

Test was done by Teody Manansala at 10 meter chamber.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                         Test report No.            FCC_IC_RF_SL16041201-HID-019
                                                         Page                       22 of 33




Test specification:                   Radiated Spurious Emissions
Mains Power:                          12VDC
Tested by:                            Teody Manansala                                                                   ☒ Pass
                                                                                                        Result:
                                                                                                                        ☐ Fail
Test Date:                            05/31/2016
Remarks:                              125KHz and 13.56MHz Below 30MHz @ 0 degree

                                     ƒ= 100kHz – 30MHz plot, and loop antenna at 0 degree




                                                     Quasi Max Measurement


Frequency       Raw     Cable       AF       Level     Measurement          Pol         Hgt     Azt          Limit    Margin     Pass
   MHz          dBuV    Loss        dB      dBuV/m        Type             (0/90)       cm      Deg         dBuV/m     dB        /Fail

   0.97        40.20     0.21      12.49     52.90      Quasi Max            H        100.00   165.00        67.90    -15.00     Pass
   1.45        39.11     0.24      8.69      48.04      Quasi Max            H        100.00   173.00        64.37    -16.33     Pass
   0.53        36.87     0.18      17.20     54.25      Quasi Max            H        100.00   204.00        73.11    -18.86     Pass
   1.69        34.47     0.26      7.47      42.20      Quasi Max            H        100.00   299.00        63.07    -20.87     Pass
   2.33        34.38     0.30      4.91      39.59      Quasi Max            H        100.00   330.00        69.54    -29.95     Pass
   0.19        33.85     0.17      25.97     59.99      Quasi Max            H        100.00   145.00        102.18   -42.19     Pass




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                         Test report No.            FCC_IC_RF_SL16041201-HID-019
                                                         Page                       23 of 33




Test specification:                   Radiated Spurious Emissions
Mains Power:                          12VDC
Tested by:                            Teody Manansala                                                                  ☒ Pass
                                                                                                        Result:
                                                                                                                       ☐ Fail
Test Date:                            05/31/2016
Remarks:                              125KHz and 13.56MHz Below 30MHz @ 90 degree

                                     ƒ= 100kHz – 30MHz plot, and loop antenna at 90 degree




                                                     Quasi Max Measurement


Frequency       Raw     Cable       AF       Level     Measurement          Pol         Hgt     Azt          Limit   Margin     Pass
   MHz          dBuV    Loss        dB      dBuV/m        Type             (0/90)       cm      Deg         dBuV/m    dB        /Fail

   1.38        34.27     0.24      9.12      43.63      Quasi Max            H        100.00   251.00        64.84   -21.20     Pass
   1.58        34.48     0.25      8.00      42.74      Quasi Max            H        100.00   317.00        63.64   -20.91     Pass
   0.64        33.32     0.19     15.69      49.19      Quasi Max            H        100.00   222.00        71.43   -22.24     Pass
   2.34        34.27     0.30      4.86      39.43      Quasi Max            H        100.00    2.00         69.54   -30.11     Pass
   3.24        36.02     0.31      2.48      38.81      Quasi Max            H        100.00    64.00        69.54   -30.73     Pass
   0.49        36.02     0.17     17.92      54.10      Quasi Max            H        100.00   107.00        93.86   -39.75     Pass




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                Test report No.           FCC_IC_RF_SL16041201-HID-019
                                                Page                      24 of 33




                                           Loop antenna at 0 degree
                                            * RBW 10 kHz
                      * Att 30 dB           * VBW 30 kHz          M1[1]              90.33 dBµV
                        Ref 107.0 dBµV        SWT 40ms                        123.900100000 kHz
                          FCC-15.225-125KHZ-FIELDSTR.LIN
                                Limit Check                PASS
                    1Pk 100 dBµV
                              Line FCC-15.225-125PASS
                    View                         M1
                          90 dBµV


                          80 dBµV


                          70 dBµV


                          60 dBµV


                          50 dBµV


                          40 dBµV


                          30 dBµV

                    Tdf
                          20 dBµV
                    PA

                          10 dBµV

                          CF 125.0 kHz                                           Span 50.0 kHz

                   Date: 1.JUN.2016     01:12:45


            Frequency (kHz)                                                          Amplitude (dBµV)
                124.519                                                                    90.33

                                           Loop antenna at 90 degree
                                            * RBW 10 kHz
                      * Att 30 dB           * VBW 30 kHz          M1[1]              87.94 dBµV
                        Ref 107.0 dBµV        SWT 40ms                        126.049900000 kHz
                          FCC-15.225-125KHZ-FIELDSTR.LIN
                                Limit Check                PASS
                    1Pk 100 dBµV
                              Line FCC-15.225-125PASS
                    View
                                                    M1
                          90 dBµV


                          80 dBµV


                          70 dBµV


                          60 dBµV


                          50 dBµV


                          40 dBµV


                          30 dBµV

                    Tdf
                          20 dBµV
                    PA

                          10 dBµV

                          CF 125.0 kHz                                           Span 50.0 kHz

                   Date: 1.JUN.2016     01:18:45


            Frequency (kHz)                                                          Amplitude (dBµV)
                125.087                                                                    87.94




775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                    Visit us at: www.siemic.com; Follow us at:


                                                Test report No.           FCC_IC_RF_SL16041201-HID-019
                                                Page                      25 of 33




                                           Loop antenna at 0 degree
                                         * RBW 10 kHz
                      * Att 25 dB        * VBW 30 kHz             M1[1]            60.47 dBµV/m
                        Ref 103.0 dBµV/m   SWT 10ms                            13.560000000 MHz
                                Limit
                          100 dBµV/m    Check            PASS
                   1Pk
                   View 90 dBµV/m
                             Line FCC-15.225-13.5
                                                PASS

                          80 dBµV/m


                           70 dBµV/m
                          FCC-15.225-13.56MHz
                                                           M1
                          60 dBµV/m


                          50 dBµV/m


                          40 dBµV/m


                          30 dBµV/m


                    Tdf   20 dBµV/m


                          10 dBµV/m


                          CF 13.56 MHz                                          Span 900.0 kHz

                   Date: 4.JUN.2016      00:33:48


            Frequency (MHz)                                                          Amplitude (dBµV/m)
               13.560450                                                                    69.24

                                           Loop antenna at 90 degree
                                         * RBW 10 kHz
                      * Att 25 dB        * VBW 30 kHz             M1[1]            60.10 dBµV/m
                        Ref 103.0 dBµV/m   SWT 10ms                            13.559550000 MHz
                                Limit
                          100 dBµV/m    Check            PASS
                   1Pk
                   View 90 dBµV/m
                             Line FCC-15.225-13.5
                                                PASS

                          80 dBµV/m


                           70 dBµV/m
                          FCC-15.225-13.56MHz
                                                           M1
                          60 dBµV/m


                          50 dBµV/m


                          40 dBµV/m


                          30 dBµV/m


                    Tdf   20 dBµV/m


                          10 dBµV/m


                          CF 13.56 MHz                                          Span 900.0 kHz

                   Date: 4.JUN.2016      00:41:06


            Frequency (MHz)                                                          Amplitude (dBµV/m)
               13.560450                                                                    68.66




775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                    Visit us at: www.siemic.com; Follow us at:


                                                          Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                          Page                26 of 33




10.5 Frequency Stability

Requirement(s):
Spec                    Requirement                                                                             Applicable
 47 CFR §15.225 e)
                        Limit: ±0.01% of 13.56 MHz = 1356 Hz                                                            ☒
   RSS-210 (A2.6)



                                        EUT                                     Fast Power Meter

    Test Setup
                               Environmental Chamber


                          1.   The EUT was set up inside an environmental chamber.
                          2.   The EUT was placed in the centre of the environmental.

                        Frequency Stability was measured according to 47 CFR §2.1055. Measurement was taken with spectrum
     Procedure          analyzer. The spectrum analyzer bandwidth and span was set to read in hertz. A voltmeter was used to
                        monitor when varying the voltage.
                                                                                         Temperature              20°C
       Test Date        06/03/2016                            Environmental conditions   Relative Humidity        41%
                                                                                         Atmospheric Pressure     1026mbar

       Remark           None

        Result          ☒ Pass             ☐ Fail


Test Data      ☒ Yes (See below)            ☐ N/A

Test Plot      ☐ Yes (See below)           ☒ N/A

Test was done by Teody Manansala at RF test site.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                       Test report No.         FCC_IC_RF_SL16041201-HID-019
                                                       Page                    27 of 33




Test Result for 13.56MHz Radio

Frequency Stability versus Temperature: The Frequency tolerance of the carrier signal shall be maintained within ± 0.01% of the
operating frequency over a temperature variation of -20ºC to +50ºC at normal supply voltage.
Reference Frequency: 13.5600000 MHz at 20°C at 12 VDC

    Temperature               Measured Freq.               Freq. Drift              Freq. Deviation
                                                                                                                    Pass/Fail
         (ºC)                      (MHz)                      (Hz)                   (Limit: 0.01%)
          50                    13.5600000                    0.00                        <0.01                       Pass
          40                    13.5600000                    0.00                        <0.01                       Pass
          30                    13.5600000                    0.00                        <0.01                       Pass
          20                                                   Reference (13.5600000 MHz)
          10                    13.5600735                    73.5                        <0.01                       Pass
          0                     13.5600857                    85.7                        <0.01                       Pass
         -10                    13.5600857                    85.7                        <0.01                       Pass
         -20                    13.5600857                    85.7                        <0.01                       Pass


Frequency Stability versus Input Voltage: The Frequency tolerance of the carrier signal shall be maintained within ± 0.01%, the
frequency of the transmitter was measured at 85% and at 115% of the rated power supply voltage at a 20ºC environmental
temperature.
Carrier Frequency: 13.5600000 MHz at 20°C at 12 VDC
 Measured Voltage
                               Measured Freq.                    Freq. Drift                      Freq. Deviation
 ±15% of nominal                                                                                                         Pass/Fail
                                   (MHz)                            (Hz)                           (Limit: 0.01%)
      (AC)
         13.8                    13.5600000                              0                            <0.01                  Pass
         10.2                    13.5600000                              0                            <0.01                  Pass




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                           Test report No.      FCC_IC_RF_SL16041201-HID-019
                                                           Page                 28 of 33




10.6 Occupied bandwidth
Requirement(s):
Spec                   Requirement                                                                                       Applicable
                       The transmitter shall be operated at its maximum carrier power measured under normal test
                       conditions. The span of the analyzer shall be set to capture all products of the modulation
                       process, including the emission skirts. The resolution bandwidth shall be set to as close to 1%
                       of the selected span as is possible without being below 1%. The video bandwidth shall be set
                       to 3 times the resolution bandwidth. Video averaging is not permitted. Where practical, a
    RSS-Gen                                                                                                                   ☒
                       sampling detector shall be used given that a peak or peak hold may produce a wider
     4.6.1
                       bandwidth than actual. The trace data points are recovered and directly summed in linear
                       terms. The recovered amplitude data points, beginning at the lowest frequency, are placed in a
                       running sum until 0.5% of the total is reached and that frequency recorded. The process is
                       repeated for the highest frequency data points. This frequency is recorded. The span between
                       the two recorded frequencies is the occupied bandwidth.




    Test Setup




                       1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                       2.        To measure conducted, a SMA cable was used to replace the EUT antenna. To measure radiated,
    Procedure
                                 an external antenna was used to detect EUT transmission signal.
                       3.        Measurement of the 99% Occupied Bandwidth of EUT transmission signal and make record.

                                                                                             Temperature                  22°C
    Test Date          06/01/2016                              Environmental conditions      Relative Humidity            39%
                                                                                             Atmospheric Pressure         1025mbar

       Remark          -

       Result          ☒ Pass             ☐ Fail


Test Data       ☐ Yes (See below)           ☒ N/A

Test Plot       ☒ Yes (See below)           ☐ N/A

Test was done by Teody Manansala at 10 meter chamber.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                    Test report No.     FCC_IC_RF_SL16041201-HID-019
                                                    Page                29 of 33




Test results:
                                                        125 kHz




                   Frequency (kHz)                                                 Occupied Bandwidth (KHz)
                       125.00                                                                2.41




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                           Visit us at: www.siemic.com; Follow us at:


                                             Test report No.       FCC_IC_RF_SL16041201-HID-019
                                             Page                  30 of 33




                                                13.56 MHz
                                        * RBW 3 kHz
                   * Att 0 dB           * VBW 10 kHz           M1[1]            - 37.80 dBm
                     Ref -10.0 dBm        SWT 15ms                        13.560000000 MHz
                                                               Oc c Bw     6.986027944 kHz
                1Pk                                            T1[1]            - 53.86 dBm
                     -20 dBm
                View                                                      13.556407186 MHz
                                                               T2[1]            - 52.56 dBm
                     -30 dBm                                              13.563393214 MHz
                                                        M1
                     -40 dBm

                                                     T1    T2
                     -50 dBm


                     -60 dBm


                     -70 dBm


                     -80 dBm


                     -90 dBm


                     -100 dBm



                     CF 13.56 MHz                                             Span 100.0 kHz

               Date: 1.JUN.2016      18:18:24



            Frequency (MHz)                                                   Occupied Bandwidth (KHz)
                 13.56                                                                 6.986




775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                    Visit us at: www.siemic.com; Follow us at:


                                                        Test report No.      FCC_IC_RF_SL16041201-HID-019
                                                        Page                 31 of 33




Annex A. TEST INSTRUMENT

          Instrument                       Model               Serial #          Cal Date    Cal Cycle      Cal Due   In use

    Conducted Emissions
        R & S Receiver                    ESIB 40               100179          06/03/2015    1 Year     06/03/2016
         CHASE LISN                      MN2050B                 1018           08/07/2015    1 Year     08/07/2016
      Radiated Emissions
        R & S Receiver                      ESL6                100178          05/27/2015    1 Year     05/27/2016
        R & S Receiver                    ESIB 40               100179          06/03/2015    1 Year     06/03/2016
   Pre-Amplifier (1-26.5GHz)               8449B             3008A00715         03/04/2016    1 Year     03/04/2017
   Preamplifier (100KHz-7GHz)             LPA-6-30            11140711          02/10/2016    1 Year     02/10/2017
   ETS-Lingren Loop Antenna                 6512              00049120          08/20/2015    1 Year     08/20/2016
 Bi-Log antenna (30MHz~2GHz)                JB1                A030702          08/15/2015    1 Year     08/15/2016
   Horn Antenna (1-26.5GHz)                 3115              10SL0059          08/25/2015    1 Year     08/25/2016
 Tuned Dipole Antenna 30 - 1000
        MHz (4pcs set)                    AD-100                40133           10/02/2015    1 Year     10/02/2016

         3 Meters SAC                        3M                   N/A           08/08/2015    1 Year     08/08/2016
        10 Meters SAC                       10M                   N/A           09/05/2015    1 Year     09/05/2016
  RF Conducted Measurement
       Spectrum Analyzer                  N9010A              10SL0219          10/27/2015    1 Year     10/27/2016
        R & S Receiver                    ESIB 40               100179          06/03/2015    1 Year     06/03/2016

Test Equity Environment Chamber            1007H                61201           07/28/2015    1 Year     07/28/2016

     USB RF Power Sensor                  7002-006            10SL0190          09/22/2015    1 Year     09/22/2016


Note: Equipment is allowed to have a 3 month extension past the calibration due date.



Test Software Version

              Test Item                            Vendor                   Software                        Version
          Radiated Emission                        EMISoft                EMISoft Vasona                     V5.0
         Conducted Emission                        EMISoft                EMISoft Vasona                     V5.0




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.      FCC_IC_RF_SL16041201-HID-019
                                                      Page                 32 of 33




Annex B. SIEMIC Accreditation


        Accreditations         Document                                        Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio & Telecommunications Terminal Equipment:
                                           EN45001 – EN ISO/IEC 17025
EU NB
                                           Electromagnetic Compatibility:
                                           EN45001 – EN ISO/IEC 17025

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
Hong Kong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                      Test report No.       FCC_IC_RF_SL16041201-HID-019
                                                      Page                  33 of 33




                                           Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                           Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                           1 of the Radio Law

                                           EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                           KN22: Test Method for EMI
                                           EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                           KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                    Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                           RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                           80, RRL Notice 2004-68

                                           Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                           attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                           LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                           PLMN08

Taiwan BSMI CAB Recognition                CNS 13438

                                           R-3083: Radiation 3 meter site
Japan VCCI                                 C-3421: Main Ports Conducted Interference Measurement
                                           T-1597: Telecommunication Ports Conducted Interference Measurements

                                           EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                           61000.6.3, AS/NZS 61000.6.4

                                           Radio communications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                           AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                           AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                           Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                           AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                           AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                           AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                 S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                           S043.2




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2017-12-09 09:59:08
Document Modified: 2017-12-09 09:59:08

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC