MPE

FCC ID: JPZ0121

RF Exposure Info

Download: PDF
FCCID_4135765

          § 15.247(i)     Maximum Permissible Exposure


RF Exposure Requirements:           §1.1307(b)(1) and §1.1307(b)(2): Systems operating under the provisions of
                                    this section shall be operated in a manner that ensures that the public is not
                                    exposed to radio frequency energy levels in excess of the Commission’s
                                    guidelines.

RF Radiation Exposure Limit:        §1.1310: As specified in this section, the Maximum Permissible Exposure
                                    (MPE) Limit shall be used to evaluate the environmental impact of human
                                    exposure to radiofrequency (RF) radiation as specified in Sec. 1.1307(b), except
                                    in the case of portable devices which shall be evaluated according to the
                                    provisions of Sec. 2.1093 of this chapter.

                 MPE Limit: EUT’s operating frequencies @ 2400-2483.5 MHz; Limit for Uncontrolled
                 exposure: 1 mW/cm2 or 10 W/m2

                 Equation from page 18 of OET 65, Edition 97-01

                          S = PG / 4R2       or     R = √(PG / 4S)

                 where, S = Power Density (mW/cm2)
                        P = Power Input to antenna (mW)
                        G = Antenna Gain (numeric value)
                        R = Distance (cm)

Test Results:

                                                            FCC
                                                                 Pwr.
Frequency Con. Pwr. Con. Pwr. Ant. Gain Ant. Gain                        Limit                     Distance
                                                               Density         2        Margin                   Result
  (MHz)    (dBm)     (mW)       (dBi)   numeric                        (mW/cm   )                    (cm)
                                                              (mW/cm2)
   2405         11.08      12.823         2         1.585      0.00404     1            0.99596        20         Pass


The safe distance where Power Density is less than the MPE Limit listed above was found to be 20 cm.



Document Created: 2018-12-21 11:25:21