Report part 1

FCC ID: JPZ0043

Test Report

Download: PDF
FCCID_763281

                           TEST REPORT NO. R—2965P

 ELECTROMAGNETIC EMISSIONS EVALUATION TESTS

               PER FCC PART 15, SUBPARTS B AND C

                                           FOR THE

                             LUTRON ELECTRONICS

                     MAESTRO WIRELESS (390 MHz)




                                  21 FEBRUARY 2007




PREPARED FOR:                 Lutron Electronics
                               7200 Suter Road
                              Coopersburg, PA 18036



                           Retlif Testing Laboratories
                           3131 Detwiler Road
                          Harleysville, PA 19438
   The results described in this report relate only to the item(s) tested. This document shall not be
   reproduced except infull without written permissionfrom Retlif Testing Laboratories.


                      TEST REPORT NO. R—2965P
                ELECTROMAGNETIC EMISSION EVALUATION
                    FCC PART 15, SUBPART B AND C
                              FOR THE
                        LUTRON ELECTRONICS
                     MODEL #: MAESTRO WIRELESS
                         21 FEBRUARY, 2007




PREPARED FOR:                                Lutron Electronics
                                             7200 Suter Road
                                             Coopersburg, PA 18036



SUBMITTED BY:                                Retlif Testing Laboratories
                                             3131 Detwiler Road
                                             Harleysville, PA 19438
                                             A wholly owned subsidiary of



PREPARED BY:                                 % \W
                                             John Kavalusky         U
                                             EMC Test Technician
                                             Retlif Testing Laboratories



REVIEWED BY:

                                                        échnician       ;
                                             Retlif Testing Laboratories




                                 r.            Retlif Testing Laboratories

                                     I   Test Report No. R—2965P


                              TABLE OF CONTENTS



SECTION   TITLE

          Table of Contents
          List of Figures
          Administrative Data
          Summary of Test Results

 1.0      INTRODUCTION
 2.0      DESCRIPTION OF THE EQUIPMENT UNDER TEST(EUT)
 3.0      TEST INSTRUMENTATION
 4.0      TEST RESULTS
 4.1      Conducted Emissions Test Results
 4.2      Radiated Emissions Test Results (AM Mode)
 4.3      Bandwidth Measurements (AM Mode)
 5.0      CONCLUSIONS




                                      r.              Retlif Testing Laboratories

                                           I    Test Report No. R—2965P


                                           LIST OF FIGURES


FIGURE             TITLE

FIGURE             Conducted   Emissions Test   Setup Diagram
         B G N —




FIGURE             Conducted   Emissions Test   Setup Photographs
FIGURE             Conducted   Emissions Test   Results Phase Line
FIGURE             Conducted   Emissions Test   Results Neutral Line

FIGURE          Duty Cycle Correction Factor
FIGURE          Radiated Emissions Test Setup Diagram
FIGURE     7/8  Radiated Emissions Test Setup Photographs of Rx and Tx
FIGURE     9/10 Radiated Emissions Test Results Data, (AM) Rx Mode, 390MHz
FOGIRE     11   Radiated Emissions Test Results Graph, (AM) Rx Mode, 390MHz
FIGURE     1213 Radiated Emissions Test Results Data, (AM) Tx Mode, 390MHz
FIGURE     14   Radiated Emissions Test Results Graph, (AM) Tx Mode, 390MHz
FIGURE 15          Intentional Radiator Test Results Data, (AM) Tx Mode, 390MHz Position 1
FIGURE 16          Intentional Radiator Test Results Data, (AM) Tx Mode, 390MHz Position 2
FIGURE 17          Intentional Radiator Test Results Data, (AM) Tx Mode, 390MHz Position 3

FIGURE    18       Bandwidth Test Results Data, (AM) Tx Mode, 390MHz
FIGURE    19       Bandwidth Test Results Waveform, (AM) Tx Mode, 390MHz
FIGURE    20       Bandwidth Test Results Waveform, (AM) 390MHz
FIGURE    21       Bandwidth Test Results Waveform, (AM) Tx Mode, 390MHz




                                                      r.               Retlif Testing Laboratories
                                                           I      Test Report No. R—2965P


                               ADMINISTRATIVE DATA


TEST PERFORMED:

Measurements of Radiated RF and Conducted Emissions.

PURPOSE OF TEST:

To evaluate the ElectroMagnetic Emissions (EMC) characteristics of the Equipment Under
Test (EUT) with respect to Subpart B and C of Part 15 of the Federal Communications
Commission (FCC) rules for intentional and unintentional radiators.

EQUIPMENT UNDER TEST:

Model Number: MAESTRO WIRELESS (390MHZ)
Serial Number: FCC ID: JPZ0042 (Transmitter)
                       JPZ0043 (Receiver)


CONTRACT:

Purchase Order Number: 77150

TEST PERIOD:

07 thru 12 February, 2007

TEST FACILITY:

Retlif Testing Laboratories, EMC Test Laboratory, located at:    3131   Detwiler Road,
Harleysville, Pennsylvania 19438.

TEST PERSONNEL AND COORDINATORS:                                        *

Retlif Testing Laboratories                            Lutron Electronics

John Kavalusky                                         Matt Cardoni




                                          r.           Retlif Testing Laboratories

                                               l    Test Report No. R—2965P
                                  —iii—


                                           SUMMARY OF TEST RESULTS


The Model #: MAESTRO WIRELESS (390MHZ), configured as described herein, COMPLIES
WITH THE REQUIREMENTS SET FORTH IN SUBPART B AND C OF PART 15 OF THE
FEDERAL COMMUNICATIONS COMMISSION (FCC) RULES FOR INTENTIONAL AND
UNINTENTIONAL RADIATORS.




   The test results contained in this report represent emission and/or immunity characteristics of only the product(s) (model and
   serial no.) tested. Retlif Testing Laboratories makes no claim that identical test results will be obtained for future tests of
   the same modcl/equipment or that the test results contained herein could be duplicated after the tested product leaves the
   possession of the Retlif Testing Laboratories.




                                                                   r.                   Retlif Testing Laboratories

                                                                          I        Test Report No. R—2965P


1.0 INTRODUCTION


This document is a report to determine the EMC characteristics of the Model #: MAESTRO
WIRELESS (390MHZ). Presented by Lutron Electronics of Coopersburg, Pennsylvania.

The purpose of the testing was to evaluate the EMC characteristics of the test sample with
respect to Subpart B and C of Part 15 of the FCC Rules for intentional and unintentional
radiators.

All test procedures used meet the requirements of the American National Standards Institute
Procedure C63.4: 2003: "Methods of Measurement of Radio—Noise Emissions from Low—
Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz".




                                             r.           Retlif Testing Laboratories

                                                 I     Test Report No. R—2965P


2.0 DESCRIPTION OF THE EQUIPMENT UNDER TEST (EUT)




The Model# Maestro Wireless, manufactured by Lutron Electronics of Coopersburg Pennsylvania
is a wireless transmitter and contains a separate receiver. It operates at a frequency of 390MHz.




Hereinafter, the Model # Maestro Wireless, will be referred to as the EUT (Equipment Under
Test).




                          Transmitter                                 Receiver




                                                 r.              Retlif Testing Laboratories

                                                      I      Test Report No. R—2965P


3.0 INSTRUMENTATION

mst                                                                                 ca.
                                                                                    DuE.
INY
#      DESCRIPTION              MANUFACTURER      MODEL               SERIAL        DATE
712    20ft Cable RG—223        PASTERNACK       BNC TO BNC           NA            11/29/2007

716    35ft Cable 1318          PASTERNACK       BNC TO BNC           N/A           11728/2007

8013   ANTENNA                  TENSOR           4108                 204            671112007

8014   ANTENNA                  AMP.RES.ASSOC.   AT1000               4094—025       6/14/2007

8071   SPEC. ANALY.             H.P.             8566B                3638A08767    11/21/2007

8072   SPEC. A.DISPLY           H.P              85662B               3701A22258    11/21/2007

8073   COMPUTER                 H.P. SYSTEM      9000 300 SERIES      NSN / CART      51112007

8074   TRANSFORMER              G.E.             9T51B33G3            NSN             5/1/2007

8076   SPEC. ANALY.             H.P.             8568B                2841404457     5126/2007

8077   SPEC. A.DISPLY           H.P              85662A               2848A¥17406    5/26/2007

8080   RECEIVER                 R&S              ESVP                 861744/015    12/2212007

8300   —TURNTABLE               EMCO             2065—1.21            0001—2156       5/5/2007

8300   CONTROLLER               EMCO             2090                 0001—1489       515/2007

8300   MINI MAST                EMCO             2075—2               0002—2278       51512007

8317   Pre—Amplifoer            AGILENT          84498                3008A02311    11/21/2007




IF CAL DUE DATE = BLANK FIELD
                                                        .®     Retlif Testing Laboratories
Calibration is not required.
                                                        I    Test Report No. R—2965P


4.0 TEST RESULTS


4.1 Conducted Power Line Measurements, §15.107 Test Results


Conducted power line measurements were recorded for the EUT.


The EUT was placed on a table 8O0cm above a horizontal ground plane in a shield room. The
rear of the EUT was positioned at the edge of a 1m x 1.5m tabletop that was 40cm from the
vertical ground plane. The EUT was positioned 80cm from all metal objects and LISNs. The
filtered power (115Vac, 60Hz) was fed through 50uh LISNs to the EUT. A spectrum analyzer
was used to scan the frequency range of .150—30MHz (as required) for each line.

The test setup diagram is shown in Figure 1 and the photographs are shown in Figure 2.


The EUT was tested while operated at the transmit frequency of 390MHz.


The results of the line—go—ground radio noise voltage measurements are shown in Figures 3
and 4 (Graphs) tested with no load.

Note: Customer claims that they are exempt from testing with the load on (Dimmer On) by the
rule found in part 15.103(d). This states that digital devices in an appliance (dimmers are
appliances) are exempt from testing, therefore Conducted Emissions testing was performed
with the EUT receiving power. No load = Dimmer off and receiver receiving power.

THE LEVELS ARE BELOW THE APPLICABLE LIMITS OF AS SPECIFIED BY FCC IN
§15.107.




                                              r.            Retlif Testing Laboratories

                                                  I     Test Report No. R—2965P


                        r   _   _ Horizontal Ground Plane
Vertical Ground Plane




                                          To Measuring
                                          Receiver




           Conducted Emissions Test Setup Diagram (Top View)
                                        Figure 1

                                                     ®
                                                  @         Retlif Testing Laboratories

                                    —5.                  Test Report No. R—2965P