PCE test report

FCC ID: JOYYAKF-1

Test Report

Download: PDF
FCCID_1991518



                                                                          Page 2 of 27




Table of contents


                                                                                                                                                              Page
1. Summary of Test .................................................................................................................4
   1.1 Purpose of test ....................................................................................................................................... 4
   1.2 Standards ............................................................................................................................................... 4
   1.3 List of applied test to the EUT .............................................................................................................. 4
   1.4 Modification to the EUT by laboratory................................................................................................. 4
2. Equipment Under Test ........................................................................................................5
   2.1 General Description of equipment ....................................................................................................... 5
   2.2 EUT information ..................................................................................................................................... 5
   2.3 Variation of the family model(s)............................................................................................................ 6
   2.4 Description of Test mode ...................................................................................................................... 6
3. Configuration of equipment ...............................................................................................7
   3.1 Equipment(s) used................................................................................................................................. 7
   3.2 System configuration ............................................................................................................................ 7
4. Conducted Output Power ...................................................................................................8
   4.1 Measurement procedure ....................................................................................................................... 8
   4.2 Measurement result ............................................................................................................................... 8
5. Equivalent Isotropic Radiated Power ................................................................................9
   5.1 Measurement procedure ....................................................................................................................... 9
   5.2 Calculation method................................................................................................................................ 9
   5.3 Limit......................................................................................................................................................... 9
   5.4 Test data................................................................................................................................................ 10
6. Peak to Average Ratio....................................................................................................... 11
   6.1 Measurement procedure ......................................................................................................................11
   6.2 Limit........................................................................................................................................................11
   6.3 Measurement result ..............................................................................................................................11
   6.4 Trace data ............................................................................................................................................. 12
7. Occupied Bandwidth.........................................................................................................13
   7.1 Measurement procedure ..................................................................................................................... 13
   7.2 Limit....................................................................................................................................................... 13
   7.3 Measurement result ............................................................................................................................. 13
   7.4 Trace data ............................................................................................................................................. 14
8. Band Edge Spurious and Harmonic at Antenna Terminals ...........................................15
   8.1 Measurement procedure ..................................................................................................................... 15
   8.2 Limit....................................................................................................................................................... 15
   8.3 Measurement result ............................................................................................................................. 15
   8.4 Trace data ............................................................................................................................................. 16
9. Radiated Emissions and Harmonic Emissions...............................................................20
   9.1 Measurement procedure ..................................................................................................................... 20
   9.2 Calculation method.............................................................................................................................. 20
   9.3 Limit....................................................................................................................................................... 20
   9.4 Test data................................................................................................................................................ 21
10. Frequency Stability .........................................................................................................22
   10.1 Measurement procedure ................................................................................................................... 22

TÜV SÜD Zacta Ltd.                                                                                                                          Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                                                          FCC ID: JOYYAKF-1


                                                                         Page 3 of 27




   10.2 Limit..................................................................................................................................................... 22
   10.3 Measurement result ........................................................................................................................... 23
11. Antenna requirement.......................................................................................................24
12. Uncertainty of measurement ..........................................................................................25
13. Laboratory description ...................................................................................................26
Appendix A. Test equipment ................................................................................................27




TÜV SÜD Zacta Ltd.                                                                                                                        Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                                                        FCC ID: JOYYAKF-1


                                                  Page 4 of 27




1. Summary of Test
1.1 Purpose of test

   It is the original test in order to verify conformance to FCC Part 24 Subpart E.


1.2 Standards

   CFR47 FCC Part 24 Subpart E


 1.2.1 Test Methods

   ANSI/TIA/EIA-603-C-2004


 1.2.2 Deviation from standards

    None


1.3 List of applied test to the EUT

              Test items
                                                  Test items                      Condition              Result
               Section
2.1046                           Conducted Output Power                           Conducted               PASS
                                 Effective Radiated Power
24.232(c)                                                                             Radiated            PASS
                                 Equivalent Isotropic Radiated Power
24.232(d)                        Peak to Average Ratio                            Conducted               PASS
24.238(a)
                                 Occupied Bandwidth                               Conducted               PASS
2.1049
24.238(a)                        Band Edge Spurious and Harmonic at
                                                                                  Conducted               PASS
2.1051                           Antenna Terminal
24.238(a)                        Radiated emissions and
                                                                                      Radiated            PASS
2.1053                           Harmonic Emissions
24.235
                                 Frequency Stability                              Conducted               PASS
2.1055


 1.3.1 Test set up

    Table-Top


1.4 Modification to the EUT by laboratory

    None




TÜV SÜD Zacta Ltd.                                                                               Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                               FCC ID: JOYYAKF-1


                                                    Page 5 of 27




2. Equipment Under Test
2.1 General Description of equipment

  EUT is the Mobile Phone.


2.2 EUT information

  Applicant                  :   KYOCERA Corporation
                                 Yokohama Office 2-1-1 Kagahara, Tsuzuki-ku Yokohama-shi, Kanagawa,
                                 Japan
                                 Phone: +81-45-943-6253 Fax: +81-45-943-6314
  Equipment under test       :   Mobile Phone

  Trade name                 :   Kyocera

  Model number               :   YAKF-1

  Serial number              :   N/A

  EUT condition              :   Pre-Production

  Max. frequency             :   1.5GHz

  Power ratings              :   Battery: DC 3.8V

  Size                       :   (W) 134 × (D) 66 × (H) 10.9 mm

  Environment                :   Indoor and Outdoor use

  Terminal limitation        :   -20˚C to 60˚C

  RF Specification
  <GSM>
  Equipment type             :   Transceiver

  Frequency of               :   Up Link: 1850.2-1909.8MHz
  Operation                      Down Link: 1930.2-1989.8MHz
  Modulation type            :   GMSK

  Emission designator        :   246KGXW

  Output power               :   0.98W EIRP (29.9dBm)

  Antenna type               :   Internal antenna

  Antenna gain               :   0dBi




TÜV SÜD Zacta Ltd.                                                                      Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                      FCC ID: JOYYAKF-1


                                               Page 6 of 27




2.3 Variation of the family model(s)

   Not applicable


2.4 Description of Test mode

 The EUT had been tested under operating condition.
 There are three channels have been tested as following:

                      Band                       Channel                        Frequency
                                                   512                          1850.2MHz
                  GSM1900                          661                          1880.0MHz
                                                   810                          1909.8MHz

 The field strength of spurious emissions was measured at each position of all three axis X, Y and Z to
 compare the level, and the maximum noise.
 The worst emission was found in X axis and the worst case recorded.




TÜV SÜD Zacta Ltd.                                                                    Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                    FCC ID: JOYYAKF-1


                                                             Page 7 of 27




3. Configuration of equipment
3.1 Equipment(s) used

No.          Equipment               Company             Model No.             Serial No.           FCC ID / DoC           Comment
 1        Mobile Phone              KYOCERA             YAKF-1               N/A                   JOYYAKF-1              EUT


3.2 System configuration


     1. Mobile Phone
        (EUT)




Note1: Numbers assigned to equipment or cables on this diagram correspond to the list in “3.1 Equipment(s) used”.




TÜV SÜD Zacta Ltd.                                                                                                  Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                                  FCC ID: JOYYAKF-1


                                                             Page 8 of 27




4. Conducted Output Power
4.1 Measurement procedure
 [FCC 2.1046]

  The conducted output power was measured with a wireless communication tester connected to the antenna
  terminal. The wireless communication tester parameters were set to produce the maximum power from the
  EUT.


  - Test configuration



                                                                                                        Wireless
                       EUT                                                                              Communication
                                                 Coaxial cable
                                                                                                        Tester




4.2 Measurement result

Date                         :   May 8, 2013                            Test personnel     :
Temperature                  :   22.0 [˚C]
Humidity                     :   46.0 [%]                               Tested by          :
Test place                   :   Shielded room                                                    Chiaki Kanno


                                                                            Test Result (dBm)

                                    Frequency                GPRS             GPRS             GPRS       GPRS
     Band             Channel
                                      (MHz)      GSM         1 TX              2 TX             3 TX       4 TX
                                                                 Slot          Slot             Slot       Slot

                         512         1850.2      29.24       29.16             26.07           24.46       23.08
      PCS                661         1880.0      29.39       29.31             26.14           24.51       23.24
                         810         1909.8      29.46       29.11             26.00           24.29       22.97




TÜV SÜD Zacta Ltd.                                                                                            Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                            FCC ID: JOYYAKF-1


                                                   Page 9 of 27




5. Equivalent Isotropic Radiated Power

5.1 Measurement procedure
 [FCC 24.232(c)]

<Step 1>
 The EUT and support equipment are placed on a 1 meter x 1.5 meter surface, 0.8 meter height FRP table.
 Radiated emission measurements are performed at 3 meter distance with the broadband antenna (double
 ridged guide antenna). The antenna is positioned both the horizontal and vertical planes of polarization and
 height is varied 1 to 4 meters and stopped at height producing the maximum emission.
 The bandwidth of the spectrum analyzer is set to 1MHz. The turntable is rotated by 360 degrees and
 stopped at azimuth of producing the maximum emission.

<Step 2>
 The substitution antenna is replaced by the transmitter antenna (EUT).
 The frequency of the signal generator is adjusted to the measurement frequency.
 Level of the signal generator is adjusted to the level that is obtained from step 1, and record the emission
 level of signal generator.


  - Test configuration




5.2 Calculation method

Result (EIRP) = S.G Reading – Cable loss + Antenna Gain
Margin = Limit – Result (EIRP)



5.3 Limit

 2 W (33dBm)




TÜV SÜD Zacta Ltd.                                                                         Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                         FCC ID: JOYYAKF-1


                                                       Page 10 of 27




5.4 Test data

Date                         :   May 17, 2013                     Test personnel      :
Temperature                  :   23.0 [˚C]
Humidity                     :   58.0 [%]                         Tested by           :
Test place                   :   3m Semi-anechoic chamber                                  Chiaki kanno


                                   S.A      S.G      Cable
             Frequency                                                 Ant.Gain   Result      Limit            Margin
   H/V                           Reading   Reading    loss
                [MHz]            [dBm]     [dBm]      [dB]              [dBi]     [dBm]       [dBm]              [dB]
    H           1850.2            18.4      23.2      1.1                5.9       28.0       33.0                  5.0
    V           1880.0            18.4      25.0      1.1                6.0       29.9       33.0                  3.1
    V           1909.8            18.8      24.9      1.1                6.1       29.9       33.0                  3.1




TÜV SÜD Zacta Ltd.                                                                                        Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                        FCC ID: JOYYAKF-1


                                                           Page 11 of 27




6. Peak to Average Ratio
6.1 Measurement procedure
 [FCC 24.232(d)]

  The peak to average ratio was measured with a spectrum analyzer connected to the antenna terminal.

  The spectrum analyzer is set to;
   - RBW=1MHz, VBW=3MHz, Span=5MHz, Sweep=auto, Detector=Peak/average, Trace mode=Max hold


  - Test configuration


                                                                       Power splitter
       Spectrum                                                                                              Wireless
       Analyzer                        Attenuator                                                            Communication
                                                       Coaxial cable                     Coaxial cable
                                                                                                             Tester



                                                                           EUT



6.2 Limit

  13dB or less


6.3 Measurement result

Date                         :    May 5, 2013                          Test personnel          :
Temperature                  :    22.0 [˚C]
Humidity                     :    46.0 [%]                             Tested by               :
Test place                   :    Shielded room                                                    Chiaki Kanno



                                             Frequency                 Peak to Average Power Ratio                      Limit
     Mode                    Channel
                                               [MHz]                               [dB]                                  [dB]
  GSM1900                        661            1880                                    0.01                              13




TÜV SÜD Zacta Ltd.                                                                                            Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                            FCC ID: JOYYAKF-1


                                Page 12 of 27




6.4 Trace data
 [GSM 1900]

                 Channel: 661




TÜV SÜD Zacta Ltd.                              Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                              FCC ID: JOYYAKF-1


                                                     Page 13 of 27




7. Occupied Bandwidth
7.1 Measurement procedure
 [FCC 24.238(a), 2.1049]

  The Occupied bandwidth was measured with a spectrum analyzer connected to the antenna terminal.

  The spectrum analyzer is set to;
   - RBW=3kHz, VBW=9.1kHz, Span=1MHz, Sweep=auto, Detector=Peak, Trace mode=Max hold


  - Test configuration


                                                                 Power splitter
       Spectrum                                                                                           Wireless
       Analyzer                     Attenuator                                                            Communication
                                                 Coaxial cable                       Coaxial cable
                                                                                                          Tester



                                                                     EUT




7.2 Limit

  None


7.3 Measurement result

Date                         :   May 8, 2013                     Test personnel          :
Temperature                  :   22.0 [˚C]
Humidity                     :   46.0 [%]                        Tested by               :
Test place                   :   Shielded room                                                  Chiaki Kanno



                                                 Frequency                        Test Result
               Band                   Channel
                                                    (MHz)                           (kHz)

                                        512        1850.2                          245.5945
            GSM1900                     661        1880.0                          243.7157
                                        810        1909.8                          244.1262




TÜV SÜD Zacta Ltd.                                                                                         Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                         FCC ID: JOYYAKF-1


                                Page 14 of 27




7.4 Trace data
 [GSM 1900]
           Channel: 512




                 Channel: 661




                 Channel: 810




TÜV SÜD Zacta Ltd.                              Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                              FCC ID: JOYYAKF-1


                                                        Page 15 of 27




8. Band Edge Spurious and Harmonic at Antenna Terminals
8.1 Measurement procedure
 [FCC 24.238(a), 2.1051]

  The band edge spurious and harmonic was measured with a spectrum analyzer connected to the antenna
  terminal.

  The spectrum analyzer is set to;
  <Band Edge>
   - RBW=3kHz, VBW=9.1kHz, Span=1MHz, Sweep=auto, Detector=Peak, Trace mode=Max hold
  <Spurious Emissions>
   - RBW=1MHz, VBW=3MHz, Span=Arbitrary setting, Sweep=auto, Detector=Peak, Trace mode=Max hold


  - Test configuration


                                                                    Power splitter
       Spectrum                                                                                                Wireless
       Analyzer                     Attenuator                                                                 Communication
                                                    Coaxial cable                    Coaxial cable
                                                                                                               Tester



                                                                        EUT



8.2 Limit

 -13dBm or less


8.3 Measurement result

Date                         :   May 8, 2013                        Test personnel       :
Temperature                  :   22.0 [˚C]
Humidity                     :   46.0 [%]                           Tested by            :
Test place                   :   Shielded room                                                 Chiaki Kanno


                                                 Frequency                 Limit
        Band                     Channel                                                             Results                Results
                                                   [MHz]                   [dB]
                                   512             1850.2                   -13              See the trace data              PASS
   GSM 1900                        661             1880.0                   -13              See the trace data              PASS
                                   810             1909.8                   -13              See the trace data              PASS




TÜV SÜD Zacta Ltd.                                                                                              Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                              FCC ID: JOYYAKF-1


                                Page 16 of 27




8.4 Trace data
 [GSM 1900]
 (Band Edge)
           Channel: 512




                 Channel: 810




TÜV SÜD Zacta Ltd.                              Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                              FCC ID: JOYYAKF-1


                             Page 17 of 27




 (Spurious Emissions)
Channel: 512
30MHz-5GHz                           5GHz-10GHz




10GHz-15GHz                          15GHz-20GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                 FCC ID: JOYYAKF-1


                             Page 18 of 27




Channel: 661
30MHz-5GHz                           5GHz-10GHz




10GHz-15GHz                          15GHz-20GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                 FCC ID: JOYYAKF-1


                             Page 19 of 27




Channel: 810
30MHz-5GHz                           5GHz-10GHz




10GHz-15GHz                          15GHz-20GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                 FCC ID: JOYYAKF-1


                                                    Page 20 of 27




9. Radiated Emissions and Harmonic Emissions

9.1 Measurement procedure
 [FCC 24.238(a), 2.1053]

<Step 1>
 The EUT and support equipment are placed on a 1 meter x 1.5 meter surface, 0.8 meter height FRP table.
 Radiated emission measurements are performed at 3 meter distance with the broadband antenna (TRILOG
 antenna and double ridged guide antenna). The antenna is positioned both the horizontal and vertical planes
 of polarization and height is varied 1 to 4 meters and stopped at height producing the maximum emission.
 The bandwidth of the spectrum analyzer is set to 1MHz. The turntable is rotated by 360 degrees and
 stopped at azimuth of producing the maximum emission. The frequency is investigated up to 20GHz.

<Step 2>
 The substitution antenna is replaced by the transmitter antenna (EUT).
 The frequency of the signal generator is adjusted to the measurement frequency.
 Level of the signal generator is adjusted to the level that is obtained from step 1, and record the emission
 level of signal generator.


  - Test configuration




9.2 Calculation method

 Result = S.G Reading – Cable loss + Antenna Gain
 Margin = Limit – Result (EIRP)



9.3 Limit

 -13dBm or less




TÜV SÜD Zacta Ltd.                                                                         Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                         FCC ID: JOYYAKF-1


                                                       Page 21 of 27




9.4 Test data

Date                         :   May 17, 2013                     Test personnel      :
Temperature                  :   23.0 [˚C]
Humidity                     :   58.0 [%]                         Tested by           :
Test place                   :   3m Semi-anechoic chamber                                  Chiaki Kanno


[GSM 1900]
(Channel: 512)
                                   S.A      S.G      Cable
             Frequency                                                 Ant.Gain   Result      Limit        Margin
   H/V                           Reading   Reading    loss
                [MHz]            [dBm]     [dBm]      [dB]              [dBi]     [dBm]      [dBm]           [dB]
    H              3700.4         -49.7     -43.3     1.6                7.2      -37.7       -13.0             24.7
    V              3700.4         -50.3     -42.2     1.6                7.2      -36.6       -13.0             23.6
    H              5550.0         -54.4     -43.6     1.9                8.8      -36.8       -13.0             23.8
    V              5550.0         -53.9     -44.3     1.9                8.8      -37.5       -13.0             24.5

(Channel: 661)
                                   S.A      S.G      Cable
             Frequency                                                 Ant.Gain   Result      Limit        Margin
   H/V                           Reading   Reading    loss
                [MHz]            [dBm]     [dBm]      [dB]              [dBi]     [dBm]      [dBm]           [dB]
    H              3760.2         -52.8     -46.1     1.6                7.1      -40.6       -13.0             27.6
    V              3760.0         -50.1     -41.2     1.6                7.1      -35.7       -13.0             22.7
    H              5640.0         -57.0     -47.3     2.0                9.1      -40.2       -13.0             27.2
    V              5640.0         -54.2     -44.1     2.0                9.1      -37.0       -13.0             24.0

(Channel: 810)
                                   S.A      S.G      Cable
             Frequency                                                 Ant.Gain   Result      Limit        Margin
   H/V                           Reading   Reading    loss
                [MHz]            [dBm]     [dBm]      [dB]              [dBi]     [dBm]      [dBm]           [dB]
    H              3819.4         -50.6     -43.3     1.6                7.0      -37.9       -13.0             24.9
    V              3819.7         -49.1     -40.1     1.6                7.0      -34.7       -13.0             21.7
    H              5729.0         -52.6     -41.0     2.0                9.4      -33.6       -13.0             20.6
    V              5729.0         -53.4     -43.1     2.0                9.4      -35.7       -13.0             22.7


    Note: No emission were detected in frequency range 30MHz to 1000MHz at the 3 meters distance.




TÜV SÜD Zacta Ltd.                                                                                    Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                    FCC ID: JOYYAKF-1


                                              Page 22 of 27




10. Frequency Stability
10.1 Measurement procedure
 [FCC 24.235, 2.1055]

 The EUT was placed of an inside of an constant temperature chamber as the temperature in the chamber
 was varied between -30˚C and +50˚C. The temperature was incremented by 10˚C intervals and the unit was
 allowed to stabilize at each measurement. The frequency drift was measured with the normal Temperature
 and voltage tolerance and it is presented as the ppm unit.


  - Test configuration


                                                          Power splitter
       Spectrum                                                                            Wireless
       Analyzer              Attenuator                                                    Communication
                                          Coaxial cable                    Coaxial cable
                                                                                           Tester



                                                              EUT




                                               Constant Temperature Chamber




10.2 Limit

  ±2.5ppm




TÜV SÜD Zacta Ltd.                                                                          Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                          FCC ID: JOYYAKF-1


                                                             Page 23 of 27




10.3 Measurement result

Date                         :    May 9, 2013                           Test personnel
Temperature                  :    25.0 [˚C]
Humidity                     :    48.0 [%]                              Tested by             :
Test place                   :    Shielded room                                                   Chiaki Kanno


[GSM 1900]
(Channel: 661)
                                                  Limit: ±0.00025% = ±2.5ppm
                                                                                    Frequency
   Power Supply              Temperature    Measurements Frequency                                       Limit
                                                                                    Tolerance                               Result
           [V]                     [ºC]               [Hz]                           [ppm]              [ppm]
                                 25(Ref.)         1,879,999,974                       0.000              ±2.5               PASS
                                   50             1,879,999,972                      -0.001              ±2.5               PASS
                                   40             1,879,999,971                      -0.002              ±2.5               PASS
                                   30             1,879,999,972                      -0.001              ±2.5               PASS
                                   20             1,879,999,976                       0.001              ±2.5               PASS
          3.80
                                   10             1,879,999,975                       0.001              ±2.5               PASS
                                    0             1,879,999,976                       0.001              ±2.5               PASS
                                   -10            1,879,999,978                       0.002              ±2.5               PASS
                                   -20            1,879,999,977                       0.002              ±2.5               PASS
                                   -30            1,879,999,971                      -0.002              ±2.5               PASS
          3.23                     25             1,879,999,972                      -0.001              ±2.5               PASS
          4.37                     25             1,879,999,971                      -0.002              ±2.5               PASS
          3.20                     25             1,879,999,974                       0.000              ±2.5               PASS


 Calculation;
      Frequency Tolerance (ppm) = Measurements Frequency (Hz) – Reference Frequency (Hz) / Reference Frequency (Hz) x 1000000




TÜV SÜD Zacta Ltd.                                                                                               Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                               FCC ID: JOYYAKF-1


                                              Page 24 of 27




11. Antenna requirement
According to FCC section 15.203, an intentional radiator shall be designed to ensure that no antenna other
than that furnished by the responsible party shall be used with the device.
The antenna is a special antenna mounted inside of the EUT. Therefore, the EUT complies with the antenna
requirement of FCC section 15.203.




TÜV SÜD Zacta Ltd.                                                                       Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                       FCC ID: JOYYAKF-1


                                             Page 25 of 27




12. Uncertainty of measurement
Expanded uncertainties stated are calculated with a coverage Factor k=2.
Please note that these results are not taken into account when determining compliance or non-compliance
with test result.

                               Test item                                   Measurement uncertainty

Conducted emission at mains port                                                     ±3.0dB

Radiated emission (9kHz – 30MHz)                                                     ±4.4dB

Radiated emission (30MHz – 1000MHz)                                                  ±4.5dB

Radiated emission (1000MHz – 26GHz)                                                  ±3.9dB




TÜV SÜD Zacta Ltd.                                                                    Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                    FCC ID: JOYYAKF-1


                                                    Page 26 of 27




13. Laboratory description
1. Location:
   TÜV SÜD Zacta Ltd. Yonezawa Testing Center
   4149-7 Hachimanpara 5-chome Yonezawa-shi Yamagata 992-1128 Japan
   Phone: +81-238-28-2880 Fax: +81-238-28-2888


2. Facility filing information:
 1) NVLAP accreditation: NVLAP Lab. code: 200306-0

 2) VLAC accreditation: Lab. code: VLAC-013
                                                     Conducted             Conducted        Radiated
                                  Radiated
              Site name                             emission for           emission for     emission            Expiry Date
                                  emission
                                                     mains port           telecom port       (CMAD)
  10m Semi-anechoic chamber                                                                 VLAC-013
                                                     VLAC-013
   3m Semi-anechoic chamber                                                                     -                Jul. 3, 2013
      Shielded room No.1              -                             VLAC-013                    -

 3) FCC filing:
          Site name                         Registration Number                                Expiry Date
             Site 2
                                                  91065                                        Oct.31, 2014
             Site 3
  10m Semi-anechoic chamber
   3m Semi-anechoic chamber                       540072                                       Jan. 9, 2016
      Shielded room No.1

 4) Industry Canada Oats site filing:
          Site name                   Sites on file: Oats 3m/10m                               Expiry Date
             Site 2                             4224A-2
             Site 3                             4224A-3
                                                                                               Jan. 23, 2015
   3m Semi-anechoic chamber                     4224A-4
  10m Semi-anechoic chamber                     4224A-5

 5) VCCI site filing:
                                                    Conducted                              Conducted
                                  Radiated
               Site name                           emission for           Expiry Date     emission for         Expiry Date
                                  emission
                                                    mains port                            telecom port
                  Site 2           R-137              C-133                                   T-1221
                                                                         Nov. 16, 2014                        Nov. 28, 2014
                  Site 3           R-138              C-134                                   T-1222
                                   R-2480            C-2722                                   T-1474           Jul. 3, 2013
   10m Semi-anechoic chamber
                                    G-81                -                                        -                   -
                                   R-2481            C-2723               Jul. 3, 2013        T-1475           Jul. 3, 2013
    3m Semi-anechoic chamber
                                    G-82                -                                        -                   -
         Shielded room No.1           -              C-2724                                   T-1476           Jul. 3, 2013

 6) TÜV SÜD PS authorization:
     Authorized as an EMC test laboratory

 7) TÜV Rheinland authorization:
     Authorized as an EMC test laboratory




TÜV SÜD Zacta Ltd.                                                                                       Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                       FCC ID: JOYYAKF-1


                                                           Page 27 of 27




Appendix A. Test equipment
[Antenna port conducted test]
     Equipment                     Company               Model No.             Serial No.     Cal. due        Cal. date
Spectrum analyzer            Agilent Technologies   E4440A                 US40420937        Oct. 2013      Oct. 19, 2012
Microwave cable              RS                     YH20_S1                N/A (S389)        Aug. 2013      Aug. 30, 2012
Microwave cable              SUHNER                 SUCOFLEX104/1.5m       199121/4          Oct. 2013       Oct. 7, 2012
Microwave cable              SUHNER                 SUCOFLEX104/1.5m       322086/4          Jul. 2013      Jul. 30, 2012
Attenuator                   Weinschel              56-10                  J4180             Nov. 2013      Nov. 12, 2012
Power splitter               ANRITSU                K240B                  020205            Nov. 2013      Nov. 12, 2012
Wideband radio
                             ROHDE&SCHWARZ          CMW500                 126079            Jul. 2013       Jul. 20, 2012
frequency tester
Operation type
temperature                  Espec                  PL3KP                  14016727          Dec. 2013      Dec. 27, 2012
controlled bath



Radiated emission
     Equipment                     Company               Model No.             Serial No.    Cal. Due         Cal. Date
EMI Receiver                 ROHDE&SCHWARZ          ECSI                   100764            Jul. 2013       Jul. 6, 2012
Preamplifier                 ANRITSU                MH648A                 M96057            Jun. 2013      Jun. 12, 2012
Loop antenna                 ROHDE&SCHWARZ          HFH2-Z2                892246/010        Sep. 2013      Sep. 14, 2012
TRILOG Antenna               Schwarzbeck            VULB9160               9160-3218         May 2014        May 2, 2012
Attenuator                   TME                    CFA-01NPJ-6            N/A (S274)        Jun. 2013      Jun. 12, 2012
Spectrum analyzer            Agilent Technologies   E4447A                 MY46180188        Mar. 2014       Mar. 8, 2013
Preamplifier                 Agilent Technologies   8449B                  3008A1008         Dec. 2013      Dec. 9, 2012
Double ridged guide
                             EMCO                   3115                   4328              Jan. 2014      Jan. 21, 2013
antenna
Attenuator                   AEROFLEX               40A-03                 081217-20         Feb. 2014      Feb. 23, 2013
Broad-Band Horn
                             Schwarzbeck            BBHA9170               BBHA9170189       May 2015        May 2, 2013
Antenna
Preamplifier                 TSJ                    MLA-1840-B03-35        1240332           May 2015        May 2, 2013
Double ridged guide
                             EMCO                   3115                   00058532          Aug. 2013      Aug. 31, 2012
antenna
Signal generator             ROHDE&SCHWARZ          SMB100A                100341            Oct. 2013       Oct. 2, 2012
Signal generator             ROHDE&SCHWARZ          SMR27                  839256/034        Jan. 2014      Jan. 30, 2013
Microwave cable              SUHNER                 SUCOFLEX104/1.5m       199121/4          Oct. 2013       Oct. 7, 2012
Wideband radio
                             ROHDE&SCHWARZ          CMW500                 126079            Jul. 2013       Jul. 20, 2012
frequency tester
                                                    SUCOFLEX104/9m         346316/4          Oct. 2013      Oct. 6, 2012
                                                    SUCOFLEX104/1m         322084/4          Oct. 2013      Oct. 6, 2012
Microwave cable              SUHNER
                                                    SUCOFLEX104/1.5m       317226/4          Oct. 2013      Oct. 6, 2012
                                                    SUCOFLEX104/7m         41625/6           Oct. 2013      Oct. 6, 2012
PC                           DELL                   DIMENSION E521         75465BX             N/A              N/A
Software                     TOYO Corporation       EP5/RE-AJ              0611193/V5.3.61     N/A              N/A
3m Semi-anechoic chamber     TOKIN                  N/A                    N/A (9002-NSA)    May 2013       May 19, 2012




TÜV SÜD Zacta Ltd.                                                                                   Report number: Z071C-13159
Test Report Rev.FCC-24E1.0                                                                                   FCC ID: JOYYAKF-1



Document Created: 2013-05-30 15:15:01
Document Modified: 2013-05-30 15:15:01

© 2024 FCC.report