DTS Bluetooth LE report

FCC ID: JOYYAKF-1

Test Report

Download: PDF
FCCID_1991458

                                                            Page 1 of 32




                                  TEST REPORT
                                           Report number : ZO71C—13156
                                              Issue date : May 23, 2013

     The device, as described herewith, was tested pursuant to applicable test procedure and complies with
     the requirements of;

                                                FCC Part15 Subpart C


     The test results are traceable to the international or national standards.

               Applicant                                :      KYOCERA Corporation

               Equipment under test (EUT)               :      Mobile Phone

               Model number                             : YAKF—1

               FCC ID                                   :_JOYYAKF—1


               Date oftest        _: April 18, 19, 24, May 23, 2013                                           —
               Test place         :    TUV SUD Zacta Ltd. Yonezawa Testing Center
                                       4149—7 Hachimanpara 5—chome
                                       Yonezawa—shi Yamagata 992—1128 Japan
                                       Phone: +81—238—28—2880 Fax: +81—238—28—2888
               Test results       :    Complied


    The results in this report are applicable only to the equipment tested.
    This report shall not be re—produced except in full without the written approval of TUV SUD Zacta Ltd.
    This test report must not be used by client to claim product certification, approval, or endorsement by
    NVLAP, NIST, or any agency of the federal government.



            Tested by         :         %;fi( %771//‘/
                                      Chiaki Kanno


            Tested by         :       fl?;\(ik;         Wfi?%/&/
                                      Taiki Watanabe


            Authorized by     :            ,<7/M       /W \
                                      Hiroaki Suzuki         &
                                      Manager of EMC Technical Department



                                                                                     nvilad
                                                                                     NVLAP LAB CODE 200306—0



TUV SUD Zacta Ltd.                                                                    ’         Report number: 2071C—13156
Test Report Rev.FCC—C1.0                                                                                FCC ID: JOYYAKF—1


                                                                          Page 2 of 32




Table of contents


                                                                                                                                                              Page
1. Summary of Test .................................................................................................................4
   1.1 Purpose of test ....................................................................................................................................... 4
   1.2 Standards ............................................................................................................................................... 4
   1.3 List of applied test to the EUT .............................................................................................................. 4
   1.4 Modification to the EUT by laboratory................................................................................................. 4
2. Equipment Under Test ........................................................................................................5
   2.1 General Description of equipment ....................................................................................................... 5
   2.2 EUT information ..................................................................................................................................... 5
   2.3 Variation of the family model(s)............................................................................................................ 6
   2.4 Operating channels and frequencies .................................................................................................. 6
   2.5 Description of Test mode ...................................................................................................................... 6
   2.6 Operating mode ..................................................................................................................................... 7
3. Configuration of equipment ...............................................................................................8
   3.1 Equipment(s) used................................................................................................................................. 8
   3.2 Cable(s) used ......................................................................................................................................... 8
   3.3 System configuration ............................................................................................................................ 8
4. 6dB Bandwidth ....................................................................................................................9
   4.1 Measurement procedure ....................................................................................................................... 9
   4.2 Limit......................................................................................................................................................... 9
   4.3 Measurement result ............................................................................................................................... 9
   4.4 Trace data ............................................................................................................................................. 10
5. Maximum Peak Output Power .......................................................................................... 11
   5.1 Measurement procedure ......................................................................................................................11
   5.2 Limit........................................................................................................................................................11
   5.3 Measurement result ..............................................................................................................................11
   5.4 Trace data ............................................................................................................................................. 12
6. Band Edge Compliance of RF Conducted Emissions....................................................13
   6.1 Measurement procedure ..................................................................................................................... 13
   6.2 Limit....................................................................................................................................................... 13
   6.3 Measurement result ............................................................................................................................. 13
   6.4 Trace data ............................................................................................................................................. 14
7. Spurious emissions - Conducted - ..................................................................................15
   7.1 Measurement procedure ..................................................................................................................... 15
   7.2 Limit....................................................................................................................................................... 15
   7.3 Measurement result ............................................................................................................................. 15
   7.4 Trace data ............................................................................................................................................. 16
8. Spurious Emissions - Radiated -......................................................................................19
   8.1 Measurement procedure ..................................................................................................................... 19
   8.2 Calculation method.............................................................................................................................. 20
   8.3 Limit....................................................................................................................................................... 20
   8.4 Test data................................................................................................................................................ 21
9. Restricted Band of Operation...........................................................................................22
   9.1 Measurement procedure ..................................................................................................................... 22

TÜV SÜD Zacta Ltd.                                                                                                                          Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                                                            FCC ID: JOYYAKF-1


                                                                         Page 3 of 32




   9.2 Limit....................................................................................................................................................... 22
   9.3 Measurement Result............................................................................................................................ 22
   9.4 Test data................................................................................................................................................ 23
10. Transmitter Power Spectral Density ..............................................................................25
   10.1 Measurement procedure ................................................................................................................... 25
   10.2 Limit..................................................................................................................................................... 25
   10.3 Measurement result ........................................................................................................................... 25
   10.4 Trace data ........................................................................................................................................... 26
   11.1 Measurement procedure ................................................................................................................... 27
   11.2 Calculation method............................................................................................................................ 27
   11.3 Limit ..................................................................................................................................................... 27
   11.4 Test data .............................................................................................................................................. 28
12. Antenna requirement ......................................................................................................29
13. Uncertainty of measurement ..........................................................................................30
14. Laboratory description ...................................................................................................31
Appendix A. Test equipment ................................................................................................32




TÜV SÜD Zacta Ltd.                                                                                                                         Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                                                           FCC ID: JOYYAKF-1


                                                  Page 4 of 32




1. Summary of Test
1.1 Purpose of test

   It is the original test in order to verify conformance to FCC Part 15 Subpart C.


1.2 Standards

   CFR47 FCC Part 15 Subpart C


 1.2.1 Test Methods

   ANSI C63.4-2003, KDB558074


 1.2.2 Deviation from standards

    None


1.3 List of applied test to the EUT

        Test items
                                                  Test items                      Condition              Result
          Section
15.247(a)(2)                     6dB Bandwidth                                    Conducted               PASS
15.247(b)(3)                     Maximum Peak Output Power                        Conducted               PASS
                                 Band Edge Compliance of RF Conducted
15.247(d)                                                                         Conducted               PASS
                                 Emissions
15.247(d)
                                                                                  Conducted
15.205                           Spurious Emissions                                                       PASS
                                                                                   Radiated
15.209
15.247(d)
15.205                           Restricted Bands of Operation                        Radiated            PASS
15.209
15.247(e)                        Transmitter Power Spectral Density               Conducted               PASS
15.207                           AC Power Line Conducted Emissions                Conducted               PASS


 1.3.1 Test set up

    Table-Top


1.4 Modification to the EUT by laboratory

    None




TÜV SÜD Zacta Ltd.                                                                               Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                 FCC ID: JOYYAKF-1


                                                  Page 5 of 32




2. Equipment Under Test
2.1 General Description of equipment

  EUT is the Mobile Phone.


2.2 EUT information

  Applicant                :   KYOCERA Corporation
                               Yokohama Office 2-1-1 Kagahara, Tsuzuki-ku Yokohama-shi, Kanagawa,
                               Japan
                               Phone: +81-45-943-6253 Fax: +81-45-943-6314
  Equipment under test     :   Mobile Phone

  Trade name               :   Kyocera

  Model number             :   YAKF-1

  Serial number            :   N/A

  EUT condition            :   Pre-Production

  Max. frequency           :   1.5GHz

  Power ratings            :   Battery: DC 3.8V

  Size                     :   (W) 134 × (D) 66 × (H) 10.9 mm

  Environment              :   Indoor and Outdoor use

  Terminal limitation      :   -20˚C to 60˚C

  RF Specification
  Protocol                 :   Bluetooth 4.0 + EDR

  Frequency range          :   2402MHz-2480MHz

  Number of RF             :   40 Channels
  Channels
  Modulation method/       :   GFSK (1Mbps)
  Data rate
  Channel separation       :   2MHz

  Output power             :   0.575mW

  Antenna type             :   Internal antenna

  Antenna gain             :   0dBi




TÜV SÜD Zacta Ltd.                                                                    Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                      FCC ID: JOYYAKF-1


                                               Page 6 of 32




2.3 Variation of the family model(s)

   Not applicable


2.4 Operating channels and frequencies

            Channel              Frequency [MHz]              Channel              Frequency [MHz]
               0                      2402                      20                      2442
               1                      2404                      21                      2444
               2                      2406                      22                      2446
               3                      2408                      23                      2448
               4                      2410                      24                      2450
               5                      2412                      25                      2452
               6                      2414                      26                      2454
               7                      2416                      27                      2456
               8                      2418                      28                      2458
               9                      2420                      29                      2460
              10                      2422                      30                      2462
              11                      2424                      31                      2464
              12                      2426                      32                      2466
              13                      2428                      33                      2468
              14                      2430                      34                      2470
              15                      2432                      35                      2472
              16                      2434                      36                      2474
              17                      2436                      37                      2476
              18                      2438                      38                      2478
              19                      2440                      39                      2480


2.5 Description of Test mode

 The EUT had been tested under operating condition.
 There are three channels have been tested as following:
                  Tested Channel                                        Frequency [MHz]
                       Low                                                   2402
                      Middle                                                 2440
                       High                                                  2480

 The pre-test has been conducted to determine the worst-case mode from all possible combinations between
 available modulations, data rates.

             Tested Channel                 Modulation Type                       Data Rate
             Low, Middle, High                  GFSK                               1Mbps

 The field strength of spurious emissions was measured at each position of all three axis X, Y and Z to
 compare the level, and the maximum noise.
 The worst emission was found in X axis and the worst case recorded.




TÜV SÜD Zacta Ltd.                                                                        Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                          FCC ID: JOYYAKF-1


                                            Page 7 of 32




2.6 Operating mode



  [Tx mode]
    i) Test program setup to the DM tool
    ii) Select a Test mode
        Operating frequency: Channel Low: 2402MHz, Channel Middle: 2440MHz, Channel High: 2480MHz
    iii) Start test mode


  [Rx mode]
    i) Test program setup to the DM tool
    ii) Select a Test mode
        Operating frequency: Channel Low: 2402MHz, Channel Middle: 2440MHz, Channel High: 2480MHz
    iii) Start test mode




TÜV SÜD Zacta Ltd.                                                                  Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                    FCC ID: JOYYAKF-1


                                                             Page 8 of 32




3. Configuration of equipment
3.1 Equipment(s) used

No.       Equipment         Company         Model No.                          Serial No.           FCC ID / DoC            Comment
 1    Mobile Phone         KYOCERA        YAKF-1                             N/A                   JOYYAKF-1              EUT
 2    AC Adapter           SoftBank       AC01-MU-K                          N/A                   -                      *
  *: AC power line Conducted Emission Test.


3.2 Cable(s) used

 No.              Cable              Length[m]                              Shield               Connector                Comment
  a    DC cable                          1.5                                 No                    Plastic            *
  *: AC power line Conducted Emission Test.


3.3 System configuration


     1. Mobile Phone
        (EUT)

                                                 a.                                    #     2. AC Adapter                        AC 120V
                            USB
                                                                                                                                  60Hz




                                                                                                        # : Un-detachable cable




Note1: Numbers assigned to equipment or cables on this diagram correspond to the list in “3.1 Equipment(s) used” and “3.2 Cable(s) used”.




TÜV SÜD Zacta Ltd.                                                                                                  Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                                    FCC ID: JOYYAKF-1


                                                           Page 9 of 32




4. 6dB Bandwidth
4.1 Measurement procedure
 [FCC 15.247(a)(2), KDB558074]

  The bandwidth at 6dB down from the highest inband spectral density is measured with a spectrum analyzer
  connected to the antenna terminal, while EUT is operating in transmission mode at the appropriate center
  frequency.

  The spectrum analyzer is set to;
   - RBW=100kHz, VBW=300kHz, Span=3MHz, Sweep=auto, Detector=Peak, Trace mode=Max hold
  The EUT was set to operate with following conditions.
   - Channel Low: 2402MHz, Channel Middle: 2440MHz, Channel High: 2480MHz
  The test mode of EUT is as follows.
   - Tx mode


  - Test configuration



                                                                                                      Spectrum
                       EUT                                                         Attenuator         Analyzer
                                               Coaxial cable




4.2 Limit

  The minimum permissible 6dB bandwidth is 500kHz.


4.3 Measurement result

Date                       :   Apr. 18, 2013                          Test personnel     :
Temperature                :   20.0 [˚C]
Humidity                   :   50.0 [%]                               Tested by          :
Test place                 :   Shielded room                                                    Chiaki Kanno




    Channel                    Frequency [MHz]                                    6dB bandwidth [MHz]


        Low                         2402                                                  0.708

      Middle                        2440                                                  0.712

       High                         2480                                                  0.710




TÜV SÜD Zacta Ltd.                                                                                         Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                           FCC ID: JOYYAKF-1


                                  Page 10 of 32




4.4 Trace data


                 Channel Low




                 Channel Middle




                 Channel High




TÜV SÜD Zacta Ltd.                                Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                  FCC ID: JOYYAKF-1


                                                                       Page 11 of 32




5. Maximum Peak Output Power
5.1 Measurement procedure
 [FCC 15.247(b)(3), 15.31(e), KDB558074]

  The peak power is measured with a spectrum analyzer connected to the antenna terminal, while EUT is
  operating in transmission mode at the appropriate center frequency.

  The spectrum analyzer is set to;
   — RBW=1MHz, VBW=8MHz, Span=3MHz, Sweep=auto, Detector=Peak, Trace mode=Max hold
  The EUT was set to operate with following conditions.
   — Channel Low: 2402MHz, Channel Middle: 2440MHz, Channel High: 2480MHz
  The test mode of EUT is as follows.
   — Tx mode



  — Test configuration




                                                                                                                  Spectrum
                          EUT                                                                  Attenuator         Analyzer
                                                           Coaxial cable




5.2 Limit

  1W (1000mW) or less



5.3 Measurement result

Date                            :     Apr. 18, 2013                                Test personnel
Temperature                     :     20.0 [C]
Humidity                        :     50.0 [%]                                     Tested by           :
Test place                      :      Shielded room                                                        Chiaki Kanno



                                                      .                                             Peak            20L
                          Frequency              Reading         Factor                Level                       Limit
     Channel                                                                                   Output Power                        Result
                                (MHz)             (dBm)           (dB)                 (dBm)                      (mW)
                                                                                                    {mW)
        Low                         2402          —14.11          11.37                —2.74        0.532         1000              PASS
      Middle                        2440          —14.33          11.37                —2.96        0.506         1000              PASS
        High                        2480          ~13.77          11.37                —2.40        0.575         1000              PASS


 Calculation;
     Reading (dBm) + Factor (dB) = Level (dBm)

      19e Ec CEmm io
      P= 10     aximim    Pea              wer   (mv\,)




TUV SUD Zacta Ltd                                                                                                          Report number: 20710—13156
Test Report RevFCC—C1.0                                                                                                           FCC ID: JOYYAKE—A1


                                  Page 12 of 32




5.4 Trace data

                 Channel Low




                 Channel Middle




                 Channel High




TÜV SÜD Zacta Ltd.                                Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                  FCC ID: JOYYAKF-1


                                                           Page 13 of 32




6. Band Edge Compliance of RF Conducted Emissions
6.1 Measurement procedure
 [FCC 15.247(d), KDB558074]

  The Band Edge is measured with a spectrum analyzer connected to the antenna terminal, while EUT is
  operating in transmission mode at the appropriate center frequency.

  The spectrum analyzer is set to;
   - RBW=100kHz, VBW=100kHz, Span=Arbitrary setting, Sweep=auto, Detector=Peak,
     Trace mode=Max hold
  The EUT was set to operate with following conditions.
   - Channel Low: 2402MHz, Channel High: 2480MHz
  The test mode of EUT is as follows.
   - Tx mode


  - Test configuration



                                                                                                         Spectrum
                       EUT                                                           Attenuator          Analyzer
                                               Coaxial cable




6.2 Limit

 In any 100kHz bandwidth outside the frequency band the radio frequency power that is produced by the intentional radiator
  shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired
 power.


6.3 Measurement result

Date                       :   Apr. 18, 2013                          Test personnel         :
Temperature                :   20.0 [˚C]
Humidity                   :   50.0 [%]                               Tested by              :
Test place                 :   Shielded room                                                      Chiaki Kanno


                                  RF
                                         Band-edge     Band-edge           Difference
                 Frequency      Power                                                                 Limit
 Channel                                 Frequency        Level              Level                                               Result
                    (MHz)        Level                                                                (dBm)
                                           (MHz)          (dBm)              (dBm)
                                (dBm)
    Low            2402.00      -10.42    2389.36         -75.94             65.52      At least 20dB below from peak of RF      PASS
    High           2480.00       -9.89    2483.55         -75.98             66.09      At least 20dB below from peak of RF      PASS




TÜV SÜD Zacta Ltd.                                                                                              Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                                FCC ID: JOYYAKF-1


                                Page 14 of 32




6.4 Trace data


                 Channel Low




                 Channel High




TÜV SÜD Zacta Ltd.                              Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                FCC ID: JOYYAKF-1


                                                            Page 15 of 32




7. Spurious emissions - Conducted -
7.1 Measurement procedure
 [FCC 15.247(d), KDB558074]

  The spurious emissions (Conducted) are measured with a spectrum analyzer connected to the antenna
  terminal, while EUT is operating in transmission mode at the appropriate center frequency.

  The spectrum analyzer is set to;
   - RBW=100kHz, VBW=300kHz, Span=Arbitrary setting, Sweep=auto, Detector=Peak,
     Trace mode=Max hold
  The EUT was set to operate with following conditions.
   - Channel Low: 2402MHz, Channel Middle: 2440MHz, Channel High: 2480MHz
  The test mode of EUT is as follows.
   - Tx mode


  - Test configuration



                                                                                                      Spectrum
                       EUT                                                         Attenuator         Analyzer
                                                Coaxial cable




7.2 Limit

 In any 100kHz bandwidth outside the frequency band the radio frequency power that is produced by the intentional radiator
  shall be at least 20dB below that in the 100kHz bandwidth within the band that contains the highest level of the desired
 power.


7.3 Measurement result

Date                        :   Apr. 18, 2013                          Test personnel    :
Temperature                 :   20.0 [˚C]
Humidity                    :   50.0 [%]                               Tested by         :
Test place                  :   Shielded room                                                   Chiaki Kanno


                           Frequency                       Limit
Channel                                                                                         Results Chart          Result
                             [MHz]                          [dB]
   Low                        2402          At least 20dB below from peak of RF              See the trace Data         PASS
  Middle                      2440          At least 20dB below from peak of RF              See the trace Data         PASS
   High                       2480          At least 20dB below from peak of RF              See the trace Data         PASS




TÜV SÜD Zacta Ltd.                                                                                         Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                           FCC ID: JOYYAKF-1


                           Page 16 of 32




7.4 Trace data

Channel Low
30MHz-1GHz                         1GHz-5GHz




5GHz-10GHz                         10GHz-15GHz




15GHz-20GHz                          20GHz-25GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                   FCC ID: JOYYAKF-1


                           Page 17 of 32




Channel Middle
30MHz-1GHz                         1GHz-5GHz




5GHz-10GHz                         10GHz-15GHz




15GHz-20GHz                          20GHz-25GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                   FCC ID: JOYYAKF-1


                           Page 18 of 32




Channel High
30MHz-1GHz                         1GHz-5GHz




5GHz-10GHz                         10GHz-15GHz




15GHz-20GHz                          20GHz-25GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                   FCC ID: JOYYAKF-1


                                                Page 19 of 32




8. Spurious Emissions - Radiated -

8.1 Measurement procedure
 [FCC 247(d), 15,205, 15.209]

   Test was applied by following conditions.

  Test method                      :   ANSI C63.4
  Frequency range                  :   9kHz to 25GHz
  Test place                       :   3m Semi-anechoic chamber
  EUT was placed on                :   FRP table / (W)2.0m × (D)1.0m × (H)0.8m
  Antenna distance                 :   3m

  Test receiver setting                Below 1GHz
   - Detector                      :   Average (9kHz-90kHz, 110kHz-490kHz), Quasi-peak
   - Bandwidth                     :   200Hz, 120kHz
  Spectrum analyzer setting            Above 1GHz
   - Peak                          :   RBW=1MHz, VBW=1MHz, Span=0Hz, Sweep=auto
   - Average                       :   RBW=1MHz, VBW=10Hz, Span=0Hz, Sweep=auto
                                       Display mode=Linear


 Radiated emission measurements are performed at 3m distance with the broadband antenna (Loop
 antenna, TRILOG antenna and Double ridged guide antenna). The antenna is positioned both the horizontal
 and vertical planes of polarization and height is varied 1m to 4m and stopped at height producing the
 maximum emission. As for the Loop antenna, it is positioned with its plane vertical, and the center of the
 Loop antenna is 1m above the ground plane.
 The EUT is Placed on a turntable, which is 0.8m above ground plane. The turntable shall be rotated for 360
 degrees to determine the position of maximum emission level. The test results represent the worst case
 emission for each emission with manipulating the EUT, support equipment, interconnecting cables and
 varying the mode of operation. Sufficient time for the EUT, support equipment, and test equipment are
 allowed in order for them to warm up to their normal operating condition.
   The EUT was set to operate with following conditions.
    - Channel Low: 2402MHz, Channel Middle: 2440MHz, Channel High: 2480MHz
   The test mode of EUT is as follows.
    - Tx mode, Rx mode

  - Test configuration




TÜV SÜD Zacta Ltd.                                                                       Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                         FCC ID: JOYYAKF-1


                                                       Page 20 of 32




8.2 Calculation method

[9kHz to 150kHz]
Emission level = Reading + (Ant. factor + Cable system loss )
Margin = Limit – Emission level



[150kHz to 25GHz]
Emission level = Reading + (Ant. factor + Cable system loss – Amp. Gain)
Margin = Limit – Emission level



8.3 Limit

          Frequency                                  Field strength                       Distance
            [MHz]                         [uV/m]                        [dBuV/m]             [m]
          0.009-0.490                2400 / F [kHz]                    20logE [uV/m]         300
          0.490-1.705                24000 / F [kHz]                   20logE [uV/m]          30
            1.705-30                      30                               29.5               30
              30-88                      100                               40.0               3
             88-216                      150                               43.5               3
            216-960                      200                               46.0               3
          Above 960                      300                               54.0               3



Note:
 1. The lower limit shall apply at the transition frequencies.
 2. Emission level [dBuV/m] = 20log Emission [uV/m]
 3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on average
  detector, however, the peak field strength of any emission shall not exceed the maximum permitted
  average limits, specified above by more than 20dB under any condition modulation.




TÜV SÜD Zacta Ltd.                                                                        Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                          FCC ID: JOYYAKF-1


                                                      Page 21 of 32




8.4 Test data

Date                       :   Apr. 19, 2013                     Test personnel   :
Temperature                :   21.0 [˚C]
Humidity                   :   31.3 [%]                          Tested by        :
Test place                 :   3m Semi-anechoic chamber                                Chiaki Kanno


Channel Low




Channel Middle




Channel High




    Note:
     1. Emission Level (Margin) = Limit - [Reading + Factor ( Antenna + Cable – Amp)]
     2. No emission were detected in frequency range 9kHz to 1000MHz at the 3 meters distance.
     3. No emission was detected in the receive mode.




TÜV SÜD Zacta Ltd.                                                                                Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                  FCC ID: JOYYAKF-1


                                                Page 22 of 32




9. Restricted Band of Operation

9.1 Measurement procedure
 [FCC 247(d), 15,205, 15.209]

   Test was applied by following conditions.

  Test method                      :   ANSI C63.4
  Test place                       :   3m Semi-anechoic chamber
  EUT was placed on                :   FRP table / (W)2.0m × (D)1.0m × (H)0.8m
  Antenna distance                 :   3m

  Spectrum analyzer setting
   - Peak                          :   RBW=1MHz, VBW=1MHz, Span=Arbitrary setting, Sweep=auto
   - Average                       :   RBW=1MHz, VBW=10Hz, Span=Arbitrary setting, Sweep=auto
                                       Display mode=Linear


 Radiated emission measurements are performed at 3m distance with the broadband antenna (Double
 ridged guide antenna). The antenna is positioned both the horizontal and vertical planes of polarization and
 height is varied 1m to 4m and stopped at height producing the maximum emission.
 The EUT is Placed on a turntable, which is 0.8m above ground plane. The turntable shall be rotated for 360
 degrees to determine the position of maximum emission level. The test results represent the worst case
 emission for each emission with manipulating the EUT, support equipment, interconnecting cables and
 varying the mode of operation. Sufficient time for the EUT, support equipment, and test equipment are
 allowed in order for them to warm up to their normal operating condition.
   The EUT was set to operate with following conditions.
    - Channel Low: 2402MHz, Channel High: 2480MHz
   The test mode of EUT is as follows.
    - Tx mode

  - Test configuration




9.2 Limit

 Emission at the boundary of the restricted band provided by 15.205 shall be lower than 15.209 limit.



9.3 Measurement Result

            Channel             Frequency [MHz]                   Results Chart              Result
              Low                    2402                       See the Trace Data            Pass
             High                    2480                       See the Trace Data            Pass


TÜV SÜD Zacta Ltd.                                                                          Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                            FCC ID: JOYYAKF-1


                                                     Page 23 of 32




9.4 Test data

Date                       :   Apr. 24, 2013                    Test personnel   :
Temperature                :   21.5 [˚C]
Humidity                   :   33.5 [%]                         Tested by        :
Test place                 :   3m Semi-anechoic chamber                              Chiaki Kanno


Channel Low
Horizontal
Peak                                                          Average




Vertical
Peak                                                          Average




TÜV SÜD Zacta Ltd.                                                                              Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                FCC ID: JOYYAKF-1


                           Page 24 of 32




Channel High
Horizontal
Peak                                Average




Vertical
Peak                                Average




TÜV SÜD Zacta Ltd.                            Report number: Z071C-13156
Test Report Rev.FCC-C1.0                              FCC ID: JOYYAKF-1


                                                             Page 25 of 32




10. Transmitter Power Spectral Density
10.1 Measurement procedure
 [FCC 15.247(d), KDB558074]

  The peak power is measured with a spectrum analyzer connected to the antenna terminal, while EUT is
  operating in transmission mode at the appropriate center frequency.

  The spectrum analyzer is set to;
   - RBW=3kHz, VBW=10kHz, Span=1MHz, Sweep=Auto, Detector=Peak, Trace mode=Max hold
  The EUT was set to operate with following conditions.
   - Channel Low: 2402MHz, Channel Middle: 2440MHz, Channel High: 2480MHz
  The test mode of EUT is as follows.
   - Tx mode


  - Test configuration



                                                                                                          Spectrum
                       EUT                                                          Attenuator            Analyzer
                                                 Coaxial cable




10.2 Limit

  The peak power spectral density shall not be greater than 8dBm in any 3kHz band.


10.3 Measurement result

Date                         :   Apr. 18 2013                           Test personnel      :
Temperature                  :   20.0 [˚C]
Humidity                     :   50.0 [%]                               Tested by           :
Test place                   :   Shielded room                                                   Chiaki Kanno



                      Frequency       Reading       Factor            Level         Limit        Margin
    Channel                                                                                                   Result
                           (MHz)       (dBm)         (dB)             (dBm)         (dBm)        (dBm)

       Low                 2402.00     -24.03        11.37            -12.66        8.00         20.66        PASS
     Middle                2440.00     -24.05        11.37            -12.68        8.00         20.68        PASS
       High                2480.00     -23.48        11.37            -12.11        8.00         20.11        PASS



 Calculation;
    Transmitter Power Spectral Density Level (Margin) = Limit – (Reading + Factor)




TÜV SÜD Zacta Ltd.                                                                                             Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                               FCC ID: JOYYAKF-1


                                  Page 26 of 32




10.4 Trace data


                 Channel Low




                 Channel Middle




                 Channel High




TÜV SÜD Zacta Ltd.                                Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                  FCC ID: JOYYAKF-1


                                                      Page 27 of 32




11. AC Power Line Conducted Emissions

11.1 Measurement procedure
 [FCC 15.207]

  Test was applied by following conditions.

  Test method                              :   ANSI C63.4
  Frequency range                          :   0.15MHz to 30MHz
  Test place                               :   10m Semi-anechoic chamber
  EUT was placed on                        :   FRP table / (W)2.0m × (D)1.0m × (H)0.8m
  Vertical Metal Reference Plane           :   (W)2.0m × (H)2.0m 0.4m away from EUT
  Test receiver setting
   - Detector                              :   Quasi-peak, Average
   - Bandwidth                             :   9kHz

  EUT and peripherals are connected to 50Ω/50μH Line Impedance Stabilization Network (LISN) which are
  connected to reference ground plane, and are placed 80cm away from EUT. Excess of AC power cable is
  bundled in center.
  LISN for peripheral is terminated in 50Ω.
  EUT operating mode is selected to emit the maximum noise. Overall frequency range is investigated with
  spectrum analyzer using peak detector. Maximum emission configuration is determined by manipulating the
  EUT, peripherals, interconnecting cables. Then, emission measurements are performed with test receiver in
  above setting to each current-carrying conductor of the mains port. Sufficient time for EUT, peripherals and
  test equipment is provided in order for them to warm up to their normal operating condition. If the average
  limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet both limits.

  - Test configuration




11.2 Calculation method

  Emission level = Reading + (LISN. factor + Cable system loss)
  Margin = Limit – Emission level


11.3 Limit

             Frequency                                                    Limit
                [MHz]                              QP [dBuV]                           AV [dBuV]
               0.15-0.5                                66-56*                             56-46*
                 0.5-5                                   56                                 46
                 5-30                                    60                                 50
*: The limit decreases linearly with the logarithm of the frequency in the range 0.15MHz to 0.5MHz.

TÜV SÜD Zacta Ltd.                                                                          Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                            FCC ID: JOYYAKF-1


                           Page 28 of 32




11.4 Test data




TÜV SÜD Zacta Ltd.                         Report number: Z071C-13156
Test Report Rev.FCC-C1.0                           FCC ID: JOYYAKF-1


                                              Page 29 of 32




12. Antenna requirement
According to FCC section 15.203, an intentional radiator shall be designed to ensure that no antenna other
than that furnished by the responsible party shall be used with the device.
The antenna is a special antenna mounted inside of the EUT. Therefore, the EUT complies with the antenna
requirement of FCC section 15.203.




TÜV SÜD Zacta Ltd.                                                                       Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                         FCC ID: JOYYAKF-1


                                             Page 30 of 32




13. Uncertainty of measurement
Expanded uncertainties stated are calculated with a coverage Factor k=2.
Please note that these results are not taken into account when determining compliance or non-compliance
with test result.

                               Test item                                   Measurement uncertainty

Conducted emission at mains port                                                     ±3.0dB

Radiated emission (9kHz – 30MHz)                                                     ±4.4dB

Radiated emission (30MHz – 1000MHz)                                                  ±4.5dB

Radiated emission (1000MHz – 26GHz)                                                  ±3.9dB




TÜV SÜD Zacta Ltd.                                                                    Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                      FCC ID: JOYYAKF-1


                                                    Page 31 of 32




14. Laboratory description
1. Location:
   TÜV SÜD Zacta Ltd. Yonezawa Testing Center
   4149-7 Hachimanpara 5-chome Yonezawa-shi Yamagata 992-1128 Japan
   Phone: +81-238-28-2880 Fax: +81-238-28-2888


2. Facility filing information:
 1) NVLAP accreditation: NVLAP Lab. code: 200306-0

 2) VLAC accreditation: Lab. code: VLAC-013
                                                     Conducted             Conducted        Radiated
                                  Radiated
              Site name                             emission for           emission for     emission            Expiry Date
                                  emission
                                                     mains port           telecom port       (CMAD)
  10m Semi-anechoic chamber                                                                 VLAC-013
                                                     VLAC-013
   3m Semi-anechoic chamber                                                                     -                Jul. 3, 2013
      Shielded room No.1              -                             VLAC-013                    -

 3) FCC filing:
          Site name                         Registration Number                                Expiry Date
             Site 2
                                                  91065                                        Oct.31, 2014
             Site 3
  10m Semi-anechoic chamber
   3m Semi-anechoic chamber                       540072                                       Jan. 9, 2016
      Shielded room No.1

 4) Industry Canada Oats site filing:
          Site name                   Sites on file: Oats 3m/10m                               Expiry Date
             Site 2                             4224A-2
             Site 3                             4224A-3
                                                                                               Jan. 23, 2015
   3m Semi-anechoic chamber                     4224A-4
  10m Semi-anechoic chamber                     4224A-5

 5) VCCI site filing:
                                                    Conducted                              Conducted
                                  Radiated
               Site name                           emission for           Expiry Date     emission for         Expiry Date
                                  emission
                                                    mains port                            telecom port
                  Site 2           R-137              C-133                                   T-1221
                                                                         Nov. 16, 2014                        Nov. 28, 2014
                  Site 3           R-138              C-134                                   T-1222
                                   R-2480            C-2722                                   T-1474           Jul. 3, 2013
   10m Semi-anechoic chamber
                                    G-81                -                                        -                   -
                                   R-2481            C-2723               Jul. 3, 2013        T-1475           Jul. 3, 2013
    3m Semi-anechoic chamber
                                    G-82                -                                        -                   -
         Shielded room No.1           -              C-2724                                   T-1476           Jul. 3, 2013

 6) TÜV SÜD PS authorization:
     Authorized as an EMC test laboratory

 7) TÜV Rheinland authorization:
     Authorized as an EMC test laboratory




TÜV SÜD Zacta Ltd.                                                                                       Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                         FCC ID: JOYYAKF-1


                                                         Page 32 of 32




Appendix A. Test equipment
[Antenna port conducted test]
     Equipment                   Company               Model No.             Serial No.    Cal. due        Cal. date
Spectrum analyzer          Agilent Technologies   E4440A                 US40420937        Oct. 2013      Oct. 19, 2012
Microwave cable            RS                     YH_13S5                N/A (S403)        May 2013       May 10, 2012
Attenuator                 Weinschel              56-10                  J4180             Nov. 2013      Nov. 12, 2012



Radiated emission
     Equipment                   Company               Model No.             Serial No.    Cal. Due         Cal. Date
EMI Receiver               ROHDE&SCHWARZ          ECSI                   100764            Jul. 2013       Jul. 6, 2012
Preamplifier               ANRITSU                MH648A                 M96057            Jun. 2013      Jun. 12, 2012
Loop antenna               ROHDE&SCHWARZ          HFH2-Z2                892246/010        Sep. 2013      Sep. 14, 2012
TRILOG Antenna             Schwarzbeck            VULB9160               9160-3218         May 2014        May 2, 2012
Attenuator                 TME                    CFA-01NPJ-6            N/A (S274)        Jun. 2013      Jun. 12, 2012
Spectrum analyzer          Agilent Technologies   E4447A                 MY46180188        Mar. 2014       Mar. 8, 2013
Preamplifier               Agilent Technologies   8449B                  3008A1008         Dec. 2013      Dec. 9, 2012
Double ridged guide
                           EMCO                   3115                   4328              Jan. 2014      Jan. 21, 2013
antenna
Attenuator                 AEROFLEX               40A-03                 081217-20         Feb. 2014      Feb. 23, 2013
Broad-Band Horn
                           Schwarzbeck            BBHA9170               BBHA9170189       Apr. 2013       Apr. 20, 2010
Antenna
Preamplifier               TSJ                    MLA-1840-B03-35        1240332           Apr. 2013      Apr. 20, 2010
                                                  SUCOFLEX104/9m         346316/4          Oct. 2013      Oct. 6, 2012
                                                  SUCOFLEX104/1m         322084/4          Oct. 2013      Oct. 6, 2012
Microwave cable            SUHNER
                                                  SUCOFLEX104/1.5m       317226/4          Oct. 2013      Oct. 6, 2012
                                                  SUCOFLEX104/7m         41625/6           Oct. 2013      Oct. 6, 2012
PC                         DELL                   DIMENSION E521         75465BX             N/A               N/A
Software                   TOYO Corporation       EP5/RE-AJ              0611193/V5.3.61     N/A               N/A
3m Semi-anechoic chamber   TOKIN                  N/A                    N/A (9002-NSA)    May 2013       May 19, 2012



Conducted emission at mains port
     Equipment                 Company                 Model No.             Serial No.     Cal. due        Cal. date
EMI Receiver               ROHDE&SCHWARZ          ECSI                   100764            Jul. 2013       Jul. 6, 2012
Attenuator                 HUBER+SUHNER           6810.01.A              N/A (S411)        Jun. 2013      Jun. 25, 2012
Line impedance
                           Kyoritsu Electrical
stabilization network                             KNW-407F               8-2003-1          Mar. 2014      Mar. 12, 2013
                           Works, Ltd.
for EUT
Coaxial cable              FUJIKURA               5D-2W/4m               N/A (S350)        Feb. 2014       Feb. 4, 2013
Coaxial cable              FUJIKURA               5D-2W/1m               N/A (S193)        Feb. 2014       Feb. 4, 2013
Coaxial cable              SUHNER                 RG214/U/10m            N/A (S194)        Feb. 2014       Feb. 4, 2013
PC                         DELL                   DIMENSION              75465BX             N/A               N/A




TÜV SÜD Zacta Ltd.                                                                                 Report number: Z071C-13156
Test Report Rev.FCC-C1.0                                                                                   FCC ID: JOYYAKF-1



Document Created: 2013-05-30 15:09:36
Document Modified: 2013-05-30 15:09:36

© 2024 FCC.report