Part 24E Test report

FCC ID: JOYKC-01

Test Report

Download: PDF
FCCID_2430997

                                                            Page 1 of 26




                                 TEST REPORT
                                         Report number : Z101C—14087
                                          Issue date : October 17, 2014

    The device, as described herewith, was tested pursuant to applicable test procedure and complies with
    the requirements of;

                                              FCC Part 24 Subpart E

    The test results are traceable to the international or national standards.

              Applicant                                 :       KYOCERA Corporation

               Equipment under test (EUT)               :       Mobile Phone

               Model number                             :       KC—01

               FCC ID                                   :      JOYKC—O1


              Date of test       ;    Sgptenj_ber 2, October 2, 8, 9, 10, 2014
              Test place         :    TUV SUD Zacta Ltd. Yonezawa Testing Center
                                      4149—7 Hachimanpara 5—chome
                                      Yonezawa—shi Yamagata 992—1128 Japan
                                      Phone: +81—238—28—2880 Fax: +81—238—28—2888
              Test results       :    Complied


    The results in this report are applicable only to the equipment tested.
    This report shall not be re—produced except in full without the written approval of TUV SUD Zacta Ltd.
    This test report must not be used by client to claim product certification, approval, or endorsement by
    NVLAP, NIST, or any agency of the federal government.




            Tested by        ;       //%a%          %W’                    %‘ YYMM
                                     Chiaki Kanno                           Taiki Watanabe



                                                                             I

            Authorized by    :                   /                         /4
                                     EijiAl;il;z/                  #             *
                                     DeputyBeneral Manager of EMC Technical Department



                                                                                                          Lao)
                                                                                             NVLAP LAB CODE 200306—0



TUV SUD Zacta Ltd.                                                                                      Report number: Z101C—14087
Test Report Rev.FCC—24E1.0                                                                                     FCC ID: JOYKC—01


                                                                          Page 2 of 26




Table of contents


                                                                                                                                                              Page
1. Summary of Test .................................................................................................................4
   1.1 Purpose of test ....................................................................................................................................... 4
   1.2 Standards ............................................................................................................................................... 4
   1.3 List of applied test to the EUT .............................................................................................................. 4
   1.4 Modification to the EUT by laboratory................................................................................................. 4
2. Equipment Under Test ........................................................................................................5
   2.1 General Description of equipment ....................................................................................................... 5
   2.2 EUT information ..................................................................................................................................... 5
   2.3 Variation of the family model(s)............................................................................................................ 6
   2.4 Description of Test mode ...................................................................................................................... 6
3. Configuration of equipment ...............................................................................................7
   3.1 Equipment(s) used................................................................................................................................. 7
   3.2 System configuration ............................................................................................................................ 7
4. Conducted Output Power ...................................................................................................8
   4.1 Measurement procedure ....................................................................................................................... 8
   4.2 Measurement result ............................................................................................................................... 8
5. Equivalent Isotropic Radiated Power ................................................................................9
   5.1 Measurement procedure ....................................................................................................................... 9
   5.2 Calculation method................................................................................................................................ 9
   5.3 Limit......................................................................................................................................................... 9
   5.4 Test data................................................................................................................................................ 10
6. Peak to Average Ratio....................................................................................................... 11
   6.1 Measurement procedure ......................................................................................................................11
   6.2 Limit........................................................................................................................................................11
   6.3 Measurement result ..............................................................................................................................11
   6.4 Trace data ............................................................................................................................................. 12
7. Occupied Bandwidth.........................................................................................................13
   7.1 Measurement procedure ..................................................................................................................... 13
   7.2 Limit....................................................................................................................................................... 13
   7.3 Measurement result ............................................................................................................................. 13
   7.4 Trace data ............................................................................................................................................. 14
8. Band Edge Spurious and Harmonic at Antenna Terminals ...........................................15
   8.1 Measurement procedure ..................................................................................................................... 15
   8.2 Limit....................................................................................................................................................... 15
   8.3 Measurement result ............................................................................................................................. 15
   8.4 Trace data ............................................................................................................................................. 16
9. Radiated Emissions and Harmonic Emissions...............................................................20
   9.1 Measurement procedure ..................................................................................................................... 20
   9.2 Calculation method.............................................................................................................................. 20
   9.3 Limit....................................................................................................................................................... 20
   9.4 Test data................................................................................................................................................ 21
10. Frequency Stability .........................................................................................................22
   10.1 Measurement procedure ................................................................................................................... 22

TÜV SÜD Zacta Ltd.                                                                                                                          Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                                                          FCC ID: JOYKC-01


                                                                         Page 3 of 26




   10.2 Limit..................................................................................................................................................... 22
   10.3 Measurement result ........................................................................................................................... 23
11. Uncertainty of measurement ..........................................................................................24
12. Laboratory description ...................................................................................................25
Appendix A. Test equipment ................................................................................................26




TÜV SÜD Zacta Ltd.                                                                                                                        Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                                                        FCC ID: JOYKC-01


                                                  Page 4 of 26




1. Summary of Test
1.1 Purpose of test

   It is the original test in order to verify conformance to FCC Part 24 Subpart E.


1.2 Standards

   CFR47 FCC Part 24 Subpart E


 1.2.1 Test Methods

   ANSI/TIA/EIA-603-C-2004


 1.2.2 Deviation from standards

    None


1.3 List of applied test to the EUT

              Test items
                                                  Test items                      Condition              Result
               Section
2.1046                           Conducted Output Power                           Conducted               PASS
                                 Effective Radiated Power
24.232(c)                                                                             Radiated            PASS
                                 Equivalent Isotropic Radiated Power
24.232(d)                        Peak to Average Ratio                            Conducted               PASS
24.238(a)
                                 Occupied Bandwidth                               Conducted               PASS
2.1049
24.238(a)                        Band Edge Spurious and Harmonic at
                                                                                  Conducted               PASS
2.1051                           Antenna Terminal
24.238(a)                        Radiated emissions and
                                                                                      Radiated            PASS
2.1053                           Harmonic Emissions
24.235
                                 Frequency Stability                              Conducted               PASS
2.1055


 1.3.1 Test set up

    Table-Top


1.4 Modification to the EUT by laboratory

    None




TÜV SÜD Zacta Ltd.                                                                               Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                               FCC ID: JOYKC-01


                                                    Page 5 of 26




2. Equipment Under Test
2.1 General Description of equipment

  EUT is the Mobile Phone.


2.2 EUT information

  Applicant                  :   KYOCERA Corporation
                                 Yokohama Office 2-1-1 Kagahara, Tsuzuki-ku Yokohama-shi, Kanagawa,
                                 Japan
                                 Phone: +81-45-943-6253 Fax: +81-45-943-6314
  Equipment under test       :   Mobile Phone

  Trade name                 :   Kyocera

  Model number               :   KC-01

  Serial number              :   N/A

  EUT condition              :   Pre-Production

  Power ratings              :   Battery: DC 3.8V

  Size                       :   (W) 64 × (D) 11.1 × (H) 127.0 mm

  Environment                :   Indoor and Outdoor use

  Terminal limitation        :   -20˚C to 60˚C

  RF Specification
  Frequency of               :   Up Link
  Operation                       GSM1900: 1850.2-1909.8MHz

                                 Down Link
                                  GSM1900: 1930.2-1989.8MHz

  Modulation type            :   GSM1900: GMSK

  Emission designator        :   GSM1900: 245KGXW

  Output power               :   GSM1900: 0.977W EIRP (29.9dBm)

  Antenna type               :   Internal antenna

  Antenna gain               :   -0.4dBi




TÜV SÜD Zacta Ltd.                                                                      Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                      FCC ID: JOYKC-01


                                               Page 6 of 26




2.3 Variation of the family model(s)

     Not applicable


2.4 Description of Test mode

 The EUT had been tested under operating condition.
 There are three channels have been tested as following:

                      Band                       Channel                        Frequency
                                                   512                          1850.2MHz
                  GSM1900                          661                          1880.0MHz
                                                   810                          1909.8MHz

 The field strength of spurious emissions was measured at each position of all three axis X, Y and Z to
 compare the level, and the maximum noise.
 The worst emission was found in Z axis and the worst case recorded.




TÜV SÜD Zacta Ltd.                                                                    Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                    FCC ID: JOYKC-01


                                                             Page 7 of 26




3. Configuration of equipment
3.1 Equipment(s) used

No.          Equipment               Company             Model No.             Serial No.           FCC ID / DoC           Comment
 1        Mobile Phone              KYOCERA             KC-01                N/A                   JOYKC-01               EUT


3.2 System configuration


     1. Mobile Phone
        (EUT)




Note1: Numbers assigned to equipment or cables on this diagram correspond to the list in “3.1 Equipment(s) used”.




TÜV SÜD Zacta Ltd.                                                                                                  Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                                  FCC ID: JOYKC-01


                                                               Page 8 of 26




4. Conducted Output Power
4.1 Measurement procedure
 [FCC 2.1046]

  The conducted output power was measured with a wireless communication tester connected to the antenna
  terminal. The wireless communication tester parameters were set to produce the maximum power from the
  EUT.


  - Test configuration



                                                                                                          Wireless
                       EUT                                                                                Communication
                                                   Coaxial cable
                                                                                                          Tester




4.2 Measurement result

Date                          :   Sep. 2, 2014
Temperature                   :   23.0 [˚C]
Humidity                      :   54.0 [%]                                Test engineer     :
Test place                    :   Shielded room No.4                                              Chiaki Kanno


                                                              Maximum Burst-Averaged Output Power [dBm]

                                                         GPRS/EDGE(GMSK)Data                        EDGE(8-PSK)Data
                        Frequency      Voice
 Band      Channel                               GPRS      GPRS         GPRS     GPRS     EDGE      EDGE      EDGE        EDGE
                             [MHz]     GSM
                                                 1 TX       2 TX         3 TX     4 TX     1 TX      2 TX     3 TX         4 TX
                                      CS 1slot
                                                 Slot       Slot         Slot     Slot     Slot      Slot      Slot         Slot

              512            1850.2    30.04     30.03     29.87         28.21   27.04     N/A       N/A       N/A          N/A
 GSM
              661            1880.0    29.95     29.94     29.82         28.29   27.01     N/A       N/A       N/A          N/A
  1900
              810            1909.8    29.73     29.71     29.64         28.05   26.81     N/A       N/A       N/A          N/A




TÜV SÜD Zacta Ltd.                                                                                             Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                             FCC ID: JOYKC-01


                                                   Page 9 of 26




5. Equivalent Isotropic Radiated Power

5.1 Measurement procedure
 [FCC 24.232(c)]

<Step 1>
 The EUT and support equipment are placed on a 1 meter x 1.5 meter surface, 0.8 meter height FRP table.
 Radiated emission measurements are performed at 3 meter distance with the broadband antenna (double
 ridged guide antenna). The antenna is positioned both the horizontal and vertical planes of polarization and
 height is varied 1 to 4 meters and stopped at height producing the maximum emission.
 The bandwidth of the spectrum analyzer is set to 1MHz. The turntable is rotated by 360 degrees and
 stopped at azimuth of producing the maximum emission.

<Step 2>
 The substitution antenna is replaced by the transmitter antenna (EUT).
 The frequency of the signal generator is adjusted to the measurement frequency.
 Level of the signal generator is adjusted to the level that is obtained from step 1, and record the emission
 level of signal generator.


  - Test configuration




5.2 Calculation method

Result (EIRP) = S.G Reading – Cable loss + Antenna Gain
Margin = Limit – Result (EIRP)



5.3 Limit

 2 W (33dBm)




TÜV SÜD Zacta Ltd.                                                                         Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                         FCC ID: JOYKC-01


                                                                  Page 10 of 26




5.4 Test data

Date                         :     Oct. 10, 2014                              Test personnel
Temperature                  :o    22.3 [C]
Humidity                     i0    51.2 [%]                                   Tested by              :
Test place                   :     3m Semi—anechoic chamber                                                Taiki Watanabe



[GSM1900]
   3          Frequency           S.A Reading   $.G Reading   Cable loss          AntGain       Result        Limit           Margin
                [MHz]               [dBm]         [dBm]          [dB]              [dBi]        [dBm]         [dBm]             [dB]
                    1850.2               188           21.0             1.1                82        281          330                  4.9
                    1880.0               18.9          22.7             1.1                84        299          330                  3.1
                    1909.8               18.1          221              1.1                85        295          330                  35




TUV SUD Zacta Ltd                                                                                                       Report number: 21010—14087
Test Report RevFCC—2421.0                                                                                                      FCC ID: JOYKC—01


                                                          Page 11 of 26




6. Peak to Average Ratio
6.1 Measurement procedure
 [FCC 24.232(d)]

  The peak to average ratio was measured with a spectrum analyzer connected to the antenna terminal.

  The spectrum analyzer is set to;
   - RBW=1MHz, VBW=3MHz, Span=5MHz, Sweep=auto, Detector=Peak/average, Trace mode=Max hold



  - Test configuration


                                                                      Power splitter
       Spectrum                                                                                           Wireless
       Analyzer                     Attenuator                                                            Communication
                                                      Coaxial cable                    Coaxial cable
                                                                                                          Tester



                                                                          EUT



6.2 Limit

  13dB or less


6.3 Measurement result

Date                         :   Oct. 9, 2014
Temperature                  :   26.6 [˚C]
Humidity                     :   45.6 [%]                             Test engineer        :
Test place                   :   Shielded room No.4                                             Taiki Watanabe



                                                 Frequency                Peak to Average Power Ratio                 Limit
         Mode                    Channel
                                                   [MHz]                              [dB]                             [dB]
      GSM1900                      661             1880                                0.01                             13




TÜV SÜD Zacta Ltd.                                                                                          Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                          FCC ID: JOYKC-01


                                Page 12 of 26




6.4 Trace data
 [GSM1900]

                 Channel: 661




TÜV SÜD Zacta Ltd.                              Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                              FCC ID: JOYKC-01


                                                           Page 13 of 26




7. Occupied Bandwidth
7.1 Measurement procedure
 [FCC 24.238(a), 2.1049]

  The Occupied bandwidth was measured with a spectrum analyzer connected to the antenna terminal.

  The spectrum analyzer is set to;
   - RBW=3kHz, VBW=9.1kHz, Span=1MHz, Sweep=auto, Detector=Peak, Trace mode=Max hold



  - Test configuration


                                                                      Power splitter
       Spectrum                                                                                           Wireless
       Analyzer                     Attenuator                                                            Communication
                                                      Coaxial cable                    Coaxial cable
                                                                                                          Tester



                                                                           EUT




7.2 Limit

  None


7.3 Measurement result

Date                         :   Oct. 9, 2014
Temperature                  :   26.6 [˚C]
Humidity                     :   45.6 [%]                             Test engineer        :
Test place                   :   Shielded room No.4                                             Taiki Watanabe


                                                 Frequency             Test Result
              Band                  Channel
                                                   (MHz)                  (kHz)
                                      512         1850.2                   245.0233
           GSM1900                    661          1880                    245.2772
                                      810         1909.8                   242.0378




TÜV SÜD Zacta Ltd.                                                                                          Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                          FCC ID: JOYKC-01


                                Page 14 of 26




7.4 Trace data
 [GSM1900]
           Channel: 512




                 Channel: 661




                 Channel: 810




TÜV SÜD Zacta Ltd.                              Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                              FCC ID: JOYKC-01


                                                          Page 15 of 26




8. Band Edge Spurious and Harmonic at Antenna Terminals
8.1 Measurement procedure
 [FCC 24.238(a), 2.1051]

  The band edge spurious and harmonic was measured with a spectrum analyzer connected to the antenna
  terminal.

  The spectrum analyzer is set to;
  <Band Edge>
   - RBW=3kHz, VBW=9.1kHz, Span=1MHz, Sweep=auto, Detector=Peak, Trace mode=Max hold

  <Spurious Emissions>
   - RBW=1MHz, VBW=3MHz, Span=Arbitrary setting, Sweep=auto, Detector=Peak, Trace mode=Max hold


  - Test configuration


                                                                      Power splitter
       Spectrum                                                                                                  Wireless
       Analyzer                     Attenuator                                                                   Communication
                                                      Coaxial cable                    Coaxial cable
                                                                                                                 Tester



                                                                          EUT



8.2 Limit

 -13dBm or less


8.3 Measurement result

Date                         :   Oct. 9, 2014
Temperature                  :   26.6 [˚C]
Humidity                     :   45.6 [%]                             Test engineer        :
Test place                   :   Shielded room No.4                                              Taiki Watanabe


                                                 Frequency                   Limit
        Band                     Channel                                                               Results                Results
                                                   [MHz]                     [dB]
                                   512             1850.2                     -13              See the trace data              PASS
    GSM1900
                                   810             1909.8                     -13              See the trace data              PASS




TÜV SÜD Zacta Ltd.                                                                                                Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                                FCC ID: JOYKC-01


                                Page 16 of 26




8.4 Trace data
 [GSM1900]
 (Band Edge)
           Channel: 512




                 Channel: 810




TÜV SÜD Zacta Ltd.                              Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                              FCC ID: JOYKC-01


                             Page 17 of 26




 (Spurious Emissions)
Channel: 512
30MHz-5GHz                           5GHz-10GHz




10GHz-15GHz                          15GHz-20GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                 FCC ID: JOYKC-01


                             Page 18 of 26




Channel: 661
30MHz-5GHz                           5GHz-10GHz




10GHz-15GHz                          15GHz-20GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                 FCC ID: JOYKC-01


                             Page 19 of 26




Channel: 810
30MHz-5GHz                           5GHz-10GHz




10GHz-15GHz                          15GHz-20GHz




TÜV SÜD Zacta Ltd.                                 Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                 FCC ID: JOYKC-01


                                                    Page 20 of 26




9. Radiated Emissions and Harmonic Emissions

9.1 Measurement procedure
 [FCC 24.238(a), 2.1053]

<Step 1>
 The EUT and support equipment are placed on a 1 meter x 1.5 meter surface, 0.8 meter height FRP table.
 Radiated emission measurements are performed at 3 meter distance with the broadband antenna (Biconical
 antenna, Log periodic antenna and double ridged guide antenna). The antenna is positioned both the
 horizontal and vertical planes of polarization and height is varied 1 to 4 meters and stopped at height
 producing the maximum emission.
 The bandwidth of the spectrum analyzer is set to 1MHz. The turntable is rotated by 360 degrees and
 stopped at azimuth of producing the maximum emission. The frequency is investigated up to 20GHz.

<Step 2>
 The substitution antenna is replaced by the transmitter antenna (EUT).
 The frequency of the signal generator is adjusted to the measurement frequency.
 Level of the signal generator is adjusted to the level that is obtained from step 1, and record the emission
 level of signal generator.


  - Test configuration




9.2 Calculation method

 Result = S.G Reading – Cable loss + Antenna Gain
 Margin = Limit – Result (EIRP)



9.3 Limit

 -13dBm or less




TÜV SÜD Zacta Ltd.                                                                         Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                         FCC ID: JOYKC-01


                                                                   Page 21 of 26




9.4 Test data

Date                          :     Oct.2, 2014                                Test personnel
Temperature                   :o    24.3 [C]
Humidity                      :     47.0 [%]                                   Tested by                :
Test place                    :     3m Semi—anechoic chamber                                                   Taiki Watanabe

Date                          :     Oct10,2014                                 Test personnel
Temperature                   :o    22.3 [C]
Humidity                      i0    51.2 [%]                                   Tested by                :
Test place                    :     3m Semi—anechoic chamber                                                   Taiki Watanabe



[GSM1900]
(Channel: 512)
   Ey         Frequency            S.A Reading   $.G Reading   Cable loss          AntGain         Result         Limit            Margin
                [MHz]                [dBm]         [dBm]          [dB]              [dBi]          [dBm]          [dBm]             [dB]
    H               5551.0               64.2          —61.4             20                 11.1       522            130                   3902
                    5551.0               —58.6         19.6              20                 11.1       ~40.4          130                   274
    V               12950.0              64.6          42.1              3.1                133        31.9           130                   189


(Channel: 661)
   3          Frequency            S.A Reading   $.G Reading   Cable loss          AntGain         Result         Limit            Margin
                [MHz]                [dBm]         [dBm]          [dB]              [dBi]          [dBm]          [dBm]             [dB]
    H               5640.0               620           —54.1             20                 114        4417           130                   31.7
                    5640.0               —58.7         18.9              20                 114        305            130                   265
    V               13160.0              64.1          40.5              31                 130        306            130                   176

(Channel: 810)
   3          Frequency            S.A Reading   $.G Reading   Cable loss          AntGain         Result         Limit            Margin
                [MHz]                [dBm]         [dBm]          [dB]              [dBi]          [dBm]          [dBm]             [dB]
    V               5729.0               —61.1         535               20                 16         138            130                   30.8




TUV SUD Zacta Ltd                                                                                                           Report number: 21010—14087
Test Report RevFCC—2421.0                                                                                                          FCC ID: JOYKC—01


                                              Page 22 of 26




10. Frequency Stability
10.1 Measurement procedure
 [FCC 24.235, 2.1055]

 The EUT was placed of an inside of an constant temperature chamber as the temperature in the chamber
 was varied between -30˚C and +50˚C. The temperature was incremented by 10˚C intervals and the unit was
 allowed to stabilize at each measurement. The frequency drift was measured with the normal Temperature
 and voltage tolerance and it is presented as the ppm unit.


  - Test configuration


                                                          Power splitter
       Spectrum                                                                            Wireless
       Analyzer              Attenuator                                                    Communication
                                          Coaxial cable                    Coaxial cable
                                                                                           Tester



                                                              EUT




                                               Constant Temperature Chamber




10.2 Limit

  ±2.5ppm




TÜV SÜD Zacta Ltd.                                                                          Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                          FCC ID: JOYKC-01


                                                             Page 23 of 26




10.3 Measurement result

Date                         :   Oct. 8, 2014
Temperature                  :   25.9 [˚C]
Humidity                     :   33.8 [%]                               Test engineer      :
Test place                   :   Shielded room No.4                                            Taiki Watanabe


[GSM1900]
(Channel: 661)

                                                   Limit: ±0.00025% = ±2.5ppm
   Power Supply              Temperature    Measurements Frequency Frequency Tolerance                  Limit
                                                                                                                           Result
           [V]                     [ºC]               [Hz]                         [ppm]               [ppm]
                                 25(Ref.)        1,880,000,053                    0.00000               ±2.5               PASS
                                   50            1,880,000,059                    0.00336               ±2.5               PASS
                                   40            1,880,000,057                    0.00194               ±2.5               PASS
                                   30            1,880,000,059                    0.00309               ±2.5               PASS
                                   20            1,880,000,062                    0.00467               ±2.5               PASS
          3.80
                                   10            1,880,000,060                    0.00395               ±2.5               PASS
                                    0            1,880,000,054                    0.00076               ±2.5               PASS
                                   -10           1,880,000,059                    0.00297               ±2.5               PASS
                                   -20           1,880,000,056                    0.00153               ±2.5               PASS
                                   -30           1,880,000,058                    0.00264               ±2.5               PASS
          3.230                    25            1,880,000,062                    0.00472               ±2.5               PASS
          4.370                    25            1,880,000,060                    0.00378               ±2.5               PASS



Calculation;
Frequency Tolerance (ppm) = Measurements Frequency (Hz) – Reference Frequency (Hz) / Reference Frequency (Hz) x 1000000




TÜV SÜD Zacta Ltd.                                                                                              Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                              FCC ID: JOYKC-01


                                             Page 24 of 26




11. Uncertainty of measurement
Expanded uncertainties stated are calculated with a coverage Factor k=2.
Please note that these results are not taken into account when determining compliance or non-compliance
with test result.

                               Test item                                   Measurement uncertainty

Conducted emission at mains port                                                     ±3.0dB

Radiated emission (9kHz – 30MHz)                                                     ±4.4dB

Radiated emission (30MHz – 1000MHz)                                                  ±4.5dB

Radiated emission (1000MHz – 26GHz)                                                  ±3.9dB




TÜV SÜD Zacta Ltd.                                                                    Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                    FCC ID: JOYKC-01


                                                         Page 25 of 26




12. Laboratory description
1. Location:
   TÜV SÜD Zacta Ltd. Yonezawa Testing Center
   4149-7 Hachimanpara 5-chome Yonezawa-shi Yamagata 992-1128 Japan
   Phone: +81-238-28-2880 Fax: +81-238-28-2888


2. Facility filing information:
 1) NVLAP accreditation: NVLAP Lab. code: 200306-0

 2) VLAC accreditation: Lab. code: VLAC-013
                                                          Conducted                Conducted          Radiated
                                  Radiated
               Site name                                 emission for              emission for       emission              Expiry Date
                                  emission
                                                          mains port              telecom port         (CMAD)
  3m Semi-anechoic chamber                                                                                -
10m Semi-anechoic chamber No.1                             VLAC-013
                                                                                                      VLAC-013              Jul. 3, 2015
10m Semi-anechoic chamber No.2
      Shielded room No.1                 -                               VLAC-013                            -

 3) FCC filing:
          Site name                               Registration Number                                      Expiry Date
             Site 3                                      91065                                             Oct.31, 2014
   3m Semi-anechoic chamber
10m Semi-anechoic chamber No.1
                                                        540072                                             Feb. 20, 2017
10m Semi-anechoic chamber No.2
      Shielded room No.1

 4) Industry Canada Oats site filing:
          Site name                          Sites on file: Oats 3m/10m                                    Expiry Date
             Site 3                                   4224A-3
   3m Semi-anechoic chamber                           4224A-4                                              Jan. 23, 2015
10m Semi-anechoic chamber No.1                        4224A-5
10m Semi-anechoic chamber No.2                        4224A-6                                              Jan. 15, 2017

 5) VCCI site filing:
                                                                   Conducted                   Conducted
                                        Radiated
               Site name                                          emission for                emission for               Expiry Date
                                        emission
                                                                   mains port                 telecom port
                                                                                                                      Nov. 16, 2014
                   Site 3                R-138                           C-134                    T-1222              Nov. 28, 2014*
                                                                                                                     (*:Telecom port)
  3m Semi-anechoic chamber
10m Semi-anechoic chamber No.1                                           A-0166
                                                                                                                          Jul. 3, 2015
10m Semi-anechoic chamber No.2
      Shielded room No.1                      -                                      A-0166

 6) TÜV SÜD PS authorization:
     Authorized as an EMC test laboratory

 7) TÜV Rheinland authorization:
     Authorized as an EMC test laboratory




TÜV SÜD Zacta Ltd.                                                                                                 Report number: Z101C-14087
Test Report Rev.FCC-24E1.0                                                                                                 FCC ID: JOYKC-01


                                                             Page 26 of 26




Appendix A. Test equipment
Antenna port conducted test
      Equipment                      Company              Model No.               Serial No.       Cal. due            Cal. date
Spectrum analyzer             Agilent Technologies   E4440A                  US44302655          May 31, 2015         May 30, 2014
Microwave cable               RS                     YH_1385                 N/A (8403)          May 31, 2015         May 10, 2014
Aftenuator                    Weinschel              56—10                   J4180               Nov. 30, 2014        Nov. 12, 2013
Microwave cable               SUHNER                 SUCOFLEX104!1.5m        1991214             Oct. 31, 2014         Oct. 7, 2013
Microwave cable               SUHNER                 SUCOFLEX104!1.5m        32208614            Jul. 31, 2015        Jul. 30, 2014
Power splitter                ANRITSU                K240B                   020205              Mar. 31, 2015        Mar. 17, 2014
neperoe    (aoo
 requency tester
                              roHpesscHwarz          cmwso0                  messs               Mar. 31, 2015         Mar.7, 2014
Operation type
temperature                   Espec                  PL1KP                   14007261            Dec. 31, 2014        Dec. 27, 2013
controlled bath



Radiated emission
      Equipment                   Company                 Model No.               Serial No.       Cal. Due             Cal. Date
EMI Receiver                ROHDE&SCHAARZ            ECSI                    100451              Nov. 30, 2014        Nov. 16, 2013
Preamplifier                ANRITSU                  MH648A                  M96O57              Jun. 30, 2015        Jun. 12, 2014
Biconical antenna           Schwarzbeck              VHAO103/BBA2106         2125                May 31, 2015          May 7, 2014
Log periodic antenna        Schwarzbeck              UHALP9108A              0560                May 31, 2015         May 7, 2014
Attenuator                  TME                      CFA—O1NPJ—6             N/A (§275)          Jun. 30, 2015        Jun. 9, 2014
Attenuator                  TME                      CFA—01NPJ—3             N/A (§272)          Jun. 30, 2015        Jun. 9, 2014
Spectrum analyzer           Agilent Technologies     E4440A                  US44302655          May 31, 2015         May 30, 2014
Preamplifier                Agilent Technologies     8449B                   3008A1008           Dec. 31, 2014        Dec. 9, 2013
Dipole antenna              Schwarzbeck              VHAP                    1021                Sep. 30, 2015        Sep. 5, 2014
Dipole antenna              Schwarzbeck              UHAP                    993                 Sep. 30, 2015        Sep. 5, 2014
DoubleHaged guide           Eyog                     3115                    5205                Dec. 31, 2014        Dec. 10, 2013
Aftenuator                  Agilent Technologies     84918                   MY39268633          Jan. 31, 2015        Jan. 15, 2014

DoubleHaged guide           Eyog                     115                     4328                Jan. 31, 2015        Jan. 21. 2014
Signal generator            ROHDE&SCHWARZ            SMB100A                 177525              Feb. 28, 2015        Feb. 18, 2014
Microwave cable             SUHNER                   SUCOFELX1022m           3164812             Feb. 28, 2015        Feb. 13, 2014
High passfiter              Micro—Tronics            HPMSO1M15               004                 Jul. 31, 2015        Jul. 12, 2014
High passfiter              Wainwright               WHIK@.818G—6SS          1                   Jul. 31, 2015        Jul. 17, 2014
Wideband radio
frequency tester
                            ROHDESSCHAARZ            cmwsoo                  messs               Mar. 31, 2015         Mar.7, 2014
                                                     SUCOFLEX1049m           34631614            Oct.   31, 2014       Oct.   6, 2013
Microwave cable             SUHNER                   SUCOFLEX104/1m          32208414            Oct.   31, 2014       Oct.   6, 2013
                                                     SUCOFLEX1041.5m         31722614            Oct.   31, 2014       Oct.   6, 2013
                                                     SUCOFLEX104/7m          4162576             Oct.   31, 2014       Oct.   6, 2013
PC                          DELL                     DIMENSION E521          75465BX                    N/A                   N/A
Software                    TOYO Corporation         EPS/RE—AJ               0611193/5.3.61             N/A                   N/A
3m Sembanechoic
chamber
                            TOKIN                    N/A                     N/A (©002—N8A)      May 31, 2015          May 6, 2014
3m Sembanechoic
chamber
                            TOKIN                    N/A                     N/A (©002—SVSWR)    May 31,2015           May 6, 2014
* The calibrations of the above equipment are traceable to NIST or equivalent standards of the reference organizations.




TUV SUD Zacta Ltd                                                                                             Report number: 21010—14087
Test Report RevFCC—2421.0                                                                                            FCC ID: JOYKC—01



Document Created: 2019-11-08 22:18:52
Document Modified: 2019-11-08 22:18:52

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC