Test Report Part 1

FCC ID: JOYKB46

Test Report

Download: PDF
FCCID_4373758

                                       TEST REPORT
                                                                         DT&C Co., Ltd.
        m Dt &‘                                42, Yurim—ro, 154Beon—gil, Cheoin—gu, Yongin—si, Gyeonggi—do, Korea, 17042
                                                                 Tel : 031—321—2664, Fax : 031—321—1664




   1. Report No :      DRTFCC1907—0212

   2. Customer

        * Name : Kyocera Corporation

        * Address : 2—1—1 Kagahara, Tsuzuki, Yokohama—shi, Kanagawa, Japan 224—8502

   3. Use of Report : FCC Original Grant

  4. Product Name / Model Name : Mobile Phone / KB46
     FCC ID : JOYKB46

  5. Test Method Used : KDB905462 DO2v02 , KDB905462 DO3v01r02
     Test Specification : FCC Part 15.407

  6. Date of Test : 2019.06.20

  7. Testing Environment : See appended test report.

  8. Test Result : Refer to the attached test result.




    d           Tested by                                             Reviewed by
  Affirmation                                        7                                                   l ?w'
                Name : JaeHyeok Bang                 w Name : GeunKi Son                                     F
  The test results presented in this test report are limited only to the sample supplied by applicant and
  the use of this test report is inhibited other than its purpose. This test report shall not be reproduced except
  in full, without the written approval of DT&C Co., Ltd.




                                                    2019 . 07 . 22 .


                                              DT&C Co., Ltd.

             If this report is required to confirmation of authenticity, please contact to report@dtnc.net




TRF—RF—228(04)170516          Prohibits the copying and re—issue of this report without DT&C approval.           Pages: 1/ 15


                                    Report No.: DRTFCC1907-0212                                   FCC ID: JOYKB46




                            Test Report Version


   Test Report No.               Date                                            Description

  DRTFCC1907-0212           Jul. 22, 2019           Initial issue




TRF-RF-228(04)170516   Prohibits the copying and re-issue of this report without DT&C approval.     Pages: 2 / 15


                                            Report No.: DRTFCC1907-0212                                    FCC ID: JOYKB46




                                       Table of Contents

        1. GENERAL INFORMATIONEUT DESCRIPTION ........................ 4
          1.1. EUT Description .................................................................... 4
          1.2. Auxiliary equipment ............................................................... 4
          1.3. Testing environment .............................................................. 4
        2. DYNAMIC FREQUENCY SELECTION TEST DESCRIPTION ... 5
          2.1. Applicability of DFS requirements prior to use of a channel ... 5
          2.2. Applicability of DFS requirements during normal operation ... 5
          2.3. Requirements of client devices .............................................. 6
          2.4. DFS response requirement values ........................................ 7
          2.5. DFS detection thresholds ...................................................... 7
          2.6. Radar test waveforms ........................................................... 8
        3. Test procedure .......................................................................... 9
          3.1. Setup for Client with injection at the Master ........................... 9
          3.2. Spectrum analyzer setting parameter .................................... 9
          3.3. Conducted test procedure ..................................................... 9
        4. SUMMARY OF TESTS ............................................................. 10
        5. LIST OF EQUIPMENTS ............................................................11
        6. TEST RESULTS ....................................................................... 12
          6.1. Move time and aggregate time ............................................ 12
            6.1.1. U-NII-2A: 5310 MHz ......................................................................... 12
            6.1.2. U-NII-2C: 5510 MHz ......................................................................... 12
          6.2. Non-occupancy period ........................................................ 13
            6.2.1. U-NII-2A: 5310 MHz ......................................................................... 13
            6.2.2. U-NII-2C: 5510 MHz ......................................................................... 13
        APPENDIX I ................................................................................. 14



TRF-RF-228(04)170516           Prohibits the copying and re-issue of this report without DT&C approval.       Pages: 3 / 15


                                             Report No.: DRTFCC1907-0212                                            FCC ID: JOYKB46




1. GENERAL INFORMATIONEUT DESCRIPTION
 1.1. EUT Description

  FCC equipment class          Unlicensed National Information Infrastructure (UNII)

  Product                      Mobile Phone

  Model name                   KB46

  Add model name               NA

  EUT capabilities             DFS

  Power supply                 DC 3.8V

  Test condition                    Conducted                                          Radiated

  Channel bandwidth            802.11a/n/ac: 20 MHz                802.11n/ac: 40 MHz                      802.11ac: 80 MHz

                               U-NII 2A(5250 ~ 5350 MHz)                          U-NII 2C(5470 ~ 5725 MHz)

                                ▪ 802.11a/n(HT20)/ac(VHT20):                       ▪ 802.11a/n(HT20)/ac(VHT20):
  Frequency Range                5260 ~ 5320 MHz                                   5500 ~ 5700 MHz
                                ▪ 802.11n(HT40)/ac(VHT40):                         ▪ 802.11n(HT40)/ac(VHT40):
                                 5270 ~ 5310 MHz                                   5510 ~ 5670 MHz
                                ▪ 802.11ac(VHT80):                                 ▪ 802.11ac(VHT80):
                                  5290 MHz                                         5530 ~ 5610 MHz

  Modulation type              OFDM

                                    Master mode
  Operational mode                  Client mode without radar detection
                                    Client mode with radar detection

                               Antenna type: Internal Antenna

  Antenna specification                                     U-NII-2A              +0.9 dBi
                               Antenna gain
                                                            U-NII-2C              +1.2 dBi
 Note1: The above EUT information was declared by the manufacturer.

 1.2. Auxiliary equipment

          Equipment              Model No.                Serial No.             Manufacturer                       Note

      Access Point (Master)       DIR-868L             R3X81E6000093                   D-Link              FCC ID: RRK2012060056-1


1.3. Testing environment

   Ambient Condition

     ▪ Temperature                  +25 ℃
     ▪ Relative Humidity            35 %




    TRF-RF-228(04)170516        Prohibits the copying and re-issue of this report without DT&C approval.              Pages: 4 / 15


                                             Report No.: DRTFCC1907-0212                                             FCC ID: JOYKB46




2. DYNAMIC FREQUENCY SELECTION TEST DESCRIPTION
2.1. Applicability of DFS requirements prior to use of a channel
                                                                             Operational mode
               Requirement                                                   Client without                Client with radar
                                                       Master
                                                                           radar detection                    detection
    Non-Occupancy Period                                  Yes                 Not required                        Yes
    DFS Detection Threshold                               Yes                 Not required                        Yes
    Channel Availability Check time                       Yes                 Not required                    Not required

    U-NII Detection Bandwidth                             Yes                 Not required                        Yes



2.2. Applicability of DFS requirements during normal operation
                                                                                 Operational mode
                   Requirement                            Master or client with                   Client without radar
                                                              radar detection                               detection
    DFS Detection Threshold                                            Yes                                 Not required

    Channel Closing Transmission Time                                  Yes                                     Yes
    Channel Move time                                                  Yes                                     Yes
    U-NII Detection Bandwidth                                          Yes                                 Not required




  TRF-RF-228(04)170516          Prohibits the copying and re-issue of this report without DT&C approval.                Pages: 5 / 15


                                               Report No.: DRTFCC1907-0212                                            FCC ID: JOYKB46




                                                                                   Operational mode
     Additional requirements for devices
                                                            Master or client with                   Client without radar
        with multiple bandwidth modes
                                                                radar detection                              detection
    U-NII Detection Bandwidth and Statistical                All BW modes must be
                                                                                                             Not required
    Performance Check                                                   tested

    Channel Move Time and Channel Closing
                                                          Test using widest BW mode               Test using the widest BW
    Transmission Time                                              available                      mode available for the link

    All other tests                                           Any single BW mode                             Not required


    Note: Frequencies selected for statistical performance check (Section 7.8.4) should include several frequencies within
         the radar detection bandwidth and frequencies near the edge of the radar detection bandwidth. For 802.11
         devices it is suggested to select frequencies in each of the bonded 20 MHz channels and the channel center
         frequency.


  The EUT was tested according to the following specification:
   905462 D02 UNII DFS Compliance Procedure New Rules v02
   905462 D03 UNII Client Without Radar Detection New Rules v01r02

2.3. Requirements of client devices
  a) A Client Device will not transmit before having received appropriate control signals from a Master Device.
  b) A Client Device will stop all its transmissions whenever instructed by a Master Device to which it is associated and
    will meet the Channel Move Time and Channel Closing Transmission Time requirements. The Client Device will
    not resume any transmissions until it has again received control signals from a Master Device.
  c) If a Client Device is performing In-Service Monitoring and detects a Radar Waveform above the DFS Detection
    Threshold, it will inform the Master Device. This is equivalent to the Master Device detecting the Radar Waveform
    and d) through f) of section 5.1.1 apply.
  d) Irrespective of Client Device or Master Device detection the Channel Move Time and Channel Closing
    Transmission Time requirements remain the same.
  e) The client test frequency must be monitored to ensure no transmission of any type has occurred for 30 minutes.
    Note: If the client moves with the master, the device is considered compliant if nothing appears in the client non-
    occupancy period test. For devices that shut down (rather than moving channels), no beacons should appear.




  TRF-RF-228(04)170516            Prohibits the copying and re-issue of this report without DT&C approval.               Pages: 6 / 15


                                                  Report No.: DRTFCC1907-0212                                              FCC ID: JOYKB46



 2.4. DFS response requirement values
     Parameter                                                 Value
     Non-occupancy period                                      Minimum 30 minutes

     Channel availability check time                           60 seconds

                                                               10 seconds
     Channel move time
                                                               See Note 1.

                                                               200 milliseconds + an aggregate of 60 milliseconds over
     Channel closing transmission time
                                                               remaining 10 second period. See Notes 1 and 2.
     Note 1: Channel Move Time and the Channel Closing Transmission Time should be performed with Radar Type 0. The
             measurement timing begins at the end of the Radar Type 0 burst.
     Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning of the
             Channel Move Time plus any additional intermittent control signals required to facilitate a Channel move (an
             aggregate of 60 milliseconds) during the remainder of the 10 second period. The aggregate duration of control
             signals will not count quiet periods in between transmissions.



2.5. DFS detection thresholds
   Below provides the DFS Detection Thresholds for Master Devices as well as Client Devices incorporating
   In-Service Monitoring.

                                                                                                 Value
     Maximum Transmit Power
                                                                                                 (See Notes 1, 2, and 3)

     EIRP ≥ 200 milliwatt                                                                        -64 dBm

     EIRP < 200 milliwatt and
                                                                                                 -62 dBm
     power spectral density < 10 dBm/MHz

     EIRP < 200 milliwatt that do not meet the power spectral density
                                                                                                 -64 dBm
     requirement
     Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
     Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test transmission
              waveforms to account for variations in measurement equipment. This will ensure that the test signal is at or
              above the detection threshold level to trigger a DFS response.
     Note3: EIRP is based on the highest antenna gain. For MIMO devices refer to KDB Publication 662911 D01.




    TRF-RF-228(04)170516             Prohibits the copying and re-issue of this report without DT&C approval.                Pages: 7 / 15


                                                 Report No.: DRTFCC1907-0212                                          FCC ID: JOYKB46



2.6. Radar test waveforms


                                                                                                         Minimum         Minimum
              Pulse
 Radar                                 PRI                                                            percentage of       number
              width                                               Number of pulses
  type                               (μsec)                                                             successful            of
              (μsec)
                                                                                                         detection          trials
    0            1                    1428                                    18                         See Note 1      See Note 1

                             Test A: 15 unique PRI
                           values randomly selected                     1      19 ∙ 106
                                                             Roundup {(    )∙(          )}
                             from the list of 23 PRI                   360     𝑃𝑅𝐼𝜇𝑠𝑒𝑐
                            values in section 2.6.2.

                             Test B: 15 unique PRI
    1            1         values randomly selected                                                            60%            30
                            within the range of 518-
                               3066 μsec, with a
                           minimum increment of 1
                              μsec, excluding PRI
                           values selected in Test A

    2           1-5                 150-230                                 23-29                              60%            30

    3          6-10                 200-500                                 16-18                              60%            30

    4          11-20                200-500                                 12-16                              60%            30

 Aggregate (Radar Types 1-4)                                                                                   80%           120
 Note 1: As the EUT is a Client Device without Radar Detection, only one type of radar pulse is required for testing.
         The Radar Pulse type 0 was used to evaluate the Client device to measure the Channel Move Time
         and the Channel Closing Transmission Time.
 Note 2: This report was applied Short Pulse Radar Type 0.




   TRF-RF-228(04)170516             Prohibits the copying and re-issue of this report without DT&C approval.            Pages: 8 / 15


                                              Report No.: DRTFCC1907-0212                                   FCC ID: JOYKB46



3. Test procedure
 3.1. Setup for Client with injection at the Master
  The setup method is shown below diagram. The method according to the 905462 D02 UNII DFS Compliance
  Procedure New Rules v02 - section 7.2




 3.2. Spectrum analyzer setting parameter
  The setting parameter is shown below and it according to the 905462 D02 UNII DFS Compliance Procedure New
  Rules v02 - section 7.5
     1)   RBW /VBW ≥ 3MHz
     2)   Detector = Peak
     3)   Span = zero span
     4)   Sweep time ≥ 12s


 3.3. Conducted test procedure
   1) One frequency will be chosen from the Operating Channels of the UUT within the 5250-5350 MHz or 5470-5725
       MHz bands.
   2) The Client Device (EUT) is set up the above diagram and communications between the Master device and the
       Client is established.
   3) Stream the channel loading test file from the Master Device to the Client Device on the test Channel for the entire
       period of the test. (The MPEG file specified by the FCC (“6 ½ Magic Hours”))
   4) An additional 1 dB is added to the radar test signal to ensure it is at or above the DFS Detection Threshold,
       accounting for equipment variations/errors.
   5) Observe the transmissions of the UUT at the end of the Burst on the Operating Channel for duration greater than
       12 seconds for Radar Type 0 to ensure detection occurs.
   6) After the initial radar burst the channel is monitored for 30 minutes to ensure no transmissions or beacons occur.
       A second monitoring setup is used to verify that the Master and Client have both moved to different channels.




    TRF-RF-228(04)170516         Prohibits the copying and re-issue of this report without DT&C approval.     Pages: 9 / 15


                                               Report No.: DRTFCC1907-0212                                    FCC ID: JOYKB46



4. SUMMARY OF TESTS

      Parameter                                               Limit                                         Status
                                                                                                             Note 1

                                                                                                               C
      Channel move time                                       10 seconds                                     Note 2



                                                              200ms + aggregate of 60ms over                   C
      Channel closing transmission time                                                                     Note 2, 3
                                                              remaining 10 second period


      Non-occupancy period                                    30 minutes                                       C




       Note 1: C=Comply      NC=Not Comply       NT=Not Tested        NA=Not Applicable

       Note 2: Channel Move Time and the Channel Closing Transmission Time should be performed with Radar Type
               0. The measurement timing begins at the end of the Radar Type 0 burst.

       Note 3: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning of the
                Channel Move Time plus any additional intermittent control signals required to facilitate a Channel move
                (an aggregate of 60 milliseconds) during the remainder of the 10 second period. The aggregate duration
                of control signals will not count quiet periods in between transmissions.




  TRF-RF-228(04)170516           Prohibits the copying and re-issue of this report without DT&C approval.          Pages: 10 / 15


                                                  Report No.: DRTFCC1907-0212                                          FCC ID: JOYKB46



5. LIST OF EQUIPMENTS
                                                                             Cal.Date          Next.Cal.Date
          Type               Manufacturer                 Model            (yy/mm/dd)           (yy/mm/dd)
                                                                                                                           S/N
 Spectrum Analyzer        Agilent Technologies      N9020A                   18/12/19             19/12/19     MY50410357
                                                                             18/07/02             19/07/02
 DC Power Supply          Agilent Technologies      66332A                                                     MY43000211
                                                                             19/06/25             20/06/25
 Multimeter               FLUKE                     17B                      18/12/18             19/12/18     26030065WS
                                                                             18/07/06             19/07/06
 DFS Bridge System        DTNC                      DFS-01                                                     T001
                                                                             19/07/02             20/07/02
 Signal Generator         Rohde Schwarz             SMBV100A                 18/12/19             19/12/19     255571

 Thermohygrometer         BODYCOM                   BJ5478                   18/12/27             19/12/27     120612-1
                                                                             18/07/04             19/07/04
 PXIS-2670(G)             ADLINK                    3025C                                                      302581/834
                                                                             19/06/25             20/06/25
                                                                             18/07/04             19/07/04
 PXIS-2670(G)             ADLINK                    3035C                                                      303581/927
                                                                             19/06/25             20/06/25
 Cable                    Infinet                   CABLE                    18/12/24             19/12/24     RF-39

 Cable                    Infinet                   CABLE                    18/12/24             19/12/24     RF-40

 Cable                    Infinet                   CABLE                    18/12/24             19/12/24     RF-42

 Cable                    Infinet                   CABLE                    18/12/24             19/12/24     RF-51

 Cable                    Infinet                   CABLE                    18/12/24             19/12/24     RF-52

 Note: The cable is not a regular calibration item, so it has been calibrated by DT & C itself.




   TRF-RF-228(04)170516             Prohibits the copying and re-issue of this report without DT&C approval.              Pages: 11 / 15


                                           Report No.: DRTFCC1907-0212                                  FCC ID: JOYKB46



6. TEST RESULTS
6.1. Move time and aggregate time
 6.1.1. U-NII-2A: 5310 MHz




 6.1.2. U-NII-2C: 5510 MHz




  TRF-RF-228(04)170516       Prohibits the copying and re-issue of this report without DT&C approval.    Pages: 12 / 15


                                           Report No.: DRTFCC1907-0212                                  FCC ID: JOYKB46



6.2. Non-occupancy period
 6.2.1. U-NII-2A: 5310 MHz




 6.2.2. U-NII-2C: 5510 MHz




  TRF-RF-228(04)170516       Prohibits the copying and re-issue of this report without DT&C approval.    Pages: 13 / 15


                                             Report No.: DRTFCC1907-0212                                  FCC ID: JOYKB46



APPENDIX I

Channel loading

U-NII-2A: 5310 MHz
               Timing plots: A minimum channel loading of approximately 17% or greater




   - Spectrum Analyzer setting
     1) Span: Zero
     2) Sweep points: 40001

    Calculation:
     Channel loading = (Channel loading sweep points / Total sweep points) x 100
                     = (23102 / 40001) x 100 = 57.75 %
     Note: The Channel loading sweep points were extracted from the spectrum and calculated.




   TRF-RF-228(04)170516        Prohibits the copying and re-issue of this report without DT&C approval.    Pages: 14 / 15


                                             Report No.: DRTFCC1907-0212                                  FCC ID: JOYKB46



Channel loading

U-NII-2C: 802.11ac(VHT40), 5510 MHz
                Timing plots: A minimum channel loading of approximately 17% or greater




   - Spectrum Analyzer setting
     1) Span: Zero
     2) Sweep points: 40001

    Calculation:
     Channel loading = (Channel loading sweep points / Total sweep points) x 100
                     = (23463 / 40001) x 100 = 58.66 %
     Note: The Channel loading sweep points were extracted from the spectrum and calculated.




   TRF-RF-228(04)170516        Prohibits the copying and re-issue of this report without DT&C approval.    Pages: 15 / 15



Document Created: 2019-07-22 16:10:36
Document Modified: 2019-07-22 16:10:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC