KA73_SAR Test Report_2_rev

FCC ID: JOYKA73

RF Exposure Info

Download: PDF
FCCID_2882233

                                                                                  Page 60 of 95




Attachment 1. Probe calibration data




                     &      s                                                        «ts                                                       k
               Cahbratlon Laboratory of                                            S\\\\\\\_-///II/'}                           S   Schweizerischer Kalibrierdienst
               Schmid & Partner                                                   m                                             . Service suisse d‘étalonnage
                  Engineering AG                                                  Ts                                            g Servizio svizzero di taratura
               Zeughausstrasse 43, 8004 Zurich, Switzerland                        4,,"/fi\“?                                        Swiss Calibration Service
                                                                                       Th ul


               Accredited by the Swiss Accreditation Service (SAS)                                                              Accreditation No.: SCS 0108
               The Swiss Accreditation Service is one of the signatories to the EA
               Multilateral Agreementfor the recognition of calibration certificates

               Client       Vitec                                                                                  Certificate No: EX3—3745_Apr15

               CALIBRATION CERTIFICATE                                                          ,                           '                                                     |
                Object                                EX3DV4 — SN:3745


                Calibration procedure(s)              QA CAL—01.v9, QA CAL—12.v9, QA CAL—14.v4, QA CAL—23.v5,
                                                      QA CAL—25.v6
                                                      Calibration procedure for dosimetric E—field probes

                Calibration date:                     April 24, 2015

                This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
                The measurements and the uncertainties with confidence probability are given on the following pages and are part of thecertificate.


                All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


                Calibration Equipment used (M&TE critical for calibration)



                Primary Standards                    ID                                 Cal Date (Certificate No.)                     Scheduled Calibration
                Power meter E44198                   GB41293874                         01—Apr—15 (No. 217—02128)                      Mar—16
                Power sensor E4412A                  MY41498087                         01—Apr—15 (No. 217—02128)                      Mar—16
                Reference 3 dB Aftenuator            SN: $5054 (3c)                     01—Apr—15 (No. 217—02129)                      Mar—16
                Reference 20 dB Aftenuator           SN: S5277 (20%)                    01—Apr—15 (No. 217—02132)                      Mar—16
                Reference 30 dB Aftenuator           SN: $5129 (30b)                    01—Apr—15 (No. 217—02133)                      Mar—16
                Reference Probe ES3DV2               SN: 3013                           30—Dec—14 (No. ES3—3013_Dec14)                 Dec—15
                DAE4                                 SN: 660                            14—Jan—15 (No. DAE4—660_Jan15)                Jan—16


                Secondary Standards                  ID                                 Check Date (in house)                         Scheduled Check
                RF generator HP 8648C                US3642U01700                       4—Aug—99 (in house check Apr—13)               In house check: Apr—16
                Network Analyzer HP 8753E            US37390585                         18—Oct—01 (in house check Oct—14)              In house check: Oct—15

                                                          Name                                      Function                                 Signature
                Calibrated by:                         Jeton Kastrati                               Laboratory Technician            Sebs

                                                                                                                                        \|
                Approved by:                           Katia Pokovic                                Technical Manager               %/ /é :/_



                                                                                                                                             Issued: April 25, 2015
                This calibration certificate shall not be reproduced except in full without written approval of the laboratory.




               Certificate No: EX3—3745_Apr15                                        Page 1 of 11




TUV SUD Zacta Ltd.                                                                                                                                                    Report number: 2101C—15138
Test Report Rev.SARFCC1.0                                                                                                                                                       FCC ID: JOYKA73


                                                                             Page 61 of 95




                                                                                 w99
                 Calibration Laboratory of                                   C
                                                                             sy//z                         S   Schweizerischer Kalibrierdienst
                 Schmid & Partner                                           Sk\\—'é:'
                                                                                   |Ef_                    c   Service suisse d‘étalonnage
                     Engineering AG                                          i rrmsg                       g   Servizio svizzero di taratura
                Zeughausstrasse 43, 8004 Zurich, Switzerland                  */:fi\\“\“                        Swiss Calibration Service



                 Accredited by the Swiss Accreditation Service (SAS)                                        Accreditation No.: SCS 0108
                 The Swiss Accreditation Service is one of the signatories to the EA
                 Multilateral Agreementfor the recognition of calibration certificates

                Glossary:
                TSL                           tissue simulating liquid
                NORMx,y,z                     sensitivity in free space
                ConvF                         sensitivity in TSL / NORMx,y,z
                DCP                           diode compression point
                CF                            crest factor (1/duty_cycle) of the RF signal
                A, B,C, D                     modulation dependentlinearization parameters
                Polarization q                @ rotation around probe axis
                Polarization 8                8 rotation around an axis that is in the plane normal to probe axis (at measurement center),
                                              .e., 8 = 0 is normal to probe axis
                Connector Angle               information used in DASY system to align probe sensor X to the robot coordinate system

                Calibration is Performed According to the Following Standards:
                      a)   IEEE Std 1528—2013, "IEEE Recommended Practice for Determining the Peak Spatial—Averaged Specific
                           Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement
                           Techniques", June 2013
                      b)   IEC 62209—1, "Procedure to measure the Specific Absorption Rate (SAR) for hand—held devices used in close
                           proximity to the ear (frequency range of 300 MHz to 3 GHz)", February 2005

                Methods Applied and Interpretation of Parameters:
                      *    NORMx,y,z: Assessed for E—field polarization 8 = 0 (f < 900 MHz in TEM—cell; f > 1800 MHz: R22 waveguide).
                           NORMx,y,z are only intermediate values, i.e., the uncertainties of NORMx,y,z does not affect the E*—field
                           uncertainty inside TSL (see below ConvF).
                      *    NORM(Mx,y,z = NORMx,y,z * frequency_response (see Frequency Response Chart). This linearization is
                           implemented in DASY4 software versions later than 4.2. The uncertainty of the frequency response is included
                           in the stated uncertainty of ConvF.
                      e    DCPx,y,z: DCP are numerical linearization parameters assessed based on the data of power sweep with CW
                           signal (no uncertainty required). DCP does not depend on frequency nor media.
                      e    PAR: PAR is the Peak to Average Ratio thatis not calibrated but determined based on the signal
                           characteristics
                      e    Axy.z Bxy.z; Cxy,z; Dxy,z; VRx,y,z: A, B, C, D are numerical linearization parameters assessed based on
                           the data of power sweep for specific modulation signal. The parameters do not depend on frequency nor
                           media. VR is the maximum calibration range expressed in RMS voltage across the diode.
                      *    ConvF and Boundary Effect Parameters: Assessed in flat phantom using E—field (or Temperature Transfer
                           Standard for f < 800 MHz) and inside waveguide using analytical field distributions based on power
                           measurements for f > 800 MHz. The same setups are used for assessment of the parameters applied for
                           boundary compensation (alpha, depth) of which typical uncertainty values are given. These parameters are
                           used in DASY4 software to improve probe accuracy close to the boundary. The sensitivity in TSL corresponds
                           to NORMx,y,z * ConvF whereby the uncertainty corresponds to that given for ConvF. A frequency dependent
                           ConvF is used in DASY version 4.4 and higher which allows extending the validity from + 50 MHz to + 100
                           MHz.
                     *     Spherical isotropy (3D deviation from isotropy): in a field of low gradients realized using a flat phantom
                           exposed by a patch antenna.
                      e    Sensor Offset: The sensor offset corresponds to the offset of virtual measurement center from the probe tip
                           (on probe axis). No tolerance required.
                     *     Connector Angle: The angle is assessed using the information gained by determining the NORMx (no
                           uncertainty required).


                Certificate No: EX3—3745_Apr15                                 Page 2 of 11




TUV SUD Zacta Ltd.                                                                                                                   Report number: 2101C—15138
Test Report Rev.SARFCC1.0
                                                                                                                                               FCC ID: JOYKA73


                                                                 Page 62 of 95




                 EXSDV4 — SN:3745                                                                 April 24, 2015




                                        Probe EX3DV4

                                                           SN:3745

                                                   Manufactured:                 March 26, 2010
                                                   Calibrated:                   April 24, 2015



                                                  Calibrated for DASY/EASY Systems
                                                     (Note: non—compatible with DASY2 system!)




                 Certificate No: EX3—3745_Apr15                    Page 3 of 11




TUV SUD Zacta Ltd.                                                                                    Re           :      —
Test Report Rev.SAR—FCC1.0                                                                              eport number:
                                                                                                                 FCC £1010—19138
                                                                                                                      ID: JOYKA73


                                                                                Page 63 of 95




                EX3DV4— SN:3745                                                                                                                   April 24, 2015



                DASY/EASY — Parameters of Probe: EX3DV4 — SN:3745

                Basic Calibration Parameters
                                                                Sensor X                         Sensor Y                    Sensor Z              Unc (k=2)
                 Norm (uV/(V/m)")"                                 0.48                           0.44                          0.49               £10.1 %
                 DCP (mV)"                                         99.5                           103.2                        100.8


                Modulation Calibration Parameters
                 UID           Communication System Name                                    A             B          c           D         VR          Unc"
                                                                                           dB        dByuV                      dB         mV          (k=2)
                 0             Cw                                                 x        0.0           0.0        1.0        0.00       158.6       23.3 %
                                                                                  Y        0.0           0.0        1.0                   170.6
                                                                                  FA       0.0           0.0        1.0                   157.4



                 The reported uncertainty of measurement is stated as the standard uncertainty of measurement
                 multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
                 probability of approximately 95%.


                * The uncertainties of NormX,Y,Z do not affect the E*—field uncertainty inside TSL (see Pages 5 and 6).
                ® Numerical linearization parameter: uncertainty not required.
                © Uncertainty is determined using the max. deviation from linear response applying rectangular distribution and is expressed for the square of the
                field value.




               Certificate No: EX3—3745_Apr15                                      Page 4 of 11




TUV SUD Zacta Ltd.                                                                                                                                     Report number: 2101C—15138
Test Report Rev.SARFCC1.0                                                                                                                                        FCC
                                                                                                                                                          °        c ID: JOYKA73


                                                                                Page 64 of 95




                EX3DV4— SN:3745                                                                                                                April 24, 2015




                 DASY/EASY — Parameters of Probe: EX3DV4 — SN:3745


                Calibration Parameter Determined in Head Tissue Simulating Media
                                       Relative          Conductivity                                                               Depth °          Unct.
                      f(MHz)*        Permittivity"          (S/m)"           ConvFX        ConvFY        ConvFZ        Aipha®        _(mm)           (k=2)

                         300              45.3                0.87            10.60          10.60         10.60         0.10         1.10        £13.3%
                         450              43.5                0.87             9.43             9.43       9.43          0.15         1.20        £13.3%
                         650              42.5                0.89             9.48             9.48       9.48          9:3          1.20        £13.3%
                         750              41.9                0.89             9.13             9.13       9.13          0.42         0.90        £12.0 %
                         835              41.5                0.90             8.78             8.78       8.78          0.31         1.03        £12.0 %
                         900              41.5                0.97             8.61             8.61       8.61          0.33         1.00        £12.0%
                        1450              40.5                1.20             7.A7             7.A7       7.A7          0.20         1.18        £#12.0 %
                        1640              40.3                1.29             7.55             7.55       7.55          0.34         0.80        £12.0 %
                        1750              40.1                187              7.50             7.50       7.50          0.42         0.80        £12.0 %
                        1810              40.0                140              782              7.32       732           0.32         0.93        £12.0 %
                        1900              40.0                140              7.29             7.29       7.29          0.37         0.80        £12.0 %
                        1950              40.0                1.40             7.08             7.08       7.08          0.30         0.90        £12.0 %
                        2450              39.2                1.80             6.64             6.64       6.64          0.35         0.86        +12.0 %
                        2600              39.0                1.96             6.49             6.49       6.49          0.39         0.88        £*12.0 %
                        5200              36.0                4.66             4.16          4.76          4.76          0.35         1.80        £13.1 %
                       5250               35.9                4.71             4.73          4.73          4.73          0.35         1.80        £13.1%
                       5300               35.9                4.76             4.66          4.66          4.66          0.35         1.80        131 %
                       5500               35.6                4.96            4.43           4.43          4.43          0.40         1.80        £13.1%
                       5600               35.5                5.07            4.25           4.25          4.25          0.40         1.80        £13.1%
                       5750               35.4                5.22            4.45           4.45          4.45          0.40         1.80        £13.1%
                       5800               35.3                5.27            4.28           4.28          4.28          0.40         1.80        £13.1%
                © Frequency validity above 300 MHz of + 100 MHz only applies for DASY v4.4 and higher (see Page 2), else it is restricted to + 50 MHz. The
                uncertainty is the RSS of the ConvF uncertainty at calibration frequency and the uncertainty for the indicated frequency band. Frequency validity
                below 300 MHz is + 10, 25, 40, 50 and 70 MHz for ConvF assessments at 30, 64, 128, 150 and 220 MHz respectively. Above 5 GHz frequency
                validity can be extended to + 110 MHz.
                " At frequencies below 3 GHz, the validity of tissue parameters (e and a) can be relaxed to + 10% i liquid compensation formula is applied to
                measured SAR values. At frequencies above 3 GHz, thevalidity of tissue parameters (s and a) is restricted to + 5%. The uncertainty is the RSS of
                the ConvF uncertainty for indicated target tissue parameters.
                © Alpha/Depth are determined during calibration. SPEAG warrants thatthe remaining deviation due to the boundary effect after compensation is
                always less than + 1% for frequencies below 3 GHz and below + 2% for frequencies between 3—6 GHz at any distance larger than half the probe tip
                diameter from the boundary.




                Certificate No: EX3—3745_Apr15                                   Page 5 of 11




TUV SUD Zacta Ltd .                                                                                                                                  Report number: Z101C—15138
Test Report Rev.SAR—FCC1.0                                                                                                                              °      Fgc ID: JOYKAT3


                                                                                Page 65 of 95




                EX3DV4— SN:3745                                                                                                                April 24, 2015




                DASY/EASY — Parameters of Probe: EX3DV4 — SN:3745

                Calibration Parameter Determined in Body Tissue Simulating Media
                                        Relative         Conductivity                                                               Depth °          Unct.
                      f(MHz)°        Permittivity"           (S/m)"          ConvFX        ConvFY¥       ConvFZ        Aipha®        _(mm)           (k=2)

                         300              58.2                0.92            10.10             10.10      10.10         0.08         110         *13.3 %

                        450               56.7                0.94            10.02             10.02      10.02         0.10         1.20        13.3 %

                         650              55.9                0.96             9.48             9.48       9.48          0.10         1.20        13.3 %

                         750              55.5                0.96             8.86             8.86       8.86          0.47         0.80        £12.0 %

                         835              55.2                0.97             8.81             8.81       8.81          0.33         1.03        £*12.0 %

                         900              55.0                1.05             8.55             8.55       8.55          0.35         1.06        * 12.0 %

                        1450              54.0                1.30             7.46             7.46       7.46          0.22         1.25        +12.0 %

                        1640              53.8                140              7.61             7.61       7.61          0.43         0.80        £12.0 %

                        1750              53.4                149              7.23             723        7.23          0.38         0.80        £12.0 %

                        1810              53.3                1.52             7.08             7.08       7.08          0.45         0.81        £*12.0 %

                        1900              §3.3                1.62             6.99             6.99       6.99          0.39         0.80        +12.0 %

                        1950              53.3                1.52             7.A7             7.A7       ZA7           0.39         0.84        £12.0 %

                        2450              §2.7                1.95             6.73             6.73       6.73          0.37         0.80        £12.0 %

                       2600               52.5                2.16             6.45             6.45       6.45          0.27         0.99        £*12.0 %

                       5200               49.0                5.30             4.28             4.28       4.28          0.40         1.90        #13.1 %

                       5250               48.9                5.36             4.29             4.29       4.29          0.40         1.90        £13.1 %

                       5300               48.9                5.42            4.19              4.19       4.19          0.40         1.90        #13.1 %

                       5500               48.6                5.65             3.86             3.86       3.86          0.45         1.90        £413.1 %
                       5600               48.5                5.77             $.76             3.75       3.75          0.45         1.90        £13.1 %

                       5750               48.3                5.94             3.93             5.93       3.903         0.50        1.90         #13.1 %

                       5800               48.2                6.00            3.84              3.84       3.84          0.50        1.90         £13.1 %
                © Frequency validity above 300 MHz of + 100 MHz only applies for DASY v4.4 and higher (see Page 2), else it is restricted to + 50 MHz. The
                uncertainty is the RSS of the ConvF uncertainty at calibration frequency and the uncertainty for theindicated frequency band. Frequency validity
                below 300 MHz is + 10, 25, 40, 50 and 70 MHz for ConvF assessments at 30, 64, 128, 150 and 220 MHz respectively. Above 5 GHz frequency
                validity can be extended to + 110 MHz.
                " At frequencies below 3 GHz, thevalidity of tissue parameters (e and a) can berelaxed to + 10% if liquid compensation formula is applied to
                measured SAR values. At frequencies above 3 GHz, the validity of tissue parameters (s and a) is restricted to + 5%. The uncertainty is the RSS of
                the ConvF uncertainty for indicated target tissue parameters.
                © Alpha/Depth are determined during calibration. SPEAG warrants that the remaining deviation due to the boundary effect after compensation is
                always less than + 1% for frequencies below 3 GHz and below * 2% for frequencies between 3—6 GHz at any distance larger than half the probe tip
                diameterfrom the boundary.




                Certificate No: EX3—3745_Apr15                                   Page 6 of 11




TUV SUD Zacta Ltd.                                                                                                                                   Report number: Z101C—15138
Test Report Rev.SAR—FCC1.0                                                                                                                                     FCC ID: JOYKAT73


                                                                                              Page 66 of 95




                 EXSDV4— SN:3745                                                                                                      April 24, 2015


                                                                          Frequency Response of E—Field
                                                                               (TEM—Cell:ifi110 EXX, Waveguide: R22)
                                                                § TTTT
                                                              s#
                                                                n
                            Frequency response (normalized)


                                                              TTr—acen
                                                                 —
                                                                 T
                                                                  1
                                                              3
                                                                   |




                                                                         Uncertainty of Frequency Response of E—field: £ 6.3% (k=2)




                 Certificate No: EX3—3745_Apr15                                                 Page 7 of 11




TUV SUD Zacta Ltd.
Test Report Rev.SARFCC1.0                                                                                                                  Report number: Z101C—15138
                                                                                                                                                       FCC ID: JOYKA73


                                                                                                 Page 67 of 95




                 EXSDV4— SN:3745                                                                                                                                                   April 24, 2015




                                                                 Receiving Pattern (¢), 8 = 0°

                                                  f=600 MHz,TEM                                                                              f=1800 MHz,R22




                               1”‘          /              *            o4    08       08    ’0                      mo,\              7             giel *’_:02, o«    op ‘os       }]
                                        1              +                270        ]         }                          1         1]            *            x                1
                                        i                        4       [         £                                        t     4             P        K                    io




                                s                      99—                                  £                          a                        *                                  1
                               Tot                     x                Y                    7                        Tot                       xX               Y                   £




                             DG —jreececerce c


                        3
                        'g 00
                        £
                        ul

                             —0.57

                                     ||||||ir||\||||i|v||514|;15|11|x
                                                ~150             ~100                  50                    0                             50                                150
                                                                                                          Roll [*]                                                     0_
                                                       :                                    :l                                         * |                             ®
                                                  100 MHz                          600 MHz                                      1800 MHz                             2500   MHz


                                                               Uncertainty of Axial Isotropy Assessment: £ 0.5% (k=2)




                 Certificate No: EX3—3745_Apr15                                                   Page 8 of 11




TUV SUD Zacta Ltd.
Test Report Rev.SARFCC1.0                                                                                                                                                                 Report
                                                                                                                                                                                           eport number: : 2101C—15138
                                                                                                                                                                                                                —
                                                                                                                                                                                                    FCC ID: JOYKA73


                                                                       Page 68 of 95




                 EXSDV4— SN:3745                                                                                         April 24, 2015




                                                      Dynamic Range f(SARpeaq)
                                                                (TEM cell , fevai= 1900 MHz)


                                         108




                                         105




                                    3. 10
                                    C
                                    &
                                    2
                                    &
                                    §
                                    o.
                                    £€ 10+



                                         102




                                               108        102        101         10          10‘         10         10
                                                                            SAR [mW/cm3]
                                                                 *
                                                         not compensated                     compensated




                                         t
                                         &
                                         5
                                         i


                                               103        102        101          100      101      102       103
                                                                           SAR [mW/cm3]
                                                                L*
                                                         not compensated                   compensated


                                                     Uncertainty of Linearity Assessment: £ 0.6% (k=2)




                Certificate No: EX3—3745_Apr15                             Page 9 of 11




TUV SUD Zacta Ltd.
Test Report Rev.SAR—FCC1.0                                                                                                     spor hoiFCC
                                                                                                                                        hn 2ID:(onodee
                                                                                                                              Report number:      —1513
                                                                                                                                                JOYKAT73


                                                                                                  Page 69 of 95                                                                                       ‘



                                                                                                                                                                                                           Zacta




                 EXSDV4— SN:3745                                                                                                                                               April 24, 2015

                                                            Conversion Factor Assessment
                                     f= 900 MHz,WGLS R9 (H_convF)                                                       f= 1810 MHz,WGLS R22 (H_convF)
                             40-!                                                                                             prammean       —     fetegeneAemmenaeareemer ns



                             35 [



                             3 OP\

                             25}                                                                                        X.4
                         §";~                                                                                            3x
                         §. 20
                         &

                         *\ sef                                                                                                                                                       |
                             10
                                E                     x                                                                                 xx
                                                            \                                                                                     ns
                                 |                               *~.                                                                                   Rg:
                             o‘sl                                          tss x                                                                               *       .l


                                      10              20      & [3"1‘)""     40              5o          co               8       10         15    & l:lm]     25      30      35    40

                                             ce                                     fea)                                          x                                   a
                                           anabscal                               measured                                      anabical                            measured



                                                           Deviation from Isotropy in Liquid
                                                                                     Error (6, 8), f = 900 MHz




                                                  —1.0        —0.8         —0.6      —0.4         —0.2        00   02     0.4          0.6        08         1.0
                                                           Uncertainty of Spherical Isotropy Assessment: £ 2.6% (k=2)




                Certificate No: EX3—3745_Apr15                                                      Page 10 of 11




TUV SUD Zacta Ltd.                                                                                                                                                                  Report number: Z101C—15138
Test Report Rev.SAR—FCC1.0                                                                                                                                                                      FCC ID: JOYKA73


                                                               Page 70 of 95




                 EX3DV4— SN:3745                                                  April 24, 2015




                 DASY/EASY — Parameters of Probe: EX3DV4 — SN:3745

                Other Probe Parameters
                     Sensor Arrangement                                            Triangular
                     Connector Angle (°)                                                 60.8
                     Mechanical Surface Detection Mode                               enabled
                     Optical Surface Detection Mode                                  disabled
                     Probe Overall Length                                            337 mm
                     Probe Body Diameter                                               10 mm
                     Tip Length                                                         9 mm
                     Tip Diameter                                                     2.5 mm
                     Probe Tip to Sensor X Calibration Point                            1 mm
                     Probe Tip to Sensor Y Calibration Point                            1 mm
                     Probe Tip to Sensor Z Calibration Point                            1 mm
                     Recommended Measurement Distance from Surface                    14 mm




                Certificate No: EX3—3745_Apr15                    Page 11 of 11




TUV SUD Zacta Ltd.                                                                     Report number: 2101C—15138
Test Report Rev.SAR—FCC1.0                                                                         FCC ID: JOYKA73