SAR Report part 3

FCC ID: JOYJA32

RF Exposure Info

Download: PDF
FCCID_4145835

              SGS-CSTC Standards Technical Services Co., Ltd.
              Shenzhen Branch
                                      Report No.: HR/2018/9000501




              Appendix B
             Detailed Test Results
1. GSM
GSM850 for Head & Body
GSM1900 for Head & Body
2. WCDMA
WCDMA Band V for Head & Body
3.LTE
LTE Band 17 for Head & Body
4.WIFI
WIFI 2.4G for Head & Body
WIFI 5G for Head & Body
5.BT
BT for Head


                                                                             Date: 2018—10—26

Test Laboratory: SGS—SAR Lab

Kyocera JA32 GSM850 190CH Right cheek

DUT: JA32; Type: Smart Phone; Serial: 99370616

Communication System: UID 0, GSM Only Communication System (0), Frequency: 836.6
MHz;Duty Cycle: 1:8.30042

Medium: HSL835;Medium parameters used: £= 837 MHz; 0 = 0.917 S/m; &, = 43.195; p = 1000
kg/m*
Phantom section: Right Section

DASY 5 Configuration:

   *« Probe: EX3DV4 — SN3789; ConvF(8.66, 8.66, 8.66), Calibrated: 2018—02—08;
   * Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
     Electronics: DAE4 $n1267; Calibrated: 2017—11—28
     Phantom: SAM2; Type: SAM; Serial: 1913
     DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (8x13x1): Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (measured) = 0.738 W/kg

Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 13.91 V/m; Power Drift=—0.13 dB
Peak SAR (extrapolated) = 0.848 W/kg
SAR(I g)=0.662 W/kg; SAR(10 g)= 0.504 W/kg
Maximum value of SAR (measured) = 0.758 W/kg




   —2.10



   —4.20



   —6.29



   —8.39



   —10.49
            0 dB = 0.758 W/kg =—1.20 dBW/kg


                                                                              Date: 2018—10—30

Test Laboratory: SGS—SAR Lab

Kyocera JA32 GSMS850 GSM 190CH Front side 13mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, GSM Only Communication System (0), Frequency: 836.6
MHz;Duty Cycle: 1:8.30042

Medium: MSL835;Medium parameters used: £= 837 MHz; 0 = 1.013 S/m; &, = 57.423; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

    *« Probe: EX3DV4 — SN3962; ConvF(9.98, 9.98, 9.98); Calibrated: 2018—01—11;
    * Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: SAM 1; Type: SAM; Serial: 1912
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (7x13x1): Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (measured) = 0.372 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 16.83 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.409 W/kg
SAR(I g)= 0.333 W/kg; SAR(10 g)=0.263 W/kg
Maximum value of SAR (measured) = 0.377 W/kg




   1.47



   —2.93



   —4.40



   —5.86



   —1.33
              0 dB = 0.377 W/kg = —4.24 dBW/kg


                                                                              Date: 2018—10—30

Test Laboratory: SGS—SAR Lab

Kyocera JA32 GSMS850 GPRS 2TS 190CH Back side 10mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, GPRS/EGPRS Mode(2up) Communication System (0), Frequency:
836.6 MHz;Duty Cyole: 1:4.14954

Medium: MSL835;Medium parameters used: £= 837 MHz; 0 = 1.013 S/m; &, = 57.423; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

    *« Probe: EX3DV4 — SN3962; ConvF(9.98, 9.98, 9.98); Calibrated: 2018—01—11;
    * Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: SAM 1; Type: SAM; Serial: 1912
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (7x13x1): Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (measured) = 0.480 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 17.80 V/m; Power Drift =—0.02 dB
Peak SAR (extrapolated) = 0.669 W/kg
SAR(I g)=0.412 W/kg; SAR(10 g)=0.253 W/kg
Maximum value of SAR (measured) = 0.540 W/kg




   —2.64



   —5.29



   —1.93



   —10.58



   —13.22
              0 dB = 0.540 W/kg = —2.68 dBW/kg


                                                                             Date: 2018—10—27

Test Laboratory: SGS—SAR Lab

Kyocera JA32 GSM1900 GSM 661CH Left cheek

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, GSM Only Communication System (0), Frequency: 1880
MHz;Duty Cycle: 1:8.30042

Medium: HSL1900;Medium parameters used: £= 1880 MHz; 5 = 1.383 S/m; &, = 40.732; p = 1000
kg/m*
Phantom section: Left Section

DASY 5 Configuration:

   *« Probe: EX3DV4 — SN3962; ConvF(8.26, 8.26, 8.26), Calibrated: 2018—01—11;
   * Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: SAM 1; Type: SAM; Serial: 1912
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (8x13x1): Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (measured) = 0.256 W/kg

Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 4.691 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.354 W/kg
SAR(I g)=0.235 W/kg; SAR(10 g)=0.145 W/kg
Maximum value of SAR (measured) = 0.299 W/kg




   —3.37



   —6.74



   10.12



   13.49



   —16.86
              0 dB = 0.299 W/kg = —5.24 dBW/kg


                                                                              Date: 2018—10—26

Test Laboratory: SGS—SAR Lab

Kyocera JA32 GSM1900 661CH Front side 15mm

DUT: JA32; Type: Smart Phone; Serial: 99370616

Communication System: UID 0, GSM Only Communication System (0), Frequency: 1880
MHz;Duty Cycle: 1:8.30042

Medium: MSL1900;Medium parameters used: £= 1880 MHz; 5 = 1.481 S/m; &, = 52.697; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

    *« Probe: EX3DV4 — SN3789; ConvF(7.28, 7.28, 7.28), Calibrated: 2018—02—08;
    * Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 $n1267; Calibrated: 2017—11—28
        Phantom: SAM 1; Type: SAM V4.0; Serial: TP—1283
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (8x13x1): Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (measured)=0.131 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 3.786 V/m; Power Drift =0.01 dB
Peak SAR (extrapolated) =0.178 W/kg
SAR(I g)=0.113 W/kg; SAR(10 g)=0.069 W/kg
Maximum value of SAR (measured) = 0.146 W/kg




   —2.176



   —5.53



   —8.29



   —11.06



   —13.82
              0 dB = 0.146 W/kg =—8.36 dBW/kg


                                                                              Date: 2018—10—26

Test Laboratory: SGS—SAR Lab

Kyocera JA32 GSM1900 GPRS 2TS 661CH Bottom side 10mm

DUT: JA32; Type: Smart Phone; Serial: 99370616

Communication System: UID 0, GPRS/EGPRS Mode(2up) Communication System (0), Frequency:
1880 MHz;Duty Cycle: 1:4.14954

Medium: MSL1900;Medium parameters used: £= 1880 MHz; 5 = 1.481 S/m; &, = 52.697; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

    *« Probe: EX3DV4 — SN3789; ConvF(7.28, 7.28, 7.28), Calibrated: 2018—02—08;
    * Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 $n1267; Calibrated: 2017—11—28
        Phantom: SAM 1; Type: SAM V4.0; Serial: TP—1283
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (5x9x1): Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (measured) = 0.606 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 18.30 V/m; Power Drift =0.01 dB
Peak SAR (extrapolated) =0.952 W/kg
SAR(I g)=0.570 W/kg; SAR(10 g)=0.313 W/kg
Maximum value of SAR (measured) = 0.767 W/kg




   —3.42



   —6.84



   —10.26



   —13.68



   ~17.10
              0 dB = 0.767 W/kg =—1.15 dBW/kg


                                                                             Date: 2018—10—26

Test Laboratory: SGS—SAR Lab

Kyocera JA32 WCDMA Band V 4182CH Right cheek

DUT: JA32; Type: Smart Phone; Serial: 99370616

Communication System: UID 0, WCDMA (0); Frequency: 836.4 MHz;Duty Cycle: 1:1

Medium: HSL835;Medium parameters used: £= 836.4 MHz; 0 = 0.917 S/m; & =43.198; p = 1000
kg/m*
Phantom section: Right Section

DASY 5 Configuration:

      Probe: EX3DV4 — SN3789; ConvF(8.66, 8.66, 8.66); Calibrated: 2018—02—08;
      Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
      Electronics: DAE4 $n1267; Calibrated: 2017—11—28
      Phantom: SAM2; Type: SAM; Serial: 1913
      DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (8x13x1);: Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (measured) =0.581 W/kg

Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 8.993 V/m; Power Drift = 0.16 dB
Peak SAR (extrapolated) =0.695 W/kg
SAR(I g)=0.506 W/kg; SAR(10 g)=0.375 W/kg
Maximum value of SAR (measured) = 0.583 W/kg




   —2.16



   —4.31



   —6.47



   —8.62



   —10.78
            0 dB = 0.583 W/keg = —2.34 dBW/kg


                                                                               Date: 2018—10—30

Test Laboratory: SGS—SAR Lab

Kyocera JA32 WCDMA Band V 4182CH Back side 15mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WCDMA (0); Frequency: 836.4 MHz;Duty Cycle: 1:1

Medium: MSL835;Medium parameters used: £= 836.4 MHz; 0 = 1.013 S/m; & = 57.426; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3962; ConvF(9.98, 9.98, 9.98); Calibrated: 2018—01—11;
        Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: SAM 1; Type: SAM; Serial: 1912
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 mm
Maximum value of SAR (measured) = 0.502 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 20.64 V/m; Power Drift =—0.01 dB
Peak SAR (extrapolated) = 0.550 W/kg
SAR(I g)=0.442 W/kg; SAR(10 g)=0.344 W/kg
Maximum value of SAR (measured) = 0.504 W/kg




   —1.46



   —2.92



   —4.39



   —5.85



   —£.31
              0 dB = 0.504 W/ke =—2.98 dBW/kg


                                                                               Date: 2018—10—30

Test Laboratory: SGS—SAR Lab

Kyocera JA32 WCDMA Band V 4182CH Right side 10mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WCDMA (0); Frequency: 836.4 MHz;Duty Cycle: 1:1

Medium: MSL835;Medium parameters used: £= 836.4 MHz; 0 = 1.013 S/m; & = 57.426; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3962; ConvF(9.98, 9.98, 9.98); Calibrated: 2018—01—11;
        Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: SAM 1; Type: SAM; Serial: 1912
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (3x13x1): Measurement grid: dx=15mm, dy=1 mm
Maximum value of SAR (measured) =0.714 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 24.83 V/m; Power Drift =—0.09 dB
Peak SAR (extrapolated) =0.821 W/kg
SAR(I g)=0.588 W/kg; SAR(10 g)=0.410 W/kg
Maximum value of SAR (measured) = 0.719 W/kg




   —1.82



   —3.65



   —5.47



   —1.30



   —9.12
              0 dB =0.719 W/ke =—1.43 dBW/kg


                                                                            Date: 2018—10—26

Test Laboratory: SGS—SAR Lab

Kyocera JA32 LTE Band 17 QPSK 1RB49 Offset 23790CH Right cheek

DUT: JA32; Type: Smart Phone; Serial: 99370616

Communication System: UID 0, LTE—FDD BW 10MHZ (0); Frequency: 710 MHz;Duty Cycle: 1:1

Medium: HSL750;Medium parameters used: £= 710 MHz; 0 = 0.834 S/m; s, = 44.003; p = 1000
kg/m*
Phantom section: Right Section

DASY 5 Configuration:

     Probe: EX3DV4 — SN3789; ConvF(8.93, 8.93, 8.93); Calibrated: 2018—02—08;
     Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
     Electronics: DAE4 $n1267; Calibrated: 2017—11—28
     Phantom: SAM2; Type: SAM; Serial: 1913
     DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (8x13x1);: Measurement grid: dx=1 5mm, dy=1 5mm
Maximum value of SAR (measured) =0.181 W/kg

Configuration/Head/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 3.992 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.206 W/kg
SAR(I g)=0.163 W/kg; SAR(10 g)=0.127 W/kg
Maximum value of SAR (measured) = 0.185 W/kg




   —1.92



   —3.85



   —5.77



   —7.70



   —9.62
            0 dB =0.185 W/keg =—7.33 dBW/kg


                                                                             Date: 2018—10—29

Test Laboratory: SGS—SAR Lab

Kyocera JA32 LTE Band 17 10M QPSK 1RB49 23790CH Back side 15mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, LTE—FDD BW 10MHZ (0); Frequency: 710 MHz;Duty Cycle: 1:1

Medium: MSL750;Medium parameters used: £= 710 MHz; 0 = 0.926 S/m; s = 57.856; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3962; ConvF(10.37, 10.37, 10.37); Calibrated: 2018—01—11;
    * Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
    * Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: SAM 1; Type: SAM; Serial: 1912
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 mm
Maximum value of SAR (measured) = 0.280 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 16.63 V/m; Power Drift =—0.01 dB
Peak SAR (extrapolated) =0.303 W/kg
SAR(I g)=0.251 W/kg; SAR(10 g)=0.200 W/kg
Maximum value of SAR (measured) = 0.282 W/kg




   —1.34



   —2.68



   —4.02



   —5.36



   —6.70
              0 dB = 0.282 W/ke =—5.50 dBW/kg


                                                                             Date: 2018—10—29

Test Laboratory: SGS—SAR Lab

Kyocera JA32 LTE Band 17 10M QPSK 1RB49 23790CH Back side 10mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, LTE—FDD BW 10MHZ (0); Frequency: 710 MHz;Duty Cycle: 1:1

Medium: MSL750;Medium parameters used: £= 710 MHz; 0 = 0.926 S/m; s = 57.856; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

    * Probe: EX3DV4 — SN3962; ConvF(10.37, 10.37, 10.37); Calibrated: 2018—01—11;
    * Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
    * Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: SAM 1; Type: SAM; Serial: 1912
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=1 mm
Maximum value of SAR (measured) = 0.300 W/kg

Configuration/Body/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 17.10 V/m; Power Drift =—0.00 dB
Peak SAR (extrapolated) =0.325 W/kg
SAR(I g)=0.271 W/kg; SAR(10 g)=0.215 W/kg
Maximum value of SAR (measured) =0.301 W/kg




   —1.53



   —3.06



   —4.60



   —6.13



   —1.66
              0 dB =0.301 W/kg =—5.21 dBW/kg


                                                                               Date: 2018—11—07

Test Laboratory: SGS—SAR Lab

Kyocera JA32 802.11b 11CH Left tilted

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WI—FI(2.4GHz) (0); Frequency: 2462 MHz;Duty Cycle: 1:1

Medium: HSL2450;Medium parameters used: £= 2462 MHz; 0 = 1.814 S/m; & = 40.145; p = 1000
kg/m*
Phantom section: Left Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3789; ConvF(7.01, 7.01, 7.01); Calibrated: 2018—02—08;
        Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 $n1267; Calibrated: 2017—11—28
        Phantom: SAM 1; Type: SAM V4.0; Serial: TP—1283
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (Ox16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.415 W/kg

Configuration/Head/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 6.704 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.863 W/kg
SAR(I g)=0.349 W/kg; SAR(10 g)=0.156 W/kg
Maximum value of SAR (measured) = 0.562 W/kg




   —4.95



   —9.89



   —14.84



   —19.78



   —24.73
              0 dB = 0.562 W/ke = —2.50 dBW/kg


                                                                               Date: 2018—11—06

Test Laboratory: SGS—SAR Lab

Kyocera JA32 802.11b 11CH Front side 13mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WI—FI(2.4GHz) (0); Frequency: 2462 MHz;Duty Cycle: 1:1

Medium: MSL2450;Medium parameters used: £= 2462 MHz; 0 = 1.998 S/m; &, = 50.357; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3789; ConvF(7.15, 7.15, 7.15); Calibrated: 2018—02—08;
        Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 $n1267; Calibrated: 2017—11—28
        Phantom: ELI V5.0; Type: ELI; Serial: 1123
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (Ox16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) =0.0431 W/kg

Configuration/Body/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 2.465 V/m; Power Drift =0.18 dB
Peak SAR (extrapolated) = 0.0570 W/kg
SAR(I g)=0.033 W/kg; SAR(10 g)=0.020 W/kg
Maximum value of SAR (measured) = 0.0452 W/kg




   —3.17



   —6.33



   —9.50



   —12.66



   —15.83
              0 dB = 0.0452 W/kg = —13.45 dBW/kg


                                                                               Date: 2018—11—06

Test Laboratory: SGS—SAR Lab

Kyocera JA32 802.11b 11CH Right side 10mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WI—FI(2.4GHz) (0); Frequency: 2462 MHz;Duty Cycle: 1:1

Medium: MSL2450;Medium parameters used: £= 2462 MHz; 0 = 1.998 S/m; &, = 50.357; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3789; ConvF(7.15, 7.15, 7.15); Calibrated: 2018—02—08;
        Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 $n1267; Calibrated: 2017—11—28
        Phantom: ELI V5.0; Type: ELI; Serial: 1123
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (6x16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) =0.112 W/kg

Configuration/Body/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 6.536 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) =0.143 W/kg
SAR(I g)=0.082 W/kg; SAR(10 g)=0.044 W/kg
Maximum value of SAR (measured) =0.114 W/kg




   —4.32



   —8.64



   —12.97



   —17.29



   —21.61
              0 dB =0.1 14 W/kg =—9.43 dBW/kg


                                                                               Date: 2018—11—06

Test Laboratory: SGS—SAR Lab

Kyocera JA32 802.11a 52CH Left cheek

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WI—FI(5GHz) (0); Frequency: 5260 MHz;Duty Cycle: 1: 1

Medium: HSL5SGHz;Medium parameters used: £= 5260 MHz; 0 =4.765 S/m; & = 36.016; p = 1000
kg/m*
Phantom section: Left Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3962; ConvF(5.68, 5.68, 5.68); Calibrated: 2018—01—11;
        Sensor—Surface: 1.4mm (Mechanical Surface Detection), z = —2.0, 23.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: SAM 2; Type: SAM V4.0; Serial: 1640
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (11x19x1); Measurement grid: dx=10mm, dy=1Omm
Maximum value of SAR (measured) = 1.34 W/kg

Configuration/Head/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 11.89 V/m; Power Drift =0.01 dB
Peak SAR (extrapolated) =3.46 W/kg
SAR(I g)=0.700 W/kg; SAR(10 g)=0.205 W/kg
Maximum value of SAR (measured) = 1.69 W/kg




   —5.25



   —10.50



   —15.74



   —20.99



   —26.24
               0 dB = 1.69 W/kg = 2.28 dBW/kg


                                                                               Date: 2018—11—08

Test Laboratory: SGS—SAR Lab

Kyocera JA32 802.11a 100CH Front side 15mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WI—FI(5GHz) (0); Frequency: 5500 MHz;Duty Cycle: 1: 1

Medium: MSLSGHz;Medium parameters used: £= 5500 MHz; 6 = 5.694 S/m; s, = 47.804; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3962; ConvF(4.45, 4.45, 4.45); Calibrated: 2018—01—11;
        Sensor—Surface: 1.4mm (Mechanical Surface Detection), z = —2.0, 23.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: ELI V5.0; Type: ELI; Serial: 1123
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (11x19x1); Measurement grid: dx=1Omm, dy=10mm
Maximum value of SAR (measured) = 0.0852 W/kg

Configuration/Body/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 0 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 0.109 W/kg
SAR(I g)=0.017 W/kg; SAR(10 g)=0.00415 W/kg
Maximum value of SAR (measured) = 0.0858 W/kg




   —10.00



   —20.00



   —30.00



   —40.00



   —50.00
               0 dB = 0.0858 W/kg = —10.67 dBW/kg


                                                                               Date: 2018—11—08

Test Laboratory: SGS—SAR Lab

Kyocera JA32 802.11a 36CH Back side 10mm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WI—FI(5GHz) (0); Frequency: 5180 MHz;Duty Cycle: 1: 1

Medium: MSL5SGHz;Medium parameters used: £= 5180 MHz; 6 = 5.305 S/m; s =48.521; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3962; ConvF(5.22, 5.22, 5.22); Calibrated: 2018—01—11;
        Sensor—Surface: 1.4mm (Mechanical Surface Detection), z = —2.0, 23.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: ELI V5.0; Type: ELI; Serial: 1123
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (11x19x1); Measurement grid: dx=1Omm, dy=10mm
Maximum value of SAR (measured) = 0.130 W/kg

Configuration/Body/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 1.990 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) =0.419 W/kg
SAR(I g)=0.026 W/kg; SAR(10 g)=0.00903 W/kg
Maximum value of SAR (measured) = 0.138 W/kg




   —10.00



   —20.00



   —30.00



   —40.00



   —50.00
               0 dB = 0.138 W/ke =—8.60 dBW/kg


                                                                               Date: 2018—11—08

Test Laboratory: SGS—SAR Lab

Kyocera JA32 802.11a 100CH Front side Omm

DUT: JA32; Type: Smart Phone; Serial: 99370653

Communication System: UID 0, WI—FI(5GHz) (0); Frequency: 5500 MHz;Duty Cycle: 1: 1

Medium: MSLSGHz;Medium parameters used: £= 5500 MHz; 6 = 5.694 S/m; s, = 47.804; p = 1000
kg/m*
Phantom section: Flat Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3962; ConvF(4.45, 4.45, 4.45); Calibrated: 2018—01—11;
        Sensor—Surface: 1.4mm (Mechanical Surface Detection), z = —2.0, 23.0
        Electronics: DAE4 Sn1428; Calibrated: 2018—01—17
        Phantom: ELI V5.0; Type: ELI; Serial: 1123
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Body/Area Scan (11x19x1); Measurement grid: dx=1Omm, dy=10mm
Maximum value of SAR (measured) =2.82 W/kg

Configuration/Body/Zoom Scan (7x7x12)/Cube 0: Measurement grid: dx=4mm, dy=4mm,
dz=2mm
Reference Value = 0 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 6.85 W/kg
SAR(I g)=1.07 W/kg; SAR(10 g)= 0.303 W/kg
Maximum value of SAR (measured) = 3.26 W/kg




   —10.00



   —20.00



   —30.00



   —40.00



   —50.00
               0 dB =3.26 W/kg = 5.13 dBW/kg


                                                                               Date: 2018—11—07

Test Laboratory: SGS—SAR Lab

Kyocera JA32 BT DHS OCH Left cheek

DUT: JA32; Type: Smart Phone; Serial: 99370616

Communication System: UID 0, Bluetooth (0); Frequency: 2402 MHz;Duty Cycle: 1:1

Medium: HSL2450;Medium parameters used: £ = 2402 MHz; 0 = 1.747 S/m; & = 40.26; p = 1000
kg/m*
Phantom section: Left Section

DASY 5 Configuration:

        Probe: EX3DV4 — SN3789; ConvF(7.01, 7.01, 7.01); Calibrated: 2018—02—08;
        Sensor—Surface: 2mm (Mechanical Surface Detection), z =—2.0, 31.0
        Electronics: DAE4 $n1267; Calibrated: 2017—11—28
        Phantom: SAM 1; Type: SAM V4.0; Serial: TP—1283
        DASY52 52.8.8(1222); SEMCAD X 14.6.10(7331)


Configuration/Head/Area Scan (Ox16x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.127 W/kg

Configuration/Head/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 4.044 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) =0.258 W/kg
SAR(I g)=0.101 W/kg; SAR(10 g)=0.047 W/kg
Maximum value of SAR (measured) = 0.166 W/kg




   —4.89



   —9.77



   —14.66



   —19.54



   —24.43
              0 dB =0.166 W/kg =—7.80 dBW/kg