Test Report NFC

FCC ID: JOYJA32

Test Report

Download: PDF
FCCID_4145753

                                             FCC PART 15C

                                             TEST REPORT
                                                              For


                                   KYOCERA Corporation
                Yokohama Office 2-1-1 Kagahara,Tsuzuki-ku Yokohama-shi,Kanagawa,Japan


                                            Model Number: JA32



            Report Type:                                 Product Name:
            Original Report                              S mart Phone



                 Report Number:           RDG181026006-00E


                      Report Date:        2018-12-15
                                          Jerry Zhang

                     Reviewed By:         EMC Manager

                                          Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:         No.69 Pulongcun, Puxinhu Industry Area,
                                          Tangxia, Dongguan, Guangdong, China
                                          Tel: +86-769-86858888
                                          Fax: +86-769-86858891
                                          www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan).
This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of
the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an
asterisk “*”


  Bay Area Compliance Laboratories Corp. (Dongguan)                                                                       Report No.: RDG181026006-00E




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................5
FCC §15.207– AC LINE CONDUCTED EMISSIONS ..............................................................................................6
  EUT SETUP ..................................................................................................................................................................6
  EMI TEST RECEIVER SETUP .........................................................................................................................................6
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................7
  TEST PROCEDURE ........................................................................................................................................................7
  CORRECTED AMPLITUDE & MARGIN CALCULATION ...................................................................................................7
  TEST RESULTS SUMMARY ............................................................................................................................................8
  TEST DATA ..................................................................................................................................................................8
FCC§15.225, §15.205 & §15.209- RADIATED EMISSIONS ..................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  EUT SETUP ................................................................................................................................................................11
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................12
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................12
  TEST RESULTS SUMMARY ..........................................................................................................................................13
  TEST DATA ................................................................................................................................................................13
FCC§15.225(E) - FREQUENCY STABILITY..........................................................................................................19
  APPLICABLE STANDARD ............................................................................................................................................19
  TEST PROCEDURE ......................................................................................................................................................19
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................19
  TEST DATA ................................................................................................................................................................20
FCC §15.215(C)– 20 DB BANDWIDTH TESTING .................................................................................................21
  APPLICABLE STANDARD ............................................................................................................................................21
  TEST PROCEDURE ......................................................................................................................................................21
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................21
  TEST DATA ................................................................................................................................................................22




                                                                                                                                                            Page 2 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG181026006-00E

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)

                                     EUT Name:       Smart Phone
                                     EUT Model:      JA32
                                          Grant:     JOY
                                         FCC ID:     JOYJA32
                               Hardware Version:     JA32
                                     SW version:     Sdm660_64-userdebug 9
                                  Serial Number:     JA32125479850089K0180
                              EUT Received Date:     2018.10.26


Objective
This type approval report is prepared on behalf of KYOCERA Corporationin accordance with Part 2,
Subpart J, and Part 15, Subparts A and C of the Federal Communications Commission’s rules.

The objective is to determine the compliance of the EUT with FCC rules, sec 15.203, 15.205, 15.207,
15.209, 15.215 and 15.225.


Test Methodology
All measurements detailed in this Test Report were performed in accordance with ANSI C63.10-2013
“American National Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices”.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).
The radiated testing was performed at an antenna-to-EUT distance of 3 meters.




                                                                                             Page 3 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG181026006-00E

Measurement Uncertainty
               Parameter                                Measurement Uncertainty
       Occupied Channel Bandwidth                                  ±5 %
                                                          9kHz~30MHz: 4.12dB
            radiated Emissions             30M~200MHz: 4.58 dB for Horizontal, 4.59 dB for Vertical
                                            200M~1GHz: 4.83 dB for Horizontal, 5.85 dB for Vertical
              Temperature                                          ±1℃
                Humidity                                           ±5%
      DC and low frequency voltages                               ±0.4%
               Duty Cycle                                           1%
       AC Power Lines Conducted                          3.12 dB (150 kHz to 30 MHz)
                Emission



Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. : CN1220.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062D.




                                                                                               Page 4 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)      Report No.: RDG181026006-00E

SYSTEM TEST CONFIGURATION
Justification
The system was configured for testing in a test mode.


EUT Exercise Software
No software used in test.


Block Diagram of Test Setup




                                                                          Page 5 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG181026006-00E

FCC §15.207– AC LINE CONDUCTED EMISSIONS

EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with an AC 120V/60Hz power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                               Page 6 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG181026006-00E

Test Equipment List and Details

                                                                     Serial        Calibration    Calibration
      Manufacturer              Description           Model
                                                                    Number            Date         Due Date
           R&S               EMI Test Receiver      ESCS 30        830245/006      2018-12-10      2019-12-10
         Unknown               Coaxial Cable       C-NJNJ-50        C-0200-01      2018-09-05      2019-09-05
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614        2018-12-10      2019-12-10

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.

According FCC publication number 174176,for a device with a permanent antenna operating at or below
30 MHz, the measurements done with a suitable dummy load, in lieu of the permanent antenna under the
following conditions: (1) perform the AC line conducted tests with the permanent antenna to determine
compliance with the Section 15.207 limits outside the transmitter's fundamental emission band; (2) retest
with a dummy load in lieu of the permanent antenna to determine compliance with the Section 15.207
limits within the transmitter's fundamental emission band.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF

Herein,
VC: corrected voltage amplitude
VR: reading voltage amplitude

Ac: attenuation caused by cable loss

VDF: voltage division factor of AMN or ISN




                                                                                                     Page 7 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG181026006-00E

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:


                                   Margin = Limit – Corrected Amplitude

Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207.


Test Data
    Environmental Conditions

              Temperature:               23.2 C
         Relative Humidity:                35 %
             ATM Pressure:               99.9 kPa

      The testing was performed by Lily Xie on 2018-12-14.

   Test Result: Pass




                                                                                             Page 8 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG181026006-00E

Test mode: Transmitting (NFC)

AC 120V, 60 Hz, Line:


                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60
                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      2.344095                     34.5              9.000         L1       9.8        21.5      56.0          Compliance
      2.538519                     34.0              9.000         L1       9.8        22.0      56.0          Compliance
      2.771062                     33.7              9.000         L1       9.8        22.3      56.0          Compliance
      2.977084                     34.9              9.000         L1       9.8        21.1      56.0          Compliance
      3.381891                     33.5              9.000         L1       9.8        22.5      56.0          Compliance
      3.575883                     32.1              9.000         L1       9.8        23.9      56.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.476287                     25.1              9.000         L1       9.9        21.3      46.4          Compliance
      0.524077                     24.1              9.000         L1       9.9        21.9      46.0          Compliance
      2.252540                     24.6              9.000         L1       9.8        21.4      46.0          Compliance
      2.344095                     19.8              9.000         L1       9.8        26.2      46.0          Compliance
      2.538519                     23.4              9.000         L1       9.8        22.6      46.0          Compliance
      2.771062                     24.1              9.000         L1       9.8        21.9      46.0          Compliance




                                                                                                                      Page 9 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                                         Report No.: RDG181026006-00E

AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                   Quasi-Peak Limit
                         60
                                                                                                      Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                         0
                         150k      300   400 500     800 1M        2M     3M     4M 5M 6   8 10M         20M     30M
                                                               Frequency in Hz



     Frequency                  Quasi Peak         Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      2.130339                     34.0              9.000         N        9.8        22.0      56.0          Compliance
      2.498385                     34.3              9.000         N        9.8        21.7      56.0          Compliance
      2.838101                     36.9              9.000         N        9.8        19.1      56.0          Compliance
      3.604490                     32.5              9.000         N        9.8        23.5      56.0          Compliance
      3.841741                     33.7              9.000         N        9.8        22.3      56.0          Compliance
      3.934683                     35.2              9.000         N        9.8        20.8      56.0          Compliance

     Frequency                   Average           Bandwidth               Corr.      Margin    Limit
                                                                  Line                                         Comment
       (MHz)                     (dBμV)              (kHz)                 (dB)        (dB)    (dBμV)
      0.472507                     27.6              9.000         N        9.9        18.9      46.5          Compliance
      0.524077                     26.8              9.000         N        9.9        19.2      46.0          Compliance
      1.229340                     25.3              9.000         N        9.8        20.7      46.0          Compliance
      1.418932                     26.3              9.000         N        9.8        19.7      46.0          Compliance
      1.464886                     25.2              9.000         N        9.8        20.8      46.0          Compliance
      1.802095                     26.1              9.000         N        9.8        19.9      46.0          Compliance




                                                                                                                  Page 10 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG181026006-00E

FCC§15.225, §15.205 & §15.209- RADIATED EMISSIONS
Applicable Standard
As per FCC Part 15.225
(a) The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed 15,848
    microvolts/meter at 30 meters.
(b) Within the bands 13.410–13.553 MHz and 13.567–13.710 MHz, the field strength of any emissions
    shall not exceed 334 microvolts/meter at 30 meters.
(c) Within the bands 13.110–13.410 MHz and 13.710–14.010 MHz the field strength of any emissions
    shall not exceed 106 microvolts/meter at 30 meters.

(d) The field strength of any emissions appearing outside of the 13.110–14.010 MHz band shall not exceed
    the general radiated emission limits in §15.209.

EUT Setup




The radiated emission tests were performed in the 3-meter chamber test site, using the setup accordance
with the ANSI C63.10-2013.

The spacing between the peripherals was 10 cm.




                                                                                              Page 11 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG181026006-00E

EMI Test Receiver Setup
The system was investigated from 9 kHz to 1 GHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

                       Frequency Range              RBW           Video B/W        Detector
                        9 kHz – 150 kHz             200 Hz           1 kHz            QP
                       150 kHz – 30 MHz             9 kHz           30 kHz            QP
                      30 MHz – 1000 MHz            120 kHz         300 kHz            QP

If the maximized peak measured value complies with the limit, then it is unnecessary to perform an QP
measurement.


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                  Corr. Ampl. = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                           Margin = Limit - Corr. Ampl.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
     Sunol Sciences           Antenna                JB3            A060611-1       2017-11-10     2020-11-10
         R&S             EMI Test Receiver           ESCI            100224         2018-12-10     2019-12-10
          HP                  Amplifier             8447D          2727A05902       2018-09-05     2019-09-05
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
       Unknown             Coaxial Cable          C-NJNJ-50         C-0400-01       2018-09-05     2019-09-05
       Unknown             Coaxial Cable          C-NJNJ-50         C-0075-01       2018-09-05     2019-09-05
       Unknown             Coaxial Cable          C-NJNJ-50         C-1000-01       2018-09-05     2019-09-05
         Farad             Test Software           EZ-EMC            V1.1.4.2           N/A           N/A

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 12 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181026006-00E

Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209&15.225.


Test Data
     Environmental Conditions

            Temperature:              22.3 oC
       Relative Humidity:              33 %
           ATM Pressure:              99.5 kPa

     * The testing was performed by Vern Shen on 2018-12-11.

Test Result: Pass




                                                                                          Page 13 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181026006-00E

Test mode: Transmitting

9 kHz~150 kHz:




                     Receiver                   Correction     Cord.
     Frequency                                                                Limit      Margin
                     Reading       Detector      Factor        Amp.
       (MHz)                                                                (dBμV/m)      (dB)
                     (dBμV)                       (dB)       (dBμV/m)
       0.0238         -17.76         peak         79.09        61.33         120.07       58.74
       0.0238          -21.79        AVG             79.09    57.30          120.07       62.77
       0.1207          -6.37         peak            65.63    59.26          105.97       46.71
       0.1207          -9.43         AVG             65.63    56.20          105.97       49.77
       0.1440          -9.83         peak            64.30    54.47          104.43       49.96
       0.1440          -12.90        AVG             64.30    51.40          104.43       53.03




                                                                                         Page 14 of 22


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181026006-00E

150kHz~30 MHz:




                                                            Fundamental




                    Receiver                   Correction     Cord.
    Frequency                                                                Limit      Margin
                    Reading       Detector      Factor        Amp.
      (MHz)                                                                (dBμV/m)      (dB)
                    (dBμV)                       (dB)       (dBμV/m)
      0.2096         19.97          peak         34.74        54.71         101.17       46.46
      2.2694          38.07         peak            15.51    53.58           69.54       15.96
      3.0156          40.72         peak            13.40    54.12           69.54       15.42
      4.7171          41.86         peak            11.01    52.87           69.54       16.67
      7.1646          23.13         peak            10.16    33.29           69.54       36.25
      16.0600         20.89         peak            9.26     30.15           69.54       39.39




                                                                                        Page 15 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181026006-00E

Fundamental:




                     Receiver                   Correction     Cord.
     Frequency                                                                Limit       Margin
                     Reading       Detector      Factor        Amp.
       (MHz)                                                                (dBμV/m)       (dB)
                     (dBμV)                       (dB)       (dBμV/m)
      13.5610         46.91          peak            9.36     56.27           124.00       67.73




                                                                                         Page 16 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG181026006-00E

30MHz-1GHz

Horizontal




                     Receiver                   Correction      Cord.
    Frequency                                                                  Limit       Margin
                     Reading       Detector      Factor         Amp.
      (MHz)                                                                  (dBμV/m)       (dB)
                     (dBμV)                       (dB)        (dBμV/m)
      30.0000         26.22          peak            1.76      27.98           40.00        12.02
      49.4000         36.87          peak            -10.97    25.90           40.00        14.10
      78.5000         34.75          peak            -11.13    23.62           40.00        16.38
     143.4900         36.84          peak            -5.94     30.90           43.50        12.60
     447.1000         30.98          peak            -1.14     29.84           46.00        16.16
     768.1700         27.77          peak            4.29      32.06           46.00        13.94




                                                                                          Page 17 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG181026006-00E

Vertical




                     Receiver                   Correction     Cord.
     Frequency                                                                Limit      Margin
                     Reading       Detector      Factor        Amp.
       (MHz)                                                                (dBμV/m)      (dB)
                     (dBμV)                       (dB)       (dBμV/m)
      30.0000         27.25          peak          1.76        29.01          40.00       10.99
      120.2100         37.78         peak            -4.82    32.96           43.50       10.54
      146.4000         30.41         peak            -6.00    24.41           43.50       19.09
      361.7400         29.06         peak            -2.79    26.27           46.00       19.73
      721.6100         27.21         peak            3.33     30.54           46.00       15.46
      781.7500         27.88         peak            4.44     32.32           46.00       13.68




                                                                                         Page 18 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG181026006-00E

FCC§15.225(e) - FREQUENCY STABILITY
Applicable Standard
As per FCC Part 15.225:

The frequency tolerance of the carrier signal shall be maintained within ±0.01% of the operating frequency
over a temperature variation of −20 degrees to +50 degrees C at normal supply voltage, and for a variation
in the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20 degrees
C. For battery operated equipment, the equipment tests shall be performed using a new battery.


Test Procedure
Frequency Stability vs. Temperature: The equipment under test was connected to an external DC power.
The EUT was placed inside the temperature chamber.

After the temperature stabilized for approximately 20 minutes, the frequency output was recorded from the
Spectrum Analyzer.

Frequency Stability vs. Voltage: An external variable DC power supply Source. The voltage was set to the
end point of the battery. The output frequency was recorded for each voltage.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver          ESCI             100224         2018-12-10     2019-12-10
          HP                  Amplifier             8447D          2727A05902       2018-09-05     2019-09-05
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
         UNI-T              Multimeter             UT39A           M130199938       2018-07-24     2019-07-24
                        Constant temperature
        ESPEC                                     ESX-4CA            018 463        2018-03-26     2019-03-26
                        and humidity Tester
     Pro instrument      DC Power Supply           pps3300           3300012            N/A           N/A
       Unknown             Coaxial Cable          C-NJNJ-50         C-0400-01       2018-09-05     2019-09-05

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 19 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG181026006-00E

Test Data
    Environmental Conditions

            Temperature:             22.3 oC
       Relative Humidity:                33 %
          ATM Pressure:              99.5 kPa

    * The testing was performed by Vern Shen on 2018-12-11.

   Test Mode: Transmitting

   Test Result: Pass

                                                fo = 13.56 MHz
                                                 Measured
              Temperature        Voltage                         Frequency Error      Limit
                                                 frequency
                    ℃              VDC             MHz                 Hz              Hz
                   -20                           13.55984             -160           ±1356
                   -10                           13.55984             -160           ±1356
                       0                         13.55984             -160           ±1356
                    10                           13.55990             -100           ±1356
                    20             3.85          13.55997              -30           ±1356
                    25                           13.55997              -33           ±1356
                    30                           13.55995              -50           ±1356
                    40                           13.55995              -50           ±1356
                    50                           13.55996              -40           ±1356
                    25             3.5           13.55989             -110           ±1356
                    25             4.2           13.56002              15            ±1356




                                                                                              Page 20 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG181026006-00E

FCC §15.215(c)– 20 dB BANDWIDTH TESTING
Applicable Standard

Per FCC §15.215 (c) Intentional radiators operating under the alternative provisions to the general
emission limits, as contained in §15.217 through § 15.257 and in Subpart E of this part, must be designed
to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth may otherwise be specified in
the specific rule section under which the equipment operates, is contained within the frequency band
designated in the rule section under which the equipment is operated. The requirement to contain the
designated bandwidth of the emission within the specified frequency band includes the effects from
frequency sweeping, frequency hopping and other modulation techniques that may be employed as well as
the frequency stability of the transmitter over expected variations in temperature and supply voltage. If a
frequency stability is not specified in the regulations, it is recommended that the fundamental emission be
kept within at least the central 80% of the permitted band in order to minimize the possibility of out-of -
band operation.

Test Procedure
Measure the frequency difference of two frequencies that were attenuated 20 dB from the reference level.
Record the frequency difference as the emission bandwidth.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer           Description             Model
                                                                     Number            Date        Due Date
         R&S             EMI Test Receiver          ESCI             100224         2018-12-10     2019-12-10
          HP                  Amplifier             8447D          2727A05902       2018-09-05     2019-09-05
        EMCO                Passive Loop             6512           9706-1206       2017-03-05     2020-03-04
       Unknown             Coaxial Cable          C-NJNJ-50         C-0400-01       2018-09-05     2019-09-05
       Unknown             Coaxial Cable          C-NJNJ-50         C-1000-01       2018-09-05     2019-09-05

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 21 of 22


 Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG181026006-00E

Test Data
     Environmental Conditions

            Temperature:              22.3 oC
       Relative Humidity:              33 %
           ATM Pressure:              99.5 kPa

     * The testing was performed by Vern Shen on 2018-12-11.

Test Result: Pass

Test Mode: Transmitting

                                 Frequency                     20 dB Bandwidth
                                   (MHz)                            (KHz)

                                   13.56                            0.786



                                                 20 dB Bandwidth




                                   ***** END OF REPORT *****



                                                                                             Page 22 of 22



Document Created: 2019-01-14 17:54:19
Document Modified: 2019-01-14 17:54:19

© 2024 FCC.report