Part 24 Test Report

FCC ID: JOYIUD19AB

Test Report

Download: PDF
FCCID_706026

                                                                                Test report No.    : 26KE0199-HO-C
                                                                                Page               : 1 of 31
                                                                                Issued date        : August 30, 2006
                                                                                FCC ID             : JOYIUD19AB




                               EMI TEST REPORT
                              Test Report No. : 26KE0199-HO-C
          Applicant                         :         KYOCERA Corporation

          Type of Equipment                 :         iBurst User Terminal

          Model No.                         :         UTD1900D-US-B

          Test standard                     :         FCC Part 24 2005

          FCC ID                            :         JOYIUD19AB

          Test Result                       :         Complied
          1.   This test report shall not be reproduced in full or partial, without the written approval of
               UL Apex Co., Ltd.
          2.   The results in this report apply only to the sample tested.
          3.   This equipment is in compliance with the above regulation. We hereby certify that the data contain a
               true representation of the EMC profile.
          4.   The test results in this report are traceable to the national or international standards.

                       Date of test:
                                                      August 5 to 18, 2006
                                                ______________________________

                       Tested by:
                                                ______________________________
                                                           Kenichi Adachi
                                                           EMC Services

                       Approved by :
                                                ______________________________
                                                          Naoki Sakamoto
                                                    Group Leader of EMC Services

                                                      This laboratory is accredited by the NVLAP LAB CODE
                                                      200572-0, U.S.A. The tests reported herein have been
                                                      performed in accordance with its terms of accreditation.
                                                      *As for the range of Accreditation in NVLAP, you may

       NVLAP LAB CODE: 200572-0                       refer to the WEB address, http://ulapex.jp/emc/nvlap.htm


UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                  MF060b(14.06.06)


                                                                                               Test report No.       : 26KE0199-HO-C
                                                                                               Page                  : 2 of 31
                                                                                               Issued date           : August 30, 2006
                                                                                               FCC ID                : JOYIUD19AB


CONTENTS                                                                                                                        PAGE

SECTION 1: Client information................................................................................................ 3
SECTION 2: Equipment under test (E.U.T.) ........................................................................... 3
SECTION 3: Test specification, procedures & results ............................................................ 4
SECTION 4: Operation of E.U.T. during testing..................................................................... 6
SECTION 5: Peak Output Power and Spurious Radiation and Band-Edge......................... 7
SECTION 6: Bandwidth and Band-Edge (Conducted)........................................................... 8
SECTION 7: Spurious Emission (Conducted) ......................................................................... 8
SECTION 8: Frequency Stability.............................................................................................. 8
APPENDIX 1: Photographs of test setup.................................................................................. 9
            Spurious Radiation ......................................................................................................9
          Worst Case Position (Horizontal: EUT-Y-axis, Ant-90deg. / Vertical:EUT-X-axis, Ant-
            90deg.) .........................................................................................................................10
            Frequency Stability....................................................................................................11
APPENDIX 2: Data of EMI test .............................................................................................. 12
              Peak Output Power (Conducted) .............................................................................12
              Peak Output Power (Radiated) ................................................................................14
              Emission Bandwidth and 99%Occupied Bandwidth .............................................15
              Band Edge(Conducted) .............................................................................................17
              Band Edge (Radiated) ...............................................................................................22
              Spurious Emission (Conducted) ...............................................................................23
              Spurious Radiation ....................................................................................................27
              Frequency Stability(Temperature/Voltage Variation)...........................................30
APPENDIX 3: Test instruments ............................................................................................... 31




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                                    MF060b(14.06.06)


                                                                             Test report No.   : 26KE0199-HO-C
                                                                             Page              : 3 of 31
                                                                             Issued date       : August 30, 2006
                                                                             FCC ID            : JOYIUD19AB


SECTION 1: Client information
Company Name                       :       KYOCERA Corporation
Address                            :       Yokohama Office
                                           2-1-1 Kagahara, Tsuzuki-ku, Yokohama-shi, Kanagawa 224-8502, Japan
Telephone Number                   :       +81-45-943-6189
Facsimile Number                   :       +81-45-943-6123
Contact Person                     :       Toshihiko Kawata



SECTION 2: Equipment under test (E.U.T.)
2.1     Identification of E.U.T.

Type of Equipment                  :       iBurst User Terminal
Model No.                          :       UTD1900D-US-B
Serial No.                         :       01
Rating                             :       AC 120V / 60Hz (AC Adapter), 8.55-9.45V(EUT)
Country of Manufacture             :       JAPAN
Receipt Date of Sample             :       July 28, 2006
Condition of EUT                   :       Production model
Modification of EUT                :       No modification by the test lab.

2.2     Product Description

Model No.: UTD1900D-US-B (referred to as the EUT in this report) is iBurst User Terminal.

Equipment Type                         :   Transceiver
Frequency operation                    :   1900-1910MHz
Type of modulation                     :   BPSK,QPSK,8PSK,12QAM,16QAM
Bandwidth                              :   500kHz
Channel spacing                        :   625kHz
Channel number                         :   16
Antenna Type                           :   integrated mono-pole antenna
Antenna connector Type                 :   MMCX
Antenna Gain                           :   4dBi
Other Clock Frequency                  :   72MHz, 25MHz, 24MHz, 20MHz, 18MHz, 6MHz, 3MHz, 32.768kHz
Temperature of operation               :   0 deg. C. to + 40 deg. C.




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                              MF060b(14.06.06)


                                                                              Test report No.   : 26KE0199-HO-C
                                                                              Page              : 4 of 31
                                                                              Issued date       : August 30, 2006
                                                                              FCC ID            : JOYIUD19AB


SECTION 3: Test specification, procedures & results

3.1     Test Specification

Test Specification                :        FCC Part 24 2005

Title                             :        FCC 47CFR Part 24
                                           Personal Communications Services

3.2     Procedures and results

Item            Test Method           FCC Regulations Remarks Deviation Worst margin Results
Peak Output     Section 2.1046        Section 24.232(b) Conducted/ N/A  2.0dB         Complied
Power                                                   Radiated        1904.6875MHz,
                                                                        Horizontal
Emission        Section 2.1049        Section 24.238(b) Conducted N/A   -             Complied
Bandwidth,
99% Occupied
Bandwidth

Band-Edge       Section 2.1049        Section 24.238(b) Conducted/ N/A           0.79dB            Complied
                                                        Radiated                 1900MHz
                                                                                 QPSK+
Spurious        Section 2.1051        Section 24.238(a) Conducted N/A            -                 Complied
Emission
Spurious        Section 2.1053        Section 24.238(a) Radiated    N/A          8.9dB         Complied
Radiation                                                                        13302.188MHz,
                                                                                 Horizontal
Frequency        Section 2.1055(a) (1) Section 24.235     Conducted N/A          -             Complied
Stability        and (b)
(Temperature
Variation)
Frequency        Section 2.1055(d)(1) Section 24.235      Conducted N/A            -                  Complied
Stability        and (2)
(Voltage
Variation)
Note: UL Apex’s EMI Work Procedures No. QPM05
 *These tests were also referred to TIA-603-B “ Land Mobile FM or PM Communications Equipment Measurement
 and Performance Standards.”
 *These tests were performed without any deviations from test procedure except for additions or exclusions.




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                               MF060b(14.06.06)


                                                                                        Test report No.    : 26KE0199-HO-C
                                                                                        Page               : 5 of 31
                                                                                        Issued date        : August 30, 2006
                                                                                        FCC ID             : JOYIUD19AB

3.3      Confirmation

UL Apex Co., Ltd. hereby confirms that E.U.T., in the configuration tested, complies with the specifications
Part 24: 2005.

3.4      Uncertainty

Antenna terminal measurements
The measurement uncertainty (with a 95% confidence level) for this test is ±3.0dB
The data listed in this report meets the limits unless the uncertainty is taken into consideration.

Radiated emissions
The measurement uncertainty (with a 95% confidence level) for this test is ±4.62dB(30-1000MHz) and ±5.06dB(Above 1GHz).
The data listed in this report meets the limits unless the uncertainty is taken into consideration.


3.5 Test Location

UL Apex Co., Ltd. Head Office EMC Lab. *NVLAP Lab. code: 200572-0
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone         : +81 596 24 8116           Facsimile         : +81 596 24 8124
                       FCC           IC Registration    Width x Depth x       Size of                              Other
                       Registration Number                  Height (m)        reference ground plane (m) /         rooms
                       Number                                                 horizontal conducting plane
 No.1 semi-anechoic    313583        IC4247A            19.2 x 11.2 x 7.7m    7.0 x 6.0m                           Preparation
 chamber                                                                                                           room
 No.2 semi-anechoic     655103         IC4247A-2           7.5 x 5.8 x 5.2m       4.0 x 4.0m                       -
 chamber
 No.3 semi-anechoic     148738         IC4247A-3           12.0 x 8.5 x 5.9m      6.8 x 5.75m
 chamber
 No.3 shielded room     -              -                   4.0 x 6.0 x 2.7m       N/A                              -
 No.4 semi-anechoic     134570         IC4247A-4           12.0 x 8.5 x 5.9m      6.8 x 5.75m                      -
 chamber
 No.4 shielded room     -              -                   4.0 x 6.0 x 2.7m       N/A                              -
 No.5 shielded room     -              -                   6.0 x 6.0 x 3.9m       N/A                              -
 No.6 shielded          -              -                   4.0 x 4.5 x 2.7m       N/A                              -
 room
 No.6 measurement       -              -                   4.75 x 5.4 x 3.0m      N/A                              -
 room
 No.7 shielded room     -              -                   4.7 x 7.5 x 2.7m       4.7 x 7.5m                       -
 No.8 measurement         -              -                  3.1 x 5.0 x 2.7m        N/A                              -
 room
* Size of vertical conducting plane (for Conducted Emission test) : 2.0 x 2.0m for No.1, No.2, No.3 and No.4 semi-anechoic chambers
and No.7 shielded room.

3.6    Test set up, Test instruments and Data of EMI

Refer to APPENDIX 1 to 3.




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                          MF060b(14.06.06)


                                                                                 Test report No.    : 26KE0199-HO-C
                                                                                 Page               : 6 of 31
                                                                                 Issued date        : August 30, 2006
                                                                                 FCC ID             : JOYIUD19AB


SECTION 4: Operation of E.U.T. during testing
4.1      Operating Modes

The EUT was operated in a manner similar to typical use during the tests.

The mode is used :         Transmitting mode
                           Low Channel     :1900.3125MHz (Ch0)
                           Mid Channel     :1904.6875MHz (Ch7)
                           High Channel    :1909.6875MHz (Ch15)

Justification: The system was configured in typical fashion (as a customer would normally use it) for testing.

4.2 Configuration and peripherals
                                                                       Not used for Radiated
                                       3          B                    emission test.
                            A:EUT


                                                        1
                                   4
                                                  C
                               D

                                                    2
                                   5

                                             AC120V / 60Hz
                                                                  Standard Ferrite Core for B.
                          AC120V / 60Hz

* Cabling and setup were taken into consideration and test data was taken under worst case conditions.

Description of EUT and Support equipment
 No.     Item                    Model number                 Serial number        Manufacturer        Remarks
 A       iBurst User Terminal    UTD1900D-US-B                01                   KYOCERA             EUT
 B       PC                      TYPE2662-LBJ                 FX-FL781             IBM                 -
         AC Adapter for PC       AA21131                      11S02K6657Z1Z        IBM                 -
 C
                                                              0ZA0651RX
 D        AC Adapter                   TYPEFW7400/09          2106B                FWHK                -

List of cables used
 No.      Name                         Length (m)             Shield                                   Remarks
                                                              Cable                Connector
 1        DC Cable                     1.8                       Unshielded          Unshielded        -
 2        AC Cable                     1.0                       Unshielded          Unshielded        -
 3        USB Cable                    2.0                        Shielded            Shielded         -
 4        DC Cable                     2.0                       Unshielded          Unshielded        -
 5        AC Cable                     2.0                       Unshielded          Unshielded        -




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                   MF060b(14.06.06)


                                                                                  Test report No.    : 26KE0199-HO-C
                                                                                  Page               : 7 of 31
                                                                                  Issued date        : August 30, 2006
                                                                                  FCC ID             : JOYIUD19AB


SECTION 5: Peak Output Power and Spurious Radiation and Band-Edge

[Conducted]

Test Procedure
The peak output power (conducted) was measured with a spectrum analyzer and an attenuator at the antenna port.

Test data                          :         APPENDIX 3
Test result                        :         Pass

[Radiated]

Test Procedure
1)      EUT was placed on a urethane platform of nominal size, 1.0m by 0.5m, raised 80cm above the conducting
        ground plane. Test was made with the antenna positioned in both the horizontal and vertical planes of
        polarization.
        The Radiated Electric Field Strength intensity has been measured in a semi anechoic chamber with a ground plane
        and at a distance of 3m.
        The measuring antenna height was varied between 1 to 4m and EUT was rotated a full revolution in order
        to obtain the maximum value of the electric field intensity.

2)      Exchanged the EUT to the Substitution Antenna, the measurement was set for the same height 0.8m as the
        EUT. The frequency below 1GHz of the Substitution Antenna was used as the Half wave dipole Antenna,
        which is harmonized with the measured frequency in 1).
        The frequency above 1GHz of the Substitution Antenna was used with Horn Antenna.
        The Substitution Antenna was connected with the Signal Generator, and the polarized electromagnetic
        radiation of the Substitution Antenna was matched with the one of the measuring Antenna, which was set with
        the Signal Generator to the measured frequency in 1). Then, we set with the Output power (CW) of the Signal
        Generator where the measuring electromagnetic field is equal to the measured value in 1).
        The measuring antenna height varied between 1 and 4m to obtain the maximum receiving level.
        Its Output power of Signal Generator was recorded.

3)      Equivalent isotropic radiated power was calculated by subtracting the cable loss and the attenuator loss connected
        between the Signal Generator and the Substitution Antenna from the Output power of the Signal
        Generator recorded in 2).

Test data                          :         APPENDIX 3
Test result                        :         Pass

- The carrier level and noise levels were confirmed at each position of X and Y axes of EUT and 90 and 180 deg. of EUT’s
antenna to see the position of maximum noise, and the test was made at the position that has the maximum noise.




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                    MF060b(14.06.06)


                                                                               Test report No.   : 26KE0199-HO-C
                                                                               Page              : 8 of 31
                                                                               Issued date       : August 30, 2006
                                                                               FCC ID            : JOYIUD19AB


SECTION 6: Bandwidth and Band-Edge (Conducted)

Test Procedure
The Emission Bandwidth, 99% Occupied Bandwidth and Band-Edge was measured with a spectrum analyzer and attenuator
connected to the antenna port.

Test data                          :        APPENDIX 3
Test result                        :        Pass



SECTION 7: Spurious Emission (Conducted)

Test Procedure
The Spurious Emission was measured with a spectrum analyzer and attenuator connected to the antenna port.

Test data                          :        APPENDIX 3
Test result                        :        Pass



SECTION 8: Frequency Stability
Test Procedure
The Frequency Stability was measured with a Vector Signal Analyzer (89441A (HP)) connected to the antenna port.
The Frequency Drift was measured with the 10 deg. C. steps from –30 deg.C. to 50 deg.C., and it is presented as the
ppm unit. The Frequency Drift was measured with the normal temperature(20 deg.C.) and Voltage tolerance (0 %,
+15%, -15%), and it is presented as the ppm unit.

Test data                          :        APPENDIX 3
Test result                        :        Pass




UL Apex Co., Ltd.
Head Office EMC Lab.
4383-326 Asama-cho, Ise-shi, Mie-ken 516-0021 JAPAN
Telephone       : +81 596 24 8116
Facsimile       : +81 596 24 8124                                                                MF060b(14.06.06)



Document Created: 2006-08-31 09:58:42
Document Modified: 2006-08-31 09:58:42

© 2024 FCC.report