                                                           RF Exposure Report

                       Report No.: SA190116E05A

                            FCC ID: JNZMR0080B

                       Test Model: MR0080

                 Received Date: Feb. 23, 2019

                         Test Date: Feb. 23 to Mar. 07, 2019

                     Issued Date: Mar. 13, 2019


                         Applicant: LOGITECH FAR EAST LTD.

                          Address: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.
            Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                           Taiwan R.O.C.
       FCC Registration /
                           723255 / TW2022
      Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by any government agencies.
Report No.: SA190116E05A                                             Page No. 1 / 7                                             Report Format Version: 6.1.1
Reference No.: 190226E14


                                                                  Table of Contents
Release Control Record .................................................................................................................................. 3
1        Certificate of Conformity ...................................................................................................................... 4
2        Evaluation Result .................................................................................................................................. 5
3        SAR Test Exclusion Thresholds .......................................................................................................... 6
4        Conclusion ............................................................................................................................................ 7




Report No.: SA190116E05A                                            Page No. 2 / 7                                             Report Format Version: 6.1.1
Reference No.: 190226E14


                                          Release Control Record


Issue No.             Description                                         Date Issued
SA190116E05A          Original release.                                   Mar. 13, 2019




Report No.: SA190116E05A                     Page No. 3 / 7        Report Format Version: 6.1.1
Reference No.: 190226E14


1    Certificate of Conformity


            Product: Wireless Mouse

              Brand: logitech G

        Test Model: MR0080

    Sample Status: ENGINEERING SAMPLE

          Applicant: LOGITECH FAR EAST LTD.

          Test Date: Feb. 23 to Mar. 07, 2019

         Standards: FCC Part 2 (Section 2.1093)

                           KDB 447498 D01 General RF Exposure Guidance v06
                           IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              ,   Date:      Mar. 13, 2019
                                 Claire Kuan / Specialist




     Approved by :                                               ,   Date:      Mar. 13, 2019
                                  May Chen / Manager




Report No.: SA190116E05A                        Page No. 4 / 7                       Report Format Version: 6.1.1
Reference No.: 190226E14


2       Evaluation Result


Following FCC KDB 447498 D01 “General SAR test exclusion guidance”

The corresponding SAR Exclusion Threshold condition, listed below:

1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
    mm are determined by:
    [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)]
    ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
                                                                 .
                                            to the nearest mW and mm before calculation.
                                                                      The test exclusions are applicable only
          when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100
          MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied
          to determine SAR test exclusion.

2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
    determined according to the following:
    a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)·( f(MHz)/150)] mW, at 100MHz to
        1500 MHz
    b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6
         GHz

3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
    a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 +
        log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
    b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
         separation distances ≤ 50 mm.
    c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot
         be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to
         be acceptable.




Report No.: SA190116E05A                         Page No. 5 / 7                         Report Format Version: 6.1.1
Reference No.: 190226E14


3     SAR Test Exclusion Thresholds

GFSK Avg. Power Table
                                    Frequency                      Average Power                  Average Power
       Channel
                                     (MHz)                             (mW)                             (dBm)
            1                         2402                             1.276                                1.06
            41                        2442                             6.792                                8.32
            80                        2481                             6.668                                8.24


For GFSK SAR Test Exclusion Thresholds
                                                              Min. test         SAR test
                                             Max Avg.                                          10-g SAR test
    Frequency          Max Avg. Power                        separation         exclusion
                                              Power                                              exclusion           Result
      (MHz)                (dBm)                              distance         calculation
                                              (mW)                                              thresholds
                                                                (mm)           value(NOTE 1)
    2402 ~ 2481              8.32             6.792                5              2.123               7.5            Pass
    Note:        1. Calculate SAR test exclusion thresholds from condition “1” formulas.


BT 5.0 1M Avg. Power Table
                                                                                       Avg. Power
            Channel                   Frequency (MHz)
                                                                          (mW)                              (dBm)
                   0                         2402                         5.321                              7.26
                  19                         2440                         5.188                              7.15
                  39                         2480                           5                                6.99
BT 5.0 2M Avg. Power Table
                                                                                       Avg. Power
            Channel                   Frequency (MHz)
                                                                          (mW)                              (dBm)
                   1                         2404                         5.321                              7.26
                  19                         2440                         5.188                              7.15
                  38                         2478                         5.012                              7.00

For BT 5.0 1M SAR Test Exclusion Thresholds
                                                           Min. test       SAR test
                        Max Avg.        Max Avg.                                           10-g SAR test
    Frequency                                             separation       exclusion
                         Power           Power                                               exclusion              Result
      (MHz)                                                distance       calculation
                         (dBm)           (mW)                                               thresholds
                                                             (mm)         value(NOTE 1)

 2402 ~ 2480               7.26           5.321                5               1.649            7.5                 Pass
    NOTE: 1. Calculate SAR test exclusion thresholds from condition “1” formulas.
          2. *Time Avg. Power= Avg. Power+Duty factor
For BT 5.0 2M SAR Test Exclusion Thresholds
                                                 Min. test       SAR test
                  Max Avg.       Max Avg.                                      10-g SAR test
  Frequency                                     separation       exclusion
                   Power           Power                                          exclusion                         Result
    (MHz)                                        distance       calculation
                    (dBm)          (mW)                               (NOTE 1)   thresholds
                                                   (mm)        value

 2404 ~ 2478               7.26           5.321                5               1.649            7.5                 Pass
    NOTE:        1. Calculate SAR test exclusion thresholds from condition “1” formulas.
                 2. *Time Avg. Power= Avg. Power+Duty factor



Report No.: SA190116E05A                              Page No. 6 / 7                             Report Format Version: 6.1.1
Reference No.: 190226E14


4    Conclusion
The device of GFSK and BT-LE modulation type can't transmit simultaneously.
Since Source-base time average power is below SAR test exclusion power thresholds, the SAR evaluation is
not required.


--- END ---




Report No.: SA190116E05A                    Page No. 7 / 7                        Report Format Version: 6.1.1
Reference No.: 190226E14



Document Created: 2019-03-13 10:17:08
Document Modified: 2019-03-13 10:17:08

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC