Test Report (JBP).pdf

FCC ID: JNZMR0069

Test Report

Download: PDF
FCCID_3397269

                                                FCC Certification Test Report

                       Report No.: FC170421E11

                       Test Model: M-R0069

                 Received Date: Apr. 23, 2017

                         Test Date: Apr. 26 to 29, 2017

                     Issued Date: May 08, 2017


                         Applicant: LOGITECH FAR EAST LTD.

                          Address: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.
             Test Location (1): E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                Taiwan R.O.C.
             Test Location (2): No. 49, Ln. 206, Wende Rd., Shangshan Tsuen, Chiung Lin Hsiang, Hsin
                                Chu Hsien 307, Taiwan R.O.C.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification.
The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.


Report No.: FC170421E11                                              Page No. 1 / 22                                            Report Format Version: 6.1.2


                                                                    Table of Contents
Release Control Record .................................................................................................................................. 3
1     Certificate of Conformity ......................................................................................................................... 4
2     Summary of Test Results......................................................................................................................... 5
    2.1     Measurement Uncertainty ................................................................................................................... 5
    2.2     Modification Record ............................................................................................................................ 5
3     General Information ................................................................................................................................. 6
    3.1     Features of EUT .................................................................................................................................. 6
    3.2     General Description of EUT ................................................................................................................ 6
    3.3     Operating Modes of EUT and Determination of Worst Case Operating Mode ................................... 7
    3.4     Test Program Used and Operation Descriptions ................................................................................. 7
    3.5     Primary Clock Frequencies of Internal Source ................................................................................... 7
    3.6     Miscellaneous ...................................................................................................................................... 8
4     Configuration and Connections with EUT ............................................................................................. 9
    4.1     Connection Diagram of EUT and Peripheral Devices ......................................................................... 9
    4.2     Configuration of Peripheral Devices and Cable Connections ........................................................... 10
5     Radiated Emissions up to 1 GHz ........................................................................................................... 11
    5.1     Limits .................................................................................................................................................. 11
    5.2     Test Instruments ................................................................................................................................ 12
    5.3     Test Arrangement .............................................................................................................................. 13
    5.4     Supplementary Information ............................................................................................................... 13
    5.5     Test Results ....................................................................................................................................... 14
6     Radiated Emissions above 1 GHz......................................................................................................... 16
    6.1     Limits ................................................................................................................................................. 16
    6.2     Test Instruments ................................................................................................................................ 17
    6.3     Test Arrangement .............................................................................................................................. 18
    6.4     Supplementary Information ............................................................................................................... 18
    6.5     Test Results ....................................................................................................................................... 19
7     Pictures of Test Arrangements ............................................................................................................. 21
Appendix – Information on the Testing Laboratories ................................................................................ 22




Report No.: FC170421E11                                               Page No. 2 / 22                                              Report Format Version: 6.1.2


                                              Release Control Record


Issue No.                 Description                                         Date Issued
FC170421E11               Original release.                                   May 08, 2017




Report No.: FC170421E11                          Page No. 3 / 22       Report Format Version: 6.1.2


1    Certificate of Conformity


            Product: 2.4GHz Cordless Mouse

              Brand: Logitech

        Test Model: M-R0069

    Sample Status: ENGINEERING SAMPLE

          Applicant: LOGITECH FAR EAST LTD.

          Test Date: Apr. 26 to 29, 2017

         Standards: 47 CFR FCC Part 15, Subpart B, Class B
                          ICES-003:2016 Issue 6, Class B
                          ANSI C63.4:2014



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




            Prepared by :                                                 ,   Date:       May 08, 2017
                                        Claire Kuan / Specialist




            Approved by :                                                 ,   Date:       May 08, 2017
                                            Ken Lu / Manager




Report No.: FC170421E11                         Page No. 4 / 22                       Report Format Version: 6.1.2


                                                                                                               6 U h EAU




2      Summary of Test Results

47 CFR ECC Part 15, Subpart B / ICES—003:2016 Issue 6, Class B

ANSI C63.4:2014
  FCC     ICES—003                                                                                             .
 Clause    Clause                       Test Item                       Result/Remarks                    Verdict
                            AC Power Line Conducted           Not applicable, because the port is
    15.107         61       Emissions                        absent in the EUT                              NA
                  6.21      Radiated Emissions up to 1       Minimum passing Class B margin                 Pass
                   "C       GHz                              is —6.08 dB at 106.48 MHz
    15.109                      —       ——                      —            —            —
                  6.2.2     Radiated Emissions above 1|      Minimum passing Class B margin                 Pass
                   "C       GHz                              is —15.20 dB at 4212.62 MHz
Note: There is no deviation to the applied test methods and requirements covered by the scope of this report.


2.1     Measurement Uncertainty
Where relevant, the following measurement uncertainty levels have been estimated for tests performed on
the EUT:
The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note that
the uncertainty values are provided for informational purposes only and are not used in determining the
PASS/FAIL results.

                       Measurement                                    Frequency             EXpaszESZl)J?f;arlamty
             Radiated Emissions up to 1 GHz                       SOMHz ~ 1GHz                      3.91 dB
                                                                           6GHz
                                                                   1GHz —~ iaGhz                    4.39 dB
                                                                                                         as
                                       ab
                          Emissionsns above
              adiateded Emissio
             Radiat                         1 GH z                sGrHz                             Tor



2.2      Modification Record
There were no modifications required for compliance.




Report No.: FC170421E11                              Page No. 5/ 22                           Report Format Version: 6.1.2


3     General Information
3.1     Features of EUT
The tests reported herein were performed according to the method specified by LOGITECH FAR EAST LTD.,
for detailed feature description, please refer to the manufacturer's specifications or user's manual.


3.2     General Description of EUT

 Product                     2.4GHz Cordless Mouse
 Brand                       Logitech
 Test Model                  M-R0069
 Sample Status               ENGINEERING SAMPLE
 Operating Software          NA
 Power Supply Rating         DC 1.5V from battery
 Accessory Device            NA
 Data Cable Supplied         NA
Note:
1. The EUT may have a lot of colors for marketing requirement.
2. The antenna provided to the EUT, please refer to the following table:
                                  Frequency
    Antenna Gain (dBi)                                       Antenna Type             Connecter Type
                                 range(GHz)
            -1.33                 2.4-2.4835                     PIFA Antenna                NA

3. The above EUT information is declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or user's manual.
The USB port of the EUT is only for charging the rechargeable battery. And the EUT has wireless function
under charging mode.




Report No.: FC170421E11                        Page No. 6 / 22                      Report Format Version: 6.1.2


3.3    Operating Modes of EUT and Determination of Worst Case Operating Mode

For radiated test, the EUT has been pre-tested under following test modes, and test mode A was the worst
case for final test.
                                               Test Condition
 Mode                          Mode                                          Remark
  A                       USB GFSK Dongle                                Normal operation
  B                          BTLE Link                                   Normal operation
  C                       USB GFSK Dongle                                 Standby mode

Test modes are presented in the report as below.
                                              Test Condition
                                          Radiated emission test
 Mode                         Mode                                           Remark
   1                  USB GFSK Dongle                                    Normal operation



3.4    Test Program Used and Operation Descriptions


1. Turn on the power of all equipment.
2. EUT link support unit B (Laptop) by GFSK Mode via support unit C (2.4GHz Transceiver).
3. Support unit B (Laptop) runs” EMC test.exe” then sends "H" messages to itself.



3.5    Primary Clock Frequencies of Internal Source

The EUT is a 2.4GHz GFSK, provided by LOGITECH FAR EAST LTD., for detailed internal source, please
refer to the manufacturer's specifications.




Report No.: FC170421E11                       Page No. 7 / 22                       Report Format Version: 6.1.2


3.6    Miscellaneous
Labelling Requirements for Part 15 Devices:
     Verification
The specific labelling requirements for a device subject to the Verification procedure are contained in Section
15.19(a). These labelling requirements are:
If the device is subject only to Verification, include a label bearing a unique identifier (Section 2.954) and one
of three compliance statements specified in Section 15.19(a). If the labeling area for the device is so small,
and/or it is not practical to place the compliance statement on the device, then the statement can be placed in
the user manual or product packaging (Section 15.19(a)(5)). However, the device must still be labelled with
the unique identifier (Verification). Generally, devices smaller than the palm of the hand are considered too
small for the compliance statement.
     Certification
If the device is subject to Certification: (1) Section 2.925 contains information on identification of the
equipment; (2) include a label bearing an FCC Identifier (FCC ID) (Section 2.926) and (3) include the
appropriate compliance statement in Section 15.19(a). If the device is considered too small and therefore it is
impractical (smaller than the palm of the hand) to display the compliance statement, then the statement may
be placed in the user manual or product packaging. However, the device must still be labelled with the FCC ID.
If the device is unquestionably too small for the FCC ID to be readable (smaller than 4-6 points), the FCC ID
may be placed in the user manual. However, it must be determined that the device itself is too small – the
label area allocated to the FCC ID may not be reduced because of over crowded identification of other
product and regulatory information.
An electronic display of the FCC ID (see 9. Electronic Labelling below) may be used for Certification of
Section 15.212 modular transmitters and software defined radios (Section 2.944).
     Declaration of Conformity (DoC):
The labelling requirements for a device subject to the DoC procedure are specified in Section 15.19(b). The
label should include the FCC logo along with the Trade Name and Model Number, which satisfies the unique
identifier requirement of Section 2.1074 if it represents the identical equipment tested for DoC compliance.
For personal computers assembled from authorized components, the following additional text must also be
included: “Assembled from tested components,” “Complete system not tested.” When the device is so small
and/or when it is not practical to place the required additional text on the device, the text may be placed in the
user manual or pamphlet supplied to the user. However, the FCC logo, Trade Name, and Model Number must
still be displayed on the device (Section 15.19(b)(3)).




                            Part 15 Declaration of Conformity (DoC) Label Examples
Equipment certified as software defined radio may use a means that readily displays the FCC ID on an
electronic display screen, instead of labelling the device (Section 2.925 (e)).
Further information may refer to FCC KDB:784748 D01 Labelling Part 15 &18 Guidelines
Labelling Requirements for ICES-003 Devices:
     Industry Canada ICES-003 Compliance Label:
CAN ICES-3 (*)/NMB-3(*)
* Insert either “A” or “B” but not both to identify the applicable Class of ITE.


Report No.: FC170421E11                          Page No. 8 / 22                         Report Format Version: 6.1.2


4     Configuration and Connections with EUT
4.1    Connection Diagram of EUT and Peripheral Devices




Report No.: FC170421E11                  Page No. 9 / 22   Report Format Version: 6.1.2


4.2     Configuration of Peripheral Devices and Cable Connections
 ID          Product            Brand              Model No.             Serial No.             FCC ID              Remarks
  A           i-pod             Apple             MC749TA/A          CC4DMFJUDFDM              FCC DoC          Provided by Lab
  B          Laptop             DELL             Latitude E5440          519OP32               FCC DoC          Provided by Lab
  C    2.4GHz Transceiver      Logitech            C-U0008                  NA                       NA         Supplied by client
  D           Printer          EPSON               LQ-300+II            G88Y074083             FCC DoC          Provided by Lab
Note:
1. All power cords of the above support units are non-shielded (1.8m).


                                                                        Shielding
 ID           Descriptions                Qty.         Length (m)                     Cores (Qty.)            Remarks
                                                                        (Yes/No)
 1.           USB Cable                    1               0.1             Yes             0               Provided by Lab
 2.           USB Cable                    1               1.8             Yes             0               Provided by Lab
Note: The cores are originally attached to the cables.




Report No.: FC170421E11                                        Page No. 10 / 22                           Report Format Version: 6.1.2


5     Radiated Emissions up to 1 GHz
5.1    Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
                             Radiated Emissions Limits at 10 meters (dBμV/m)
  Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                   CISPR 22, Class A CISPR 22, Class B
      (MHz)             Class A                 Class B
      30-88                39                      29.5
      88-216              43.5                     33.1                    40                      30
     216-230
                          46.4                     35.6
     230-960
                                                                           47                      37
    960-1000              49.5                     43.5

                              Radiated Emissions Limits at 3 meters (dBμV/m)
    Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                 CISPR 22, Class A      CISPR 22, Class B
       (MHz)            Class A                Class B
       30-88              49.5                    40
       88-216              54                    43.5                   50.5                     40.5
      216-230
                           56.9                     46
      230-960
                                                                       57.5                      47.5
     960-1000              60                       54

Notes: 1. The lower limit shall apply at the transition frequencies.
       2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
       3. QP detector shall be applied if not specified.




Report No.: FC170421E11                       Page No. 11 / 22                       Report Format Version: 6.1.2


5.2     Test Instruments
      DESCRIPTION &                                                   CALIBRATED         CALIBRATED
                                MODEL NO.           SERIAL NO.
      MANUFACTURER                                                       DATE               UNTIL

      Test Receiver          N9038A              MY50010125         Apr. 15, 2017       Apr. 14, 2018
      Agilent
                             N9038A              MY50010132         June 28, 2016       June 27, 2017
      Pre-Amplifier          310N                352925             Aug. 29, 2016       Aug. 28, 2017
      Sonoma                 310N                352926             Aug. 29, 2016       Aug. 28, 2017
      Trilog Broadband       VULB 9168           9168-359           Dec. 28, 2016       Dec. 27, 2017
      Antenna
                             VULB 9168           9168-358           Dec. 16, 2016       Dec. 15, 2017
      SCHWARZBECK
      Fixed attenuator       UNAT-5+             CHF-001            Sep. 9, 2016        Sep. 08, 2017
      Mini-Circuits          UNAT-5+             CHF-002            Sep. 9, 2016        Sep. 08, 2017
                                                 CHFCAB-001-1
                                                 CHFCAB-001-3       Sep. 22, 2016       Sep. 21, 2017
                                                 CHFCAB-001-4
      RF Cable               8D-FB
                                                 CHFCAB-002-1
                                                 CHFCAB-002-3       Sep. 22, 2016       Sep. 21, 2017
                                                 CHFCAB-002-4
      Software               ADT_Radiated_V
                                            NA                      NA                  NA
      BVADT                  8.7.08
      Antenna Tower & Turn
      Table                  NA                  NA                 NA                  NA
      CT

Note:
 1. The calibration interval of the above test instruments are 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in 10m Chamber No. F.
 3. The FCC Site Registration No. is 928149.
 4. The VCCI Site Registration No. is R-3252.
 5. The CANADA Site Registration No. is IC 7450H-1.
 6. Tested Date: Apr. 29, 2017




Report No.: FC170421E11                       Page No. 12 / 22                        Report Format Version: 6.1.2


5.3   Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited test facility.
   The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 10 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The antenna is a broadband antenna, and its height is varied from one meter to four meters above the
   ground to determine the maximum value of the field strength. Both horizontal and vertical polarizations of
   the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights from 1 meter to 4 meters and the rotatable table was turned from 0 degrees to 360 degrees to find
   the maximum reading.
e. The test-receiver system was set to quasi-peak detect function and specified bandwidth with maximum
   hold mode when the test frequency is up to 1 GHz.

Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 120kHz for
      quasi-peak detection (QP) at frequency up to 1GHz.




For the actual test configuration, please refer to the related Item – Photographs of the Test Configuration.




5.4   Supplementary Information
There is not any deviation from the test standards for the test method.




Report No.: FC170421E11                        Page No. 13 / 22                         Report Format Version: 6.1.2


5.5   Test Results

Frequency Range               |30MHz ~ 1GHz                               gaezfj‘i‘v‘i’;t';“”"“"” &   quasi—Peak (QP), 120kHz
                                                                          Environmental                  s    o
Input Power                   DC 1.5V from battery                        Conditions                  25°C, 71%RH
Tested by                     Jason Huang
Test Mode                     Mode 1

                                  Antenna Polarity & Test Distance                   : Horizontal at 10 m
                              Emission            mds              .                  Antenna       Table              Raw    Correction
 No     Frt(a&t:_'ezr;cy        Level      (dll3_:Jn\1/|/lm) M(zrg)m                   Height       Angle             Value     Factor
                              (dBuV/m)                                                   (m)      (Degree)           (dBuV)     (dB/m)
  1         187.14            19.30 QP        30.00          —10.70                    4.00 H         74              33.88     —14.58
  2         422.44            23.16 QP        37.00          —13.84                    2.00 H         10              31.34      —8.18
  3         461.99            25.94 QP        37.00          —11.06                    2.00 H        234              33.13      —7.19
  4         492.54            28.77 QP        37.00           —8.23                    2.00 H        270              35.42      —6.65
  5         593.98            24.92 QP        37.00          —12.08                    2.00 H         87              29.16      ~4.24
  6         912.55            26.97 QP        37.00          —10.03                    2.00 H        295              25.63      1.34
Remarks:
             1. Emission Level(dBuV/m)= Raw Value(dBuV) + Correction Factor(dB/m)
             2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                             — Pre—Amplifier Factor (dB)
             3. The other emission levels were very low against the limit.
             4. Margin value = Emission level — Limit value

                            Level
                           (dBuVim}
                             50

                             70

                             5n

                             50

                             ao
                             2                                                   3                         6

                             20

                             10

                              0
                            ao—         i     i     i      i          i          i        i      i     i         1
                                  30   100   200   300    400       500        600       700    800   900      1000
                                                               Frequency (MHz)




Report No.: FC170421E11                                  Page No. 14 / 22                                       Report Format Version: 6.1.2


Frequency Range               |30MHz ~ 1GHz                                 g;fi?&iuncuon * quasi—Peak (QP), 120kHz
Input Power                   DC 1.5V from battery                          Eg‘r’]';‘;?;‘sma'            25°C, 71%RH
Tested by                     Jason Huang
Test Mode                     Mode 1

                                       Antenna Polarity & Test Distance : Vertical at 10 m
                              Emission                  mss                   .         Antenna      Table          Raw        Correction
 No     Frt(a&t:_'ezr;cy        Level              (dlébn\}'}m)         M(zrg)m          Height     Angle          Value         Factor
                              (dBuV/m)                                                    (m)      (Degree)       (dBuV)         (dB/m)
  1         34.07             23.02 QP               30.00              —6.98           1.00 V          17         36.99         —13.97
  2       106.48              23.92 QP               30.00              —6.08           2.00 V          203        39.91         ~15.99
  3         128.70            23.79 QP               30.00              —6.21           1.00 V          221        37.36         —13.57
  4       213.01              20.25 QP               30.00              —9.75           1.00 V          213        35.87         —15.62
  5       494.51              2841 QP                37.00              —8.59           3.00 V          243        34.79          —6.38
  6       907.90              27.09 QP               37.00              —9.91           2.00 V          121        25.20           1.89
Remarks:
             1. Emission Level(dBuV/m)= Raw Value(dBuV) + Correction Factor(dB/m)
             2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                             — Pre—Amplifier Factor (dB)
             3. The other emission levels were very low against the limit.
             4. Margin value = Emission level — Limit value


                            Level
                           (dBuVim}
                             80

                             70

                             5n

                             50

                             40

                             30—j

                             20




                                                         i          i       i       i        i      i       i     1
                                  30   100   200       300        400     500     s00      700    s00     s00   1000
                                                                    Frequency (MHz)




Report No.: FC170421E11                                       Page No. 15 / 22                                   Report Format Version: 6.1.2


6     Radiated Emissions above 1 GHz
6.1    Limits
Emissions radiated outside of the specified bands, shall be according to the general radiated limits as
following:
                             Radiated Emissions Limits at 10 meters (dBμV/m)
  Frequencies    FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                   CISPR 22, Class A CISPR 22, Class B
      (MHz)             Class A                  Class B
    1000-3000          Avg: 49.5                Avg: 43.5              Not defined           Not defined
   Above 3000          Peak: 69.5              Peak:  63.5             Not defined           Not defined

                             Radiated Emissions Limits at 3 meters (dBμV/m)
    Frequencies  FCC 15B / ICES-003, FCC 15B / ICES-003,
                                                                     CISPR 22, Class A CISPR 22, Class B
       (MHz)            Class A                   Class B
                                                                         Avg: 56             Avg: 50
  1000-3000
                        Avg: 60                   Avg: 54                Peak: 76            Peak: 70
                       Peak: 80                  Peak: 74                Avg: 60             Avg: 54
  Above 3000
                                                                         Peak: 80            Peak: 74
Notes: 1. The lower limit shall apply at the transition frequencies.
       2. Emission level (dBuV/m) = 20 log Emission level (uV/m).
       3. As shown in 15.35(b), for frequencies above 1000MHz, the field strength limits are based on
          average detector, however, the peak field strength of any emission shall not exceed the maximum
          permitted average limits, specified above by more than 20dB under any condition of modulation.
Frequency Range (For unintentional radiators)
 Highest frequency generated or used in the device or
                                                            Upper frequency of measurement range (MHz)
      on which the device operates or tunes (MHz)
                          Below 1.705                                           30
                           1.705-108                                           1000
                           108-500                                             2000
                           500-1000                                            5000
                                                          5th harmonic of the highest frequency or 40GHz,
                          Above 1000
                                                                        whichever is lower




Report No.: FC170421E11                      Page No. 16 / 22                         Report Format Version: 6.1.2


6.2   Test Instruments
    DESCRIPTION &                                                        CALIBRATED             CALIBRATED
                                MODEL NO.               SERIAL NO.
   MANUFACTURER                                                             DATE                   UNTIL
Test Receiver
                          N9038A                    MY50010125          Apr. 15, 2017         Apr. 14, 2018
Agilent
Pre-Amplifier
                          8449B                     3008A01975          Feb. 26, 2017         Feb. 25, 2018
Agilent
Horn Antenna
                          BBHA 9120D                D123                Dec. 15, 2016         Dec. 14, 2017
SCHWARZBECK
RF Coaxial Cable          EMC104-SM-SM-11000        170209              Mar. 07, 2017         Mar. 06, 2018
RF Coaxial Cable          EMC104-SM-SM-6000         170207              Mar. 07, 2017         Mar. 06, 2018
RF Coaxial Cable          EMC104-SM-SM-2500         170206              Mar. 07, 2017         Mar. 06, 2018
Software                  ADT_Radiated_
                                                    NA                  NA                    NA
BVADT                     V8.7.08
Antenna Tower & Turn
Table                     NA                        NA                  NA                    NA
CT
Fix tool for Boresight
                          BAF-01                    5                   NA                    NA
antenna tower

 Note:
 1. The calibration interval of the above test instruments are 12 months and the calibrations are
    traceable to NML/ROC and NIST/USA.
 2. The test was performed in 10m Chamber No. F.
 3. The VCCI Site Registration No. is G-136.
 4. Tested Date: Apr. 26, 2017




Report No.: FC170421E11                       Page No. 17 / 22                          Report Format Version: 6.1.2


6.3   Test Arrangement
a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an accredited chamber
   room. The table was rotated 360 degrees to determine the position of the highest radiation.
b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted on the top
   of a variable-height antenna tower.
c. The height of antenna can be varied from one meter to four meters, the height of adjustment depends on
   the EUT height and the antenna 3dB beamwidth both, to detect the maximum value of the field strength.
   Both horizontal and vertical polarizations of the antenna are set to make the measurement.
d. For each suspected emission, the EUT was arranged to its worst case and then the antenna was tuned to
   heights and the rotatable table was turned from 0 degrees to 360 degrees to find the maximum reading.
e. The spectrum analyzer system was set to peak and average detect function and specified bandwidth with
   maximum hold mode when the test frequency is above 1 GHz.

Note: The resolution bandwidth of test receiver/spectrum analyzer is 1MHz and video bandwidth is 3MHz for
      Peak detection (PK) at frequency above 1GHz. The resolution bandwidth of test receiver/spectrum
      analyzer is 1 MHz for Average detection (AV) at frequency above 1GHz.




                                                      Ant. Tower
                                                                            1 - 4m
                                                                            Variable
         EUT&                             3m
        Support Units

                             Turn
                             Table         Absorber

          80cm



                                      Ground Plane

                                       Test Receiver




The test arrangement is in accordance with ANSI 63.4:2014. For the actual test configuration, please refer to
the related item – Photographs of the Test Configuration.




6.4   Supplementary Information


There is not any deviation from the test standards for the test method.




Report No.: FC170421E11                        Page No. 18 / 22                        Report Format Version: 6.1.2


6.5   Test Results
                                                                                Detector Function &            Peak (PK) /
Frequency Range                  1GHz ~12.5GHz                                  Bandwidth                      Averafge ()AV) 1MHz
                                                                                Environmental                         s         o
Input Power                      DC 1.5V from battery                           Conditions                     24°C, 64%RH

Tested by                        Jason Huang
Test Mode                        Mode 1

                                      Antenna Polarity & Test Distance : Horizontal at 3 m
                                 Emission                i                       .      Antenna               Table               Raw       Correction
 No     Frt(a&t:_'ezr;cy           Level           ( dléijn\}'/lm)         M(zlég)m      Height              Angle               Value        Factor
                                 (dBuV/m)                                                  (m)              (Degree)            (dBuV)        (dB/m)
  1      1201.12                 40.90 PK             74.00                —33.10       1.00    H             60                    44.50     —3.60
  2      1201.12                 28.50 AV             54.00                —25.50       1.00    H             60                    32.10     —3.60
  3      1649.87                 44.50 PK             74.00                —29.50       2.00    H             150                   45.10     —0.60
  4      1649.87                 30.70 AV             54.00                —23.30       2.00    H             150                   31.30     —0.60
  5      2080.00                 45.20 PK             74.00                —28.80       1.00    H             26                    43.30      1.90
  6      2080.00                 32.50 AV             54.00                —21.50       1.00 H                 26                   30.60     1.90
  7      3100.75                 48.00 PK             74.00                —26.00       2.00 H                360                   43.20     4.80
  8      3100.75                 35.10 AV             54.00                —18.90       2.00    H             360                   30.30     4.80
  9      3723.62                 48.90 PK             74.00                —25.10       1.00    H              15                   41.80     7.10
 10      3723.62                 36.30 AV             54.00                —17.70       1.00    H              15                   29.20     7.10
 11      4212.62                 52.00 PK             74.00                —22.00       2.00    H             360                   43.40     8.60
 12      4212.62                 38.80 AV             54.00                ~15.20       2.00    H             360                   30.20     8.60
Remarks:
             1. Emission Level(dBuV/m)= Raw Value(dBuV) + Correction Factor(dB/m)
             2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                             — Pre—Amplifier Factor (dB)
             3. The other emission levels were very low against the limit.
             4. Margin value = Emission level — Limit value

                             Level
                           (dBu/im}
                            20

                            50

                            70

                            50

                            50

                            40

                            30

                            20

                            10

                             0 1000           i            i           i            i     i           i         i           i
                              1000 2000     4000        €000         2000       10000   12000       14000     16000       18000
                                                                     Frequency (MHz)




Report No.: FC170421E11                                          Page No. 19 / 22                                          Report Format Version: 6.1.2


                                                                           Detector Function &             Peak (PK) /
Frequency Range                 |1GHz ~ 12.5GHz                            Beeaoin                         Avera;e  ()AV) 1MHz
                                                                           Environmental                          s         o
Input Power                     DC 1.5V from battery                      Conditions                       24°C, 64%RH

Tested by                       Jason Huang
Test Mode                       Mode 1

                                         Antenna Polarity & Test Distance : Vertical at 3 m
        Frequency               Emission               Limit           Margin       Antgnna               Table               Raw       Correction
 No       (MHz)                   Level              (dBuV/m)           (dB)         Height              Angle               Value        Factor
                                (dBuV/m)                                               (m)              (Degree)            (dBuV)        (dB/m)
  1       1094.87               41.70 PK              74.00            —32.30       2.00 V                360                   46.70     —5.00
 2       1094.87                27.70    AV           54.00            —26.30       2.00    V             360                   32.70     —5.00
 3       1397.89                48.40    PK           74.00            —25.60       2.00    V             170                   50.50     —2.10
 4       1397.89                29.00    AV           54.00            —25.00       2.00    V             170                   31.10     —2.10
 5       1769.25                43.40    PK           74.00            —30.60       1.00    V             196                   43.30     0.10
 6       1769.25                30.60    AV           54.00            —23.40       1.00    V             196                   30.50     0.10
 7       2127.50                46.50    PK           74.00            —27.50       1.00    V             221                   44.10     240
 8       2127.50                32.40    AV           54.00            —21.60       1.00    V             221                   30.00     240
 9       3217.62                49.00    PK           74.00            —25.00       1.00    V             101                   43.60     5.40
 10      3217.62                35.70    AV           54.00            —18.30       1.00    V             101                   30.30     5.40
 11      3721.25                49.00    PK           74.00            —25.00       2.00    V             360                   42.00     7.00
 12      3721.25                36.40    AV           54.00            —17.60       2.00    V             360                   29.40     7.00
Remarks:
            1. Emission Level(dBuV/m)= Raw Value(dBuV) + Correction Factor(dB/m)
            2. Correction Factor(dB/m) = Antenna Factor (dB/m) + Cable Factor (dB)
                                            — Pre—Amplifier Factor (dB)
            3. The other emission levels were very low against the limit.
            4. Margin value = Emission level — Limit value

                            Level
                          (dBu/im}
                           20

                           l

                           70

                           5o

                           50

                           40

                           30

                           20

                           10

                            0 100               1         1        i         i        i           i         i           1
                             1000 2000        4000      6000     5000      10000    12000       14000     16000       15000
                                                                  Frequency (MHz)




Report No.: FC170421E11                                        Page No. 20 / 22                                        Report Format Version: 6.1.2


7    Pictures of Test Arrangements
Please refer to the attached file (Test Setup Photo).




Report No.: FC170421E11                        Page No. 21 / 22   Report Format Version: 6.1.2


Appendix – Information on the Testing Laboratories


We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited and
approved according to ISO/IEC 17025.

If you have any comments, please feel free to contact us at the following:

Linko EMC/RF Lab                                       Hsin Chu EMC/RF/Telecom Lab
Tel: 886-2-26052180                                    Tel: 886-3-6668565
Fax: 886-2-26051924                                    Fax: 886-3-6668323


Hwa Ya EMC/RF/Safety Lab
Tel: 886-3-3183232
Fax: 886-3-3270892


Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com

The address and road map of all our labs can be found in our web site also.



--- END ---




Report No.: FC170421E11                        Page No. 22 / 22                      Report Format Version: 6.1.2



Document Created: 2017-10-24 14:45:20
Document Modified: 2017-10-24 14:45:20

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC