RF Exposure Info (MPE).pdf

FCC ID: JNZA00080

RF Exposure Info

Download: PDF
FCCID_4051250

                                                           RF Exposure Report

                       Report No.: SA181004E03

                            FCC ID: JNZA00080

                       Test Model: A-00080

                 Received Date: Oct. 04, 2018

                         Test Date: Oct. 16, 2018

                     Issued Date: Oct. 24, 2018


                         Applicant: LOGITECH FAR EAST LTD.

                          Address: #2 Creation Rd. 4, Science-Based Ind. Park Hsinchu Taiwan, R.O.C.


                        Issued By: Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch
                                   Hsin Chu Laboratory
                    Lab Address: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                                 Taiwan R.O.C.
            Test Location: E-2, No.1, Li Hsin 1st Road, Hsinchu Science Park, Hsinchu City 300,
                           Taiwan R.O.C.
       FCC Registration /
                           723255 / TW2022
      Designation Number:




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product
unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you
provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific
mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification. The report
must not be used by the client to claim product certification, approval, or endorsement by any government agencies.
Report No.: SA181004E03                                              Page No. 1 / 6                                             Report Format Version: 6.1.1
Reference No.: 181004E03


                                                                  Table of Contents
Release Control Record .................................................................................................................................. 3
1        Certificate of Conformity ...................................................................................................................... 4
2        Evaluation Result .................................................................................................................................. 5
3        SAR Test Exclusion Thresholds .......................................................................................................... 6
4        Conclusion ............................................................................................................................................ 6




Report No.: SA181004E03                                             Page No. 2 / 6                                             Report Format Version: 6.1.1
Reference No.: 181004E03


                                           Release Control Record


Issue No.              Description                                         Date Issued
SA181004E03            Original release.                                   Oct. 24, 2018




Report No.: SA181004E03                       Page No. 3 / 6        Report Format Version: 6.1.1
Reference No.: 181004E03


1    Certificate of Conformity


            Product: Wireless Dongle

              Brand: logitech G

         Test Model: A-00080

    Sample Status: ENGINEERING SAMPLE

          Applicant: LOGITECH FAR EAST LTD.

          Test Date: Oct. 16, 2018

         Standards: FCC Part 2 (Section 2.1093)

                           KDB 447498 D01 General RF Exposure Guidance v06
                           IEEE C95.1-1992



The above equipment has been tested by Bureau Veritas Consumer Products Services (H.K.) Ltd.,
Taoyuan Branch, and found compliance with the requirement of the above standards. The test record, data
evaluation & Equipment Under Test (EUT) configurations represented herein are true and accurate accounts
of the measurements of the sample’s EMC characteristics under the conditions specified in this report.




      Prepared by :                                              ,   Date:      Oct. 24, 2018
                                Phoenix Huang / Specialist




     Approved by :                                               ,   Date:      Oct. 24, 2018
                                  May Chen / Manager




Report No.: SA181004E03                         Page No. 4 / 6                       Report Format Version: 6.1.1
Reference No.: 181004E03


2       Evaluation Result


Following FCC KDB 447498 D01 “General SAR test exclusion guidance”

The corresponding SAR Exclusion Threshold condition, listed below:

1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
    mm are determined by:
    [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)]
    ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
                                                                 .
                                                                                          .
                                                                      The test exclusions are applicable only
          when the minimum test separation distance is ≤ 50 mm and for transmission frequencies between 100
          MHz and 6 GHz. When the minimum test separation distance is < 5 mm, a distance of 5 mm is applied
          to determine SAR test exclusion.

2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test exclusion threshold is
    determined according to the following:
    a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)·( f(MHz)/150)] mW, at 100MHz to
        1500 MHz
    b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at > 1500 MHz and ≤ 6
         GHz

3) At frequencies below 100 MHz, the following may be considered for SAR test exclusion.
    a) The threshold at the corresponding test separation distance at 100 MHz in step 2) is multiplied by [1 +
        log(100/f(MHz))] for test separation distances > 50 mm and < 200 mm.
    b) The threshold determined by the equation in a) for 50 mm and 100 MHz is multiplied by ½ for test
         separation distances ≤ 50 mm.
    c) SAR measurement procedures are not established below 100 MHz. When SAR test exclusion cannot
         be applied, a KDB inquiry is required to determine SAR evaluation requirements for any test results to
         be acceptable.




Report No.: SA181004E03                          Page No. 5 / 6                         Report Format Version: 6.1.1
Reference No.: 181004E03


                                                                                                                                                                  C
                                                                                                                                                                 ICoGent




3        SAR Test Exclusion Thresholds

                                                                                                                                  Avg. P
                   Channel                                          Frequency (MHz)                                     imw)        eCE                  (dBm)

                           1                                              2403.35                                       2.312                            3.64
                          19                                              2439.35                                       2.109                            3.24
                          38                                              2477 .35                                      1.928                            2.85


SAR Test Exclusion Thresholds

                                               Max Avg.             *Max Time             Moslimei          40 tgst         l t?st            1—g SAR test
        Frequency                                                                           Avg.           separation       exclusion                .
                                                    Power           Avg. Power                               .                     ;            exclusion        Result
             (MHz)                                  (dBm)              (dBm)                Power           distance       calculation         thresholds
                                                                                             (mW)                (mm)      value®N?"=2
2403.35 ~ 2477.35                                   3.64               —0.10                 0.977                5             0.3029               3           Pass
    Note:               1. Calculate SAR test exclusion thresholds from condition "1" formulas.
                        2. *Time Avg. Power= Avg. Power+Duty factor



Maximum duty cycle under normal use condition:
                                                                                                     Tx on                        Tx total
                                                                                                      (ms)                         (ms)             Duty Factor (dB)
                                       Duty Cycle
                                                                                                         1.913                     4.522                   —3.74
                                                                    Duty Factor =10 * log(Tx on / Tx total)


 [ KepightSpectram Analzer— Suept 54

 [Eluchsiercreie                                                     Aug Type: Voltage
                               NeE     PNO.ract «>= Trig: FreeRun
                                       IFGaintigh    #Atien: 0 dB

                Ref —20.00 dBm




    Center 2473350000 GHz
    Res BW 8 MHz          lcoc o                        Sweep 20.27 ms (8001 pts)
    w wooe To                                roncrion roncnownom FuNCflGN vaue >
     l az1|     _
                   3917 ms       $0.24 dBm ___
                mm 248      lim)    248 aB|_______|_______________|
                   3.917 ms      #0.244Bm| _______|______|_________|
                |nnpeEiep                                                       =




4        Conclusion


Since Source—base time average power is below SAR test exclusion power thresholds, the SAR evaluation is
not required.


——— END ———

Report No.: SA181004E03                                                                  Page No. 6/ 6                                       Report Format Version: 6.1.1



Document Created: 2019-05-03 15:10:12
Document Modified: 2019-05-03 15:10:12

© 2024 FCC.report