Test Report

FCC ID: JM7-IGWT-662002

Test Report

Download: PDF
FCCID_329854

                                                                   UL International EMC Services
                                                                   333 Pfingsten Road
                                                                   Northbrook, Illinois 60062-2096
                                                                   (800) 873-8536
                                                                   Fax No. (847) 272-8864
                                                                   http://www.ul.com/emc/




December 03, 2002


Accutec a Div.of
Innovative Control Systems, Inc.
Attn: Mr. Mark Kieckhefer
N27 W23910-A Paul Rd.
Pewaukee, WI 53072

UL Reference:          File MC1670, Project 02NK45212

Subject:               EMC Test and Measurement Report for
                       Model TAG, Infant Security Module

Dear Mr. Kieckhefer:

We have provided with this letter your EMC Test Report for the above referenced model. The
product was determined to comply with the requirements noted in the report.

Please review the attached report and direct any questions or comments to me. Samples will be
returned to your attention.

We appreciate your interest in UL’s EMC Services, and encourage you to contact us in the
future should you need EMC test services. This closes Project 02NK45212.

Best regards,                               Reviewed by:




Mike Ehas (Ext 42351)                       Jack Steiner
EMC Lead Engineering Associate              Engineering Group Leader
International EMC Services                  International EMC Services


                                                                     FCC ID: JM7-IGWT-662002



                         EMC – TEST REPORT
   Issue Date: December 03, 2002

                                     √     EMISSIONS
                                           IMMUNITY
Test Report File No.            : MC1670
Project No.                     : 02NK45212

Model / Type                    : TAG
Kind of Product                 : Infant Security Module

Applicant                       : Accutec a Div. of
                                   Innovative Control Systems, Inc.
License Holder                  : Accutec a Div. of
                                  Innovative Control Systems, Inc.
Address                         : N27 W23910-A Paul Rd
                                : Pewaukee, WI 53072

Manufacturer                    : Same as Applicant
                                :
                                :

Test Result                     : COMPLIANT
This report without appendices consists of 10 pages. Appendix A contains test photos,
Appendix B contains original test data and Appendix C contains sample calculations.

The data contained in this report reflects only the items tested in the configurations and
mode of operations described. An attempt has been made to arrange the EUT, with the
equipment provided, into a test configuration which maximizes the observed emissions of
the EUT while simulating, as close as practical, a typical end-use installation. The photos
and data provided in this report document that configuration.

          Underwriters Laboratories Inc. authorizes the above company to reproduce
                     this report provided it is reproduced in its entirety.

      Underwriters Laboratories Inc.      333 Pfingsten Rd. Northbrook, IL 60062
                                                                Fax: (847) 272-8864

 File: MC1670   Project: 02NK45212                                          Page 1 of 10
UL International EMC Services            www.ul.com/emc               (800) USE UL EMC


                                                                       FCC ID: JM7-IGWT-662002




                               REPORT DIRECTORY


SECTION TITLE


GENERAL
1.0            General Product Description
1.1            Model Differences
1.2            Environmental Conditions in Test Lab
1.3            Calibration Details of Equipment Used for Measurement
1.4            EUT (Equipment Under Test) Configuration
1.5            EUT Operating Mode
1.6            Device Modifications

EMISSIONS
2.0       Emissions Test Regulations
                 Conducted Voltage
                 Radiated Electric Field Emissions
                 Band Edge Measurement

IMMUNITY
3.0      Immunity Test Regulations

CONCLUSION
4.0      General Remarks
4.1      Summary

APPENDICIES
A         Test Setups (Photos, Diagrams and Drawings)
B         Test Data
C         Sample Calculations
D         Block Diagram of the Measurement System




File: MC1670   Project: 02NK45212                                             Page 2 of 10
UL International EMC Services            www.ul.com/emc                 (800) USE UL EMC


                                                                       FCC ID: JM7-IGWT-662002


1.0    GENERAL PRODUCT DESCRIPTION

       The Equipment Under Test (EUT) is an infant security module. The module is warn by
       the infant and if the module is removed or if the infant is passed through an area with
       doorway modules active (transmitting 132 kHz signal), the TAG then transmits a 418
       MHz signal to a central receiving module which is in turn connected to the graphical
       display system or Multiplexer.

       1.0.1    Equipment Mobility:

                Floor Standing. See Appendix A for configuration photos.

       1.0.2    Test Voltage and Frequency:

                       Voltage (V)            Frequency (Hz)
                           1.5                     DC




1.1    MODEL DIFFERENCES

       Any other model(s) represented by the models tested in this investigation will be
       documented by the manufacturer.


1.2    ENVIRONMENTAL CONDITIONS IN TEST LAB

       Temperature:                  20-25 °C
       Relative Humidity:            30-60% RH
       Atmospheric Pressure:         860-1060 mbar


1.3    CALIBRATION OF EQUIPMENT USED FOR MEASUREMENT

       All test equipment and test accessories are calibrated on a regular basis. The
       maximum time between calibrations is one year or what is recommended by the
       manufacturer, whichever is less.

       All test equipment calibrations are traceable to the National Institute of Standards
       and Technology (NIST), therefore, all test data recorded in this report is traceable
       to NIST.




 File: MC1670   Project: 02NK45212                                            Page 3 of 10
UL International EMC Services              www.ul.com/emc               (800) USE UL EMC


                                                                     FCC ID: JM7-IGWT-662002


1.4    EUT CONFIGURATION(s)

       See Appendix A for individual set-up configuration(s). In addition to the EUT, the
       following peripheral devices and/or cables were connected during the
       measurement:


                Device         Manufacturer         Model           Serial #          FCC ID
                 N/A




                Cable       Manufacturer   Length      Type         Shield           Shield
                                                                    Type          Termination
                 N/A




1.5    EUT OPERATING MODE(s)

       The equipment under test was operated during the measurements under the
       following conditions:

       Testing was conducted in the transmit mode. The device does not operate in the standby
       mode until it receives a 132 kHz signal from a doorway module or the strap has been
       removed from the infant. Measurements were maximized with the device situated in the
       3 orthogonal axes. Testing was conducted with a new battery.


1.6    DEVICE MODIFICATIONS

       The following modifications were necessary for compliance:

       None




 File: MC1670     Project: 02NK45212                                           Page 4 of 10
UL International EMC Services              www.ul.com/emc              (800) USE UL EMC


                                                                     FCC ID: JM7-IGWT-662002


      2.0      EMISSIONS TEST REGULATIONS


      Emissions testing was performed according to the following regulations:


      47 CFR Part 15 Subpart C: 2000 + ANSI C63.4 – 1992
            47 CFR Part 15.209(a)(b)(c)(d)
            47 CFR Part 15.231(a)(b)(c)

      This device transmits continuously when activated. Per 15.231(a)(4), A safety device
      may operate continuously during the pendency of the alarm.




File: MC1670   Project: 02NK45212                                            Page 5 of 10
UL International EMC Services            www.ul.com/emc                (800) USE UL EMC


                                                                     FCC ID: JM7-IGWT-662002


      RADIATED ELECTRIC FIELD EMISSIONS, 10kHz to 30MHz

      Test Location
      10 Meter Semi-Anechoic Chamber

      UL Procedure
      3014ANBK-LPG-002

      Test Instruments
      Spectrum Analyzer / Quasi-peak Adapter / Preamplifier / Preselector
      Hewlett Packard Model 8566B Spectrum Analyzer
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Model 85650A Quasi-peak Adapter
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Model 85685A RF Preselector        No. EMC4015
      Last Cal. 05/08/02   Next Cal. 05/08/03

      Antennas
      Solar Electronics., Loop Sensor, Model 7334-1
      Last Cal. 03/07/02     Next Cal. 03/07/03

      Frequency Range of Measurement
      10kHz-30MHz

      Measurement Distance
      10 meters

      Test Results
      The requirements are:
             MET

      Remarks
      See App. B for complete test results.

      Measurements were check in both the Horizontal and Vertical polarities. Only the
      antenna polarity with the highest reading was used for final measurements.




File: MC1670   Project: 02NK45212                                           Page 6 of 10
UL International EMC Services             www.ul.com/emc              (800) USE UL EMC


                                                                     FCC ID: JM7-IGWT-662002


      RADIATED ELECTRIC FIELD EMISSIONS, 30MHz to 1000MHz

      Test Location
      10 Meter Semi-Anechoic Chamber

      UL Procedure
      3014ANBK-LPG-002

      Test Instruments
      Spectrum Analyzer / Quasi-peak Adapter / Preamplifier / Preselector
      Hewlett Packard Model 8566B Spectrum Analyzer
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Model 85650A Quasi-peak Adapter
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Miteq AM-3A-000110-N Preamp        No. FCA4003, EMC4016, EMC4151
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Model 85685A RF Preselector        No. EMC4015
      Last Cal. 05/08/02   Next Cal. 05/08/03

      Antennas
      Chase EMC Ltd., Biconical Antenna Model VBA6106A                 S/N 1246
      Last Cal. 05/25/02  Next Cal. 05/25/03
      Chase EMC Ltd., Log Periodic Antenna Model UPA6108               S/N 1120
      Last Cal. 05/25/02  Next Cal. 05/25/03

      Frequency Range of Measurement
      30MHz-1000MHz

      Measurement Distance
      3 meters

      Test Results
      The requirements are:
             MET

      Remarks
      See App. B for complete test results.

      Preliminary measurements (peak scans) were done by rotating the turntable 360° and at
      multiple antenna heights (1 meter and 3 meters).

      If necessary, final measurements were conducted using a quasi-peak detector. These
      emissions were maximized by rotating the turntable 360° and positioning the receive
      antenna from 1 to 4 meters in height.




File: MC1670   Project: 02NK45212                                           Page 7 of 10
UL International EMC Services             www.ul.com/emc              (800) USE UL EMC


                                                                     FCC ID: JM7-IGWT-662002


      RADIATED ELECTRIC FIELD EMISSIONS, 1000MHz to 5000MHz

      Test Location
      10 Meter Semi-Anechoic Chamber

      UL Procedure
      3014ANBK-LPG-002

      Test Instruments
      Spectrum Analyzer / Preamplifier / Preselector
      Hewlett Packard Model 8566B Spectrum Analyzer
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Model 8499 Preamplifier     No. EMC4201
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Model 85685A RF Preselector         No. EMC4015
      Last Cal. 05/08/02   Next Cal. 05/08/03

      Antennas
      EMCO., Double Ridge Guide Antenna Model 3115              S/N 3032
      Last Cal. 05/25/02 Next Cal. 05/25/03

      Frequency Range of Measurement
      1000MHz-5000MHz

      Measurement Distance
      3 meters

      Test Results
      The requirements are:
             MET

      Remarks
      See App. B for complete test results.

      Preliminary measurements (peak scans) were done by rotating the turntable 360° and at
      multiple antenna heights (1 meter and 3 meters).

      If necessary, final measurements were conducted using a quasi-peak detector. These
      emissions were maximized by rotating the turntable 360° and positioning the receive
      antenna from 1 to 4 meters in height.




File: MC1670   Project: 02NK45212                                           Page 8 of 10
UL International EMC Services             www.ul.com/emc              (800) USE UL EMC


                                                                    FCC ID: JM7-IGWT-662002


      RADIATED EMISSIONS / BAND EDGE MEASUREMENT


      Test Location
      10 Meter Semi-Anechoic Chamber

      UL Procedure
      3014ANBK-LPG-002

      Test Instruments
      Spectrum Analyzer / Quasi-peak Adapter / Preamplifier / Preselector
      Hewlett Packard Model 8566B Spectrum Analyzer
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Model 85650A Quasi-peak Adapter
      Last Cal. 05/08/02   Next Cal. 05/08/03
      Model 85685A RF Preselector        No. EMC4015
      Last Cal. 05/08/02   Next Cal. 05/08/03

      Antennas
      Chase EMC Ltd., Log Periodic Antenna Model UPA6108               S/N 1120
      Last Cal. 05/25/02  Next Cal. 05/25/03

      Frequency Range of Measurement
      418 MHz

      Measurement Distance
      3 meters

      Test Results
      The requirements are:
             MET

      Remarks
      See App. B for complete test results.




File: MC1670   Project: 02NK45212                                           Page 9 of 10
UL International EMC Services             www.ul.com/emc              (800) USE UL EMC


                                                                      FCC ID: JM7-IGWT-662002


3.0    IMMUNITY TEST REGULATIONS

       Immunity testing was not required nor performed.



4.0    GENERAL REMARKS

       Sample Receipt Date :         October 24, 2002

       Test Dates
                       Start   :     October 24, 2002
                       End     :     October 31, 2002


4.1    SUMMARY

       The requirements according to the technical regulations are:

       MET



Underwriters Laboratories Inc.
333 Pfingsten Road
Northbrook, IL 60062 USA

FCC Site Number: 31040/SIT 1300F2



Best regards,                                Reviewed by:




Mike Ehas (Ext 42351)                        Jack Steiner
EMC Lead Engineering Associate               Engineering Group Leader
International EMC Services                   International EMC Services




 File: MC1670   Project: 02NK45212                                          Page 10 of 10
UL International EMC Services             www.ul.com/emc               (800) USE UL EMC


                                                   FCC ID: JM7-IGWT-662002




                                  APPENDIX A

                                    PHOTOS




File MC1670   Project 02NK45212                         Page A1 of A2
UL International EMC Services     www.ul.com/emc    (800) USE UL EMC


                                                      FCC ID: JM7-IGWT-662002




                                                   Radiated Emissions

                                                     TAD Rx Mode
                                                     TAG TX Mode

                                                         Fig. 2




File MC1670   Project 02NK45212                            Page A2 of A2
UL International EMC Services     www.ul.com/emc       (800) USE UL EMC


                                                           FCC ID: JM7-IGWT-662002


                                            APPENDIX B

                                            TEST DATA




      EMISSIONS

                     Radiated Electric Field Emissions




File MC3486   Project 02NK45212              /              Page B1 of B13

UL International EMC Services            www.ul.com/emc   (800) USE UL EMC


                                                                        FCC ID: JM7-IGWT-662002




                         UNDERWRITERS LABORATORIES INC.
                                Radiated Emissions

                                                                   Date Tested: 24 October 2002

Manufacturer                 :    Accutech
Equipment Under Test         :    TAG (Tx activation mode)
Requirement                  :    CFR 47, Part 15
Detection Mode               :    Quasi-peak (qp) and Average (Av)
Bandwidth                    :    200 Hz (10 kHz-150 kHz), 9 kHz (150 kHz-30 MHz)
Measurement Distance         :    10 meter
Antenna Type                 :    10 kHz – 30 MHz Loop Sensor




File MC3486   Project 02NK45212                /                         Page B2 of B13

UL International EMC Services              www.ul.com/emc             (800) USE UL EMC


                                                            FCC ID: JM7-IGWT-662002



 ACCUTECH
 BABY TAG ACTIVE
 BATTERY

      Test     Meter     Gain/Loss Transducer Level Limit:1
No. Frequency Reading     Factor     Factor dB[uVolts/meter]
     [MHz]     [dB(uV)]     [dB]      [dB]
===================================================================
Range: 1 .01 - .15MHz --------------------------------------------
1 .011          39.67 pk     0         20.53     60.2    105.86
   Azimuth:191   Height:100 Horz     Margin [dB]         -45.66

Range: 2 .15 - 30MHz ---------------------------------------------
2 .1997         42.99 pk     .01       12.1      55.1    80.69
   Azimuth:184   Height:100 Horz     Margin [dB]         -25.59

LIMIT 1: CFR 47 PART 15 C 10M DISTANCE

pk - Peak detector




File MC3486   Project 02NK45212          /                   Page B3 of B13

UL International EMC Services     www.ul.com/emc          (800) USE UL EMC


                                                                         FCC ID: JM7-IGWT-662002




                         UNDERWRITERS LABORATORIES INC.
                                Radiated Emissions

                                                                    Date Tested: 30 October 2002

Manufacturer                 :    Accutech
Equipment Under Test         :    TAG (Tx activation mode, Horizontal position)
Requirement                  :    CFR 47, Part 15, Class B
Detection Mode               :    Quasi-peak (qp) and Average (Av)
Bandwidth                    :    120 kHz
Measurement Distance         :    3 meters
Antenna Type                 :    30 - 300 MHz, Biconical
                                  300 - 1000 MHz, Log-Periodic




File MC3486   Project 02NK45212                 /                         Page B4 of B13

UL International EMC Services               www.ul.com/emc             (800) USE UL EMC


                                                             FCC ID: JM7-IGWT-662002



FUNDAMENTAL FREQUENCY = 417.9123
FUNDAMENTAL FREQUENCY LIMIT = 80.28dBuV/m

 Accutech
 BABY TAG - HORIZONTAL POSITION
 Internal Battery
 RED: HORIZONTAL GRN: VERTICAL

  Test     Meter     Gain/Loss Transducer Level Limit:1         2
Frequency Reading     Factor     Factor dB[uVolts/meter]
 [MHz]     [dB(uV)]     [dB]      [dB]
======================================================================
Range: 4 300 - 1000MHz
417.9119   42.3 qp       2.1       16.9      61.3            80.28
Azimuth: 3    Height:200 Horz         Margin [dB]:           -28.98

417.9123   47.15 qp     2.1       16.9      66.15             80.28
Azimuth: 248 Height:138 Vert         Margin [dB]:             -25.13

438.0933   22.99 qp     2.2       17.4      42.59   46        60.7
Azimuth: 150 Height:182 Horz         Margin [dB]:   -3.41     -18.11

438.0668   26.34 qp     2.2       17.4      45.94   46        60.7
Azimuth: 254 Height:139 Vert         Margin [dB]:   -.06      -14.76

835.8479   22.45 qp      3.5      23.3      49.25   46        61.9
Azimuth: 61   Height:106 Horz        Margin [dB]:   3.25      -12.65

835.8497   24.71 qp     3.5       23.3      51.51   46        61.9
Azimuth: 212 Height:145 Vert         Margin [dB]:   5.51      -10.39


LIMIT 1: CFR 47 PART 15 C 3M DISTANCE
LIMIT 2: SPURIOUS EMISSIONS LIMIT

qp - Quasi-Peak detector




File MC3486   Project 02NK45212         /                     Page B5 of B13

UL International EMC Services     www.ul.com/emc            (800) USE UL EMC


                                                                         FCC ID: JM7-IGWT-662002


                          UNDERWRITERS LABORATORIES INC.
                                 Radiated Emissions

                                                                    Date Tested: 30 October 2002

Manufacturer                 :    Accutech
Equipment Under Test         :    TAG (Tx activation mode, Vertical position)
Requirement                  :    CFR 47, Part 15, Class B
Detection Mode               :    Quasi-peak (qp) and Average (Av)
Bandwidth                    :    120 kHz
Measurement Distance         :    3 meters
Antenna Type                 :    30 - 300 MHz, Biconical
                                  300 - 1000 MHz, Log-Periodic




File MC3486   Project 02NK45212                 /                         Page B6 of B13

UL International EMC Services               www.ul.com/emc             (800) USE UL EMC


                                                             FCC ID: JM7-IGWT-662002




 Accutech
 BABY TAG - VERTICAL POSITION
 Internal Battery
 RED: HORIZONTAL GRN: VERTICAL

  Test     Meter     Gain/Loss Transducer Level Limit:1         2
Frequency Reading     Factor     Factor dB[uVolts/meter]
 [MHz]     [dB(uV)]     [dB]      [dB]
======================================================================
Range: 3 300 - 1000MHz
417.924    43.1 qp       2.1       16.9      62.1             80.28
Azimuth: 131 Height:100 Horz          Margin [dB]:            -28.18

417.9161   48.94 qp      2.1      16.9      67.94             80.28
Azimuth: 90   Height:142 Vert        Margin [dB]:             -22.34

439.5412   33.6 qp      2.2       17.5      53.3    46        60.8
Azimuth: 274 Height:116 Vert         Margin [dB]:   7.3       -7.5

439.5657   30.64 qp     2.2       17.5      50.34   46        60.8
Azimuth: 147 Height:103 Horz         Margin [dB]:   4.34      -10.46

835.861    32.44 qp      3.5      23.3      59.24   46        61.9
Azimuth: 59   Height:102 Horz        Margin [dB]:   13.24     -2.66

835.8683   26.63 qp     3.5       23.3      53.43   46        61.9
Azimuth: 209 Height:238 Vert         Margin [dB]:   7.43      -8.47


LIMIT 1: CFR 47 PART 15 C 3M DISTANCE
LIMIT 2: SPURIOUS EMISSIONS LIMIT

qp - Quasi-Peak detector




File MC3486   Project 02NK45212         /                     Page B7 of B13

UL International EMC Services     www.ul.com/emc            (800) USE UL EMC


                                                                        FCC ID: JM7-IGWT-662002



                         UNDERWRITERS LABORATORIES INC.
                                Radiated Emissions

                                                                   Date Tested: 31 October 2002

Manufacturer                 :    Accutech
Equipment Under Test         :    TAG (Tx Mode, Horizontal position)
Requirement                  :    CFR 47, Part 15, Class B
Detection Mode               :    Quasi-peak (qp) and Average (Av)
Bandwidth                    :    120 kHz
Measurement Distance         :    3 meters
Antenna Type                 :    1000 - 5000 MHz, Horn




File MC3486   Project 02NK45212                /                         Page B8 of B13

UL International EMC Services              www.ul.com/emc              (800) USE UL EMC


                                                               FCC ID: JM7-IGWT-662002




 Accutech
 TAG (Horizontal Orientation)
 TX Mode
 Internal Battery
 Red:Horizontal Green:Vertical

      Test     Meter     Gain/Loss Transducer Level Limit:1         2
No. Frequency Reading     Factor     Factor dB[uVolts/meter]
     [MHz]     [dB(uV)]     [dB]      [dB]
===========================================================================
Range: 3 1000 - 5000MHz ------------------------------------------------------
1 1252.126      69.91 pk     -55.37    25.86     40.4    53.97    61.93
   Azimuth:342   Height:100 Horz     Margin [dB]         -13.57   -21.53
2 1670.335      74.33 pk     -55.58    27.52     46.27   53.97    61.93
   Azimuth:183   Height:100 Horz     Margin [dB]         -7.7     -15.66
4 2506.753      64.65 pk     -52.37    30.61     42.89   53.97    61.93
   Azimuth:315   Height:100 Horz     Margin [dB]         -11.08   -19.04
6 3343.172      61.82 pk     -51.84    32.53     42.51   53.97    61.93
   Azimuth:302   Height:100 Horz     Margin [dB]         -11.46   -19.42

Range: 3 1000 -    5000MHz ------------------------------------------------------
3 2088.544         68.61 pk     -53.48    29.37     44.5    53.97    61.93
   Azimuth:329      Height:100 Vert     Margin [dB]         -9.47    -17.43
5 2924.962         61.9 pk      -51.58    31.36     41.68   53.97    61.93
   Azimuth:209      Height:100 Vert     Margin [dB]         -12.29   -20.25
7 3761.381         68.97 pk     -51.98    33.89     50.88   53.97    61.93
   Azimuth:4        Height:100 Vert     Margin [dB]         -3.09    -11.05
8 4179.59          67.05 pk     -52.91    34.41     48.55   53.97    61.93
   Azimuth:196      Height:100 Vert     Margin [dB]         -5.42    -13.38
9 4597.799         60.82 pk     -52.42    34.13     42.53   53.97    61.93
   Azimuth:129      Height:100 Vert     Margin [dB]         -11.44   -19.4

LIMIT 1: CFR 47 Part 15       Class B 3m
LIMIT 2: SPURIOUS LIMIT

pk - Peak detector




File MC3486   Project 02NK45212            /                    Page B9 of B13

UL International EMC Services          www.ul.com/emc        (800) USE UL EMC


                                                                          FCC ID: JM7-IGWT-662002


                         UNDERWRITERS LABORATORIES INC.
                                Radiated Emissions

                                                                     Date Tested: 31 October 2002

Manufacturer                 :    Accutech
Equipment Under Test         :    TAG (Tx Mode, Vertical position)
Requirement                  :    CFR 47, Part 15, Class B
Detection Mode               :    Quasi-peak (qp) and Average (Av)
Bandwidth                    :    120 kHz
Measurement Distance         :    3 meters
Antenna Type                 :    1000 - 5000 MHz, Horn




File MC3486   Project 02NK45212                /                          Page B10 of B13

UL International EMC Services               www.ul.com/emc             (800) USE UL EMC


                                                            FCC ID: JM7-IGWT-662002



 Accutech
 TAG (Vertical Orientation)
 TX Mode
 Internal Battery
 Red:Horizontal Green:Vertical

      Test     Meter     Gain/Loss Transducer Level Limit:1         2
No. Frequency Reading     Factor     Factor dB[uVolts/meter]
     [MHz]     [dB(uV)]     [dB]      [dB]
===========================================================================
Range: 3 1000 - 5000MHz ------------------------------------------------------
1 1252.126      73.73 pk     -55.37    25.86     44.22   53.97    60.2
   Azimuth:298   Height:102 Vert     Margin [dB]         -9.75    -15.98
2 1670.335      73.18 pk     -55.58    27.52     45.12   53.97    60.2
   Azimuth:298   Height:102 Vert     Margin [dB]         -8.85    -15.08
3 2088.544      70.63 pk     -53.48    29.37     46.52   53.97    60.2
   Azimuth:331   Height:102 Vert     Margin [dB]         -7.45    -13.68
4 2506.753      68.62 pk     -52.37    30.61     46.86   53.97    60.2
   Azimuth:317   Height:102 Vert     Margin [dB]         -7.11    -13.34
5 2924.962      70.14 pk     -51.58    31.36     49.92   53.97    60.2
   Azimuth:48    Height:102 Vert     Margin [dB]         -4.05    -10.28
6 3343.172      60.11 pk     -51.84    32.53     40.8    53.97    60.2
   Azimuth:102   Height:102 Vert     Margin [dB]         -13.17   -19.4
7 3761.381      65.99 pk     -51.98    33.89     47.9    53.97    60.2
   Azimuth:315   Height:102 Vert     Margin [dB]         -6.07    -12.3
8 4179.59       76.48 pk     -52.91    34.41     57.98   53.97    60.2
   Azimuth:44    Height:102 Vert     Margin [dB]         4.01     -2.23
9 4597.799      70.12 pk     -52.42    34.13     51.83   53.97    60.2
   Azimuth:58    Height:102 Vert     Margin [dB]         -2.14    -8.37

LIMIT 1: CFR 47 Part 15       Class B 3m
LIMIT 2: SPURIOUS LIMIT

pk - Peak detector




File MC3486   Project 02NK45212            /                Page B11 of B13

UL International EMC Services          www.ul.com/emc     (800) USE UL EMC


                                                                  FCC ID: JM7-IGWT-662002


Accutech
 TAG (Vertical Orientation)
 TX Mode
 Internal Battery
 Red:Horizontal Green:Vertical

  Test     Meter     Gain/Loss Transducer Level Limit:1         2
Frequency Reading     Factor     Factor dB[uVolts/meter]
 [MHz]     [dB(uV)]     [dB]      [dB]
======================================================================
Range: 3 1000 - 5000MHz
4597.37    57.19 av      -52.4     34.1      38.89   54       60.2
Azimuth: 338 Height:122 Horz          Margin [dB]:   -15.11   -21.31

4597.37    68.85 av      -52.4         34.1      50.55   54        60.2
Azimuth: 27   Height:110 Vert             Margin [dB]:   -3.45     -9.65

4179.43    72.8 av       -52.9         34.4      54.3    54        60.2
Azimuth: 0    Height:142 Vert             Margin [dB]:   .3        -5.9

4179.4278 63.45 av      -52.9          34.4      44.95   54        60.2
Azimuth: 253 Height:140 Horz              Margin [dB]:   -9.05     -15.25

2925.5972 57.2 av       -51.6          31.4      37      54        60.2
Azimuth: 350 Height:122 Horz              Margin [dB]:   -17       -23.2

2925.5983 65.55 av      -51.6          31.4      45.35   54        60.2
Azimuth: 132 Height:122 Vert              Margin [dB]:   -8.65     -14.85


LIMIT 1: CFR 47 Part 15       Class B 3m
LIMIT 2: SPURIOUS LIMIT

av - Average detector




File MC3486   Project 02NK45212            /                      Page B12 of B13

UL International EMC Services          www.ul.com/emc            (800) USE UL EMC


                                                                          FCC ID: JM7-IGWT-662002


                         UNDERWRITERS LABORATORIES INC.
                              Band Edge Measurement

                                                                     Date Tested: 31 October 2002

Manufacturer                 :    Accutec
Equipment Under Test         :    TAG (TX Mode)
Requirement                  :    CFR 47, Part 15, Class B
Detection Mode               :    Quasi-peak (qp) and Average (Av)
Bandwidth                    :    120 kHz
Measurement Distance         :    3 meter
Antenna Type                 :    300 - 1000 MHz Log-Periodic




File MC3486   Project 02NK45212                 /                         Page B13 of B13

UL International EMC Services               www.ul.com/emc             (800) USE UL EMC


                                                                                FCC ID: JM7-IGWT-662002




                                                 APPENDIX C


                                Sample Calculations of Field Strengths


Basic Equation:

The field strength is calculated by adding the Meter Reading, Cable Set Gain/Loss and Transducer
(Antenna or LISN) Factor. The basic equation is as follows:

         FS = MR + GL + TF

Where:
         FS = Calculated Field Strength in dB(uV)/meter

         MR = Meter Reading of receiver amplitude in dB(uV)

         GL = Gain/Loss factor of cable set in dB
               A negative Gain/Loss indicates signal amplification (gain)
               A positive Gain/Loss indicates signal attenuation (loss)

         TF = Transducer Factor of antenna or LISN in dB


Sample Calculation:

         The measured receiver amplitude is 52.7 dB(uV).

         The gain/loss factor is –30.2 dB (indicating a preamplifier is included in the cable set).

         The transducer factor (antenna factor) is 6.6 dB.

         These factors are added (52.7 + (-30.2) + 6.6) resulting in a calculated field strength of 29.1
         dB(uV)/meter.




 File MC3486    Project 02NK                                                      Page C1 of C2
UL International EMC Services                 www.ul.com/emc                 (800) USE UL EMC


                                                                            FCC ID: JM7-IGWT-662002


                                    Sample Calculations of Limit


Basic Equation:

The limit is calculated by using the information in table 15.209 for frequency (MHz), field strength
(uV/m) and measurement distance (meters).

The basic equation for converting uV/m to dBuV/m is as follows:

         20 Log (uV/m) = dBuV/m

Where:
         uV/m = micro volts per meter

         dBuV/m = decibel micro volts per meter


Sample Calculation:

         The field strength per section 15.209 at 30 MHz (3 m measurement distance) is 100 uV/m.

         20 Log (100 uV/m) = 40 dBuV/m




 File MC3486    Project 02NK                                                  Page C2 of C2
UL International EMC Services              www.ul.com/emc                 (800) USE UL EMC



Document Created: 2003-06-03 14:03:18
Document Modified: 2003-06-03 14:03:18

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC