TEST REPORT

FCC ID: JLFTRX

Test Report

Download: PDF
FCCID_469398

                                                                                   FCCID: JLFTRX




Date:                        August 31, 2004

Federal Communications Commission
Via: Electronic Filing

Attention:                   Authorization & Evaluation Division


Applicant:                   International Electronics Inc
Equipment:                   The Reporter Voice
FCC ID:                      JLFTRX
FCC Rules:                   2, 15.249



Gentlemen:


On behalf of the Applicant, enclosed please find Application Form 731, Engineering Test Report
and all pertinent documentation, the whole for approval of the referenced equipment as shown.


Filing fees are attached.


We trust the same is in order. Should you need any further information, kindly contact the writer
who is authorized to act as agent.




                                                         Sincerely yours,




                                                         Michael Schafer,
                                                         Business Director

enclosure(s)
cc: Applicant
MS/del




MFA p0480015, d0480104


                                                                             FCCID: JLFTRX

                                        List Of Exhibits
                      (FCC Certification (Transmitters) - Revised 9/28/98)


Applicant:                     International Electronics Inc


FCC ID:                        JLFTRX




By Applicant:


              1. Letter Of Authorization

              2. Identification Drawings
                     Label
                     Location of Label
                     Compliance Statement
                     Location of Compliance Statement

              3. Documentation: 2.1033(B)
                     (3)   User Manual
                     (4)   Operational Description
                     (5)   Block Diagram
                     (5)   Schematic Diagram
                     (7)   Photographs
                           Block Diagram
                           Parts List
                           Active Devices

              4. Draft Specification Information




By M.F.A. Inc.


                 A.    Testimonial & Statement of Certification




MFA p0480015, d0480104


                                                                                  FCCID: JLFTRX




                          Transmitter Certification
                                              of


                                  Model: The Reporter Voice
                                       FCCID: JLFTRX

                                              to


                         Federal Communications Commission


                                     Rule Parts 2, 15.249


                           Date Of Report: August 31, 2004


On the Behalf of the Applicant:

                          International Electronics, Inc.

At the Request of:                                                                  P.O.12422

                          International Electronics, Inc.
                          5913-C NE 127th Avenue, Suite#800
                          Vancouver, WA 98682, USA

Attention of:             Shary Nissimi




Supervised By:                                          David E. Lee,
                                                        Compliance Test Manager




MFA p0480015, d0480104


                                                                                      FCCID: JLFTRX




             The Applicant has been cautioned as to the following:




15.21         Information to User.


       The users manual or instruction manual for an intentional radiator shall caution the user
that changes or modifications not expressly approved by the party responsible for compliance
could void the user's authority to operate the equipment.



15.27(a)      Special Accessories.


        Equipment marketed to a consumer must be capable of complying with the necessary
regulations in the configuration in which the equipment is marketed. Where special accessories,
such as shielded cables and/or special connectors are required to enable an unintentional or
intentional radiator to comply with the emission limits in this part, the equipment must be
marketed with, i.e. shipped and sold with, those special accessories. However, in lieu of shipping
or packaging the special accessories with the unintentional or intentional radiator, the responsible
party may employ other methods of ensuring that the special accessories are provided to the
consumer, without additional charge.


        Information detailing any alternative method used to supply the special accessories for a
grant of equipment authorization or retained in the verification records, as appropriate. The party
responsible for the equipment, as detailed in § 2.909 of this chapter, shall ensure that these
special accessories are provided with the equipment. The instruction manual for such devices shall
include appropriate instructions on the first page of text concerned with the installation of the
device that these special accessories must be used with the device. It is the responsibility of the
user to use the needed special accessories supplied with the equipment.




MFA p0480015, d0480104


                                                                          FCCID: JLFTRX


                                    Table Of Contents


Rule                 Description                                                 Page


.                    Test Report                                                     1

2.1033(c)            General Information Required                                    2

.                    Standard Test Conditions and Engineering Practices              6

2.1053(a)            Field Strength of Spurious Radiation                            7

15.249(a).           Maximum Radiated Field Strength                                12

15.249(c).           Radiated Spurious Emissions (Non-Harmonic)                     14

2.1049(c)(1)         Emission Masks (Occupied Bandwidth)                            15

15.207               A/C Powerline Conducted Emissions                              19




MFA p0480015, d0480104


                                                                                    FCCID: JLFTRX


Page Number                1 of 22.

Required information per ISO/IEC Guide 25-1990, paragraph 13.2:

a)                                      Test Report

b) Laboratory:             M. Flom Associates, Inc.
 (FCC: 31040/SIT)          3356 N. San Marcos Place, Suite 107
 (Canada: IC 2044)         Chandler, AZ 85225

c) Report Number:          d0480086

d) Client:                 International Electronics Inc

e) Identification:         The Reporter Voice System
  Description:             Base Unit

f) EUT Condition:          Not required unless specified in individual tests.

g) Report Date:            August 27, 2004
  EUT Received:            July 30, 2004

h, j, k):                  As indicated in individual tests.

i) Sampling method:        No sampling procedure used.

l) Uncertainty:            In accordance with MFA internal quality manual.

m) Supervised by:


                                                         David E. Lee,
                                                         Compliance Test Manager

n) Results:                The results presented in this report relate only to the item tested.

o) Reproduction:           This report must not be reproduced, except in full, without written
                           permission from this laboratory.




MFA p0480015, d0480104


                                                                                  FCCID: JLFTRX




Page Number                  2 of 22.

                  List Of General Information Required For Certification

                          In Accordance with FCC Rules and Regulations,
                                 Volume II, Part 2 and to 15.249


Sub-Part 2.1033
(c)(1): Name and Address of Applicant:

                              International Electronics, Inc.
                              5913-C NE 127th Avenue, Suite#800
                              Vancouver, WA 98682, USA

              Manufacturer:
                           Applicant

(c)(2): FCC ID:                                           JLFTRX

              Model Number:                               The Reporter Voice Base Unit

(c)(3): Instruction Manual(s):

                     Please See Attached Exhibits


(c)(4): Type of Emission:                                 ASK


(c)(5): FREQUENCY RANGE, MHz:                             916.500


(c)(6): Power Rating,:                                    31.915 mV/m @3m
                   Switchable                  Variable           X N/A


(c)(7): Maximum Power Rating,:                            50 mV/m @ 3m

15.203:       Antenna    Requirement:
                  The    antenna is permanently attached to the EUT
               X The     antenna uses a unique coupling
                  The    EUT must be professionally installed
                  The    antenna requirement does not apply




MFA p0480015, d0480104


                                                                                      FCCID: JLFTRX


Page Number                    3 of 22.

Subpart 2.1033 (continued)
(c)(8): Voltages & Currents in All Elements in Final RF Stage, Including Final Transistor or Solid
               State Device:

                     Collector Current, A              = 0.012
                     Collector Voltage, Vdc            = 3.7
                     Supply Voltage, Vdc               = 6


(c)(9):       Tune-Up Procedure:

                     Please See Attached Exhibits


(c)(10):      Circuit Diagram/Circuit Description:
              Including description of circuitry & devices provided for determining and stabilizing
              frequency, for suppression of spurious radiation, for limiting modulation and limiting
              power.

                     Please See Attached Exhibits


(c)(11):      Label Information:

                     Please See Attached Exhibits


(c)(12):      Photographs:

                     Please See Attached Exhibits


(c)(13):      Digital Modulation Description:

                     ___ Attached Exhibits
                     _x_ N/A


(c)(14):      Test and Measurement Data:

                     Follows




MFA p0480015, d0480104


                                                                       FCCID: JLFTRX


Page Number              4 of 22.


                                    A2LA
                                    “A2LA has accredited M. Flom Associates, Inc.
                                    Chandler, AZ for technical competence in the
                                    field of Electrical Testing. The accreditation
                                    covers the specific tests and types of tests
                                    listed on the agreed scope of accreditation.
                                    This laboratory meets the requirements of
                                    ISO/IEC 17025 – 1999 ‘General Requirements
                                    for the Competence of Testing and Calibration
                                    Laboratories’ and any additional program
                                    requirements in the identified field of testing.”




                                    Certificate Number: 2152-01




                                    NIST
                                    I am pleased to inform you that your
                                    laboratory has been validated by the Chinese
                                    Taipei Bureau of Standards, Metrology and
                                    Inspection (BSMI) under the Asia Pacific
                                    Economic Cooperation Mutual Recognition
                                    Agreement (APEC MRA). Your laboratory is
                                    now formally designated to act as a
                                    Conformity Assessment Body (CAB) under
                                    Appendix B, Phase I Procedures, of the APEC
                                    MRA between the American Institute in Taiwan
                                    (AIT) and the Taipei Economic and Cultural
                                    Representative Office (TECRO) in the United
                                    States, covering equipment subject to Electro-
                                    Magnetic Compatibility (EMC) requirements.
                                    The names of all validated and nominated
                                    laboratories will be posted on the NIST
                                    website at http://ts.nist.gov/mra under the
                                    ‘Asia’ category.”




MFA p0480015, d0480104


                                                                                FCCID: JLFTRX


Page Number                 5 of 22.

Sub-part
2.1033(b):                       Test and Measurement Data

       All tests and measurement data shown were performed in accordance with FCC Rules and
Regulations, Volume II; Part 2, Sub-part J, Sections 2.1031, 2.1033, 2.1035, 2.1041, 2.1043,
2.1045, and the following individual Parts:

       15.209    Radiated emission limits; general requirements
      15.211     Tunnel radio systems
      15.213     Cable locating equipment
      15.214     Cordless telephones
      15.217     Operation in the band 160-190 kHz
      15.219     Operation in the band 510-1705 kHz
      15.221     Operation in the band 525-1705 kHz (leaky coax)
      15.223     Operation in the band 1.705-10 MHz
      15.225     Operation in the band 13.553-13.567 MHz
      15.227     Operation in the band 26-27.28 MHz (remote control)
      15.229     Operation in the band 40.66-40.70 MHz
      15.231     Periodic operation in the band 40.66-40.70 MHz and above 70 MHz
      15.233     Operation within the bands 43.71-44.49, 46.60-46.98 MHz
                 48.75-49.51 MHz and 49.66-50.0 MHz
      15.235     Operation within the band 49.82-49.90 MHz
      15.237     Operation within the bands 72.0-73.0 MHz, 74.6-74.8 MHz
                 and 75.2-76.0 MHz (auditory assistance)
      15.239     Operation in band 88-108 MHz
      15.241     Operation in the band 174-216 MHz (biomedical)
      15.243     Operation in the band 890-940 MHz (materials)
      15.245     Operation within the bands 902-928 MHz, 2435-2465 MHz, 5785-5815 MHz,
                 10500-10550 MHz, and 24075-24175 MHz (filed disturbance sensors)
      15.247     Operation within bands 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz
                 (spread spectrum)
 X    15.249     Operation within the bands 902-928 MHz, 2400-2483.5 MHz, 5725-5875 MHz,
                 and 24.0-24.25 GHz
      15.251     Operation within the bands 2.9-3.26 GHz, 3.267-3.332 GHz, 3.339-3.3458 GHz,
                 and 3.358-3.6 GHz (vehicle identification systems)
      15.321     Specific requirements for asynchronous devices operating in the 1910-1920
                 MHz and 2390-2400 MHz bands (Unlicensed PCS)
      15.323     Specific requirements for isochronous devices operating in the 1920-1930 MHz
                 sub-band (Unlicensed PCS)




MFA p0480015, d0480104


                                                                                    FCCID: JLFTRX


Page Number                  6 of 22.

                                  Standard Test Conditions
                                            And
                                    Engineering Practices



        Except as noted herein, the following conditions and procedures were observed during the
testing:


        In accordance with ANSIC63.4-1992/2001, section 6.1.9, and unless otherwise indicated in
the specific measurement results, the ambient temperature of the actual EUT was maintained
within the range of 10° to 40°C (50° to 104 °F) unless the particular equipment requirements
specify testing over a different temperature range. Also, unless otherwise indicated, the humidity
levels were in the range of 10% to 90% relative humidity.


       Prior to testing, the EUT was tuned up in accordance with the manufacturer's alignment
procedures. All external gain controls were maintained at the position of maximum and/or
optimum gain throughout the testing.


       Measurement results, unless otherwise noted, are worst-case measurements.




MFA p0480015, d0480104


                                                                                    FCCID: JLFTRX


Page Number                   7 of 22.

Name of Test:                 Field Strength of Spurious Radiation

Specification:                47 CFR 2.1053(a)

Guide:                        ANSI/TIA/EIA-603-1992/2001, Paragraph 1.2.12 and Table 16, 47
                              CFR 22.917

                                  Measurement Procedure

1.2.12.1       Definition: Radiated spurious emissions are emissions
               from the equipment when transmitting into a non-radiating load on a frequency
               or frequencies which are outside an occupied band sufficient to ensure
               transmission of information of required quality for the class of communications
               desired.

1.2.12.2 Method of Measurement

A)       Connect the equipment as illustrated

B)       Adjust the spectrum analyzer for the following settings:
         1) Resolution Bandwidth 100 kHz (<1 GHZ), 1 MHZ (> 1GHz).
         2) Video Bandwidth ≥ 3 times Resolution Bandwidth, or 30 kHz
           (22.917)
         3) Sweep Speed ≤2000 Hz/second
         4) Detector Mode = Mean or Average Power

C)     Place the transmitter to be tested on the turntable in the standard test site. The
       transmitter is transmitting into a non-radiating load which is placed on the turntable.
       The RF cable to this load should be of minimum length.




MFA p0480015, d0480104


                                                                                   FCCID: JLFTRX


Page Number                 8 of 22.

Name of Test:               Field Strength of Spurious Radiation (Cont.)

D)     For each spurious measurement the test antenna should be adjusted to the correct
       length for the frequency involved. This length may be determined from a calibration
       ruler supplied with the equipment. Measurements shall be made from the lowest radio
       frequency generated in the equipment to the tenth harmonic of the carrier, except for
       the region close to the carrier equal to ± the test bandwidth (see section 1.3.4.4).

E)     For each spurious frequency, raise and lower the test antenna from 1 m to 4 m to obtain
       a maximum reading on the spectrum analyzer with the test antenna at horizontal
       polarity. Repeat this procedure to obtain the highest possible reading. Record this
       maximum reading.

F)     Repeat step E) for each spurious frequency with the test antenna polarized vertically.




G)     Reconnect the equipment as illustrated.

H)     Keep the spectrum analyzer adjusted as in step B).

I)     Remove the transmitter and replace it with a substitution antenna (the antenna should
       be half-wavelength for each frequency involved). The center of the substitution antenna
       should be approximately at the same location as the center of the transmitter. At lower
       frequencies, where the substitution antenna is very long, this will be impossible to
       achieve when the antenna is polarized vertically. In such case the lower end of the
       antenna should be 0.3 m above the ground.




MFA p0480015, d0480104


                                                                                               FCCID: JLFTRX


Page Number                 9 of 22.

Name of Test:               Field Strength of Spurious Radiation (Cont.)

J)     Feed the substitution antenna at the transmitter end with a signal generator connected
       to the antenna by means of a non-radiating cable. With the antennas at both ends
       horizontally polarized and with the signal generator tuned to a particular spurious
       frequency, raise and lower the test antenna to obtain a maximum reading at the
       spectrum analyzer. Adjust the level of the signal generator output until the previously
       recorded maximum reading for this set of conditions is obtained. This should be done
       carefully repeating the adjustment of the test antenna and generator output.

K)     Repeat step J) with both antennas vertically polarized for each spurious frequency.

L)     Calculate power in dBm into a reference ideal half-wave dipole antenna by reducing the
       readings obtained in steps J) and K) by the power loss in the cable between the
       generator and the antenna and further corrected for the gain of the substitution antenna
       used relative to an ideal half-wave dipole antenna.

M)     The levels recorded in step L) are absolute levels of radiated
       spurious emissions in dBm. The radiated spurious emissions in dB can be calculated by
       the following:

Radiated spurious emissions dB =
       10log10(TX power in watts/0.001) – the levels in step l)

NOTE: It is permissible that other antennas provided can be referenced to a dipole.

Test Equipment:
     Asset      Description                            s/n                 Cycle                          Last Cal
                                                                                Per ANSI C63.4-1992/2000 Draft, 10.1.4

     (as applicable)
Transducer
     i00088     EMCO 3109-B 25MHz-300MHz               2336                24   mo.                        Sep-03
     i00065     EMCO 3301-B Active Monopole            2635                24   mo.                        Sep-03
X i00089        Aprel 2001 200MHz-1GHz                 001500              24   mo.                        Sep-03
X i00103        EMCO 3115 1GHz-18GHz                   9208-3925           24   mo.                        Sep-03

Amplifier
X i00028        HP 8449A                               2749A00121          12 mo.                          Mar-04


Spectrum Analyzer
    i00029  HP 8563E                                   3213A00104          12 mo.                          Mar-04

X    i00033     HP 85462A                              3625A00357          12 mo.                          Sep-03




MFA p0480015, d0480104


                                              FCCID: JLFTRX




Page Number              10 of 22.

Test Setup:              Radiated Emissions

State:




State:




MFA p0480015, d0480104


                                                                               FCCID: JLFTRX


Page Number                 11 of 22.

Name of Test:             Field Strength of Spurious Radiation
g0480108: 2004-Aug-20 Fri 14:33:00
State: 2:High Power

 Frequency Tuned, MHz     Frequency Emission, MHz     Meter, dBuV     CF, dB    uV/m @ 3m
    916.500000               1833.196000              12.34         41.05        329.93
    916.500000               2749.780000              12.23         37.18        261.98
    916.500000               3666.400000              31.33         12.70        159.04
    916.500000               4583.000000              28.83         15.17        158.49
    916.500000               5499.600000              27.17         15.26        132.28
    916.500000               6416.200000              30.50         16.55        225.16
    916.500000               7332.800000              31.50         17.87        294.10
    916.500000               8249.400000              28.50         20.65        286.75
    916.500000               9166.000000              30.00         18.59        268.84




MFA p0480015, d0480104


                                                                                          FCCID: JLFTRX


Page Number                  12 of 22.

Name of Test:                Maximum Radiated Field Strength

Specification:               47 CFR 15.249(a)

Spec. Limit:                 50 mV/m @ 3m

                                     Radiated Test Setup




NOTES:
(a) Search Antenna - Rotatable on boom          (j) Cables routed through hollow turntable
(b) Non-metallic boom                               center
(c) Non-metallic mast                           (k) 30 cm or less
(d) Adjustable horizontally                     (l) External power source
(e) Equipment Under Test                        (m) 10 cm diameter coil of excess cable
(f) Turntable                                   (n) 25 cm (V), 1 m-7 m (V, H)
(g) Boom adjustable in height.                  (o)    25 cm from bottom end of 'V', 1m
(h)    External control cables routed           normally
horizontally at least one wavelength.           (p) Calibrated Cable at least 10m in length
(i) Rotatable                                   (q) Amplifier (optional)
                                                (r) Spectrum Analyzer

    Asset      Description                           s/n              Cycle                    Last Cal
    (as applicable)                                                            Per ANSI C63.4-1992, 10.1.4




Transducer
X i00088         EMCO 3109-B 25MHz-300MHz            2336             24 mo.                   Sep-03
X i00089         Aprel 2001 200MHz-1GHz              001500           24 mo.                   Sep-03
X i00103         EMCO 3115 1GHz-18GHz                9208-3925        24 mo.                   Sep-03

Amplifier
X i00028         HP 8449A                            2749A00121       12 mo.                   Mar-04

Spectrum Analyzer
X i00029    HP 8563E                                 3213A00104       12 mo.                   Jan-04
X i00033    HP 85462A                                3625A00357       12 mo.                   Sep-03




MFA p0480015, d0480104


                                                                               FCCID: JLFTRX

Page Number               13 of 22.

                                      Measurement Data


g0480109:2004-Aug-20 Fri 14:59:00
  Frequency Tuned, MHz   Frequency Emission, MHz   Meter, dBuV      CF, dB     uV/m @ 3m
    916.500000               916.495000             55.41        34.67         31915.38




Supervised By:                                      David E. Lee,
                                                    Compliance Test Engineer




MFA p0480015, d0480104


                                                                                   FCCID: JLFTRX


Page Number                 14 of 22.

Name of Test:               Radiated Spurious Emissions (Non-Harmonic)

Specification:              47 CFR 15.249(c)

Guide:                      ANSI/TIA/EIA-603-1992/2001, Paragraph 2.2.1

Test Equipment:             As per previous page

15.249(c):
         Emissions radiated outside of the specified frequency bands, except for harmonics,
         shall be attenuated by at least 50 dB below the level of the fundamental or to the
         general radiated emissions limits in § 15.209, whichever is the lesser attenuation.

General Radiated Emission Limits Per 15.209:


                 Frequency, MHz                           Field Strength, µV/m @ 3m

                    30 – 88                                          100
                    88 – 216                                         150
                   216 – 960                                         200
                   Above 960                                         300

Measurement Results:

              Frequency of Carrier, MHz              =   916.500000
              Spectrum Searched                      =   0 to 10 x FC
              All Other Emissions                    =   ≥ 20 dB Below Limit
              Limit, µV /m @ 3m                      =   50 dBc or § 15.209

                     All Spurious Emissions were 20 Db or more below limit

                                  System sensitivity –130 dBm




Supervised By:                                           David E. Lee,
                                                         Compliance Test Manager




MFA p0480015, d0480104


                                                                                 FCCID: JLFTRX


Page Number                  15 of 22.

Name of Test:                Emission Masks (Occupied Bandwidth)

Specification:               47 CFR 2.1049(c)(1)

Guide:                       ANSI/TIA/EIA-603-1992, Paragraph 2.2.11

Test Equipment:              As per previous page


                                 Measurement Procedure


1.       The EUT and test equipment were set up as shown on the following page, with the
         Spectrum Analyzer connected.


2.     For EUTs supporting audio modulation, the audio signal generator was adjusted to the
       frequency of maximum response and with output level set for ±2.5 kHz deviation (or 50%
       modulation). With level constant, the signal level was increased 16 dB.


3.     For EUTs supporting digital modulation, the digital modulation mode was operated to its
       maximum extent.


4.       The Occupied Bandwidth was measured with the Spectrum Analyzer controls set as shown
         on the test results.


5.       Measurement Results:       Attached




MFA p0480015, d0480104


                                                                         FCCID: JLFTRX


Page Number


                                Transmitter Spurious Emission

        Test A. Occupied Bandwidth (In-Band Spurious)
        Test B. Out-of-Band Spurious




                         Test
                                                                (1)
                     Sample




                                                                (2)




      Asset    Description                         s/n

(1)     Antenna – Loose Coupled

(2)   Spectrum Analyzer
 X i00029    HP 8563E                              3213A00104   12 mo.    Jan-04
 X i00033    HP 85462A                             3625A00357   12 mo.    Sep-03




MFA p0480015, d0480104


                                                                                         FCCID: JLFTRX


Page Number                    17 of 22.

Name of Test:             Emission Masks (Occupied Bandwidth)
g0480116: 2004-Aug-27 Fri 07:59:00
State: 2:High Power



                     ATTEN     10dB                      MKR    -7.3dBm
                     RL   -7.3dBm          10dB/         916.500MHz




                 D



                 R




                   START    901.00MHz                   STOP     929.00MHz
                 *RBW    100kHz       *VBW     300kHz              SWP   50.0ms




                       Power:                                  HIGH (LOOSE COUPLED)
                       Modulation:                             ASK
                                                               BAND EDGES




Supervised By:                                                 David E. Lee,
                                                               Compliance Test Manager




MFA p0480015, d0480104


                                                                                                FCCID: JLFTRX


Page Number                       18 of 22.

Name of Test:             Emission Masks (Occupied Bandwidth)
                          Indicating 20 dB Bandwidth
g0480118: 2004-Aug-27 Fri 08:13:00
State: 2:High Power


                       ATTEN     10dB                       MKR    -5.10dBm
                       RL   -5.1dBm           10dB/         916.500MHz
                 3dB


                 20dB




                    START    915.500MHz                    STOP   917.500MHz
                  *RBW    100kHz       *VBW       300kHz            SWP   50.0ms




                         Power:                                       HIGH (LOOSE COUPLED)
                         Modulation:                                  ASK
                                                                      SIGNAL BAND WIDTH
                                                                      250kHz @ 20dB




Supervised By:                                                        David E. Lee,
                                                                      Compliance Test Manager




MFA p0480015, d0480104


                                                                                       FCCID: JLFTRX


Page Number                    19 of 22.

Name of Test:                  A/C Powerline Conducted Emissions

Specification:                 FCC:   47 CFR 15.27

Guide:                         IEEE Standard 213

Test Conditions:               S. T. & H.

Test Equipment:                As per attached page

                                      Measurement Procedure

1.       A test sample was connected to the Public Utility lines through a LISN (50 µH).

2.     A reference level of 250 µV was set on the Spectrum Analyzer. The spectrum was searched
       over the range of 450 kHz to 30 MHz.

3.       All other emissions were 20 dB or more below limit.

4.        X   The test sample used a charger.
              The test sample does not use a charger.

5.       Measurement Results: Attached.




MFA p0480015, d0480104


                                                                                                     FCCID: JLFTRX


Page Number                   20 of 22.


                           AC Powerline Conducted Measurements




                 Public                            (2)     Test
                 Utility                   (1)




                                                                           A/C Powerline Conducted
                                                          Sample
                  Line




                                           (3)




    Asset      Description                         s/n             Cycle                              Last Cal
                                                                           Per ANSI C63.4-1992/2000 Draft, 10.1.4




(1) Line Impedance Stabilization Network
     i00244   Fischer 50-20-2-01                   2047            NCR
(2) Screen Room
 X i00170     Lindgren LG170                       4999            NCR
(3) Spectrum Analyzer
 X i00033     HP 85462A                            3625A00357      12 mo.                             Sep-03




MFA p0480015, d0480104


                                                             FCCID: JLFTRX


Page Number              21 of 22.
                             Photograph(s) of Test Setup

Test Setup:              A/C Powerline Conducted Emissions




MFA p0480015, d0480104


                                                                                  FCCID: JLFTRX


Page Number                22 of 22.

Name of Test:              A/C Powerline Conducted Emissions
47 CFR 15.107(a):

A/C Powerline Conducted Emission Limits

                            15.107(a) Class B Conducted Limits
            Frequency of Emission,                     µV                     dBuV
                    MHz
                 0.150 - 30                           250                         48

g0480111: 2004-Aug-20 Fri 15:51:00
State: 0:General
Frequency Tuned,    Frequency             Level, dBuV       C.F., dB          µV
       MHz        Emission, MHz
     916.500000        0.160000            39.96               1.24          114.82
     916.500000        0.230000            42.03               0.83          139.00
     916.500000        0.300000            39.85               0.62          105.56
     916.500000        0.460000            34.24               0.61           55.27
     916.500000        0.620000            32.24               0.60           43.85
     916.500000        0.700000            25.46               0.60           20.09


g0480112: 2004-Aug-20 Fri 16:03:00
State: 0:General
Frequency Tuned,    Frequency             Level, dBuV       C.F., dB          µV
       MHz        Emission, MHz
     916.500000        0.150000            41.85               1.39          145.21
     916.500000        0.240000            43.6                0.82          167.49
     916.500000        0.310000            41.46               0.63          127.00
     916.500000        0.480000            36.26               0.60           69.66
     916.500000        0.600000            35.06               0.57           60.46
     916.500000        0.900000            27.32               0.53           24.69




Supervised By:                                          David E. Lee,
                                                        Compliance Test Manager




MFA p0480015, d0480104


                                                                           FCCID: JLFTRX

NOTICE:

§ 15.205 Restricted Bands of Operation


       (a) Except as shown in paragraph (b) of this section, only spurious emissions are
permitted in any of the frequency bands listed below:


          MHz                            MHz                MHz               GHz

  0.090-0.110                16.42-16.423             399.9-410           4.5-5.25

  0.495-0.505              16.69475-16.69625           608-614            5.35-5.46
 2.1735-2.1905             16.80425-16.80475           960-1240           7.25-7.75
  4.125-4.128                 25.5-25.67               1300-1427         8.025-8.5
4.17725-4.17775               37.5-38.25               1435-1626.5        9.0-9.2
4.20725-4.20775                73-74.6               1645.5-1646.5        9.3-9.5
  6.215-6.218                 74.8-75.2                1660-1710          10.6-12.7
6.26775-6.26825               108-121.94             1718.8-1722.2       13.25-13.4
6.31175-6.31225               123-138                  2200-2300         14.47-14.5
  8.291-8.294                149.9-150.05              2310-2390         15.35-16.2
  8.362-8.366             156.52475-156.52525        2483.5-2500          17.7-21.4
8.37625-8.38675              156.7-156.9               2655-2900         22.01-23.12
8.41425-8.41475            162.0125-167.17             3260-3267          23.6-24.0
  12.29-12.293              167.72-173.2               3332-3339          31.2-31.8
12.51975-12.52025             240-285                3345.8-3358         36.43-36.5
12.57675-12.57725             322-339.4                3600-4400
  13.36-13.41




MFA p0480015, d0480104


                                                                                    FCCID: JLFTRX



                                     Testimonial
                                         and
                               Statement of Certification




This is to certify that:




       1.     That the application was prepared either by, or under the direct supervision of, the
              undersigned.

       2.     That the technical data supplied with the application was taken under my direction
              and supervision.

       3.     That the data was obtained on representative units, randomly selected.

       4.     That, to the best of my knowledge and belief, the facts set forth in the application
              and accompanying technical data are true and correct.




Certifying Engineer:                                     David E. Lee,
                                                         Compliance Test Manager




MFA p0480015, d0480104



Document Created: 2004-09-09 14:22:36
Document Modified: 2004-09-09 14:22:36

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC