Test Report

FCC ID: JLFPTE1

Test Report

Download: PDF
FCCID_872078

Date:                              August 22, 2007


Federal Communications Commission
Via: Electronic Filing


Attention:                         Authorization & Evaluation Division

Applicant:                         International Electronics Inc.
Equipment:                         Push to Exit
FCC ID:                            JLFPTE1
FCC Rules:                         15.249



Gentlemen:


On behalf of the Applicant, enclosed please find Application Form 731, Engineering Test Report and all pertinent
documentation, the whole for approval of the referenced equipment as shown.


We trust the same is in order. Should you need any further information, kindly contact the writer who is authorized
to act as agent.


                                                                    Sincerely yours,




                                                                    Hoosamuddin S. Bandukwala, Lab Director
enclosure(s)
cc: Applicant
HSB/mdw




Flom Test Labs
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                                                    List Of Exhibits
                            (FCC Certification (Transmitters) - Revised 9/28/98)


Applicant:                         International Electronics Inc.

FCC ID:                            JLFPTE1


By Applicant:


                 1. Letter Of Authorization

                 2. Identification Drawings
                              Id Label
                              Location Info
                              Attestation Statement(s)
                              Location of Compliance Statement

                 3. Documentation: 2.1033(B)
                        (3)     User Manual(s)
                        (4)     Operational Description
                        (5)     Block Diagram
                        (5)     Schematic Diagram
                        (7)     External Photographs
                                Internal Photographs
                                Parts List
                                Active Devices




By F.T.L. Inc.


                 A.      Testimonial & Statement of Certification

                 B.      Statement of Qualifications




Flom Test Labs
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                       p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                                     Transmitter Certification
                                                     of

                                             FCC ID: JLFPTE1
                                             Model: Push to Exit

                                                     to

                                   Federal Communications Commission

                                             Rule Part(s) 15.249

                                      Date Of Report: August 22, 2007
                                  Date of Revised Report: November 15, 2007




On the Behalf of the Applicant:      International Electronics Inc.
                                     5913-C NE 127th Ave, Suite 800
                                     Vancouver, WA 98682


Attention of:                        Shary Nassimi, President
                                     (360) 241-9090
                                     email: iei@nwlink.com




Supervised By:                                                     Hoosamuddin S. Bandukwala, Lab Director



Flom Test Labs
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                            p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                            The applicant has been cautioned as to the following:

15.21            Information to User.

        The users manual or instruction manual for an intentional radiator shall caution the user that changes or
modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.

15.27(a)         Special Accessories.

          Equipment marketed to a consumer must be capable of complying with the necessary regulations in the
configuration in which the equipment is marketed. Where special accessories, such as shielded cables and/or
special connectors are required to enable an unintentional or intentional radiator to comply with the emission
limits in this part, the equipment must be marketed with, i.e. shipped and sold with, those special accessories.
However, in lieu of shipping or packaging the special accessories with the unintentional or intentional radiator, the
responsible party may employ other methods of ensuring that the special accessories are provided to the
consumer, without additional charge.

        Information detailing any alternative method used to supply the special accessories for a grant of
equipment authorization or retained in the verification records, as appropriate. The party responsible for the
equipment, as detailed in § 2.909 of this chapter, shall ensure that these special accessories are provided with
the equipment. The instruction manual for such devices shall include appropriate instructions on the first page of
text concerned with the installation of the device that these special accessories must be used with the device. It is
the responsibility of the user to use the needed special accessories supplied with the equipment.




Flom Test Labs
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                  p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                             Testimonial And Statement Of Certification


This is to certify that:


        1.       That the application was prepared either by, or under the direct supervision of, the undersigned.

        2.       That the technical data supplied with the application was taken under my direction and
                 supervision.

        3.       That the data was obtained on representative units, randomly selected.

        4.       That, to the best of my knowledge and belief, the facts set forth in the application and
                 accompanying technical data are true and correct.




Certifying Engineer:                                                Hoosamuddin S. Bandukwala, Lab Director




Flom Test Labs
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                                                p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                                           Table Of Contents


Rule                  Description                                                       Page



                      Test Report                                                           1

2.1033(c)             General Information Required                                          2

.                     Standard Test Conditions and Engineering Practices                    4

                      Test Results Summary                                                  5

15.249.               Field Strength of Fundamental                                         6

15.249(d)             Field Strength of Harmonics                                           6

15.249(c),            Radiated Spurious Emissions                                           8

.                     Test Equipment Utilized                                              11




Flom Test Labs
3356 N. San Marcos Place, Suite 107
Chandler, Arizona 85225-7176                                               p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


Required information per ISO 17025-2005, paragraph 5.10:
a)                                            Test Report

b) Laboratory:                 Flom Test Lab, Inc.
 (FCC: 31040/SIT)              3356 N. San Marcos Place, Suite 107
 (Canada: IC 2044)             Chandler, AZ 85225

c) Report Number:              d0780025

d) Client:                     International Electronics Inc.

e) Identification:             Push to Exit

  Description:                 Transmitter

f) EUT Condition:              Not required unless specified in individual tests.

g) Report Date:                August 22, 2007
  EUT Received:

h, j, k):                      As indicated in individual tests.

i) Sampling method:            No sampling procedure used.

l) Uncertainty:                In accordance with FTL internal quality manual.

m) Supervised by:




                                                                   Hoosamuddin S. Bandukwala, Lab Director

n) Results:                    The results presented in this report relate only to the item tested.

o) Reproduction:               This report must not be reproduced, except in full, without written permission
                               from this laboratory.




Flom Test Labs
3356 N. San Marcos Place, Suite 107                                                             Page 1 of 11
Chandler, Arizona 85225-7176                                                              p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                            List Of General Information Required For Certification

                                   In Accordance with FCC Rules and Regulations,
                                              Volume II, Part 2 and to

                                                        15.249

Sub-Part 2.1033
(c)(1):

Name and Address of Applicant:             International Electronics Inc.


(c)(2):   FCC ID:                          JLFPTE1

          Model Number:                    Push to Exit

(c)(3):   Instruction Manual(s):

                          Please See Attached Exhibits


(c)(4):   Type of Emission:                N/A


(c)(5):   FREQUENCY RANGE, MHz:            902 to 928


(c)(6):   Power Rating, dBuV/m:            93.3
                      Switchable                          Variable            X    Low Power


(c)(7):   Maximum Power Rating, dBuV/m:                              93.97

15.203: Antenna Requirement:
                                       X    The antenna is permanently attached to the EUT
                                            The antenna uses a unique coupling
                                            The EUT must be professionally installed
                                            The antenna requirement does not apply

The unit was tested with a quarter wave stub antenna with a gain of 3.0 dBi.




Flom Test Labs
3356 N. San Marcos Place, Suite 107                                                            Page 2 of 11
Chandler, Arizona 85225-7176                                                             p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


Subpart 2.1033 (continued)

(c)(8):   Circuit Diagram/Circuit Description:
                  Including description of circuitry & devices provided for determining and stabilizing frequency, for
                  suppression of spurious radiation, for limiting modulation and limiting power.

                           Please See Attached Exhibits


(c)(9):   Label Information:

                           Please See Attached Exhibits


(c)(10): Photographs:

                           Please See Attached Exhibits


(c)(11): Digital Modulation Description:

                           ___ Attached Exhibits
                           _x_ N/A


(c)(12): Test And Measurement Data :

                           Follows




Flom Test Labs
3356 N. San Marcos Place, Suite 107                                                                  Page 3 of 11
Chandler, Arizona 85225-7176                                                                   p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


Sub-part
2.1033(b):                                 Test And Measurement Data

       All tests and measurement data shown were performed in accordance with FCC Rules and Regulations,
Volume II; Part 2 and the following individual Parts:

       15.249        Operation within bands 902 - 928 MHz


                                           Standard Test Conditions
                                                     and
                                             Engineering Practices



        Except as noted herein, the following conditions and procedures were observed during the testing:


          In accordance with ANSI C63.4-2004, and unless otherwise indicated in the specific measurement
results, the ambient temperature of the actual EUT was maintained within the range of 10° to 40°C (50° to 104 °F)
unless the particular equipment requirements specify testing over a different temperature range. Also, unless
otherwise indicated, the humidity levels were in the range of 10% to 90% relative humidity.


         Prior to testing, the EUT was tuned up in accordance with the manufacturer's alignment procedures. All
external gain controls were maintained at the position of maximum and/or optimum gain throughout the testing.


        Measurement results, unless otherwise noted, are worst-case measurements.




A2LA

“A2LA has accredited Flom Test Labs, Inc. Chandler, AZ for technical competence in the field of Electrical
testing. The accreditation covers the specific tests and types of tests listed on the agreed scope of
accreditation. This laboratory meets the requirements of ISO 17025:2005 ‘General Requirements for the
Competence of Testing and Calibration Laboratories’ and any additional program requirements in the
identified field of testing.”

Please refer to www.a2la.org for current scope of accreditation.

Certificate number: 2152.01




                         IC O.A.T.S. Number:          2044A-1

Flom Test Labs
3356 N. San Marcos Place, Suite 107                                                             Page 4 of 11
Chandler, Arizona 85225-7176                                                              p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                                           Test Results Summary


      Specification                        Test Name              Pass, Fail,     Comments
                                                                     N/A
        15.249(a)           Field Strength of Fundamental           Pass
        15.249(a)           Field Strength of Harmonics             Pass
         15.249             Radiated Spurious Emissions             Pass




Flom Test Labs
3356 N. San Marcos Place, Suite 107                                                   Page 5 of 11
Chandler, Arizona 85225-7176                                                    p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


 Name of Test:                     Field Strength of Fundamental
 Specification:                    15.249(a)
 Test Equipment Utilized           i00228, i00317

                                                  Test Procedure


 15.249(a) The field strength of emissions from intentional radiators operating in the 903 – 928 band shall comply
 with the following:


         Fundamental frequency, MHz             Field strength of fundamental,       Field strength of harmonics,
                                                          mV / meter                           uV /meter
                     902 - 928                                50                                  500


 1mV = 1000uV 50000uV/mtr converts to 93.97 dBuV/mtr (20X log(E))

                 500uV/mtr converts to 74.0 dBuV/mtr (Peak)
                                       54.0 dBuV/mtr (Avg)

 The UUT was tested on an Open Area Test Site (OATS) set 3 meters from the receiving antenna. A spectrum
 analyzer was used to verify the UUT met the requirements for Radiated Spurious Emissions. The UUT was
 tested with the appropriate antenna in both the vertical and horizontal orientation and raised from 1 to 4 meters
 while rotating the UUT 360° to ensure the TX signal levels were maximized.
                                                     Test Setup


                                     Spectrum                            UUT
                                     Analyzer



                                       Field Strength of Fundamental table


  Tuned        Emission           Recorded            Correction         Corrected             Specification    Result
Frequency     Frequency          Measurement,         factor, dB        Measurement,          Limit, dBuV/m
   MHz           MHz               dBuV/m                                 dBuV/m
903.000000    903.131000             63.6                28.5               92.1                   93.97         Pass
915.000000    915.695000             64.0                29.3               93.3                   93.97         Pass
926.000000    926.750000             61.0                29.7               90.7                   93.97         Pass




 Flom Test Labs
 3356 N. San Marcos Place, Suite 107                                                                Page 6 of 11
 Chandler, Arizona 85225-7176                                                                 p0690002, d0780025
 (866) 311-3268 phone, (480) 926-3598 fax


 Name of Test:                    Field Strength of Harmonics
 Specification:                   15.249
 Spec. Limit:
 Test Equipment Utilized          i00029, i00329
                                                Test Procedure

 The UUT was tested on an Open Area Test Site (OATS) set 3 meters from the receiving antenna. A spectrum
 analyzer was used to verify the UUT met the requirements for Radiated Spurious Emissions. The UUT was
 tested with the appropriate antenna in both the vertical and horizontal orientation and raised from 1 to 4 meters
 while rotating the UUT 360° to ensure the TX signal levels were maximized
 .
 Only the worst case is recorded in the Field Strength of Harmonics table.

                                                   Test Setup

                        UUT                     Antenna                     Spectrum
                                                                            Analyzer

                                      Field Strength of Harmonics Table
 903MHz
   Tuned        Emission         Recorded            Corrected         Corrected            Specification    Result
 Frequency     Frequency        Measurement,         level, dB        Measurement,         Limit, dBuV/m
    MHz           MHz             dBuV/m                                dBuV/m                  Peak
903.000000    1806.360000            4.1                34.2              38.3                   74.0         Pass
903.000000    2710.330000            0.1                38.7              38.8                   74.0         Pass
903.000000    3612.542000           -0.6                42.6              42.0                   74.0         Pass
903.000000    4515.014000           -1.6                37.6              36.0                   74.0         Pass
903.000000    5419.580000           -0.5                40.3              39.8                   74.0         Pass
903.000000    6321.326000            4.3                41.4              45.7                   74.0         Pass

 915MHz
  Tuned         Emission         Recorded            Corrected         Corrected            Specification    Result
Frequency      Frequency        Measurement,         level, dB        Measurement,         Limit, dBuV/m
   MHz            MHz             dBuV/m                                dBuV/m                  Peak
915.000000    1831.470000            4.5                30.9              35.4                   74.0         Pass
915.000000    2746.962000           -0.2                34.5              34.3                   74.0         Pass
915.000000    3662.592000           -0.4                36.4              36.0                   74.0         Pass
915.000000    4578.168000           -0.1                37.8              37.7                   74.0         Pass
915.000000    5493.774000           -0.1                40.4              40.3                   74.0         Pass
915.000000    6409.444000            4.7                41.6              46.3                   74.0         Pass

 927MHz
  Tuned       Emission           Recorded       Corrected       Corrected          Specification     Result
Frequency    Frequency        Measurement,      level, dB     Measurement,        Limit, dBuV/m
   MHz          MHz               dBuV/m                         dBuV/m                Peak
927.000000 1853.572000               7.1           31.0            38.1                 74.0         Pass
927.000000 2780.132000              -1.6           34.7            33.1                 74.0         Pass
927.000000 3706.854000              -0.9           36.5            35.6                 74.0         Pass
927.000000 4633.396000               0.2           38.0            38.2                 74.0         Pass
927.000000 5560.030000               0.5           40.5            41.0                 74.0         Pass
927.000000 6486.904000               5.0           41.7            46.7                 74.0         Pass
                                 th                                                               th
 The EUT was tested out to the 10 harmonic. There were no observable spurious emissions past the 6
 harmonic. The measurements all were below the 54dBuV (average) value as a peak value.

 Flom Test Labs
 3356 N. San Marcos Place, Suite 107                                                             Page 7 of 11
 Chandler, Arizona 85225-7176                                                              p0690002, d0780025
 (866) 311-3268 phone, (480) 926-3598 fax


Name of Test:                    Radiated Spurious Emissions
Specification:                   15.249(c), 15.209(a), 15.205
Spec. Limit:
Test Equipment Utilized          i00029, i00033, i00088, i00089, i00103

                                                Test Procedure

The UUT was tested on an Open Area Test Site (OATS) set 3 meters from the receiving antenna. A spectrum
analyzer was used to verify the UUT met the requirements for Radiated Spurious Emissions. The UUT was
tested with the appropriate antenna in both the vertical and horizontal orientation and raised from 1 to 4 meters
while rotating the UUT 360° to ensure the TX signal levels were maximized.

                                                   Test Setup


                        UUT                    Antenna                     Spectrum
                                                                           Analyzer

Settings
RBW = 100 KHz
VBW = 100KHz
Detector – Quasi Peak

Sample Calculations

Corrected Level = Recorded Level + Correction factor

Correction factor = ACF + Cable loss + Distance Correction factor

Distance Correction factor = 10 log D1/D2




                                        Radiated Spurious Emissi ons

Tuned Freq     Emission Freq     Monitored Level     Correction Factor    Corrected Value      Limit      Result
  (MHz)           (MHz)            (dBuV/m)                (dB)              (dBuV/m)        (dBuV/m)
915.000000      34.232230             18.2                 13.6                31.8            40.0        Pass
915.000000      178.514740            16.5                 15.7                32.2            40.0        Pass
915.000000      350.104000            16.1                 17.8                33.9            46.0        Pass
915.000000      581.911470            16.2                 22.8                39.0            46.0        Pass
915.000000      649.782800            17.0                 23.6                40.6            46.0        Pass
915.000000      819.800000            16.1                 25.5                41.6            46.0        Pass




Flom Test Labs
3356 N. San Marcos Place, Suite 107                                                             Page 8 of 11
Chandler, Arizona 85225-7176                                                              p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                                              Band Edge Plots




This picture contains a plot of the hi frequency modulated carrier with a marker on the peak. Then a marker
delta was set and dialed out to the band edge (green tag on the graph) The resultant delta is the difference
from the ambient noise floor to the peak signal (for this graph 50.84 db below the carrier peak)




Flom Test Labs
3356 N. San Marcos Place, Suite 107                                                           Page 9 of 11
Chandler, Arizona 85225-7176                                                            p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


Band Edge Plots (cont)




This picture contains a plot of the hi frequency modulated carrier with a marker on the peak. Then a marker
delta was set and dialed out to the band edge (green tag on the graph) The resultant delta is the difference
from the ambient noise floor to the peak signal (for this graph 50.16 db below the carrier peak)




Flom Test Labs
3356 N. San Marcos Place, Suite 107                                                           Page 10 of 11
Chandler, Arizona 85225-7176                                                            p0690002, d0780025
(866) 311-3268 phone, (480) 926-3598 fax


                                            Test Equipment Utilized

     Description         MFG           Model Number          FTL Asset Number       Last Cal Date    Cal Due Date
 Bi-conical Antenna     EMCO              3109B                   i00088              10/14/05         10/14/07
Log Periodic Antenna     Aprel             2001                   i00089              10/20/05         10/20/07
    Horn Antenna        EMCO               3115                   i00103                9/5/06          9/5/07
 Spectrum Analyzer        HP              8566B                   i00329               4/16/07         4/16/08

  In addition to the above listed equipment standard RF connectors and cables were utilized in the testing of the
  described equipment. Prior to testing these components were tested to verify proper operation.




  END OF TEST REPORT




  Flom Test Labs
  3356 N. San Marcos Place, Suite 107                                                           Page 11 of 11
  Chandler, Arizona 85225-7176                                                            p0690002, d0780025
  (866) 311-3268 phone, (480) 926-3598 fax



Document Created: 2007-11-21 10:06:45
Document Modified: 2007-11-21 10:06:45

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC