Chapter 3

FCC ID: JEH7710GA2

Users Manual

Download: PDF
FCCID_48894

3




    Preparing the Installation Site


    Preparing the Site
                This chapter provides the following information:
                •   A summary of customer responsibilities prior to installation
                •   Power, grounding, and distribution requirements of the DecisioNet
                    System
                •   DecisioNet System environmental requirements
                •   DecisioNet System component characteristics


3-2   Preparing the Installation Site




Customer Responsibilities
                             The customer must do or provide the following:
                             •     When required by NCR, provide the NCR customer service
                                   representative with appropriate drawings that indicate:
                                   •    Fixture Plan showing the location of store fixtures
                                   •    Floor Plan showing the location of all interior walls, ceiling
                                        heights, and firewalls
                                   •    Site wiring diagrams for power and communication
                                   •    Location of other equipment capable of generating electrical
                                        noise, electromagnetic interference, heat, etc.
                                   •    Environmental conditions that could affect RF communication
                             •     Make building alterations necessary to meet wiring and other site
                                   requirements
                             •     Provide and install all communications cables, wall jacks, special
                                   connectors, and associated hardware
                             •     Provide and install necessary power distribution boxes, conduits,
                                   grounds, lightning protection, and associated hardware
                             •     Provide and install auxiliary power or other equipment as required
                             •     Provide storage or service areas as required
                             •     Make sure that the environmental requirements discussed in this
                                   chapter are met
                             •     Provide floor coverings and environmental systems that limit or
                                   control static electricity build-up and discharge

                             Warning: Make sure all applicable codes, regulations, and laws
                             (including, but not limited to, electrical, building, safety, and health)
                             are met.


                                                            Preparing the Installation Site   3-3




Power, Grounding and Distribution Requirements
             Voltage transients, line noise, surges, sags, impulses, and spikes can
             happen routinely or sporadically. When such phenomena occur,
             protective devices such as surge protectors may help to ensure proper
             operation of the equipment.

Power Requirements
             The CBS does not have an internal power supply. It receives +60V DC
             from an external power supply (7710-K100). Each power supply can
             support up to five CBSs.
             For maximum system integrity, install the power supply(s) on a
             dedicated branch circuit from a distribution panel that does not supply
             any switched inductive loads (motors, air conditioners, etc.). Do not
             connect anything else to this branch circuit except other DecisioNet
             System equipment.
             Each power supply circuit should consist of three conductors,
             including separate wires for the line, neutral, and insulated ground
             connections to the distribution panel.
             The specifications for the CBS power supply are as follows:


              Voltage                    100 to 240 Volts
              Current                    1.1 to 2.2 Amps
              Watts                      130 Watts
              Frequency                  50 or 60 Hz


3-4   Preparing the Installation Site




Grounding Requirements
                             Because the DecisioNet System connects logic reference ground to
                             safety ground, a noise-free grounding circuit is necessary for good
                             system integrity.
                             Use an isolated ground receptacle, such as a Hubbell IG-5262 or
                             equivalent. Make sure the ground conductor is insulated from conduit
                             and neutral wire, and that it is connected to an insulated terminal strip
                             at the distribution panel. DO NOT use this dedicated insulated ground
                             wire as a neutral.
                             DO NOT use a conduit as a ground. Resistance at the conduit joints
                             may create multiple ground levels within the electrical power
                             distribution system and degrade the reliability of the DecisioNet
                             System.


Power Distribution Requirements
                             The following power distribution requirements must be met to
                             minimize the effects of electrical noise generated by equipment outside
                             of the DecisioNet System:
                             •     Give consideration to voltage drops in the power distribution
                                   system caused by wiring, circuit breakers, terminal blocks, etc..
                                   Verify that the voltage at the receptacle is within the specifications
                                   on the power supply and that all applicable national, state, and
                                   local codes are met.
                             •     All wire connections must be electrically and mechanically sound
                                   and protected from deterioration. Deterioration of wire connections
                                   due to corrosion or electrolysis, especially in a humid or corrosive
                                   atmosphere, may result in electrical noise and/or a safety hazard.


                                                       Preparing the Installation Site   3-5



The following illustration shows an example of site wiring.
                                          Circuit
 Hubbel IG5262                            Breaker
 Receptacle or
 equivalent is          Black (Li)
                                              15 A
 recommended
                        Green (Ground)
                        White (Neutral)

 Power Supply
 for CBS 1
 through CBS 5
                         Conduit


                                                Li

                                                N
                                                              Neutral
 Power Supply
                                                Building
 for CBS 6
                                                Service
 through CBS 10
                                                Entrance




 Power Supply
 for CBS 11
 through CBS 15




 Power Supply
 for CBS 16
 through CBS 20                                                 14494




Note: The distribution panel must not furnish power to any inductive
loads such as refrigeration equipment, ovens, and motors.


3-6   Preparing the Installation Site




Environmental Requirements
                             CBSs, SmarTalkers, and SmarTalker IIs operate across a wide range of
                             environmental conditions as shown in the following tables. Avoid
                             using them in continuous operation at or near the temperature limits
                             shown in the tables or in a location where the temperature or humidity
                             may go beyond the limits indicated.
                             Due to lower atmospheric pressure and air rarefaction at high
                             altitudes, the maximum dry bulb temperature for each working range
                             is decreased linearly by a value of 3.3 °C /1,000m (1.8 °F /1,000 ft.)
                             between the altitude of 500m (1,640 ft.) and 3,000 m (9,840 ft.).


Temperature and Humidity
                             The environmental requirements for the CBS, SmarTalker, and
                             SmarTalker II tags are shown in the following tables.

                             CBS
                               Operating              Transit                 Storage
 Temperature                   0°C to 40°C            -20°C to 60°C           -10°C to 50°C
 (Dry bulb)                    (32°F to 122°F)        (-4°F to 140°F)         (14°F to 122°F)
 Max. Temp.        10°C (18°F)                        20°C (36°F)             15°C (27°F)
 Change per Hour
 Relative Humidity 10% to 80%                         5% to 95%               10% to 90%
                   No Condensation                    No Condensation         No Condensation
 Max. Humidity     10%                                10%                     10%
 Change per Hour
 Barometric        105 to 79.5 kilo pascals           105 to 74.0 kilo        105 to 79.5 kilo
 Pressure          (up to a max. of 2000              pascals (up to a max.   pascals (up to a max.
                   m (6560 ft.))                      of 2500 m (8200 ft.))   of 2000 m (6560 ft.))


                                                                    Preparing the Installation Site   3-7




                   SmarTalker
                     Operating                 Transit                  Storage
Temperature          0°C to 40°C               -20°C to 60°C            -10°C to 50°C
(Dry bulb)           (32°F to 104°F)           (-4°F to 140°F)          (14°F to 122°F)
Max. Temp. Change 10°C (18°F)                  20°C (36°F)              15°C (27°F)
per Hour
Relative Humidity   10% to 90%                 5% to 95%                5% to 90%
                    No condensation            No condensation          No condensation
Max. Humidity       10%                        10%                      10%
Change per Hour
Barometric Pressure 105 to 79.5 kilo pascals   105 to 74.0 kilo      105 to 79.5 kilo
                    (up to a max. of 2000      pascals (up to a max. pascals (up to a max.
                    m (6560 ft.))              of 2500 m (8200 ft.)) of 2000 m (6560 ft.))



                   SmarTalker II (Standard Size and Small Size)
                     Operating                 Transit                  Storage (3 months maximum)
Temperature          -20°C to 40°C             -20°C to 60°C            -10°C to 50°C
(Dry bulb)           (-4°F to 104°F)           (-4°F to 140°F)          (14°F to 122°F)
Max. Temp. Change 10°C (18°F)                  20°C (36°F)              15°C (27°F)
per Hour
Relative Humidity   10% to 90%                 5% to 95%                5% to 90%
                    No condensation            No condensation          No condensation
Max. Humidity       10%                        10%
Change per Hour
Barometric Pressure 105 to 70 kilo pascals     105 to 70 kilo pascals
                    (up to a max. of 3000      (up to a max. of 3000
                    m (9842 ft.))              m (9842 ft.))


3-8   Preparing the Installation Site




                             SmarTalker II (Signage)
                                 Operating             Transit (1 week maximum)   Storage (3 months maximum)
Temperature                      0°C to 40°C           -20°C to 60°C              -10°C to 50°C
(Dry bulb)                       (32°F to 104°F)       (-4°F to 140°F)            (14°F to 122°F)
Max. Temp. Change 10°C (18°F)                          20°C (36°F)                15°C (27°F)
per Hour
Relative Humidity   10% to 90%                         5% to 95%                  5% to 90%
                    No condensation                    No condensation            No condensation
Max. Humidity       10%
Change per Hour
Barometric Pressure 105 to 70 kilo pascals             105 to 70 kilo pascals
                    (up to a max. of 3000              (up to a max. of 3000
                    m (9842 ft.))                      m (9842 ft.))


                                                                       Preparing the Installation Site   3-9




Altitude and Temperature
              The following graph shows how altitude affects the operating
              temperature of CBSs and SmarTalkers. As altitude increases, the
              maximum operating temperature decreases.
                  Maximum operating
                    temperature
                       C ( F)



                      45 (113)




                      40 (104)




                       35 (95)




                      30 (86)




                       25 (77)



                                                                                 Altitude
                                      500       1,000     2,000     3,000         meters
                                      (1,640)   (3,280)   (6,560)   (9,840)       (feet)




Health and Safety
              CBSs meet the following safety and radio frequency interference
              requirements.
              •     ANSI C95.1-1990
              •     UL 1950
              •     UL 2043
              •     CSA C22.2 No. 950
              •     FCC Class A
              •     FCC Part 15.249
              •     DOC Class A


3-10   Preparing the Installation Site




Component Characteristics

CBS
                              The CBS weighs 5.0 kg (11.0 lb.). The following illustration shows the
                              dimensions of the CBS.




                               107.9 mm                     279.4 mm
                               (4.25 in.)                    (11 in.)




                                  304.8 mm
                                   (12 in.)




                                                                                   35 mm
                                                                                  (1.37 in.)

                                                                                           14416




                              Note: Some CBSs may have minor cosmetic differences.


                                                   Preparing the Installation Site   3-11



The CBS does not have ventilation holes, but it does require the service
clearances indicated in following table.


 Direction   Distance in mm   Distance in inches
 Top         380              15.0
 Bottom      100              3.9
 Right       100              3.9
 Left        100              3.9
 Front       915              36
 Back        0                0


3-12   Preparing the Installation Site




Power Supply
                              The power supply weighs 1.5 kg (3.31 lb.). The following illustration
                              shows the dimensions of the power supply.




                                69.0 mm
                                (2.72 in.)
                                             197.0 mm
                                             (7.76 in.)                   225.0 mm
                                                                          ( 8.86 in.)



                                                                                        13191




                              The power supply has rear ventilation holes, so it requires the air flow
                              and service clearances indicated in the following table.


                               Direction      Distance in mm   Distance in inches
                               Top            100              3.9
                               Bottom         0                0
                               Right          100              3.9
                               Left           100              3.9
                               Front          100              3.9
                               Back           100              3.9


                                                               Preparing the Installation Site   3-13




Transmit Antenna
             The transmit antenna weighs 0.71 kg (1.57 lb.). The following
             illustration shows the dimensions of the transmit antenna.




                                                       65.0 mm
                                                       (2.56 in.)




                                          304.8 mm
                                          (12.0 in.)

                                                                     13186




Receive Antenna
             The receive antenna weighs 0.71 kg (1.57 lb.). The following illustration
             shows the dimensions of the receive antenna.




                                                        65.0 mm
                                                        (2.56 in.)




                                          304.8 mm
                                          (12.0 in.)


                                                                     13189


3-14   Preparing the Installation Site



Patch Antenna
                              The patch antenna weighs 0.0454 kg (0.1 lb.). The following illustration
                              shows the dimensions of the patch antenna.

                                                          48 mm
                                                          1.88 in.




                                                                        9 mm
                                         64 mm
                                                                        .38 in.
                                         2.5 in.




                                                                                  13 mm
                                                                                   .5 in.

                                               45 mm         45 mm
                                               1.75 in.      1.75 in.
                                                                                            16126


                                                            Preparing the Installation Site   3-15




SmarTalker
             This section describes the physical characteristics of SmarTalkers.
             SmarTalkers are available in two sizes:
             •   The standard-size SmarTalker (on the left below) weighs 0.039 kg
                 (0.086 lb.).
             •   The small–size SmarTalker (on the right below) weighs 0.028 kg
                 (0.063 lb.).



                                100.0 mm                      60.0 mm
                                (3.94 in.)                    (2.38 in.)
                                                                           35.2 mm
                                                                           (1.39 in.)


                                                                          14.2 mm (0.56 in.)

                                                                                          14517




             SmarTalker Displays and Symbols
             The SmarTalker displays are shown in the following illustrations. The
             symbols on the displays are explained in the table following the
             illustrations.




                                                                  15762



             Standard Size


3-16   Preparing the Installation Site




                                                                                             15763

                              Small Size



                              ● Lights when the SmarTalker is out of synchronization for RF
                                communication.
                                    Lights when the battery is low.
                              ▲ Available for use in the user application or can be selected using
                                the Promotions option in EPL Maintenance.
                              ■ Available for use in the user application or can be selected using
                                the Promotions option in EPL Maintenance.


                              For SmarTalker configuration information refer to the NCR DecisioNet
                              System User’s Guide (B005-0000-1087).


                                                                                 Preparing the Installation Site   3-17




SmarTalker II
                This section describes the physical characteristics of SmarTalker IIs.
                SmarTalker IIs are available in three sizes:
                •   The 8-character and 2x6-character SmarTalker II standard-size tags
                    have the same physical dimensions and weight 0.035 kg (0.077 lb.).
                •   The 2x4-character and 2x5-character SmarTalker II small-size tags
                    have the same physical dimensions and weight 0.025 kg (0.055 lb.).
                •   The 1x6-character SmarTalker II signage tag weighs 75 g (0.16 lb.).


                                                                     35 mm
                                                                    (1.38 in.)



                                         100 mm                                                 8.7 mm
                                         (3.94 in.)                                             (.34 in.)
                                                                                               13.2 mm
                                                                                               (.52 in.)

                                                                                                     16913

                SmarTalker II, Standard Size




                                                        35 mm
                                                      (1.38 in. )


                                                                                                8.7 mm
                                   60 mm
                                                                                                (.34 in.)
                                  (2.36 in.)
                                                                                               13.2 mm
                                                                                               (.52 in.)

                SmarTalker II, Small Size                                                             16914


3-18   Preparing the Installation Site



                                                                                      14.1 mm
                                             58.3 mm
                                             (2.3 in.)                                (.56 in.)



                                                                                       45 mm
                                                                                       (1.7 in.)



                                                             160 mm
                                                             (6.3 in.)                               17062



                              SmarTalker II, Signage


                              SmarTalker II Displays and Symbols

                              The SmarTalker II displays are shown in the following illustrations.
                              The symbols on the displays are explained in the table following the
                              illustrations.




                              8-Chararacter, Standard Size




                              2x6-Chararacter, Standard Size




                              2x4-Chararacter, Small Size


                                                   Preparing the Installation Site   3-19




2x5-Chararacter, Small Size




                                           17063


1x6-Chararacter, Signage



  ●      Lights when the SmarTalker II is out of synchronization for
         RF communication.
         Lights when the battery is low.
         Indicates that the message on the LCD refers to the wording
         on the overlay or the items above the tag.
         Indicates that the message on the LCD refers to the wording
         on the overlay or the items to the left of the tag.
         Indicates that the message on the LCD refers to the wording
         on the overlay or the items below the tag.

         Lights to attract more attention to the message on the tag.
         Cents currency symbol

         Euro currency symbol


For SmarTalker II configuration information refer to the NCR
DecisioNet System User’s Guide (B005-0000-1087).


3-20   Preparing the Installation Site




Weight and Dimension Table
                              The dimensions and weights of DecisioNet System components are
                              shown in the following table.


 Unit and Related Components             Height mm (in.)   Width mm (in.)   Depth mm (in.)   Weight kg (lb.)
 CBS                                     304.8 (12.0)      279.4 (11.0)     107.9 (4.25)     5.0 (11.0)
 Power Supply                            69.0 (2.72)       225.0 (8.87)     197.0 (7.76)     1.5 (3.31)
 Transmit Antenna                        65.0 (2.56)       304.8 (12.00)*                    0.71 (1.57)
 Receive Antenna                         65.0 (2.56)       304.8 (12.00)*                    0.71 (1.57)
 Patch Antenna                           64.0 (2.50)       45 (1.75)        45 (1.75)        0.054 (0.1)
 SmarTalker                              35.2 (1.39)       100.0 (3.94)     14.2 (0.56)      0.039 (0.086)
 8-character,
 standard size
 SmarTalker                              35.2 (1.39)       60.0 (2.36)      14.2 (0.56)      0.028 (0.063)
 8-character,
 small size
 SmarTalker II                           35 (1.38)         100 (3.94)       22 (0.87)        0.035 (0.077)
 8- and 2x6-character,
 standard size
 SmarTalker II                           35 (1.38)         60 (2.36)        22 (0.87)        0.025 (0.055)
 2x4- and 2x5-character,
 small size
 SmarTalker II                           45 (1.77)         160 (6.29)       14.1 (0.55)      0.075 (0.165)
 1x6-character, signage
                                                           * Diameter



Document Created: 2001-06-11 06:54:40
Document Modified: 2001-06-11 06:54:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC