                                                                                                                                                                     4. Mount the Wireless VITRON on the required location (wall or
                                                                      3 Mounting Location                                                                               ceiling) using the supplied screws (2, Fig 8). Do not tighten the
                                                                                                                                                                        screws.
                                                                      For optimal performance the Wireless VITRON should be mounted as
                                                                                                                                                                     5. Adjust the detector so it will face the protected glass.
                                                                      nearly opposite to the glass area to be protected, as shown in Fig 3.
                                                                                                                                                                     6. Tighten the bolts to the final torque.
                                                                      Attach the Glassbreak detector to the surface using the adhesive strips.
                        Model: RWT6G                                                           • Opposite Wall –Mounted (For optimal
                                                                                                 results, Wireless VITRON is centered                                6 Quick Device Allocation at the Control Panel
                                                                                                 opposite glass, see Fig. 3).
                                                                                                           VITRON
                                                                                                                                                                     The Glassbreak detector is automatically programmed to your control
                                                                                                                                                                     panel during the on-line installation wizard setup. If you later
                Installation instructions                                    Fig. 3                                                                                  purchase an extra detector you can enroll it as follows:
                                                                                                                                                                     To quickly allocate the detector at the control panel:
                                                                                                                     • Ceiling Mounted (for optimal results
                                                                                                                                                                     If the control panel is not already in Learn mode, press the
                                                                                                                       Wireless VITRON is centered and directed
                                                                                                                       towards protected glass, using the supplied         button on the control panel for 5 seconds; the unit beeps once
                                                                             VITRON



                                                                                                          VITRON       swivel adaptor, see fig. 4)                   as it enters Learn mode (all the LEDs also light up, one after the
                                                                                                                                                                     other).
                                                                             Fig. 4                                                                                  Remove the plastic wrapping from the batteries before installation
                                                                                                                                                                     and make sure the cover is removed so the internal tamper switch is
                                                                                                                     • Corner Mounted (choose corner opposite        accessible.
                                                                                                                       glass to be protected see fig. 5)             Send a signal transmission from the detector by pressing the tamper
                                                                                                                                                                     button for at least 2 seconds; the control panel beeps once to accept
1 General Description
                                                                             VITRON   VI TRO N




                                                                                                                                                                     or beeps three times to reject. Once accepted, the system
                                                                                                 VITRON




                                                                                                           VI TRON




                                                                                                                                                                     announces the device type and its zone (for example, “Detector,
The Wireless VITRON is an advanced microprocessor based                      Fig. 5                                                                                  zone 1”).
Acoustic Glass Break detector. The Wireless VITRON detects the                                                                                                       When the detectors have been enrolled, short-press the control
breaking of most common types of framed glass panes while                                                            • Side wall – mounted not recommended
ignoring false alarms.                                                                                                 due to the fact that the Wireless VITRON is   panel button        to exit Learn mode; the unit beeps once and the
                                                                                                                                                                     LEDs stop flashing.
                                                                                                                       not opposite the glass - see range versus
                                                                                                                                                                     Note: For future use, it is recommended to write down the detector
                                                                                                                       angle diagram (Fig 2).
                                                                             VITRON   VITRON




2 Installation Procedure                                                                                                                                             description, zone number, and installation location of each allocated
                                                                             Fig. 6                                                                                  detector.
Note: To improve detection, It is highly recommended to use a         Notes:
swivel adaptor, especially for ceiling and wall installations.
                 45°
                                                                      Do not mount Wireless VITRON on same wall as the protected glass.                              7 Jumpers settings
             60°     30°               Fig 1: Percentage of Maximum   Avoid installing the Wireless VITRON near sources of loud noise or
         75°                           Range as a function of angle   vibrations (air conditioners, fans, compressors, stereos, etc).                                Please do not change the jumper settings.
                          15°
                                       between Wireless VITRON and    Avoid defining the Wireless VITRON as a 24 hour zone
                            0°
                                       glass.                         The Wireless VITRON should always be installed in addition to                                  8 Technical Specifications
                                                                      standard motion detectors
                                                                                                                                                                       Electrical
     WIRELESS
      VITRON                                                                                                                                                           Current consumption             22 uA at 3 VDC, without acoustic
                                                                      4 Mounting                                                                                       (standby)                       signal
Verify that the distance between the Wireless VITRON and the
furthest point on the protected glass does not exceed the maximum     Use the two-sided adhesive tape to attach the detector to the surface.                           Current consumption             10 mA at 3 VDC
specified range taking into account the reduced range due to angle                                                                                                     (Alarm transmission)            (Max. with LED OFF)
(see Fig 2).                                                          5 Swivel Mounting                                                                                                                15 mA at 3 VDC
                                      Fig 2: Angle between Wireless                                                                                                                                    (Max. with LED ON)
                                      VITRON and glass                When installing the Wireless                                                                     Battery life                    3 years, at 65 minutes supervision
                                                                      VITRON with the supplied swivel                                                                  Range (loss)                    300m (1000 feet)
                                                                      mounting adaptor, maximum                                               2                        Voltage requirements            CR123A 3VDC Lithium Batteries
                                                                      installation flexibility and                                                                     Frequency                       915MHz
                                                                      performance is achieved.                                                                         Physical
                                                                      To install the swivel mounting                                                                   Size                             87 x 50.7 x 28.6 mm
Other factors affecting range:                                        adaptor perform the following:                                                                   (LxWxD)                          (3.4 x 2.0 x 1.1 in.)
• There should be no obstructions between the Wireless VITRON         1. Remove the PCB from the
  and the protected glass.                                                                                                                                             Environmental
                                                                         Wireless VITRON back plate                                                                    Operating/Storage                0°C to 50°C (-32°F to 122°F)
• Curtains and blinds may reduce the effective range.                 2. Open the swivel mounting
• Sound absorbing materials in the protected area may reduce the                                                                                                       temperature
                                                                         adaptor knockouts (4, Fig 7).
  range.
                                                                                                                                          1
                                                                                                                                                                       * Specifications are subject to change without prior notice
                                                                      3. Attach the swivel mounting
                                                                         adaptor to the back plate using                                          Fig. 8             Note: The detector contains a swivel.
                                                                         the two supplied screws (1, Fig


RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from
defects in materials and workmanship under normal use for 24 months from the date of
production. Because Seller does not install or connect the product and because the product may
be used in conjunction with products not manufactured by the Seller, Seller can not guarantee
the performance of the security system which uses this product. Sellers' obligation and liability
under this warranty is expressly limited to repairing and replacing, at Sellers option, within a
reasonable time after the date of delivery, any product not meeting the specifications. Seller
makes no other warranty, expressed or implied, and makes no warranty of merchantability or of
fitness for any particular purpose. In no case shall seller be liable for any consequential or
incidental damages for breach of this or any other warranty, expressed or implied, or upon any
other basis of liability whatsoever. Sellers obligation under this warranty shall not include any
transportation charges or costs of installation or any liability for direct, indirect, or not be
compromised or circumvented; that the product will prevent any persona; injury or property loss
by intruder, robbery, fire or otherwise; or that the product will in all cases provide adequate
warning or protection. Buyer understands that a properly installed and maintained alarm may
only reduce the risk of intruder, robbery or fire without warning, but is not insurance or a guaranty
that such will not occur or that there will be no personal injury or property loss as a result.
Consequently seller shall have no liability for any personal injury, property damage or loss based
on a claim that the product fails to give warning. However, if seller is held liable, whether directly
or indirectly, for any loss or damage arising from under this limited warranty or otherwise,
regardless of cause or origin, sellers maximum liability shall not exceed the purchase price of the
product, which shall be complete and exclusive remedy against seller. No employee or
representative of Seller is authorized to change this warranty in any way or grant any other
warranty.
WARNING: This product should be tested at least once a week.
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries
according to local regulations.



FCC ID: JE4RWT6G915
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation

Changes or modifications to this equipment which are not expressly approved by
the party responsible for compliance (RISCO Group's.) could void the user's
authority to operate the equipment.

FCC Note
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment on and off, the user is encouraged to try to correct the
interference by one or more of the following measures:

       Reorient or relocate the receiving antenna.
      Increase the separation between the equipment and the receiver.
      Connect the equipment into an outlet on to a different circuit from that to
       which the receiver is connected.