Test Report

FCC ID: JE4KCLP

Test Report

Download: PDF
FCCID_280028

                                                                                 Hermon Laboratories Ltd.
                                                                                 P.O.Box 23
                                                                                 Binyamina 30550, Israel
                                                                                 Tel.+972 46288001
                                                                                 Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                      e-mail: mail@hermonlabs.com
                              Electrical




              ELECTROMAGNETIC EMISSION TEST REPORT
                   ACCORDING TO 47CFR PART 15, SUBPART C § 15.209, 15.207, SUBPART B
                                                 for
                                     Rokonet Electronics Ltd.
                                            EQUIPMENT UNDER TEST:
                                            Proximity keypad
                                           Brand name: ProSys
                                           Model: RP128KCLP




This report is in conformity with and ISO/IEC 17025. The A2LA logo endorsement applies only to the test methods and
the standards that are listed in the scope of Hermon Laboratories accreditation.
The test results relate only to the items tested. This test report must not be reproduced in any form except in full
with the approval of Hermon Laboratories Ltd.
                                                                                                Page 1 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                                                                Hermon Laboratories Ltd.
                                                                                                                                P.O.Box 23
                                                                                                                                Binyamina 30550, Israel
                                                                                                                                Tel.+972 46288001
                                                                                                                                Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                                                                     e-mail: mail@hermonlabs.com




Contents

1      PROJECT INFORMATION .............................................................................................................................................. 3

2      SUMMARY OF TESTS..................................................................................................................................................... 4

3      EUT DESCRIPTION......................................................................................................................................................... 5
    3.1       GENERAL DESCRIPTION ................................................................................................................................................ 5
    3.2       EUT TEST CONFIGURATION .......................................................................................................................................... 5
4      TESTS RESULTS ............................................................................................................................................................ 9
    4.1       FIELD STRENGTH OF FUNDAMENTAL ACCORDING TO § 15.209(A)...................................................................................... 9
    4.2       FIELD STRENGTH OF EMISSION ACCORDING TO §15.209 ................................................................................................ 10
    4.3       CONDUCTED EMISSIONS TEST ACCORDING TO §15.207, 15.107 .................................................................................... 11
    4.4       UNINTENTIONAL RADIATED EMISSIONS TEST ACCORDING TO §15.109.............................................................................. 12
APPENDIX A PLOTS............................................................................................................................................................ 14

APPENDIX B TEST EQUIPMENT USED FOR TESTS ........................................................................................................ 21

APPENDIX C GENERAL INFORMATION ............................................................................................................................ 22
    TEST FACILITY DESCRIPTION ................................................................................................................................................... 22
    ABBREVIATIONS AND ACRONYMS ............................................................................................................................................. 22
    SPECIFICATION REFERENCES .................................................................................................................................................. 22
APPENDIX D TEST EQUIPMENT CORRECTION FACTORS ............................................................................................. 23




                                                                                                                                               Page 2 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                               Hermon Laboratories Ltd.
                                                                               P.O.Box 23
                                                                               Binyamina 30550, Israel
                                                                               Tel.+972 46288001
                                                                               Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                    e-mail: mail@hermonlabs.com




1            Project information
Description of equipment under test
Test items                           LCD proximity keypad with transmitter operating at 125 kHz
Manufacturer                         Rokonet Electronics Ltd.
Brand name                           ProSys
LCD proximity keypad model           RP128KCLP
Receipt date                         March 31, 2002

Applicant information
Applicant’s responsible person       Mr. David Kartoun, Corporate Chief Technology Officer
Company                              Rokonet Electronics Ltd.
Address                              14 Hachoma street
Postal code                          75655
City                                 Rishon Le Zion
Country                              Israel
Telephone number                     +972 39616555
Telefax number                       +972 39616584

Test performance
Project number:                      15061
Location                             Hermon Laboratories
Test started                         March 31, 2002
Test completed                       June 30, 2002
Purpose of test                      Apparatus compliance verification in accordance with emission requirements
Test specifications                  FCC Part 15, subpart C §15.209, 15.207; subpart B, Class B




                                                                                         Page 3 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                                                                                  Hermon Laboratories Ltd.
                                                                                                                                                  P.O.Box 23
                                                                                                                                                  Binyamina 30550, Israel
                                                                                                                                                  Tel.+972 46288001
                                                                                                                                                  Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                                                                                       e-mail: mail@hermonlabs.com




2            Summary of tests
The LCD proximity keypad was found complying with the limits of 47CFR Part 15, §15.209, 15.205, 15.207 and subpart B Class B.
                         Parameter                                   Subclause     C     NC       NT      NA         Tested by        Date tested          Remarks
Intentional radiation, §15.209
Field strength of fundamental                                         15.209(a)    C                                  Mrs. E. Pitt,     May 1,
                                                                                                                     test engineer       2002
Out of band spurious emissions (radiated)                             15.209(c)    C                                  Mrs. E. Pitt,     May 1,
                                                                                                                     test engineer       2002
                                                                                                                    Mr. Y. Neuman,     June 30,
                                                                                                                     test engineer       2002
Conducted emissions                                                       15.207   C                                Mr. Y. Neuman,     June 30,
                                                                                                                     test engineer       2002
Unintentional radiation, §15.107, §15.109
Conducted emissions                                                       15.107   C                                Mr. Y. Neuman,     June 30,
                                                                                                                     test engineer       2002
Radiated emissions                                                        15.109   C                                Mr. Y. Neuman,     June 30,
                                                                                                                     test engineer       2002
General conditions under Part 15
The Intentional radiator operates at 125 kHz.                             15.209   C
The intentional radiator does not operate in the restricted               15.205   C
bands of operation.
The intentional radiator has permanently attached antenna or              15.203   C
antenna that uses a unique coupling to the intentional
radiator.
NOTE: C: The parameter is compliant with the requirements.
      NC: The parameter is not compliant with the requirements.
      NT: The parameter is not tested.
      NA: The test of this parameter is not applicable.

 Test report prepared by:         Ms. N. Averin, certification engineer

                                  Mr. M. Nikishin, EMC group leader

 Test report approved by:         Mr. A. Usoskin, QA manager




                                                                                                                                                          Page 4 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                       Hermon Laboratories Ltd.
                                                                                       P.O.Box 23
                                                                                       Binyamina 30550, Israel
                                                                                       Tel.+972 46288001
                                                                                       Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                            e-mail: mail@hermonlabs.com




3            EUT description

3.1          General description
The EUT, LDC proximity keypad, is a part of an integrated security system that combines wired and wireless alarm
protection for residential and commercial installations, access control and basic home automation systems. The LDC
proximity keypad comprises a transmitter operating at 125 kHz, with integral antenna and powered by 13.8 V DC.
The alarm system has a built-in dialer for communication to a central station, a phone for sending voice notifications and
software for easier system programming.
The system is powered from 15 V AC and equipped with a backup battery.


3.2          EUT test configuration
The keypad ports and lines description is given in Table 3.2.1, the system ports and lines description is depicted in Table
3.2.2, support/test equipment is provided in Table 3.2.3, test configurations are shown in Figures 3.2.1 and 3.2.2.
The system operating frequencies are given in Table 3.2.4 and components description is provided in Table 3.2.5.
The 120 V AC / 15 V AC adapter, manufactured by MIDAS, model AA-5715166, s/n 86110806320, was used during the
system testing.


                                   Table 3.2.1 LCD proximity keypad ports and lines

    Port          Port        Connector type     Quantity        Cable type           Cable          Connected to
    type       description                                       description         length,
                                                                                        m
    Power          AUX        Terminal block         1            0.5 mm                3           DC power supply
    Power          COM        Terminal block         1           24 GAUGE               3           DC power supply
    Signal         BUS        Terminal block         2           24 GAUGE               3          2.2 kΩ termination
                 (RS 485)

                                       Table 3.2.2 Alarm system ports and lines

    Port          Port        Connector type     Quantity        Cable type         Cable            Connected
    type       description                                       description       length,
                                                                                      m
    Power        15 V AC      Terminal block         1           Unshielded          1.5           From EUT to
                                                                                               120VAC/15VAC adapter
    Signal        Control     Terminal block         8           Unshielded         3.5*       From voice unit to voice
                                                                                                      keypad
    Signal        Zone        Terminal block         3           Unshielded         3.5*          2.2 kΩ termination
                (sensors)
    Signal         Bus        Terminal block     4 (2 DC         Unshielded         3.5*       From main control panel
                                                and 2 data)                                     through LCD proximity
                                                                                                  keypad to 16 LEDs
                                                                                                       keypad
    Signal          Bell      Terminal block         2           Unshielded         3.5*          2.2 kΩ termination
    Signal     Output (U02)   Terminal block         2           Unshielded         3.5*             Termination
    Signal      Dry contact   Terminal block         2           Unshielded         3.5*              Shortening
               (Relay, U01)
    Signal      Telephone     Terminal block         2           Unshielded          >3        From main control panel
                                                                                                  to line simulator
*May be up to 300 m.




                                                                                                 Page 5 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                        Hermon Laboratories Ltd.
                                                                                        P.O.Box 23
                                                                                        Binyamina 30550, Israel
                                                                                        Tel.+972 46288001
                                                                                        Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                             e-mail: mail@hermonlabs.com




                                          Table 3.2.3 System support/test equipment

        Description                     Manufacturer                Model number                   Serial number
        Line simulator                  Hermon Labs                     LS-01                           1856

                                           Table 3.2.4 System operating frequencies

        Frequency,                                                    Card ID
           MHz
                                   Main control panel                 Voice unit               LCD proximity keypad

            0.125                                                                                         ●
             8.0                                                          ●                               ●
             16.0                            ●

                                                 Table 3.2.5 System components

                         Component                                            Rokonet catalog number
                     Main control panel                                            RP128MC00ENA
                      16 LEDs keypad                                               RP128KL1600A
                    LCD proximity keypad                                           RP128KCLP00A
                          Voice unit                                               RP128EV00ENA
                         Voice keypad                                              RP128EVM000A
                    Access control module                                          RP128EAC000A


3.2.1        Changes made in equipment
To withstand the standard requirements the following changes were made in the equipment during the testing.
    1)       Two 10 nF capacitors were installed at bus communication interface of main control panel between GRN and
             COM, YEL and COM.
    2)       One 10 nF capacitor was installed at 16 LEDs keypad between AUX and COM.
It is manufacturer responsibility to implement the changes in the production version of the EUT. In any case the test report
applies to the tested items only.




                                                                                                  Page 6 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                  Hermon Laboratories Ltd.
                                                                                  P.O.Box 23
                                                                                  Binyamina 30550, Israel
                                                                                  Tel.+972 46288001
                                                                                  Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                       e-mail: mail@hermonlabs.com




     Figure 3.2.1 EUT configuration for field strength of fundamental and out of band spurious emissions tests




                                                           EUT           Tx
                                          Rx

                                           AUX       COM                   BUS




                                          +          -
                                               DC power
                                                supply               2 kOhm termination




                                                                                           Page 7 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                                                                                 Hermon Laboratories Ltd.
                                                                                                                                                 P.O.Box 23
                                                                                                                                                 Binyamina 30550, Israel
                                                                                                                                                 Tel.+972 46288001
                                                                                                                                                 Fax.+972 46288277
    HE R MON L AB OR AT OR IE S                                                                                                                  e-mail: mail@hermonlabs.com




                                               Figure 3.2.2 EUT configuration for conducted and radiated emissions tests




             EUT
                                   Telephone
  Line                                                                                   Main control panel                                                                   AC mains
simulator
                                                                                                                                                                    120VAC/
                                                                                                                                                                     15VAC
                                                                                                                                                                    adapter

                                                      Voice
                                                       unit
                                                                              Access
               Control (8 wires)




                                                                              control
                                                                              module




                                                                                                                                   Dry contact
                                                                                                                Zone 8



                                                                                                                          Output
                                                                                         Zone 1



                                                                                                       Zone 5




                                                                                                                                                    Bell
                                                 16 LEDs
                                                 keypad                                                                             Shortening


                                                                                                  2.2 kOhm terminations

                                                                             Bus
                                                                         (2 DC wires,                                                            2.2 kOhm termination
                                                                         2 data wires)


                                                LCD proximity keypad                                                     Termination
                                                operating at 125 kHz
                                    Voice
                                   keypad

                                                              Integral
                                                              antenna




                                                                                                                                                            Page 8 of 29
    Document ID: ROKRAD_FCC.15061K.doc
    Date of Issue: July 2002


                                                                                          Hermon Laboratories Ltd.
                                                                                          P.O.Box 23
                                                                                          Binyamina 30550, Israel
                                                                                          Tel.+972 46288001
                                                                                          Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                               e-mail: mail@hermonlabs.com




4               Tests results
4.1             Field strength of fundamental according to § 15.209(a)

METHOD OF MEASUREMENTS:                           ANSI 63.4 §13.1.4
DATE:                                             May 1, 2002
RELATIVE HUMIDITY:                                47 %
AMBIENT TEMPERATURE:                              24 °C
TEST PERFORMED AT:                                OATS
DISTANCE BETWEEN ANTENNA AND EUT:                 10 m
ANTENNA TYPE:                                     LOOP

                                                                            1
    Carrier frequency,        Peak detector   Average detector         Limit ,         Margin,        Reference to Plots
            kHz               measurement,     measurement,              µV/m)
                                                                      dB(µ               dB             in Appendix A
                                   µV/m)
                                dB(µ             dB(µµV/m)
          123.5                   75.3              65.2                84.7             19.5                 A1
    Measurement uncertainty, dB                                                   ±4

1
 The limit is based on measurements employing an average detector according to §15.209(d).
The § 15.35 (b) peak limits (20 dB above average limits) were met since the measurements were performed with peak
detector function.


LIMIT
                 Frequency,                       Specification limit                    Measurement distance,
                    MHz                               dB(µµV/m)                                  m
                0.009 – 0.490                       67.60-20logF*                               300**

* F is frequency in kHz.
**The limit for 10 m distance was calculated using the inverse square distance extrapolation factor as follows:
LimS2 = Lim S1+ 40 log (S1/S2), where S1 = 300 m, S2 = 10 m.

At 125 kHz frequency the limit was calculated:

                                                       µV/m)
Lim10m = 67.60 – 20 log125 + 40 log (300/10) = 84.7 dB(µ


TEST PROCEDURE
The EUT was tested, being placed on a wooden 80 cm height table in each of three orthogonal planes in turn.
The loop antenna was positioned with its plane vertical. The loop center was 1 meter above the ground plane. To find
maximum radiation the turntable was rotated 360° and the measuring antenna was rotated about its vertical axis.


TEST EQUIPMENT USED:
      HL 0813          HL 1430          HL 1552         HL 1915




                                                                                                    Page 9 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                          Hermon Laboratories Ltd.
                                                                                          P.O.Box 23
                                                                                          Binyamina 30550, Israel
                                                                                          Tel.+972 46288001
                                                                                          Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                               e-mail: mail@hermonlabs.com




4.2          Field strength of emission according to §15.209(c)

METHOD OF MEASUREMENTS:                            ANSI 63.4 §13.1.4
DATE:                                              May 1, 2002
RELATIVE HUMIDITY:                                 47 %
AMBIENT TEMPERATURE:                               24 °C
TEST PERFORMED IN:                                 ANECHOIC CHAMBER
DISTANCE BETWEEN ANTENNA AND EUT:                  3m
ANTENNA TYPE:                                      LOOP


Peak detector

           Frequency,                    Radiated                 Limit                Margin,         Reference to Plots
                                         emission,                                                       in Appendix A
                MHz                         µV/m)
                                         dB(µ                      µV/m)
                                                                dB(µ                     dB
                                  All spurious emissions including the third harmonic were found at
           0.009 – 30                                                                                        A2, A3
                                                  least 20 dB below specified limit
 Measurement uncertainty, dB                                                 ±4




LIMIT
         Frequency,                Specification limit         Measurement distance,             Calculated 3m limit**,
             MHz                       dB(µµV/m)                        m                                 µV/m)
                                                                                                       dB(µ
        0.009 – 0.490                67.60-20logF*                     300                          147.60-20logF*
        0.490 – 1.705                87.60-20logF*                      30                          127.60-20logF*
          1.705 - 30                      29.5                          30                               69.5

* F is frequency in kHz.
**The limit for 3 m distance was calculated using the inverse square distance extrapolation factor as follows:
LimS2 = Lim S1+ 40 log (S1/S2), where S1 = 300 m or 30 m, S2 = 3 m.




TEST EQUIPMENT USED:
   HL 0465      HL 0521                  HL 0589           HL 0592           HL 0593             HL 0594         HL 1004
      HL 1915


TEST PROCEDURE
The EUT was tested, being placed on a wooden 80 cm height table in each of three orthogonal planes in turn.
The loop antenna was positioned with its plane vertical. The loop center was 1 meter above the ground plane. To find
maximum radiation the turntable was rotated 360° and the measuring antenna was rotated about its vertical axis.




                                                                                                    Page 10 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                         Hermon Laboratories Ltd.
                                                                                         P.O.Box 23
                                                                                         Binyamina 30550, Israel
                                                                                         Tel.+972 46288001
                                                                                         Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                              e-mail: mail@hermonlabs.com




4.3           Conducted emissions test according to §15.207, 15.107

METHOD OF MEASUREMENTS                               ANSI 63.4 §13.1.3
DATE:                                                June 30, 2002
RELATIVE HUMIDITY:                                   44 %
AMBIENT TEMPERATURE:                                 24 °C
THE EUT WAS TESTED AS:                               TABLE-TOP
DETECTOR USED:                                       QUASI-PEAK
FREQUECNY RANGE:                                     450 kHz – 30 MHz
RESOLUTION BANDWIDTH:                                9 kHz


  Frequency,           Line             Measured       Specification     Margin,           Pass/          Reference to
                   identification       emissions,        limit,                            Fail            Plots in
        MHz                                  µV)
                                         dB (µ           dB (µµV)          dB                             Appendix A

   2.384565            Phase              29.35            48.00          18.65             Pass               A6
   8.032500            Neutral            28.53            48.00          19.47             Pass               A7
   19.114780           Phase              36.22            48.00          11.78             Pass               A6
   19.364275           Phase              40.82            48.00          7.18              Pass               A6
   19.613475           Phase              41.96            48.00          6.04              Pass               A6
   19.862045           Phase              39.42            48.00          8.58              Pass               A6
   20.110400           Phase              36.30            48.00          11.70             Pass               A6
   Measurement uncertainty, dB                                                      +2.43 / -2.22

LIMIT
                         Frequency,                                              Class B equipment,
                             MHz                                                          µV)
                                                                                       dB(µ
                         0.45 – 1.705                                                    48
                          1.705 - 30                                                     48


TEST PROCEDURE
The measurements were performed at mains terminals by means of LISN, connected to spectrum analyzer in the frequency
range as referred to in the table above. The unused coaxial connector of the LISN was terminated with 50 Ω. The
measurements were made with quasi-peak detector as referred to in the table.
The position of the EUT cables was varied to determine maximum emission level.


TEST EQUIPMENT USED:
    HL 0447           HL 0580            HL 0591          HL 0746        HL 1207           HL 1425           HL 1535




                                                                                                    Page 11 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                           Hermon Laboratories Ltd.
                                                                                           P.O.Box 23
                                                                                           Binyamina 30550, Israel
                                                                                           Tel.+972 46288001
                                                                                           Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                                e-mail: mail@hermonlabs.com




4.4          Unintentional radiated emissions test according to §15.109

METHOD OF MEASUREMENT:                           ANSI 63.4 §11.6 / ANSI 63.4 §12.1.4
TEST PERFORMED IN:                               ANECHOIC CHAMBER
DATE:                                            June 30, 2002
RELATIVE HUMIDITY:                               46 %
AMBIENT TEMPERATURE:                             26 °C
DISTANCE BETWEEN ANTENNA AND EUT:                3m
THE EUT WAS TESTED AS:                           TABLE-TOP
FREQUENCY RANGE:                                 30 MHz – 1 GHz
DETECTOR TYPE:                                   QUASI-PEAK
RESOLUTION BANDWIDTH:                            120 kHz
ANTENNA TYPE:                                    BICONILOG


   Frequency,        Ant.     Ant.     TT        Radiated          Limit          Margin,          Pass/        Reference
                     pol.     hgt.,   pos.,     emissions,                                          Fail         to Plots
       MHz                     m       (o)          µV/m)
                                                dB (µ               µV/m)
                                                                 dB(µ                dB                       in Appendix A

   76.189325           V      1.84     0          33.61            40.00            6.39           Pass            A4
   77.419325           V      1.11     0          30.91            40.00            9.09           Pass            A4
   78.652475           V      1.63     6          28.11            40.00           11.89           Pass            A4
  104.453900           H      3.02     0          37.49            43.50            6.01           Pass            A5
  120.527900           H      1.81     84         37.46            43.50            6.04           Pass            A5
  128.566000           H      2.00     98         40.82            43.50            2.68           Pass            A5
  144.632900           H      2.56    344         39.03            43.50            4.47           Pass            A5
  152.021250           V      1.00     77         36.15            43.50            7.35           Pass            A4


Table calculations and abbreviations:
Radiated emission dB(µV/m) = measured results dB(µV) + correction factor dB(1/m).
Correction factor    = antenna factor + cable loss (for antenna factor and cable loss refer to Appendix B).
Ant. pol.            = antenna polarization (V-vertical, H-horizontal).
Ant. hgt.            = antenna height.
                                                                          o
TT pos.              = turntable position in degrees, (EUT front panel = 0 ).
Margin               = dB below (negative if above) specification limit.



        The EUT highest used frequency (not including operating             Upper frequency of measurement range,
                           frequency), MHz                                                    MHz
      Below 1.705                                                                              30
      1.705 – 108                                                                            1000
      108 – 500                                                                              2000
      500 – 1000                                                                             5000
                                                                             th
      Above 1000                                                            5 harmonic of the highest frequency or 40
                                                                                     GHz, whichever is lower




                                                                                                   Page 12 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                   Hermon Laboratories Ltd.
                                                                                   P.O.Box 23
                                                                                   Binyamina 30550, Israel
                                                                                   Tel.+972 46288001
                                                                                   Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                        e-mail: mail@hermonlabs.com




LIMIT
                      Frequency,                             Class B equipment @ 3 m test distance
                         MHz                                                  µV/m)
                                                                           dB(µ
                        30 - 88                                               40
                        88 - 216                                             43.5
                       216 - 960                                              46
                      960 - 5000                                              54


TEST PROCEDURE
                                                                                                                   o
The EUT was placed on a wooden 80 cm height turntable. To find maximum radiation the turntable was rotated 360 ,
measuring antenna height was changed from 1 to 4 m, the antennas polarization was changed from vertical to horizontal
and the cables were moved.


TEST EQUIPMENT USED:
  HL 0465      HL 0521             HL 0589         HL 0592          HL 0593        HL 0594        HL 0604
   HL 1004           HL 2009




                                                                                             Page 13 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                    Hermon Laboratories Ltd.
                                                                                    P.O.Box 23
                                                                                    Binyamina 30550, Israel
                                                                                    Tel.+972 46288001
                                                                                    Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                         e-mail: mail@hermonlabs.com




Appendix A Plots

                                                      Plot A1
                              Field strength of fundamental test result, 125 kHz carrier




                                                                                            Page 14 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                      Hermon Laboratories Ltd.
                                                                                      P.O.Box 23
                                                                                      Binyamina 30550, Israel
                                                                                      Tel.+972 46288001
                                                                                      Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                           e-mail: mail@hermonlabs.com




                                                        Plot A2
                                        Field strength of emission test results


                              FREQUENCY RANGE:                          9 – 150 kHz




                                                                                              Page 15 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                   Hermon Laboratories Ltd.
                                                                                   P.O.Box 23
                                                                                   Binyamina 30550, Israel
                                                                                   Tel.+972 46288001
                                                                                   Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                        e-mail: mail@hermonlabs.com




                                                        Plot A3
                                        Field strength of emission test results


                              FREQUENCY RANGE:                          0.15 – 30 MHz




                                                                                           Page 16 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                   Hermon Laboratories Ltd.
                                                                                   P.O.Box 23
                                                                                   Binyamina 30550, Israel
                                                                                   Tel.+972 46288001
                                                                                   Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                        e-mail: mail@hermonlabs.com




                                                        Plot A4
                                        Field strength of emission test results

                              FREQUENCY RANGE:                          30 – 1000 MHz
                              POLARIZATION:                             VERTICAL




                                                                                           Page 17 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                   Hermon Laboratories Ltd.
                                                                                   P.O.Box 23
                                                                                   Binyamina 30550, Israel
                                                                                   Tel.+972 46288001
                                                                                   Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                        e-mail: mail@hermonlabs.com




                                                        Plot A5
                                        Field strength of emission test results

                              FREQUENCY RANGE:                          30 – 1000 MHz
                              POLARIZATION:                             HORIZONTAL




                                                                                           Page 18 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                     Hermon Laboratories Ltd.
                                                                     P.O.Box 23
                                                                     Binyamina 30550, Israel
                                                                     Tel.+972 46288001
                                                                     Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                          e-mail: mail@hermonlabs.com




                                             Plot A6
                                 Conducted emissions on power line

                              LINE:                    PHASE




                                                                             Page 19 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                     Hermon Laboratories Ltd.
                                                                     P.O.Box 23
                                                                     Binyamina 30550, Israel
                                                                     Tel.+972 46288001
                                                                     Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                          e-mail: mail@hermonlabs.com




                                             Plot A7
                                 Conducted emissions on power line

                              LINE:                    NEUTRAL




                                                                             Page 20 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                     Hermon Laboratories Ltd.
                                                                                     P.O.Box 23
                                                                                     Binyamina 30550, Israel
                                                                                     Tel.+972 46288001
                                                                                     Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                          e-mail: mail@hermonlabs.com




Appendix B Test equipment used for tests
   HL                   Description                           Manufacturer information                       Due
Serial No.                                                                                                  Calibr.
                                               Name                Model No.       Serial No.
                                                                                                          Month/Year
  0447        LISN, 16/2, 300 V RMS            Hermon Labs           LISN 16-1             0447              11/02

  0465        Anechoic chamber                 Hermon Labs             AC-1                023               2/03
              9 (L) x 6.5 (W) x 5.5 (H) m
  0521        Spectrum analyzer with RF        Hewlett Packard         8546A               0319              9/02
              filter section (EMI receiver
              9 kHz - 6.5 GHz)
  0580        DC block adaptor                 Anritsu               MA8601 A              580               12/02
              10 kHz-2.2 GHz
  0589        Cable coaxial, GORE              Hermon Labs            GORE-3               589               11/02
              A2POL118.2, 3m
  0591        Attenuator 10 dB, 50 Ohm,        Elisra Electronic    MW2100-N-               3                1/03
              N-type, 2W                       Systems                 Type
  0592        Position controller              Hermon Labs          L2-SR3000              100            5/03 Check

  0593        Antenna mast, 1-4 m/             Hermon Labs             AM-F1               101            2/03 Check
              1-6 m Pneumatic
  0594        Turntable for anechoic           Hermon Labs             WDC1                102            1/03 Check
              chamber, flush mounted,
              d=1.2 m, pneumatic
  0604        Antenna biconilog log-           EMCO                    3141              9611-1011           1/03
              periodic/T Bow-Tie,
              26 - 2000 MHz
  0746        Transformer isolation, 230 V,    Hermon Labs               75                 NA            5/03 Check
              1 kVA
  0813        Cable, coax, RG-214, 12 m,       Hermon Labs            C214-12              149               12/02
              N-type connectors
  1004        Cable, coaxial ANDREW            Hermon Labs           ANDREW-6              163               12/02
              PSWJ4, 6 m
  1207        One phase voltage regulator, 2   Hermon Labs            TDGC-2                NA            6/03 Check
              kVA, 0-250V
  1425        EMI receiver, 9 kHz – 2.9 GHz    Agilent                 8542E         3710A00222,             9/02
                                               Technologies                          3705A00204
  1430        EMI receiver, 9 kHz – 2.9 GHz    Agilent                 8542E         3807A00262,             9/02
                                               Technologies                          3705A00217
  1535        Cable RF, 12 m                   Alpha Wire            RG-214/U            NA                  12/02

  1552        Cable RF, 8 m                    Alpha Wire            RG-214-8m             1552              12/02

  1915        Active receiving loop antenna,   EMC Test                6507                1457              6/03
              1 kHz – 30 MHz                   Systems
  2009        Cable RF, 8 m                    Alpha Wire             RG-214               C-56              12/02




                                                                                                  Page 21 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                         Hermon Laboratories Ltd.
                                                                                         P.O.Box 23
                                                                                         Binyamina 30550, Israel
                                                                                         Tel.+972 46288001
                                                                                         Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                              e-mail: mail@hermonlabs.com




Appendix C General information
Test facility description
Tests were performed at Hermon Laboratories Ltd., which is a fully independent, private EMC, Safety and
Telecommunication testing facility. Hermon Laboratories is listed by the Federal Communications Commission (USA) for all
parts of Code of Federal Regulations 47 (CFR 47) and by Industry Canada for electromagnetic emissions (file numbers IC
2186-1 for OATS and IC 2186-2 for anechoic chamber), certified by VCCI, Japan (the registration numbers are R-808 for
OATS, R-1082 for anechoic chamber, C-845 for conducted emissions site), assessed by TNO Certification EP&S
(Netherlands) for a number of EMC, Telecommunications, Safety standards, and by AMTAC (UK) for safety of Medical
Devices. The laboratory is accredited by American Association for Laboratory Accreditation (USA) according to ISO/IEC
17025 for Electromagnetic Compatibility, Product Safety, Telecommunications Testing and Environmental Simulation (for
exact scope please refer to Certificate No. 839.01).
Address:          PO Box 23, Binyamina 30550, Israel.
Telephone:        +972 4628 8001
Fax:              +972 4628 8277
e-mail            mail@hermonlabs.com

Person for contact: Mr. Alex Usoskin, QA manager.

Abbreviations and acronyms
   The following abbreviations and acronyms are applicable to this test report:
             cm               centimeter
             dB               decibel
             dBm              decibel referred to one milliwatt
             dB(µV)           decibel referred to one microvolt
             dB(µV/m)         decibel referred to one microvolt per meter
             EMC              electromagnetic compatibility
             EUT              equipment under test
             GHz              gigahertz
             H                height
             Hz               hertz
             kHz              kilohertz
             kV               kilovolt
             L                length
             LISN             line impedance stabilization network
             m                meter
             MHz              megahertz
             NA               not applicable
             QP               quasi-peak
             RF               radio frequency
             RE               radiated emission
             rms              root mean square
             s                second
             V                volt
             W                width


Specification references

 47CFR part 15: 2001                   Radio Frequency Devices
 ANSI C63.2: 1996                      American National Standard for Instrumentation-Electromagnetic Noise and
                                       Field Strength, 10 kHz to 40 GHz-Specifications.
 ANSI C63.4: 1992                      American National Standard for Methods of Measurement of Radio-Noise
                                       Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of
                                       9 kHz to 40 GHz.




                                                                                                 Page 22 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                          Hermon Laboratories Ltd.
                                                                                          P.O.Box 23
                                                                                          Binyamina 30550, Israel
                                                                                          Tel.+972 46288001
                                                                                          Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                               e-mail: mail@hermonlabs.com




Appendix D Test equipment correction factors
                                                      Antenna factor
                                                    Active loop antenna
                                                        Model 6507
                                                         S/N 1457


                              Frequency,           Magnetic Antenna Factor,        Electric Antenna Factor,
                                 MHz                       dB(S/m)                            dB
                                 0.001                        -0.8                           50.7
                                 0.002                        -6.1                           45.4
                                 0.003                       -10.0                           41.5
                                 0.005                       -15.3                           36.2
                                 0.007                       -18.5                           33.0
                                 0.009                       -20.8                           30.7
                                 0.010                       -21.9                           29.7
                                 0.020                       -27.1                           24.5
                                 0.050                       -31.0                           20.5
                                 0.075                       -31.7                           19.8
                                 0.100                       -31.9                           19.6
                                 0.150                       -32.1                           19.4
                                 0.250                       -32.3                           19.2
                                 0.500                       -32.6                           18.9
                                 0.750                       -32.7                           18.8
                                 1.000                       -32.8                           18.7
                                 2.000                       -33.2                           18.3
                                 3.000                       -33.5                           18.0
                                 4.000                       -33.9                           17.6
                                 5.000                       -34.1                           17.4
                                10.000                       -34.8                           16.7
                                15.000                       -35.3                           16.3
                                20.000                       -35.3                           16.3
                                25.000                       -35.8                           15.7
                                30.000                       -35.9                           15.7

Antenna factor is to be added to receiver meter reading in dB(µV) to convert to field intensity in dB(µV)/meter




                                                                                                   Page 23 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                                      Hermon Laboratories Ltd.
                                                                                                      P.O.Box 23
                                                                                                      Binyamina 30550, Israel
                                                                                                      Tel.+972 46288001
                                                                                                      Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                                           e-mail: mail@hermonlabs.com




                                                           Antenna Factor
                                                Biconilog Antenna EMCO Model 3141
                                                            Ser.No.1011
       Frequency, MHz               Antenna Factor,                 Frequency, MHz               Antenna Factor,
                                        dB(1/m)                                                      dB(1/m)
               26                         7.8                              940                        24.0
               28                         7.8                              960                        24.1
               30                         7.8                              980                        24.5
               40                         7.2                              1000                       24.9
               60                         7.1                              1020                       25.0
               70                         8.5                              1040                       25.2
               80                         9.4                              1060                       25.4
               90                         9.8                              1080                       25.6
              100                         9.7                              1100                       25.7
              110                         9.3                              1120                       26.0
              120                         8.8                              1140                       26.4
              130                         8.7                              1160                       27.0
              140                         9.2                              1180                       27.0
              150                         9.8                              1200                       26.7
              160                        10.2                              1220                       26.5
              170                        10.4                              1240                       26.5
              180                        10.4                              1260                       26.5
              190                        10.3                              1280                       26.6
              200                        10.6                              1300                       27.0
              220                        11.6                              1320                       27.8
              240                        12.4                              1340                       28.3
              260                        12.8                              1360                       28.2
              280                        13.7                              1380                       27.9
              300                        14.7                              1400                       27.9
              320                        15.2                              1420                       27.9
              340                        15.4                              1440                       27.8
              360                        16.1                              1460                       27.8
              380                        16.4                              1480                       28.0
              400                        16.6                              1500                       28.5
              420                        16.7                              1520                       28.9
              440                        17.0                              1540                       29.6
              460                        17.7                              1560                       29.8
              480                        18.1                              1580                       29.6
              500                        18.5                              1600                       29.5
              520                        19.1                              1620                       29.3
              540                        19.5                              1640                       29.2
              560                        19.8                              1660                       29.4
              580                        20.6                              1680                       29.6
              600                        21.3                              1700                       29.8
              620                        21.5                              1720                       30.3
              640                        21.2                              1740                       30.8
              660                        21.4                              1760                       31.1
              680                        21.9                              1780                       31.0
              700                        22.2                              1800                       30.9
              720                        22.2                              1820                       30.7
              740                        22.1                              1840                       30.6
              760                        22.3                              1860                       30.6
              780                        22.6                              1880                       30.6
              800                        22.7                              1900                       30.6
              820                        22.9                              1920                       30.7
              840                        23.1                              1940                       30.9
              860                        23.4                              1960                       31.2
              880                        23.8                              1980                       31.6
              900                        24.1                              2000                       32.0
              920                        24.1
Antenna factor is to be added to receiver meter reading in dB(µV) to convert to field intensity in dB(µV/meter).




                                                                                                                   Page 24 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                    Hermon Laboratories Ltd.
                                                                                    P.O.Box 23
                                                                                    Binyamina 30550, Israel
                                                                                    Tel.+972 46288001
                                                                                    Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                         e-mail: mail@hermonlabs.com




                                                       Cable loss
                              Cable Coaxial, GORE A2P01POL118, 2.3 m, model:GORE-3, HL 0589
                              + Cable Coaxial, ANDREW PSWJ4, 6m, model: ANDREW-6, HL 1004


                                                                   Tolerance               Measurement
            Frequency,                  Cable loss,
 No.                                                             (Specification),           uncertainty,
               MHz                         dB
                                                                       dB                       dB
 1                30                       0.33
 2                50                       0.40
 3               100                       0.57
 4               300                       0.97
 5               500                       1.25
 6               800                       1.59
 7              1000                       1.81
 8              1200                       1.97                       ≤ 6.5                     ±0.12
 9              1400                       2.15
 10             1600                       2.28
 11             1800                       2.43
 12             2000                       2.61
 13             2200                       2.75
 14             2400                       2.89
 15             2600                       2.97
 16             2800                       3.21                       ≤ 6.5                     ±0.12
 17             3000                       3.32
 18             3300                       3.47
 19             3600                       3.62
 20             3900                       3.84
 21             4200                       3.92                                                 ±0.17
 22             4500                       4.07
 23             4800                       4.36
 24             5100                       4.62
 25             5400                       4.78
 26             5700                       5.16
 27             6000                       5.67
 28             6500                       5.99




                                                                                            Page 25 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                            Hermon Laboratories Ltd.
                                                                            P.O.Box 23
                                                                            Binyamina 30550, Israel
                                                                            Tel.+972 46288001
                                                                            Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                 e-mail: mail@hermonlabs.com




                                                Cable loss
                                   RF cable 8 m, model RG-214, HL 2009




                  Frequency,   Cable loss,   Tolerance (Specification),   Measurement uncertainty,
    No.
                     MHz          dB                    dB                         dB

     1                  1         0.10

     2                 10         0.14

     3                 30         0.25

     4                 50         0.34

     5                 100        0.53

     6                 300        0.99

     7                 500        1.31

     8                 800        1.73

     9                1000        1.98

     10               1100        2.11                  NA                          ±0.12

     11               1200        2.21

     12               1300        2.35

     13               1400        2.46

     14               1500        2.55

     15               1600        2.68

     16               1700        2.78

     17               1800        2.88

     18               1900        2.98

     19               2000        3.09




                                                                                    Page 26 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                             Hermon Laboratories Ltd.
                                                             P.O.Box 23
                                                             Binyamina 30550, Israel
                                                             Tel.+972 46288001
                                                             Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                  e-mail: mail@hermonlabs.com




                                           Cable loss
                                     Cable RG-214, HL 0813




                                                                     Page 27 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                       Hermon Laboratories Ltd.
                                                                       P.O.Box 23
                                                                       Binyamina 30550, Israel
                                                                       Tel.+972 46288001
                                                                       Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                            e-mail: mail@hermonlabs.com




                                             Cable loss
                              RF cable 8 m, model RG-214-8m, HL 1552

No.          Frequency,         Cable loss,         Measurement uncertainty,     Notes
                MHz                 dB                       dB
1               0.010              0.01
2                 0.1                0.01
3                  1                 0.03
4                 10                 0.12
5                 20                 0.23
6                 30                 0.30
7                 40                 0.32
8                 50                 0.34
9                 60                 0.39
10                70                 0.43
11                80                 0.48
12                90                 0.50
13                100                0.55
14                200                0.78                     ±0.05
15                300                1.04
16                400                1.16
17                500                1.33
18                600                1.51
19                700                1.65
20                800                1.77
21                900                1.92
22               1000                2.04
23               1200                2.26
24               1400                2.49
25               1600                2.74
26               1800                2.94
27               2000                3.18
28               2500                3.65
29               2900                4.08




                                                                               Page 28 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002


                                                                                          Hermon Laboratories Ltd.
                                                                                          P.O.Box 23
                                                                                          Binyamina 30550, Israel
                                                                                          Tel.+972 46288001
                                                                                          Fax.+972 46288277
HE R MON L AB OR AT OR IE S                                                               e-mail: mail@hermonlabs.com




                                                   Correction factor
                                          Line impedance stabilization network
                                                   Model LISN 16 - 1
                                                 Hermon Laboratories

                                      Frequency, kHz                  Correction Factor
                                            10                               4.9
                                            15                              2.86
                                            20                              1.83
                                            25                              1.25
                                            30                              0.91
                                            35                              0.69
                                            40                              0.53
                                            50                              0.35
                                            60                              0.25
                                            70                              0.18
                                            80                              0.14
                                            90                              0.11
                                           100                              0.09
                                           125                              0.06
                                           150                              0.04

The correction factor dB is to be added to the meter readings (dB/µV) of the interference analyzer or spectrum analyzer.




                                                                                                  Page 29 of 29
Document ID: ROKRAD_FCC.15061K.doc
Date of Issue: July 2002



Document Created: 2002-10-28 11:33:16
Document Modified: 2002-10-28 11:33:16

© 2024 FCC.report