Test Report

FCC ID: IYZSK1

Test Report

Download: PDF
FCCID_4429691

Report on the FCC and IC Testing of the
Marquardt GmbH

Model: SK1

In accordance with FCC 47 CFR Part 15C and
ISED Canada RSS-210 and ISED Canada RSS-
GEN
Prepared for:                 Marquardt GmbH
                              Schloßstrasse 16
                              78604 Rietheim-Weilheim
                              Germany

FCC ID: IYZSK1
IC: 2701A-SK1

COMMERCIAL-IN-CONFIDENCE
Date: 2019-09-02
Document Number: TR-64038-67571-02 | Issue: 01
RESPONSIBLE FOR                     NAME                                                                   DATE                               SIGNATURE

Project Management                  Michael Ingerl                                                         2019-09-02


Authorised Signatory                Markus Biberger                                                        2019-09-02

Signatures in this approval box have checked this document in line with the requirements of TÜV SÜD Product Service document control rules.

ENGINEERING STATEMENT
The measurements shown in this report were made in accordance with the procedures described on test pages. All reported testing
was carried out on a sample equipment to demonstrate limited compliance with FCC 47 CFR Part 15C and ISED Canada RSS-210
and ISED Canada RSS-GEN. The sample tested was found to comply with the requirements defined in the applied rules.
RESPONSIBLE FOR                     NAME                                                                   DATE                               SIGNATURE

Testing                             Michael Ingerl                                                         2019-09-02

Laboratory Accreditation                   Laboratory recognition                    ISED Canada test site registration
DAkkS Reg. No. D-PL-11321-11-02            Registration No. BNetzA-CAB-16/21-15      3050A-2
EXECUTIVE SUMMARY
A sample of this product was tested and found to be compliant with FCC 47 CFR Part 15C, ISED Canada RSS-210 and ISED
Canada RSS-GEN:2016, Issue 09 (08-2016) and Issue 04 (11-2014).


                                        DISCLAIMER AND COPYRIGHT
                                        This non-binding report has been prepared by TÜV SÜD Product Service with all reasonable skill and care. The document is confidential to the
                                        potential Client and TÜV SÜD Product Service. No part of this document may be reproduced without the prior written approval of TÜV SÜD
                                        Product Service. © 2019 TÜV SÜD Product Service.
                                        ACCREDITATION
                                        Our BNetzA Accreditation does not cover opinions and interpretations and any expressed are outside the scope of our BNetzA Accreditation.
                                        Results of tests not covered by our BNetzA Accreditation Schedule are marked NBA (Not BNetzA Accredited).

 Trade Register Munich                          Managing Directors:                         Phone: +49 (0) 9421 55 22-0                   TÜV SÜD Product Service GmbH
 HRB 85742                                      Dr. Peter Havel (CEO)                       Fax: +49 (0) 9421 55 22-99
 VAT ID No. DE129484267                         Dr. Jens Butenandt                          www.tuev-sued.de                              Äußere Frühlingstraße 45
 Information pursuant to Section 2(1)                                                                                                     94315 Straubing
 DL-InfoV (Germany) at                                                                                                                    Germany
 www.tuev-sued.com/imprint



    TÜV SÜD Product Service


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




Contents
1           Report Summary .........................................................................................................................2
1.1         Report Modification Record ...........................................................................................................2
1.2         Introduction ....................................................................................................................................2
1.3         Brief Summary of Results .............................................................................................................3
1.4         Product Information .......................................................................................................................4
1.5         Deviations from the Standard ........................................................................................................4
1.6         EUT Modification Record ..............................................................................................................5
1.7         Test Location .................................................................................................................................5
2           Test Details ..................................................................................................................................6
2.1         Field Strength of any Emission .....................................................................................................6
2.2         20 dB Bandwidth ........................................................................................................................ 18
2.3         Switch off time ............................................................................................................................ 21
2.4         Restricted Band Edges............................................................................................................... 23
2.5         Exposure of Humans to RF Fields and SAR exclusion threshold .............................................. 25
3           Measurement Uncertainty ....................................................................................................... 30




      COMMERCIAL-IN-CONFIDENCE                                                                                                                Page 1 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




1          Report Summary

1.1        Report Modification Record

           Alterations and additions to this report will be issued to the holders of each copy in the form of a
           complete document.

            Issue           Description of Change                                               Date of Issue

            1               First Issue                                                         2019-09-02


                                                             Table 1

1.2        Introduction

           Applicant                                Marquardt GmbH
           Manufacturer                             Marquardt Switches (Shanghai) Co., Ltd.
           Model Number(s)                          SK1
           Serial Number(s)                         ---
           Software Version                         ---
           Number of Samples Tested                 1
           Test Specification/Issue/Date            FCC 47 CFR Part 15C, ISED Canada RSS-210 and ISED
                                                    Canada RSS-GEN:2016, Issue 09 (08-2016) and Issue 04
                                                    (11-2014), FCC rule Part 2.1093, KDB 447498 D01, RSS-
                                                    102 Issue 5
           Test Plan/Issue/Date                     ---
           Order Number                             6200359433
           Date of Receipt of EUT                   2019-08-05
           Start of Test                            2019-08-21
           Finish of Test                           2019-08-28
           Name of Engineer(s)                      Michael Ingerl
           Related Document(s)                      ANSI C63.10 (2013)
                                                    ANSI C63.4: 2014




      COMMERCIAL-IN-CONFIDENCE                                                                       Page 2 of 32


                           Document Number: TR-64038-67571-02 | Issue: 01
                           COMMERCIAL-IN-CONFIDENCE




1.3   Brief Summary                                                                                                                          of Results

      A brief summary of the tests carried out in accordance with FCC 47 CFR Part 15C and ISED Canada RSS-210, ISED Canada RSS-GEN, FCC rule Part
      2.1093, KDB 447498 D01 is shown below.

       Section      Specification Clause     Test Description                                              Result   Comments/Base Standard
       Configuration and Mode: Battery Powered 3 V – Transmitting continuously
       2.1          15.209, 4.3 and 6.13     Field Strength of any Emission                                Pass     ANSI C63.10 (2013)
       2.2          15.215 (c), N/A and      20 dB Bandwidth                                               Pass     ANSI C63.10 (2013)
                    6.6
       2.3          15.231 (a)               Switch off time                                               Pass     ANSI C63.10 (2013)
       2.4          15.205, 4.1 and 8.10     Restricted Band Edges                                         Pass     ANSI C63.10 (2013)
       2.5          15.107 and 6.1           Exposure of Humans to RF Fields and SAR exclusion threshold   Pass     ANSI C63.4: 2014


                                                                                           Table 2




                                 COMMERCIAL-IN-CONFIDENCE                                                                  Page 3 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




1.4        Product Information

1.4.1      Technical Description



Equipment characteristics

Type designation:                        SK1
Type of equipment:                       Passive entry car key
Operating Frequency:                     433.92 MHz
Number of RF channels:                   1
Modulation:                              2-FSK
Modulation Content:                      Digital data
Data Rate:                               5 kBit/s; 20 kBit/s
Antenna:                                 PCB loop antenna

Standby mode:                            Not Applicable
Power supply:                            Battery supply
                                         Nominal:                3V
                                         Nominal frequency:      DC




1.5        Deviations from the Standard

           none




      COMMERCIAL-IN-CONFIDENCE                                        Page 4 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




1.6        EUT Modification Record

           The table below details modifications made to the EUT during the test programme.
           The modifications incorporated during each test are recorded on the appropriate test pages.

                                                                                                                Date Modification
            Modification State   Description of Modification still fitted to EUT       Modification Fitted By
                                                                                                                Fitted
            0                    As supplied by the customer                           Not Applicable           Not Applicable


                                                                     Table 3

1.7        Test Location

           TÜV SÜD Product Service conducted the following tests at our Straubing Test Laboratory.

            Test Name                                                 Name of Engineer(s)
            Configuration and Mode: Battery Powered 3 V – Transmitting continuously
            Field Strength of any Emission                            Michael Ingerl
            20 dB Bandwidth                                           Michael Ingerl
            Switch off time                                           Michael Ingerl
            Restricted Band Edges                                     Michael Ingerl
            Exposure of Humans to RF Fields and SAR                   Michael Ingerl
            exclusion threshold


                                                                     Table 4

           Office Address:

           Äußere Frühlingstraße 45
           94315 Straubing
           Germany




      COMMERCIAL-IN-CONFIDENCE                                                                                       Page 5 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2          Test Details

2.1        Field Strength of any Emission

2.1.1      Specification Reference

           FCC 47 CFR Part 15C, ISED Canada RSS-210 and ISED Canada RSS-GEN, Clause 15.209, 4.3
           and 6.13

2.1.2      Equipment Under Test and Modification State

           SK1, S/N: --- - Modification State 0

2.1.3      Date of Test

           2019-08-21

2.1.4      Test Method

           This test was performed in accordance with ANSI C63.10, clause 6.3, 6.4 and 6.5. and ISED
           Canada RSS-Gen clause 6.13.
           Measurements were made at a distance of 3 m. The limit lines shown on the plot were extrapolated
           from either 300 m or 30 m to the measurement distance of 3 m in accordance with ANSI C63.10
           Clause 6.4.4.2.
           For any emissions detected within 20 dB of the limit, a final measurement was made and recorded
           in the table below. The detector used for these measurements was a quasi-peak detector except
           for emissions within the bands 9 kHz to 90 kHz and 110 kHz to 490 kHz where a CISPR average
           detector was used.


2.1.5      Environmental Conditions

           Ambient Temperature        21.0 °C
           Relative Humidity          31.0 %




      COMMERCIAL-IN-CONFIDENCE                                                                Page 6 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.1.6     Test Results

          Battery Powered 3 V – Transmitting continuously


          1. Orthogonal axis



                                       130

                                       120

                                       110

                                       100

                                       90

                                       80

                                       70
                    Level in dB µV/m




                                       60

                                       50

                                       40

                                       30

                                       20

                                        10

                                        0

                                       -10



                                         9k         20    30       50   100 k     200 300     500         1M   2M   3M   5M   10M   20 30M




                                        P re view R esult 1-QP K                FC C 15.20 9 mag (10 m)
                                        Fin al_Res ult QP K                     Fin al_Res ult CA V




   COMMERCIAL-IN-CONFIDENCE                                                                                                          Page 7 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                       80

                                       75

                                       70

                                       65

                                       60

                                       55

                                       50

                                       45
                    Level in dB µV/m




                                       40

                                       35

                                       30

                                       25

                                       20

                                       15

                                       10

                                       5

                                       0
                                       30M                50   60      80   100 M                 200       300      400    500           800      1G




                                        P re view R esult 1H-P K+             P re view R esult 1V-P K+            FC C 15.20 9                 Fin al_Res ult P K +




                                                                               Final Results 1:

     Frequency     MaxPeak                        Limit        Margin       Meas.         Bandwidth       Pol     Azimuth         Corr.    Comment
                                                                            Time
       MHz         dBµV/m                       dBµV/m              dB       ms               kHz                  deg            dB/m
    433.908000       76.83                        80.80             3.97        2.5          100.000       V        91.0            -16   Fundamental
    867.886000       38.75                        46.00             7.25        2.5          100.000       V       115.0            -10       ---




   COMMERCIAL-IN-CONFIDENCE                                                                                                                 Page 8 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                       80

                                       75

                                       70

                                       65

                                       60

                                       55

                                       50
                    Level in dB µV/m




                                       45

                                       40

                                       35

                                       30

                                       25

                                       20

                                       15

                                       10

                                       5

                                       0
                                        1G                                   2G                   3G                 4G              5G




                                        P re view R esult 2 V-A V G   P re view R esult 1V-P K+        P re view R esult 2 H-A V G
                                        P re view R esult 1H-P K+     FC C 15.20 9 P K                 FC C 15.20 9 A V
                                        Fin al_Res ult P K +          Fin al_Res ult A V G




   COMMERCIAL-IN-CONFIDENCE                                                                                                     Page 9 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




          2. Orthogonal axis




                                  130

                                  120

                                  110

                                  100

                                  90

                                  80

                                  70
               Level in dB µV/m




                                  60

                                  50

                                  40

                                  30

                                  20

                                   10

                                   0

                                  -10



                                    9k         20    30       50   100 k     200 300     500         1M   2M   3M   5M   10M   20 30M




                                   P re view R esult 1-QP K                FC C 15.20 9 mag (10 m)
                                   Fin al_Res ult QP K                     Fin al_Res ult CA V




   COMMERCIAL-IN-CONFIDENCE                                                                                                        Page 10 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                  80

                                  75

                                  70

                                  65

                                  60

                                  55

                                  50

                                  45
               Level in dB µV/m




                                  40

                                  35

                                  30

                                  25

                                  20

                                  15

                                  10

                                  5

                                  0
                                  30M               50     60    80    100 M                 200       300      400    500           800      1G




                                   P re view R esult 1H-P K+             P re view R esult 1V-P K+            FC C 15.20 9                 Fin al_Res ult P K +




                                                                          Final Results 1:

       Frequency                       MaxPeak           Limit   Margin        Meas.      Bandwidth     Pol     Azimuth      Corr.          Comment
                                                                               Time
         MHz                           dBµV/m        dBµV/m           dB        ms            kHz                  deg       dB/m
      433.908000                         75.60         80.80          5.20       2.5         100.000     H         120.0       -16     Fundamental
      867.886000                         38.50         46.00          7.50       2.5         100.000     H         110.0       -10         ---




   COMMERCIAL-IN-CONFIDENCE                                                                                                                    Page 11 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                  80

                                  75

                                  70

                                  65

                                  60

                                  55

                                  50
               Level in dB µV/m




                                  45

                                  40

                                  35

                                  30

                                  25

                                  20

                                  15

                                  10

                                  5

                                  0
                                   1G                                   2G                   3G                 4G              5G




                                   P re view R esult 2 V-A V G   P re view R esult 1V-P K+        P re view R esult 2 H-A V G
                                   P re view R esult 1H-P K+     FC C 15.20 9 P K                 FC C 15.20 9 A V
                                   Fin al_Res ult P K +          Fin al_Res ult A V G




   COMMERCIAL-IN-CONFIDENCE                                                                                                     Page 12 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




          3. Orthogonal axis




                                  130

                                  120

                                  110

                                  100

                                  90

                                  80

                                  70
               Level in dB µV/m




                                  60

                                  50

                                  40

                                  30

                                  20

                                   10

                                   0

                                  -10



                                    9k         20    30       50   100 k     200 300     500         1M   2M   3M   5M   10M   20 30M




                                   P re view R esult 1-QP K                FC C 15.20 9 mag (10 m)
                                   Fin al_Res ult QP K                     Fin al_Res ult CA V




   COMMERCIAL-IN-CONFIDENCE                                                                                                        Page 13 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                  80

                                  75

                                  70

                                  65

                                  60

                                  55

                                  50

                                  45
               Level in dB µV/m




                                  40

                                  35

                                  30

                                  25

                                  20

                                  15

                                  10

                                  5

                                  0
                                  30M               50     60    80   100 M                 200       300      400    500           800      1G




                                   P re view R esult 1H-P K+            P re view R esult 1V-P K+            FC C 15.20 9                 Fin al_Res ult P K +




                                                                              Final Results 1:

       Frequency                       MaxPeak           Limit   Margin        Meas.     Bandwidth     Pol     Azimuth      Corr.          Comment
                                                                               Time
         MHz                           dBµV/m        dBµV/m        dB           ms           kHz                  deg       dB/m
      433.908000                         75.64         80.80       5.16          2.5        100.000     V         289.0       -16     Fundamental
      867.886000                         35.61         46.00      10.39          2.5        100.000     V         279.0       -10         ---




   COMMERCIAL-IN-CONFIDENCE                                                                                                                   Page 14 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                  80

                                  75

                                  70

                                  65

                                  60

                                  55

                                  50
               Level in dB µV/m




                                  45

                                  40

                                  35

                                  30

                                  25

                                  20

                                  15

                                  10

                                  5

                                  0
                                   1G                                   2G                   3G                 4G              5G




                                   P re view R esult 2 V-A V G   P re view R esult 1V-P K+        P re view R esult 2 H-A V G
                                   P re view R esult 1H-P K+     FC C 15.20 9 P K                 FC C 15.20 9 A V
                                   Fin al_Res ult P K +          Fin al_Res ult A V G




   COMMERCIAL-IN-CONFIDENCE                                                                                                     Page 15 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




          FCC 47 CFR Part 15, Limit Clause 15.209

           Frequency (MHz)                       Field Strength (µV/m)                  Measurement Distance (m)
           0.009 to 0.490                        2400/F (kHz)                           300
           0.490 to 1.705                        24000/F (kHz)                          30
           1.705 to 30                           30                                     30
           30 to 88                              100**                                  3
           88 to 216                             150**                                  3
           216 to 960                            200**                                  3
           Above 960                             500                                    3


                                                         Table 5 - FCC Limit

          NOTE: The level of any unwanted emissions from an intentional radiator operating under these
          general provisions shall not exceed the level of the fundamental emission.

          ISED Canada RSS-210, Limit Clause 4.4

          Under no circumstance shall the level of any unwanted emissions exceed the level of the
          fundamental emissions.

          ISED Canada RSS-Gen, Limit Clause 8.9

           Frequency (MHz)                       Field Strength (µV/m)                  Measurement Distance (m)
           0.009 to 0.490                        2400/F (kHz)                           300
           0.490 to 1.705                        24000/F (kHz)                          30
           1705 to 30                            30                                     30


                                             Table 6 - IC Limit, Below 30 MHz

           Frequency (MHz)                                           Field Strength (µV/m at 3 metres)
           30 to 88                                                  100
           88 to 216                                                 150
           216 to 960                                                200
           Above 960                                                 500


                                             Table 7 - IC Limit, Above 30 MHz




   COMMERCIAL-IN-CONFIDENCE                                                                                Page 16 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.1.7     Test Location and Test Equipment Used

          This test was carried out in Semi anechoic room - cabin no. 8.

                                                                                   Calibration
           Instrument                Manufacturer        Type No           TE No   Period        Calibration Due
                                                                                   (months)

           Loop Antenna              Rohde & Schwarz     HFH2-Z2           18876   36            2022-08-31

           TRILOG Antenna (4db)      Schwarzbeck         VULB 9162         20116   36            2022-01-31

           Horn antenna              Rohde & Schwarz     HF907             19933   24            2021-07-31

           EMI test receiver         Rohde & Schwarz     ESW26             28268   12            2020-06-30

           EMC measurement
                                     Rohde & Schwarz     EMC32-ME+         19719   N/A           N/A
           software


                                                       Table 8

          TU - Traceability Unscheduled
          O/P Mon – Output Monitored using calibrated equipment
          N/A - Not Applicable




   COMMERCIAL-IN-CONFIDENCE                                                                      Page 17 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.2        20 dB Bandwidth

2.2.1      Specification Reference

           FCC 47 CFR Part 15C, ISED Canada RSS-210 and ISED Canada RSS-GEN, Clause 15.215 (c),
           N/A and 6.6

2.2.2      Equipment Under Test and Modification State

           SK1, S/N: --- - Modification State 0

2.2.3      Date of Test

           2019-08-28

2.2.4      Test Method

           The test was performed in accordance with ANSI C63.10, clause 6.9.1.



2.2.5      Environmental Conditions

           Ambient Temperature        20.0 °C
           Relative Humidity          31.0 %

2.2.6      Test Results

           Battery Powered 3 V – Transmitting continuously

            Frequency (MHz)      20 dB Bandwidth   99% Occupied      FLOWER (MHz)   FUPPER (MHz)
                                 (kHz)             Bandwidth (kHz)
            433.92               159.45            161.76            433.84         434.00


                                                        Table 9




      COMMERCIAL-IN-CONFIDENCE                                                          Page 18 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                                    20 dB Bandwidth




                                                 99% Occupied Bandwidth




   COMMERCIAL-IN-CONFIDENCE                                               Page 19 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




          FCC 47 CFR Part 15, Limit Clause 15.215 (c) and ISED Canada RSS 210 and ISED Canada RSS
          GEN, Limit Clause


          The OBW shall not be wider than 0.25 % of the center frequency, here maximum 1.0848 MHz.




2.2.7     Test Location and Test Equipment Used

          This test was carried out in a non-shielded room.

                                                                               Calibration
           Instrument                Manufacturer        Type No       TE No   Period        Calibration Due
                                                                               (months)

           Spectrum Analyzer         Rohde & Schwarz     FSV40         20219   12            2020-01-31

           Climatic test chamber     ESPEC               PL-2J         18843   24            2020-03-31


                                                       Table 10

          TU - Traceability Unscheduled
          O/P Mon – Output Monitored using calibrated equipment
          N/A - Not Applicable




   COMMERCIAL-IN-CONFIDENCE                                                                  Page 20 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.3        Switch off time

2.3.1      Specification Reference

           FCC 47 CFR Part 15C, ISED Canada RSS-210 and ISED Canada RSS-GEN, Clause 15.231 (a)

2.3.2      Equipment Under Test and Modification State

           SK1, S/N: --- - Modification State 0

2.3.3      Date of Test

           2019-08-28

2.3.4      Test Method

           ---

2.3.5      Environmental Conditions

           Ambient Temperature        20.0 °C
           Relative Humidity          31.0 %


2.3.6      Test Results

           Battery Powered 3 V – Transmitting continuously




                                      Switch off time   Limit
                                      765 ms            5s




      COMMERCIAL-IN-CONFIDENCE                                                     Page 21 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




          FCC 47 CFR Part 15, Limit Clause 15.231 and ISED Canada RSS-GEN

          A manually operated transmitter shall employ a switch that will automatically deactivate the
          transmitter within not more than 5 seconds of being released.




2.3.7     Test Location and Test Equipment Used

          This test was carried out in a non-shielded room.

                                                                                     Calibration
           Instrument                Manufacturer         Type No            TE No   Period        Calibration Due
                                                                                     (months)

           Spectrum Analyzer         Rohde & Schwarz      FSV40              20219   12            2020-01-31


                                                       Table 11

          TU - Traceability Unscheduled
          O/P Mon – Output Monitored using calibrated equipment
          N/A - Not Applicable




   COMMERCIAL-IN-CONFIDENCE                                                                        Page 22 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.4        Restricted Band Edges

2.4.1      Specification Reference

           FCC 47 CFR Part 15C, ISED Canada RSS-210 and ISED Canada RSS-GEN, Clause 15.205, 4.1
           and 8.10

2.4.2      Equipment Under Test and Modification State

           SK1, S/N: --- - Modification State 0

2.4.3      Date of Test

           2019-08-21

2.4.4      Test Method

           This test was performed in accordance with ANSI C63.10, clause 11.13.1.

           Plots for average measurements were taken in accordance with ANSI C63.10 clause 4.1.4.2.3.

           Final average measurements were taken in accordance with ANSI C63.10 clause 4.1.4.2.2.



2.4.5      Environmental Conditions

           Ambient Temperature        21.0 °C
           Relative Humidity          31.0 %

2.4.6      Test Results

           Battery Powered 3 V – Transmitting continuously

           See chapter 2.1 for results.




      COMMERCIAL-IN-CONFIDENCE                                                             Page 23 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




          FCC 47 CFR Part 15, Limit Clause 15.205

                                                 Peak (dBµV/m)                          Average (dBµV/m)
           Restricted Bands of Operation         74                                     54


                                                            Table 12

          ISED Canada RSS-GEN, Limit Clause 8.9

           Frequency (MHz)                                          Field Strength (µV/m at 3 metres)
           30-88                                                    100
           88-216                                                   150
           216-960                                                  200
           Above 960*                                               500


                                                          Table 13
          *Unless otherwise specified, for all frequencies greater than 1 GHz, the radiated emission limits for
          licence-exempt radio apparatus stated in applicable RSSs (including RSS-Gen) are based on
          measurements using a linear average detector function having a minimum resolution bandwidth of
          1 MHz. If an average limit is specified for the EUT, then the peak emission shall also be measured
          with instrumentation properly adjusted for such factors as pulse desensitization to ensure the peak
          emission is less than 20 dB above the average limit.

2.4.7     Test Location and Test Equipment Used

          This test was carried out in Semi anechoic room - cabin no. 8.

                                                                                                Calibration
           Instrument                 Manufacturer               Type No              TE No     Period        Calibration Due
                                                                                                (months)

           Loop Antenna               Rohde & Schwarz            HFH2-Z2              18876     36            2022-08-31

           TRILOG Antenna (4db)       Schwarzbeck                VULB 9162            20116     36            2022-01-31

           Horn antenna               Rohde & Schwarz            HF907                19933     24            2021-07-31

           EMI test receiver          Rohde & Schwarz            ESW26                28268     12            2020-06-30

           EMC measurement
                                      Rohde & Schwarz            EMC32-ME+            19719     N/A           N/A
           software


                                                            Table 14

          TU - Traceability Unscheduled
          O/P Mon – Output Monitored using calibrated equipment
          N/A - Not Applicable




   COMMERCIAL-IN-CONFIDENCE                                                                                   Page 24 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




2.5        Exposure of Humans to RF Fields and SAR exclusion threshold

2.5.1      Specification Reference

           IC RSS-GEN Issue 4, section 3.2 and
           IC RSS-102, Issue 5, section 2.5 and
           KDB 447498 D01 V06, section 4.3.1 a)


2.5.2      Guide

           IC RSS-102 Issue 5, section 2.5

2.5.3      Equipment Under Test and Modification State

           SK1, S/N: --- - Modification State 0

2.5.4      Date of Test

           2019-08-27

2.5.5      Test Results




      COMMERCIAL-IN-CONFIDENCE                                           Page 25 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                                                                                            Declared by




                                                                                                                                     Exemption
                                                                                              Applicable



                                                                                                                          Measured
                                                                                                             applicant
                          Exposure of Humans to RF Fields


The antenna is

    detachable

       The conducted output power (CP in watts) is measured at the antenna connector:
                                         CP = ................ W
       The effective isotropic radiated power (EIRP in watts) is calculated using
                  the numerical antenna gain:             G = ................
                                  EIRP = G  CP  EIRP = ................ W
                  the field strength1 in V/m:            FS = ................ V/m

                                   ( FS  D) 2
                            EIRP =              EIRP         = ................ W
                                       30
                  with:
                  Distance between the antennas
                                                          D = ................ m
                  in m:

    not detachable



       A field strength measurement is used to determine the effective isotropic radiated
       power (EIRP in watts) given by:


                                     ( FS  D) 2
                            EIRP =                EIRP       = 8.82 μW
                                         30
       with:
       Field strength in V/m:                            FS = 0.0054
       Distance between the two antennas in m:            D =3

Selection of output power

       The output power TP is the higher of the conducted or effective isotropic radiated
       power (e.i.r.p.):
                                            TP = 8.82 μW




1  The conversion formula is valid only for properly matched antennas. In other cases the transmitter output
power may have to be measured by a terminated measurement when applying the exemption clauses.
If an open area test site is used for field strength measurement, the effect due to the metal ground reflecting
plane should be subtracted from the maximum field strength value in order to reference it to free space,
before calculating TP.

    COMMERCIAL-IN-CONFIDENCE                                                                               Page 26 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                                                                                                                                         Declared by




                                                                                                                                                                  Exemption
                                                                                                                           Applicable



                                                                                                                                                       Measured
                                                                                                                                          applicant
                            Exposure of Humans to RF Fields (continued)


Separation distance between the user and the transmitting device is

    less than or equal to 20 cm                                             greater than 20 cm

Transmitting device is

    in the vicinity of the human head                                       body-worn

SAR evaluation
SAR evaluation is required if the separation distance between the user and/or bystander and the antenna and/or
radiating element of the device is less than or equal to 20 cm, except when the device operates at or below the
applicable output power level (adjusted for tune-up tolerance) for the specified separation distance defined in the
table.
For controlled use devices where the 8 W/kg for 1 gram of tissue applies, the exemption limits for routine
evaluation in the table are multiplied by a factor of 5. For limb-worn devices where the 10 gram value applies,
the exemption limits for routine evaluation in the table are multiplied by a factor of 2.5. If the operating frequency
of the device is between two frequencies located in the table, linear interpolation shall be applied for the
applicable separation distance. For test separation distance less than 5 mm, the exemption limits for a
separation distance of 5 mm can be applied to determine if a routine evaluation is required.
For medical implants devices, the exemption limit for routine evaluation is set at 1 mW. The output power of a
medical implants device is defined as the higher of the conducted or e.i.r.p to determine whether the device is
exempt from the SAR evaluation.

 Frequency                                  Exemption limits (mW)2 at separation distance of
   (MHz)                                                                                                          ≥50 mm
                    ≤5 mm


                                10 mm


                                              15 mm


                                                          20 mm


                                                                   25 mm


                                                                              30 mm


                                                                                       35 mm


                                                                                                40 mm


                                                                                                         45 mm




       ≤300 3           71       101           132         162      193        223      254      284      315       345
          450           52          70              88     106      123        141      159      177      195       213
          835           17          30              42        55       67         80       92    105      117       130
         1900               7       10              18        34       60         99    153      225      316       431
         2450               4           7           15        30       52         83    123      173      235       309
         3500               2           6           16        32       55         86    124      170      225       290
         5800               1           6           15        27       41         56       71       85       97     106


     Carrier frequency:                         f           = 433.92 MHz
     Distance:                                  d           = 5 mm
     Transmitter output power:                  TP          = 8.82 μW
     Limit:                                     TPlimit     = 54 mW
     SAR evaluation is documented in test report no. …




2 The excemption limit in the table are based on measurements and simulations on half-wave dipole antennas at
separaton distances of 5 mm to 25 mm from a flat phantom, providing a SAR value of approximately 0.4 W/kg for 1 g of
tissue. For low frequencies (300 MHz to 835 MHz), the exemption limits are derived from alinear fit. For high frequencies
(1900 MHz and above), the exemption limits are derived from athird order polynomial fit.
3 Transmitters operating between 3 kHz and 10 MHz, meeting the exemption from routine SAR evaluation, shall
demonstrate compliance to the instantaneous limits in IC RSS-102, issue 5, section 4.

     COMMERCIAL-IN-CONFIDENCE                                                                                                           Page 27 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




Specifications:                    RSS-102, Issue 5, Section 4, Table 4, Uncontrolled Environment
                                   SPR-002, Issue 1
Operation mode:                    Battery Powered 3 V – Transmitting continuously
Comment:                           ---



Test procedure:                             IEC 62236-1, Section 4.2 “Measurement to show accordance to the
                                            reference levels”
Test distance:                              Direct contact to EUT
Limit:                                        Frequency         Electric Field        Magnetic Field        Peference
                                             Range (MHz)          (V/mrms)              (A/mrms)           Periode (min)
                                                       10-20                27.46             0.0728                       6
                                                 300-6000           3.142   f0.3417   0.008335   f0.3417                   6
                                            f in MHz
Test positions:                             All surfaces: The antenna was moved all over the equipment under
                                            test using a test distance as stated above.




     Measured maximum value               Maximum Limit at 433.92 MHz                  Margin to reference value
                  (V/m)                                (V/m)                                      (V/m)
                  2.18                                 25.03                                      22.85


     Measured maximum value               Maximum Limit at 433.92 MHz                  Margin to reference value
                  (A/m)                                (A/m)                                      (A/m)
                 0.0058                                0.0664                                    0.0606




    COMMERCIAL-IN-CONFIDENCE                                                                               Page 28 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




SAR Exclusion threshold


          Maximum Radiated Fields Strength:                           76.83 dBµV/m
          (see chapter 2.1.6 of this test report)                     (at 3 m distance and 433.92 MHz)
          Calculated Equivalent Radiated Power:                       8.82 μW (e.i.r.p.) < 10 μW
          Minimum separation distance:                                5 mm (≤ 50 mm)
          1-g numeric threshold:                                      (100 μW / 5 mm) · √(0.43392 GHz) = 0.013
          1-g numeric threshold limit:                                3.0
          Note 1: For test distances below 5 mm according to 4.3.1 a) the test distance is fixed to 5 mm.
                                                               ( FS  D ) 2
                                                      EIRP =
                                                                   30




2.5.6     Test Location and Test Equipment Used

          This test was carried out in a non-shielded room.

                                                                                             Calibration
           Instrument                  Manufacturer                Type No           TE No   Period         Calibration Due
                                                                                             (months)
           Electromagnetic radiation
                                       Narda Safety                EMR-200           19590   36             2019-10-31
           meter

           Electric field probe        Narda Safety                Type 8.3          19591   36             2019-10-31

           Magnetic field probe        Narda Safety                Type 12.1         19592   36             2019-10-31

           Exposure level tester       Narda Safety                ELT-400           19725   24             2020-06-30


                                                                Table 15




   COMMERCIAL-IN-CONFIDENCE                                                                                 Page 29 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




3         Measurement Uncertainty

          For a 95% confidence level, the measurement uncertainties for defined systems are:

           Radio Testing

                                                                           Expanded
           Test Name                                       kp                                  Note
                                                                           Uncertainty
           Occupied Bandwidth                              2.0             ±1.14 %             2
           RF-Frequency error                              1.96            ±1 · 10-7           7
           RF-Power, conducted carrier                     2               ±0.079 dB           2
           RF-Power uncertainty for given BER              1.96            +0.94 dB / -1.05    7
           RF power, conducted, spurious emissions         1.96            +1.4 dB / -1.6 dB   7
           RF power, radiated
           25 MHz – 4 GHz                                  1.96            +3.6 dB / -5.2 dB   8
           1 GHz – 18 GHz                                  1.96            +3.8 dB / -5.6 dB   8
           18 GHz – 26.5 GHz                               1.96            +3.4 dB / -4.5 dB   8
           40 GHz – 170 GHz                                1.96            +4.2 dB / -7.1 dB   8
           Spectral Power Density, conducted               2.0             ±0.53 dB            2
           Maximum frequency deviation
           300 Hz – 6 kHz                                  2               ±2,89 %             2
           6 kHz – 25 kHz                                  2               ±0.2 dB             2
           Maximum frequency deviation for FM              2               ±2,89 %             2
           Adjacent channel power 25 MHz – 1 GHz           2               ±2.31 %             2
           Temperature                                     2               ±0.39 K             4
           (Relative) Humidity                             2               ±2.28 %             2
           DC- and low frequency AC voltage
           DC voltage                                      2               ±0.01 %             2
           AC voltage up to 1 kHz                          2               ±1.2 %              2
           Time                                            2               ±0.6 %              2


                                                     Table 16




    COMMERCIAL-IN-CONFIDENCE                                                                   Page 30 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




                       Radio Interference Emission Testing
                                                                          Expanded
           Test Name                                                kp                  Note
                                                                          Uncertainty
           Conducted Voltage Emission
           9 kHz to 150 kHz (50/50µH AMN)                          2     ± 3.8 dB      1
           150 kHz to 30 MHz (50/50µH AMN)                         2     ± 3.4 dB      1
           100 kHz to 200 MHz (50/5µH AMN)                         2     ± 3.6 dB      1
           Discontinuous Conducted Emission
           9 kHz to 150 kHz (50/50µH AMN)                          2     ± 3.8 dB      1
           150 kHz to 30 MHz (50/50µH AMN)                         2     ± 3.4 dB      1
           Conducted Current Emission
           9 kHz to 200 MHz                                         2     ± 3.5 dB      1
           Magnetic Fieldstrength
           9 kHz to 30 MHz (with loop antenna)                      2     ± 3.9 dB      1
           9 kHz to 30 MHz (large-loop antenna 2 m)                 2     ± 3.5 dB      1
           Radiated Emission
           Test distance 1 m (ALSE)
           9 kHz to 150 kHz                                         2     ± 4.6 dB      1
           150 kHz to 30 MHz                                        2     ± 4.1 dB      1
           30 MHz to 200 MHz                                        2     ± 5.2 dB      1
           200 MHz to 2 GHz                                         2     ± 4.4 dB      1
           2 GHz to 3 GHz                                           2     ± 4.6 dB      1
           Test distance 3 m
           30 MHz to 300 MHz                                        2     ± 4.9 dB      1
           300 MHz to 1 GHz                                         2     ± 5.0 dB      1
           1 GHz to 6 GHz                                           2     ± 4.6 dB      1
           Test distance 10 m
           30 MHz to 300 MHz                                        2     ± 4.9 dB      1
           300 MHz to 1 GHz                                         2     ± 4.9 dB      1
           Radio Interference Power
           30 MHz to 300 MHz                                        2     ± 3.5 dB      1
           Harmonic Current Emissions                                                   4
           Voltage Changes, Voltage Fluctuations and Flicker                            4


                                                               Table 17




   COMMERCIAL-IN-CONFIDENCE                                                             Page 31 of 32


Document Number: TR-64038-67571-02 | Issue: 01
COMMERCIAL-IN-CONFIDENCE




           Immunity Testing
                                                                               Expanded
           Test Name                                                  kp                         Note
                                                                               Uncertainty
           Electrostatic Discharges                                                              4
           Radiated RF-Field
           Pre-calibrated field level                                 2        +32.2 / -24.3 %   5
           Dynamic feedback field level                               2.05     +21.2 / -17.5 %   3
           Electrical Fast Transients (EFT) / Bursts                                             4
           Surges                                                                                4
           Conducted Disturbances, induced by RF-Fields
           via CDN                                                    2        +15.1 / -13.1 %   6
           via EM clamp                                               2        +42.6 / -29.9 %   6
           via current clamp                                          2        +43.9 / -30.5 %   6
           Power Frequency Magnetic Field                             2        +20.7 / -17.1 %   2
           Pulse Magnetic Field                                                                  4
           Voltage Dips, Short Interruptions and Voltage Variations                              4
           Oscillatory Waves                                                                     4
           Conducted Low Frequency Disturbances
           Voltage setting                                            2        ± 0.9 %           2
           Frequency setting                                          2        ± 0.1 %           2
           Electrical Transient Transmission in Road Vehicles                                    4


                                                         Table 18
          Note 1:
          The expanded uncertainty reported according to CISPR 16-4-2:2003-11 is based on a standard
          uncertainty multiplied by a coverage factor of kp = 2, providing a level of confidence of p = 95.45%
          Note 2:
          The expanded uncertainty reported according to UKAS Lab 34 (Edition 1, 2002-08) is based on a
          standard uncertainty multiplied by a coverage factor of kp = 2, providing a level of confidence of p =
          95.45%
          Note 3:
          The expanded uncertainty reported according to UKAS Lab 34 (Edition 1, 2002-08) is based on a
          standard uncertainty multiplied by a coverage factor of kp = 2.05, providing a level of confidence of
          p = 95.45%
          Note 4:
          It has been demonstrated that the used test equipment meets the specified requirements in the
          standard with at least a 95%confidence.
          Note 5:
          The expanded uncertainty reported according to IEC 61000-4-3 is based on a standard uncertainty
          multiplied by a coverage factor of kp = 2, providing a level of confidence of p = 95.45%
          Note 6:
          The expanded uncertainty reported according to IEC 61000-4-6 is based on a standard uncertainty
          multiplied by a coverage factor of kp = 2, providing a level of confidence of p = 95.45%
          Note 7:
          The expanded uncertainty reported according ETSI TR 100 028 V1.4.1 (all parts) to is based on a
          standard uncertainty multiplied by a coverage factor of kp = 1.96, providing a level of confidence of
          p = 95.45%
          Note 8:
          The expanded uncertainty reported according to ETSI TR 102 273 V1.2.1 (all parts) is based on a
          standard uncertainty multiplied by a coverage factor of kp = 1.96, providing a level of confidence of
          p = 95.45%




   COMMERCIAL-IN-CONFIDENCE                                                                      Page 32 of 32



Document Created: 2019-09-05 19:50:47
Document Modified: 2019-09-05 19:50:47

© 2024 FCC.report