Report

FCC ID: IYZDC02

Test Report

Download: PDF
FCCID_655693

Test Report No.: 05002824                       Page 1 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                    Date of issue: 2005-11-23




                                                   TTI-P-G-128/96



                                                   Test Report
                                         acc. to the relevant standard:
                                    47 CFR Part 15 C – Intentional Radiators
                                           Measurement Procedure:
                                               ANSI C63.4 - 1992
                                                    relating to
                                               Marquardt GmbH
                                                   Key DC_02



                                      Measurement of Radio- Noise Emissions
                              from Low- Voltage Electrical and Electronic Equipment
                           Technical characteristics and test methods for radio equipment
                                      in the frequency range 9 kHz to 40 GHz




m. dudde hochfrequenz-technik
Rottland 5a                                                                             Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                      Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                          http://www.dudde.com


Test Report No.: 05002824           Page 2 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                           Date of issue: 2005-11-23


Manufacturer’s details
Manufacturer                                 Marquardt GmbH
Manufacturers Grantee Code                   IYZ
Manufacturers Address                        Schloßstrasse 16
                                             D-78604 Rietheim Weilheim
                                             Germany
                                             Phone : +49 7424 99 1960
                                             Fax    : +49 7424 99 2419
                                             E- Mail: andreas.gaebler@marquardt.de
Relevant standard used                       47 CFR Part 15C - Intentional Radiators
                                             ANSI C63.4-1992



Test report prepared by
Technical engineer                           Ralf Trepper
                                             m.dudde hochfrequenz-technik (Labor)
                                             Rottland 5a
                                             D-51429 Bergisch Gladbach
                                             Germany
                                             Phone: +49 2207 96890
                                             Fax : +49 2207 968920
                                             E-mail: m.duddelabor@dudde.com




Equipment Under Test (EUT)
Equipment category                           Transmitter
Trade name                                   Marquardt
Type designation                             DC_02
Serial no.                                   ---
Variants




m. dudde hochfrequenz-technik
Rottland 5a                                                                     Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                          Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de              http://www.dudde.com


Test Report No.: 05002824                          Page 3 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                              Date of issue: 2005-11-23


0 Test result

CFR        Report Requirements                                                                         Test result
Section    Chapter Headline                                                                               OK
 15.203     10.1 Antenna requirement                                                            pass      fail       n.a.
15.231 (b)  10.2 Field strength limits (fundamental)                                            pass      fail       n.a.
15.205(b)   10.2 Radiated spurious emissions                                                    pass      fail       n.a.
 15.209
15.231 (a)      10.3      Periodic operation characteristics                                    pass      fail       n.a.
15.231 (c)      10.4      20 dB bandwidth                                                       pass      fail       n.a.


  Test requirements kept                                                                                yes no



                                                    .
Signature Technician                                ........................................
                                                    Ralf Trepper



                                                    .
Signature Manager                                  .........................................
                                                    Manfried Dudde




m. dudde hochfrequenz-technik
Rottland 5a                                                                                       Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                                Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                                    http://www.dudde.com


Test Report No.: 05002824                                               Page 4 of 21
EUT: DC_02


   FCC ID: IYZDC02                                                                                                                      Date of issue: 2005-11-23

            List of contents                                                                                                                         Page
0 Test result .............................................................................................................................................. 3
1 Testing laboratory .................................................................................................................................. 5
2 Introduction ........................................................................................................................................... 5
3 Product .................................................................................................................................................. 6
4 Test schedule ......................................................................................................................................... 6
5 Product and measurement documentation............................................................................................... 7
6 Observations and comments................................................................................................................... 7
7 Summary ............................................................................................................................................... 7
8 Conclusions .......................................................................................................................................... 8
9 Operation description............................................................................................................................. 9
10.1 Antenna requirement ......................................................................................................................... 10
10.1.1 Regulation ...................................................................................................................................... 10
10.1.2 Result ............................................................................................................................................. 10
10.2 Radiated emissions ........................................................................................................................... 11
10.2.1 Regulation ...................................................................................................................................... 11
10.2.2 Test equipment ............................................................................................................................... 12
10.2.2.1 Test procedures............................................................................................................................ 12
10.2.3 Calculation of field strength limits.................................................................................................. 13
10.2.4 Calculation of average correction factor.......................................................................................... 13
10.2.5 Calculation of the field strengths .................................................................................................... 13
10.2.6 Result ............................................................................................................................................. 14
10.3.1 Periodic operation........................................................................................................................... 16
10.3.1.1 Regulation ................................................................................................................................... 16
10.3.1.2 Result .......................................................................................................................................... 16
10.3.2 Manually operated transmitter deactivation .................................................................................... 16
10.3.2.1 Regulation ................................................................................................................................... 16
10.3.2.2 Result .......................................................................................................................................... 16
10.3.3 Automatically operated transmitter deactivation ............................................................................. 16
10.3.3.1 Regulation ................................................................................................................................... 16
10.3.3.2 Result .......................................................................................................................................... 16
10.3.4 Prohibition of periodic transmission ............................................................................................... 17
10.3.4.1 Regulation ................................................................................................................................... 17
10.3.4.2 Result .......................................................................................................................................... 17
10.3.5 Continuous transmission during an alarm condition........................................................................ 17
10.3.5.1 Regulation ................................................................................................................................... 17
10.3.5.2 Result .......................................................................................................................................... 17
10.4 Bandwidth ........................................................................................................................................ 18
10.4.1 Regulation ...................................................................................................................................... 18
10.4.2 Calculation of the 20 dB bandwidth limit ....................................................................................... 18
10.4.3 Test equipment ............................................................................................................................... 18
10.4.4 Test procedure ................................................................................................................................ 18
10.4.5 Test result ....................................................................................................................................... 19
11 Additional information to this test report .............................................................................................. 20




m. dudde hochfrequenz-technik
Rottland 5a                                                                                                                                  Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                                                      Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                                                          http://www.dudde.com


Test Report No.: 05002824                          Page 5 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                         Date of issue: 2005-11-23


1 Testing laboratory
Company Name                        : m.dudde high frequency technology
Street                              : Rottland 5a
City                                : 51429 Bergisch Gladbach
Country                             : Germany
Laboratory                          : FCC Registration Number: 699717
                                      This site has been fully described in a report submitted to the FCC, and
                                      accepted in the letter dated              Registration Number .699717
Phone                               : +49-2207-9689-0
Fax                                 : +49-2207-9689-20
E-Mail                              : manfred.dudde@t-online.de
Web                                 : http://www.dudde.com

2 Introduction

The test report may only be reproduced or published in full. Reproduction or publication of extracts
from the report requires the prior written approval of m. dudde hochfrequenz - technik.

This report contains the result of tests performed by m. dudde hochfrequenz - technik for the purpose of
a type approval. The order for carrying out these tests had been placed by:

Manufacturer
Company name                        : Marquardt GmbH
Address                             : Schloßstrasse 16
Postcode                            : D-78604
City/town                           : Rietheim-Weilheim
Country                             : Germany
Telephone                           : +49 7424 99 1960
Telefax                             : +49 7442 99 2419
E-Mail                              : andreas.gaebler@marquardt.de
Date of order                       : 2005-11-09
References                          : Mr. Andreas Gäbler




m. dudde hochfrequenz-technik
Rottland 5a                                                                                  Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                         Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                             http://www.dudde.com


Test Report No.: 05002824                     Page 6 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                  Date of issue: 2005-11-23

3 Product

Samples of the following apparatus were submitted for testing:


Type of equipment                     : Transmitter
Trademark                             : Marquardt
Type designation                      : DC_02
Hardware version                      : DC_02
Serial number                         : ---
Software release                      : ---
Equipment used power                  : 6.0VDC
Frequency used                        : 315 MHz
Generated or used frequencies         : 9.84375 MHz
FCC ID                                : IYZDC02




4 Test schedule

Tests were carried out in accordance with the specifications detailed in chapter 7 “Summary“of this report.


Tests were carried out at:
- m. dudde hochfrequenz - technik, D-51429 Bergisch Gladbach

The test sample was received on:

- 2005-11-09

The tests were carried out in the following period of time:

- 2005-11-14 - 2005-11-21




m. dudde hochfrequenz-technik
Rottland 5a                                                                           Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                    Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                        http://www.dudde.com


Test Report No.: 05002824                    Page 7 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                 Date of issue: 2005-11-23

5 Product and measurement documentation


For issuing this report the following product documentation was used and the following annexes were
created:

Description                                                          Date          Identifications
External photographs of the Equipment Under Test                     2005-11-23    Annex No. 1
Internal photographs of the Equipment Under Test                     2005-11-23    Annex No. 2
Occupied bandwidth plot                                              2005-11-23    Annex No. 3
FCC ID label sample                                                  2005-11-23    Annex No. 4
Functional description                                               2005-11-23    Annex No. 5
Test setup photos                                                    2005-11-23    Annex No. 6
Block diagram                                                        2005-11-23    Annex No. 7
Schematics                                                           2005-11-23    Annex No. 8
Periodic operation characteristics                                   2005-11-23    Annex No. 9

The above mentioned documentation will be filed at m. dudde hochfrequenz - technik for a period of 10
years following the issue of this report.



6 Observations and comments




7 Summary

The product is intended for the use in the following areas of application:
Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment
in the frequency range of 9 kHz to 40 GHz

The samples were tested according to the following specification:

47 CFR Part 15 – Intentional Radiators, ANSI C63.4 - 1992

m. dudde hochfrequenz-technik
Rottland 5a                                                                          Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                   Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                       http://www.dudde.com


Test Report No.: 05002824                    Page 8 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                   Date of issue: 2005-11-23

8 Conclusions

Samples of the apparatus were found to CONFORM WITH the specifications stated in chapter 7
"Summary" of this report.

In the opinion of m. dudde hochfrequenz - technik, the samples satisfied all applicable requirements
relating to the network interface types specified in chapter 7 "Summary".

The results of the type tests as stated in this report are exclusively applicable to the product item as
identified in this report. m. dudde hochfrequenz - technik does not accept any responsibility for the
results stated in this report, with respect to the properties of product items not involved in these tests.

This report consists of a main module, modules with test results and annexes listed in chapter 5:
“Product documentation”. All pages have been numbered consecutively and bear the m. dudde
hochfrequenz - technik logo, the report number and sub numbers.
The total number of pages in this report is 21.


Tester:

Date              : 2005-11-23

Name              : Ralf Trepper


Signature         :


Technical responsibility for area of testing:

Date              : 2004-11-23

Name              : Manfried Dudde


Signature         :




m. dudde hochfrequenz-technik
Rottland 5a                                                                             Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                   Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                       http://www.dudde.com


Test Report No.: 05002824                   Page 9 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                  Date of issue: 2005-11-23


9 Operation description
         9.1 EUT details


The DC_02 key is a component of a driver authorisation system and has the following function: Remote
control for vehicle access via radio and infrared signals. A command is transmitted to the vehicle by the
key via a HF transmitter after a button has been pressed on the key.



         9.2 EUT configuration


see Annex No 5 (Functional description)



         9.3 EUT measurement description

The Key DC_02 was tested in a typical fashion.. During preliminary emission tests the Key DC_02 was
operated in continuous transmitting mode for worst case emission mode investigation. Therefore, final
qualification testing was completed with Key DC_02 operated in all continuous modes. All tests
performed with applicant typical voltage (6 Volts DC).




m. dudde hochfrequenz-technik
Rottland 5a                                                                           Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                  Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                      http://www.dudde.com


Test Report No.: 05002824                       Page 10 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                           Date of issue: 2005-11-23

10.1 Antenna requirement

10.1.1 Regulation

15.203 An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an antenna that
uses a unique coupling to the intentional radiator shall be considered sufficient to comply with the provisions of
Part 15C. The manufacturer may design the unit so that the user can replace a broken antenna, but the use of a
standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current
devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or 15.221.
Further, this requirement does not apply to intentional radiators that must be professionally installed, such as
perimeter protection systems and some field disturbance sensors, or to other intentional radiators which, in
accordance with Section 15.31 (d), must be measured at the installation site. However, the installer shall be
responsible for ensuring that the proper antenna is employed so that the limits in this Part are not exceeded.


10.1.2 Result


The equipment meets the requirements                                                    yes        no       n.a.

Further test results are attached                                         yes          no      page no:


n.a x   see page no. 20




m. dudde hochfrequenz-technik
Rottland 5a                                                                                    Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                       Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                           http://www.dudde.com


Test Report No.: 05002824                        Page 11 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                        Date of issue: 2005-11-23

10.2 Radiated emissions

10.2.1 Regulation

Test requirement: FCC CFR47, Part 15C Test procedure: ANSI C63.4:1992

Fundamental frequency               Field strength of fundamental    Field strength of spurious emissions
(MHz)                               (microvolts/meter)               (microvolts/meter)
40.66 - 40.70                       2,250                            225
70-130                              1,250                            125
130-174                             1,250 to 3,750                   125 to 375
174-260                             3,750                            375
260-470                             3,750 to 12,500                  375 to 1,250
Above 470                           12,500                           1,250

** Linear interpolations

[Where F is the frequency in MHz, the formulas for calculating the maximum permitted fundamental field
strengths are as follows: for the band 130-174 MHz, µV/m at 3 meters = 56.81818(F) - 6136.3636; for the band
260-470 MHz, µV/m at 3 meters = 41.6667(F) - 7083.3333. The maximum permitted unwanted emission level is
20 dB below the maximum permitted fundamental level.]

(1) The above field strength limits are specified at a distance of 3 meters. The tighter limits apply at the
band edges.

(2) Intentional radiators operating under the provisions of this Section shall demonstrate compliance
with the limits on the field strength of emissions, as shown in the above table, based on the average
value of the measured emissions. As an alternative, compliance with the limits in the above table may be
based on the use of measurement instrumentation with a CISPR quasi-peak detector. The specific
method of measurement employed shall be specified in the application for equipment authorization. If
average emission measurements are employed, the provisions in Section 15.35 for averaging pulsed
emissions and for limiting peak emissions apply. Further, compliance with the provisions of Section
15.205 shall be demonstrated using the measurement instrumentation specified in that section.

(3) The limits on the field strength of the spurious emissions in the above table are based on the
fundamental frequency of the intentional radiator. Spurious emissions shall be attenuated to the average
(or, alternatively, CISPR quasi-peak) limits shown in this table or to the general limits shown in Section
15.209, whichever limit permits a higher field strength.

Section 15.33 Frequency range of radiated measurements: (a) Unless otherwise noted in the specific rule
section under which the equipment operates for an intentional radiator the spectrum shall be
investigated from the lowest radio frequency signal generated in the device, without going below 9 kHz,
up to at least the frequency shown in this paragraph: (1 ). If the intentional radiator operates below 10
GHz: to the tenth harmonic of the highest fundamental frequency or to 40 GHz, whichever is lower.




m. dudde hochfrequenz-technik
Rottland 5a                                                                                 Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                       Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                           http://www.dudde.com


Test Report No.: 05002824                        Page 12 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                           Date of issue: 2005-11-23

10.2.2 Test equipment

Type              Manufacturer/               Serial no.           Last calibration       Next calibration
                  Model No.
Receiver          Hewlett Packard             3528U00990           2004/02                2006/02
                  Spectrum Analyzer
(9 kHz –26.5 GHz) 8593E (171)
Pre-amplifier     Hewlett Packard             1726A00705           2002/04                2006/04
(100kHz - 1.3GHz) 8447 E (166a)
Bilog antenna     CHASE                       1517                 2002/04                2008/04
(30- 1000 MHz)    CBL611A (167)
Horn antenna      Schwarzbeck                 236                  1998/01                2008/01
(0,86-8,5 GHz)    BBHA 9120 A (284)

10.2.2.1 Test procedures

The EUT and this peripheral (when additional equipment exist) are placed on a turn table which is 0.8m
above the ground. The turn table would be allowed to rotate 360 degrees to determine the position of the
maximum emission level. The test distance between the EUT and the receiving antenna are 3m. To find
the maximum emission, the polarization of the receiving antenna are changed in horizontal and vertical
polarization, the position of the EUT was changed in different orthogonal determinations.
ANSI C63.4: 1992 Section 8 “Radiated Emissions Testing”


Radiated emissions test characteristics
Frequency range                                            30 MHz - 4,000 MHz
Test distance                                              3 m*
Test instrumentation resolution bandwidth                  120 kHz (30 MHz - 1,000 MHz)
                                                           1 MHz (1000 MHz - 4,000 MHz)
Receive antenna scan height                                1m-4m
Receive antenna polarization                               Vertical/horizontal

* According to Section 15.31 (f)(1): At frequencies at or above 30 MHz, measurements may be performed at a
distance other than what is specified provided: measurements are not made in the near field except where it can be
shown that near field measurements are appropriate due to the characteristics of the device; and it can be
demonstrated that the signal levels needed to be measured at the distance employed can be detected by the
measurement equipment. When performing measurements at a distance other than that specified, the results shall
be extrapolated to the specified distance using an extrapolation factor of 20 dB/decade (inverse linear-distance for
field strength measurements; inverse-linear-distance-squared for power density measurements).




m. dudde hochfrequenz-technik
Rottland 5a                                                                                    Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                         Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                             http://www.dudde.com


Test Report No.: 05002824                         Page 13 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                        Date of issue: 2005-11-23

10.2.3 Calculation of field strength limits

For example: Transmitter working on 315 MHz
Limit for average measurements → 41.6667*(315 MHz) – 7083.3333 = 6041.677µV/m = 75.6dBµV/m @3m
Limit for peak measurements → Limit for average measurements + 20dB = 95.6dBµV/m @3m

10.2.4 Calculation of average correction factor

The average correction factor is computed by analyzing the "worst case" on time in any 100msec time period and
using the formula: Corrections Factor + 20*log (worst case on time/100msec). Analysis of the remote transmitter
worst case on time in any 100msec time period is an on time of 50msec, therefore the correction factor is 20*log
(50/100) = - 6 dB. The maximum correction factor to be applied is 20 dB per section 15.35 of the FCC rules.

10.2.5 Calculation of the field strengths

The field strength is calculated by the following calculation:

Corrected Level = Receiver Level + Correction Factor (without the use of an pre-amplifier)

Corrected Level = Receiver Level + Correction Factor – Pre-Amplifier (with the use of an pre-amplifier)

Receiver Level             : Receiver reading without correction factors
Correction Factor          : Antenna factor + cable loss

For example:
The receiver reading is 32.7 dBµV. The antenna factor for the measured frequency is +2.5 dB(1/m) and
the cable factor for the measured frequency is 0.71 dB, giving a field strength of 35.91dBµV/m.
The 35.91dBµV/m value can be mathematically converted to its corresponding level in µV/m.

Level in µV/m = Common Antilogarithm (35.91/20) = 39.8

For test distance other than what is specified, but fulfilling the requirements of Section 15.31 (f)(1) the
field strength is calculated by adding additionally an extrapolation factor of 20 dB/decade (inverse
linear distance for field strength measurements).




m. dudde hochfrequenz-technik
Rottland 5a                                                                                  Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                            Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                                http://www.dudde.com


     Test Report No.: 05002824                                   Page 14 of 21
     EUT: DC_02


       FCC ID: IYZDC02                                                                                                     Date of issue: 2005-11-23



    10.2.6 Result


                              TRANSMITTER SPURIOUS RADIATION (Section 15.231(b))
                                                                                                                               Polarisation      Antenna
    f           Bandwidth          Noted          Test      Correction    Distance       Level         Limit        Margin
                                                                                                                                  EUT             height
  (MHz)          (kHz) /       receiver level   distance      factor      extrapol.    corrected
                                                                                                                                    /
                  Type                                                     factor                                                antenna
                of detector       dBµV            m            dB           dB         dBµV/m      dBµV/m       dBµV/m                               cm

315.01363       120 / QPK                          3          -7.50                                75.6
                                  73.56                                      0           66.1                        9.5          V/V                149

                 120 / AV                          3          -7.50                                75.6
                                  73.52                                      0           66.0                        9.6          V/V                149

630.02726       120 / QPK                          3          -1.90                                55.6
                                  46.51                                      0           44.6                       11.0          V/V                142

                 120 / AV                          3          -1.90                                55.6
                                  46.47                                      0           44.6                       11.0          V/V                142

945.04089       120 / QPK                          3          +1.20                                55.6
                                  32.21                                      0           33.4                       22.2          V/V                191

                 120 / AV                          3          +1.20                                55.6
                                  30.88                                      0           32.1                       23.5          V/V                191

1260.05452      1000 / AV                          3          +29.7                                55.6
                                  10.47                                      0           40.2                       15.4          V/V                147

1575.06815      1000 / AV                          3         +25.63                                55.6
                                  10.19                                      0           35.8                       19.8          V/V                118

1890.08178      1000 / AV                          3         +26.57                                55.6
                                   9.10                                      0           35.7                       19.9          V/V                183

2205.09541      1000 / AV                                    +27.27                                54.0
                                   < 10            3                         0          37.27                       16.73       H,V/H,V          100-400

2520.10904      1000 / AV                                    +27.82                                55.6
                                   < 10            3                         0          37.82                       17.78       H,V/H,V          100-400

2835.12267      1000 / AV                                    +28.07                                54.0
                                   < 10            3                         0          38.07                       15.93       H,V/H,V          100-400

3150.13630      1000 / AV                                    +28.59                                55.6
                                   < 10            3                         0          38.57                       17.03       H,V/H,V          100-400

3465.14993      1000 / AV                                    +29.41                                55.6
                                   < 10            3                         0          39.41                       16.19       H,V/H,V          100-400

                                                   3

                                                   3

   Measurement uncertainty                                                                      4 dB
                                                       * Bandwidth = the measuring receiver bandwidth
    Remark: *1 noise floor noise level of the measuring instrument ≤ 3.5dBµV @ 3m distance (30 – 1,000 MHz)
    Remark: *2 noise floor noise level of the measuring instrument ≤ 4.5 dBµV @ 3m distance (1,000 – 2,000 MHz)
    Remark: *3 noise floor noise level of the measuring instrument ≤ 10 dBµV @ 3m distance (2,000 – 5,500 MHz)
    Remark: *4 noise floor noise level of the measuring instrument ≤ 14 dBµV @ 3m distance (5,500 – 14,500 MHz)
    Remark: *5 for using a pre-amplifier in the range between 100 kHz and 1,000 MHz
    Remark: *6 for using a pre-amplifier in the range between 4.0 GHz and 18.0 GHz

     The equipment meets the requirements                                                                            yes       no             n.a.

     Further test results are attached                                                       yes               no


    n.a x    see page no. 23



    m. dudde hochfrequenz-technik
    Rottland 5a                                                                                                               Vers. date: 2004-08
    D-51429 Bergisch Gladbach
    Tel.: +49 2207-9689-0                                                        Fax: +49 2207 9689-20
    e-mail: manfred.dudde@t-online.de                                            http://www.dudde.com


      Test Report No.: 05002824                                   Page 15 of 21
      EUT: DC_02


           FCC ID: IYZDC02                                                                                         Date of issue: 2005-11-23


                TRANSMITTER SPURIOUS RADIATION ABOVE 30 MHz (Section 15.205, 15.209)
                                                                                  AV                                                Polaris.    Antenna
    f         Bandwidth      Noted       Test     Correction       Distance                   Level      Limit     Margin
                                                                               Correction                                            EUT         height
  (MHz)         (kHz)       receiver   distance     factor         extrapol.                corrected
                                                                                 factor                                                /
                Type         level                                  factor                                                          antenna
              of detector   dBµV         m           dB              dB                     dBµV/m      dBµV/m     dBµV/m
                                                                                  dB                                                              cm

 30.0000       100, AV       ≤ 3.5        3         -2.60             0            0          0.90       40.00         39.10        H,V/H,V     100-400

 88.0000       100, AV       ≤ 3.5        3        -10.80             0            0         -7.30       40.00         47.30        H,V/H,V     100-400

 216.0000      100, AV       ≤ 3.5        3        -10.30             0            0         -6.80       43.50         50.30        H,V/H,V     100-400

 960.0000      100, AV       ≤ 3.5        3         8.50              0            0         12.00       43.50         31.50        H,V/H,V     100-400

1700.0000      1000, AV      ≤ 4.5        3         3.80              0            0          8.30       54.00         45.70        H,V/H,V     100-400

2250.0000      1000, AV      ≤ 10         3         8.00              0            0         18.00       54.00         36.00        H,V/H,V     100-400

4000.0000      1000, AV      ≤ 10         3                6          0            0         18.40       54.00         35.60        H,V/H,V     100-400
                                                   8.40*

5000.0000      1000, AV      ≤ 10         3                6          0            0         19.40       54.00         34.60        H,V/H,V     100-400
                                                   9.10*

7500.0000      1000, AV      ≤ 14         3               6           0            0         26.90       54.00         27.10        H,V/H,V     100-400
                                                  12.9* 0

8300.0000      1000, AV      ≤ 14         3                   6       0            0         28.80       54.00         25.20        H,V/H,V     100-400
                                                  14.80*

9400.0000      1000, AV      ≤ 14         3                   6       0            0         30.00       54.00         24.00        H,V/H,V     100-400
                                                  16.00*

11000.0000     1000, AV      ≤ 14         3                   6       0            0         32.25       54.00         21.75        H,V/H,V     100-400
                                                  18.25*



 Measurement uncertainty                                                                    4 dB
                                                  * Bandwidth = the measuring receiver bandwidth
     Remark: *1 noise floor noise level of the measuring instrument ≤ 3.5dBµV @ 3m distance (30 – 1,000 MHz)
     Remark: *2 noise floor noise level of the measuring instrument ≤ 4.5 dBµV @ 3m distance (1,000 – 2,000 MHz)
     Remark: *3 noise floor noise level of the measuring instrument ≤ 10 dBµV @ 3m distance (2,000 – 5,500 MHz)
     Remark: *4 noise floor noise level of the measuring instrument ≤ 14 dBµV @ 3m distance (5,500 – 14,500 MHz)
     Remark: *5 for using a pre-amplifier in the range between 100 kHz and 1,000 MHz
     Remark: *6 for using a pre-amplifier in the range between 4.0 GHz and 18.0 GHz


      The equipment meets the requirements                                                                       yes           no        n.a.

      Further test results are attached                                                     yes           no              page no:


     n.a x   see page no. 23




     m. dudde hochfrequenz-technik
     Rottland 5a                                                                                                          Vers. date: 2004-08
     D-51429 Bergisch Gladbach
     Tel.: +49 2207-9689-0                                                     Fax: +49 2207 9689-20
     e-mail: manfred.dudde@t-online.de                                         http://www.dudde.com


Test Report No.: 05002824                      Page 16 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                        Date of issue: 2005-11-23

10.3 Periodic operation characteristics

10.3.1 Periodic operation

10.3.1.1 Regulation

15.231 (a) The provisions of this Section are restricted to periodic operation within the band 40.66 40.70
MHz and above 70 MHz. Except as shown in paragraph (e) of this Section, the intentional radiator is
restricted to the transmission of a control signal such as those used with alarm systems, door openers,
remote switches, etc. Radio control of toys is not permitted. Continuous transmissions, such as voice or
video, and data transmissions are not permitted. The prohibition against data transmissions does not
preclude the use of recognition codes. Those codes are used to identify the sensor that is activated or to
identify the particular component as being part of the system.

10.3.1.2 Result

The equipment meets the requirements                                                   yes    no        n.a.

Further test results are attached                                    yes          no         Annex no: 5

10.3.2 Manually operated transmitter deactivation

10.3.2.1 Regulation

15.231 (a1) A manually operated transmitter shall employ a switch that will automatically deactivate the
transmitter within not more than 5 seconds of being released

10.3.2.2 Result

The equipment meets the requirements                                                   yes    no        n.a.

Further test results are attached                                    yes          no         Annex no: 9

10.3.3 Automatically operated transmitter deactivation

10.3.3.1 Regulation

15.231 (a2) A transmitter activated automatically shall cease transmission within 5 seconds after
activation.

10.3.3.2 Result

The equipment meets the requirements                                                   yes    no        n.a.

Further test results are attached                                    yes          no         page no:
m. dudde hochfrequenz-technik
Rottland 5a                                                                                  Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                     Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                         http://www.dudde.com


Test Report No.: 05002824                     Page 17 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                         Date of issue: 2005-11-23


10.3.4 Prohibition of periodic transmission


10.3.4.1 Regulation

15.231 (a3) Periodic transmissions at regular predetermined intervals are not permitted. However,
polling or supervision transmissions to determine system integrity of transmitters used in security or
safety applications are allowed if the periodic rate of transmission does not exceed one transmission of
not more than one second duration per hour for each transmitter.


10.3.4.2 Result


The equipment meets the requirements                                                    yes    no        n.a.

Further test results are attached                                     yes          no         page no:


10.3.5 Continuous transmission during an alarm condition


10.3.5.1 Regulation

15.231 (a4) Intentional radiators which are employed for radio control purposes during emergencies
involving fire, security, and safety of life, when activated to signal an alarm, may operate during the
pendency of the alarm condition.


10.3.5.2 Result


The equipment meets the requirements                                                    yes    no        n.a.

Further test results are attached                                     yes          no         page no:




m. dudde hochfrequenz-technik
Rottland 5a                                                                                   Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                      Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                          http://www.dudde.com


Test Report No.: 05002824                         Page 18 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                     Date of issue: 2005-11-23

10.4 Bandwidth

10.4.1 Regulation

15.231 (c) The bandwidth of the emission shall be no wider than 0.25% of the centre frequency for
devices operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the
emission shall be no wider than 0.5% of the centre frequency. Bandwidth is determined at the points 20
dB down from the modulated carrier.


10.4.2 Calculation of the 20 dB bandwidth limit

The 20 dB bandwidth limit = 0.0025 * 315 MHz = 0.7875 MHz = 787.5 kHz

10.4.3 Test equipment



Type                    Manufacturer/       Serial no.            Last calibration   Next calibration
                        Model no.
Receiver                Hewlett Packard     3528U00990            2004/02            2006/02
(30MHz - 1GHz)          Spectrum Analyzer
                        (171)
                        8593 E
Test fixture            Dudde               ---



10.4.4 Test procedure

ANSI C63.4-1992 Section 13.1.7 Occupied bandwidth measurements. The bandwidth is measured at an
amplitude level reduced from the reference level by a specified ratio. The reference level is the level of
the highest amplitude signal observed from the transmitter at either the fundamental frequency or
first-order modulation products in all typical modes of operation, including the unmodulated carrier,
even if atypical. Once the reference level is established, the equipment is conditioned with typical
modulating signals to produce worst-case (i.e., the widest) bandwidth. In order to measure the
modulated signal properly, a resolution bandwidth that is small compared to the bandwidth required by
the procuring or regulatory agency shall be used on the measuring instrument. However, the 6 dB
resolution bandwidth of the measuring instrument shall be set to a value greater than 5% of the
bandwidth requirements.




m. dudde hochfrequenz-technik
Rottland 5a                                                                              Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                        Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                            http://www.dudde.com


Test Report No.: 05002824                        Page 19 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                            Date of issue: 2005-11-23



10.4.5 Test result

The measured 20 dB bandwidth is: .................93.70 kHz


The equipment meets the requirements                                                       yes    no        n.a.

Further test results are attached                                        yes          no         Annex no: 3




m. dudde hochfrequenz-technik
Rottland 5a                                                                                      Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                         Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                             http://www.dudde.com


Test Report No.: 05002824                         Page 20 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                                            Date of issue: 2005-11-23


11 Additional information to this test report


                                                        Remarks

n.a.1                               not applicable, because the antenna is part of the PCB

n.a.2                               not applicable, because the EUT is directly battery powered




m. dudde hochfrequenz-technik
Rottland 5a                                                                                     Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                                         Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                             http://www.dudde.com


Test Report No.: 05002824             Page 21 of 21
EUT: DC_02


  FCC ID: IYZDC02                                                        Date of issue: 2005-11-23




                                    End of test report




m. dudde hochfrequenz-technik
Rottland 5a                                                                 Vers. date: 2004-08
D-51429 Bergisch Gladbach
Tel.: +49 2207-9689-0                            Fax: +49 2207 9689-20
e-mail: manfred.dudde@t-online.de                http://www.dudde.com



Document Created: 2006-03-16 16:34:38
Document Modified: 2006-03-16 16:34:38

© 2024 FCC.report