Test Report

FCC ID: IYZ335038

Test Report

Download: PDF
FCCID_4415570

                                                          TEST REPORT
                                              Test report no.: 1-7492/18-01-02-A                                               D-PL-12076-01-03




                  Testing laboratory                                                           Applicant
 CTC advanced GmbH                                                          Marquardt GmbH
 Untertuerkheimer Strasse 6 – 10                                            Schloss-Str. 16
 66117 Saarbruecken / Germany                                               78604 Rietheim-Weilheim / GERMANY
 Phone:    + 49 681 5 98 - 0                                                Phone:    +49 7424 99-0
 Fax:      + 49 681 5 98 - 9075                                             Contact: Gerd Siegel
 Internet: http://www.ctcadvanced.com                                       e-mail:   Gerd.Siegel@marquardt.de
 e-mail:   mail@ctcadvanced.com                                             Phone:    +49 (0) 74 24 - 99 1589
 Accredited Testing Laboratory:
 The testing laboratory (area of testing) is accredited
 according to DIN EN ISO/IEC 17025 (2005) by the
 Deutsche Akkreditierungsstelle GmbH (DAkkS)                                                 Manufacturer
 The accreditation is valid for the scope of testing                        Marquardt GmbH
 procedures as stated in the accreditation certificate with                 Schloss-Str. 16
 the registration number: D-PL-12076-01-03                                  78604 Rietheim-Weilheim / GERMANY


                                                               Test standard/s
 FCC - Title 47 CFR            FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio
 Part 15                       frequency devices
                               Spectrum Management and Telecommunications Radio Standards Specification -
 RSS - 210 Issue 9
                               Licence-Exempt Radio Apparatus: Category I Equipment
                               Spectrum Management and Telecommunications Radio Standards Specification
 RSS - Gen Issue 5
                               - General Requirements for Compliance of Radio Apparatus
 For further applied test standards please refer to section 3 of this test report.


                                                                     Test Item
 Kind of test item:           BCM Steuergerät mit 21.845 KHz
 Model name:                  3350.38
 FCC ID:                      IYZ335038
 IC:                          2701A-335038
 Frequency:                   21.845 kHz
 Technology tested:           Keyless entry
 Antenna:                     4 external antennas
 Power supply:                12 V DC by external power supply / car battery
 Temperature range:           -20°C to +80°C

This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.

 Test report authorized:                                                  Test performed:
                               cn=Christoph Schneider, o=CTC advanced                               cn=Tobias Wittenmeier, o=CTC advanced
                               GmbH, ou=SND-161128,                                                 GmbH, ou=WIT-170519,
                               email=Christoph.Schneider@ctcadvanced.c                              email=tobias.wittenmeier@ctcadvanced.co
                               om, c=DE                                                             m, c=DE
                               2019.08.13 11:08:18 +02'00'                                          2019.08.13 13:11:45 +02'00'

 Christoph Schneider                                                      Tobias Wittenmeier
 Lab Manager                                                              Testing Manager
 Radio Communications & EMC                                               Radio Communications & EMC


                  Test report no.: 1-7492/18-01-02-A




1      Table of contents

1    Table of contents ............................................................................................................................................ 2
2    General information ....................................................................................................................................... 3
     2.1       Notes and disclaimer .......................................................................................................................... 3
     2.2       Application details ............................................................................................................................... 3
     2.3       Test laboratories sub-contracted ...................................................................................................... 3
3    Test standard/s and references .................................................................................................................... 4
4    Test environment............................................................................................................................................ 5
5    Test item .......................................................................................................................................................... 5
     5.1       General description ............................................................................................................................. 5
     5.2       Additional information ........................................................................................................................ 5
6    Description of the test setup ......................................................................................................................... 6
     6.1       Shielded semi anechoic chamber ...................................................................................................... 7
     6.2       Shielded fully anechoic chamber ...................................................................................................... 8
     6.3       Test setup for normalized measurement configurations ................................................................ 9
7    Sequence of testing .....................................................................................................................................10
     7.1       Sequence of testing radiated spurious 9 kHz to 30 MHz ...............................................................10
     7.2       Sequence of testing radiated spurious 30 MHz to 1 GHz ..............................................................11
8    Measurement uncertainty ............................................................................................................................12
9    Summary of measurement results .............................................................................................................13
10      Additional comments ...............................................................................................................................13
11      Measurement results ................................................................................................................................14
     11.1          Occupied bandwidth......................................................................................................................14
     11.2          Field strength of the fundamental ................................................................................................16
     11.3          Field strength of the harmonics and spurious ...........................................................................17
12      Observations .............................................................................................................................................19
Annex A            Glossary ..........................................................................................................................................20
Annex B            Document history ..........................................................................................................................21
Annex C            Accreditation Certificate ...............................................................................................................21




© CTC advanced GmbH                                                                                                                                      Page 2 of 21


             Test report no.: 1-7492/18-01-02-A




2      General information

2.1    Notes and disclaimer
The test results of this test report relate exclusively to the test item specified in this test report. CTC advanced
GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with
regard to other specimens or samples of the type of the equipment represented by the test item.
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report
requires the prior written approval of CTC advanced GmbH.
The testing service provided by CTC advanced GmbH has been rendered under the current "General Terms and
Conditions for CTC advanced GmbH".
CTC advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate or
incomplete product information provided by the customer.
Under no circumstances does the CTC advanced GmbH test report include any endorsement or warranty
regarding the functionality, quality or performance of any other product or service provided.
Under no circumstances does the CTC advanced GmbH test report include or imply any product or service
warranties from CTC advanced GmbH, including, without limitation, any implied warranties of merchantability,
fitness for purpose, or non-infringement, all of which are expressly disclaimed by CTC advanced GmbH.
All rights and remedies regarding vendor’s products and services for which CTC advanced GmbH has prepared
this test report shall be provided by the party offering such products or services and not by CTC advanced GmbH.
In no case this test report can be considered as a Letter of Approval.

This test report is electronically signed and valid without handwritten signature. For verification of the electronic
signatures, the public keys can be requested at the testing laboratory.

This test report replaces the test report with the number 1-7492/18-01-02 and dated 2019-08-08.

2.2    Application details
Date of receipt of order:                2019-01-13
Date of receipt of test item:            2019-02-18
Start of test:                           2019-02-18
End of test:                             2019-08-08
Person(s) present during the test:       -/-



2.3    Test laboratories sub-contracted
None




 © CTC advanced GmbH                                                                                     Page 3 of 21


           Test report no.: 1-7492/18-01-02-A




3    Test standard/s and references
Test standard                Date         Description
                                          FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part
FCC - Title 47 CFR Part 15   -/-
                                          15 - Radio frequency devices
                                          Spectrum Management and Telecommunications Radio Standards
                             August
RSS - 210 Issue 9                         Specification - Licence-Exempt Radio Apparatus: Category I
                             2016
                                          Equipment
                                          Spectrum Management and Telecommunications Radio Standards
RSS - Gen Issue 5            April 2018   Specification
                                          - General Requirements for Compliance of Radio Apparatus



Guidance                     Version      Description

                                          American National Standard for Methods of Measurement of
ANSI C63.4-2014              -/-          Radio-Noise Emissions from Low-Voltage Electrical and Electronic
                                          Equipment in the Range of 9 kHz to 40 GHz
                                          American National Standard of Procedures for Compliance
ANSI C63.10-2013             -/-
                                          Testing of Unlicensed Wireless Devices




© CTC advanced GmbH                                                                               Page 4 of 21


             Test report no.: 1-7492/18-01-02-A




4     Test environment

                                   Tnom    +22 °C during room temperature tests
Temperature                  :     Tmax    No tests under extreme temperature conditions required.
                                   Tmin    No tests under extreme temperature conditions required.
Relative humidity content    :             45 %
Barometric pressure          :             1022 hpa
                                   Vnom    12 V DC by external power supply / car battery
Power supply                 :     Vmax    No tests under extreme voltage conditions required.
                                   Vmin    No tests under extreme voltage conditions required.



5     Test item

5.1   General description

Kind of test item            :   BCM Steuergerät mit 21.845 KHz
Type identification          :   3350.38
HMN                          :   -/-
PMN                          :   3350.38
HVIN                         :   3350.38
FVIN                         :   -/-
S/N serial number            :   No serial number available.
Hardware status              :   TBD
Software status              :   TBD
Firmware status              :   TBD
Frequency band               :   21.845 kHz
Type of radio transmission   :
                                 modulated carrier
Use of frequency spectrum    :
Type of modulation           :   PSK
Number of channels           :   1
Antenna                      :   4 external antennas
Power supply                 :   12 V DC by external power supply / car battery
Temperature range            :   -20°C to +80°C



5.2   Additional information
The content of the following annexes is defined in the QA. It may be that not all of the listed annexes are
necessary for this report, thus some values in between may be missing.

Test setup and EUT photos are included in test report:           1-7492/18-01-01_AnnexA
                                                                 1-7492/18-01-01_AnnexB
                                                                 1-7492/18-01-01_AnnexD




 © CTC advanced GmbH                                                                                   Page 5 of 21


                  Test report no.: 1-7492/18-01-02-A




6           Description of the test setup
Typically, the calibrations of the test apparatus are commissioned to and performed by an accredited calibration
laboratory. The calibration intervals are determined in accordance with the DIN EN ISO/IEC 17025. In addition to
the external calibrations, the laboratory executes comparison measurements with other calibrated test systems
or effective verifications. Weekly chamber inspections and range calibrations are performed. Where possible, RF
generating and signaling equipment as well as measuring receivers and analyzers are connected to an external
high-precision 10 MHz reference (GPS-based or rubidium frequency standard).

In order to simplify the identification of the equipment used at some special tests, some items of test equipment
and ancillaries can be provided with an identifier or number in the equipment list below (Lab/Item).



Agenda: Kind of Calibration

    k        calibration / calibrated                     EK    limited calibration
    ne       not required (k, ev, izw, zw not required)   zw    cyclical maintenance (external cyclical
                                                                maintenance)
    ev       periodic self verification                   izw   internal cyclical maintenance
    Ve       long-term stability recognized               g     blocked for accredited testing
    vlkI!    Attention: extended calibration interval
    NK!      Attention: not calibrated                    *)    next calibration ordered / currently in progress




 © CTC advanced GmbH                                                                                      Page 6 of 21


                Test report no.: 1-7492/18-01-02-A




6.1     Shielded semi anechoic chamber
The radiated measurements are performed in vertical and horizontal plane in the frequency range from 30 MHz
to 1 GHz in semi-anechoic chambers. The EUT is positioned on a non-conductive support with a height of 0.80
m above a conductive ground plane that covers the whole chamber. The receiving antennas are conform to
specifications ANSI C63. These antennas can be moved over the height range between 1.0 m and 4.0 m in order
to search for maximum field strength emitted from EUT. The measurement distances between EUT and receiving
antennas are indicated in the test setups for the various frequency ranges. For each measurement, the EUT is
rotated in all three axes until the maximum field strength is received. The wanted and unwanted emissions are
received by spectrum analyzers where the detector modes and resolution bandwidths over various frequency
ranges are set according to requirement ANSI C63.




Measurement distance: tri-log antenna 10 meter
EMC32 software version: 10.30.0

FS = UR + CL + AF
(FS-field strength; UR-voltage at the receiver; CL-loss of the cable; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 12.35 [dBµV/m] + 1.90 [dB] + 16.80 [dB/m] = 31.05 [dBµV/m] (35.69 µV/m)

Equipment table:

        Lab /                                                                                          Kind of       Last        Next
  No.               Equipment               Type            Manufacturer       Serial No.    INV. No.
        Item                                                                                          Calibration Calibration Calibration
 1        A         Switch-Unit             3488A                HP            2719A14505   300000368     ev           -/-         -/-
                 DC power supply,
 2       A                                  6032A                HP            2920A04466   300000580      ne          -/-          -/-
                60Vdc, 50A, 1200 W
 3       A         Meßkabine 1         HF-Absorberhalle    MWB AG 300023           -/-      300000551       ne         -/-          -/-
 4       A       EMI Test Receiver         ESCI 3              R&S               100083     300003312        k     12.12.2018   11.12.2019
 5       A        Antenna Tower          Model 2175         ETS-Lindgren         64762      300003745      izw         -/-          -/-
                    Positioning
 6       A                               Model 2090         ETS-Lindgren         64672      300003746      izw         -/-          -/-
                     Controller
                Turntable Interface-
 7       A                              Model 105637        ETS-Lindgren         44583      300003747      izw         -/-          -/-
                        Box
                TRILOG Broadband
                                                          Schwarzbeck Mess -
 8       A        Test-Antenna 30         VULB9163                                371       300003854     vlKI!    24.11.2017   23.11.2020
                                                              Elektronik
                   MHz - 3 GHz



 © CTC advanced GmbH                                                                                                         Page 7 of 21


                Test report no.: 1-7492/18-01-02-A




6.2     Shielded fully anechoic chamber




Measurement distance: loop antenna 3 meter

FS = UR + CA + AF
(FS-field strength; UR-voltage at the receiver; CA-loss of the signal path; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 40.0 [dBµV/m] + (-35.8) [dB] + 32.9 [dB/m] = 37.1 [dBµV/m] (71.61 µV/m)


Equipment table:

        Lab /                                                                                             Kind of       Last        Next
  No.               Equipment             Type            Manufacturer          Serial No.    INV. No.
        Item                                                                                             Calibration Calibration Calibration
                    NEXIO EMV-         BAT EMC
 1       A                                                   EMCO                  -/-       300004682       ne          -/-          -/-
                      Software         V3.16.0.49
 2       A       Anechoic chamber          -/-                TDK                  -/-       300003726       ne          -/-          -/-
                 EMI Test Receiver
 3       A                               ESR26                R&S                101376      300005063       k       19.12.2018   18.12.2019
                   9kHz-26,5GHz
                Active Loop Antenna
 4       A                                6502               EMCO                 2210       300001015      vlKI!    07.07.2017   06.07.2019
                  9 kHz to 30 MHz
                 DC power supply,
 5       A                               6032A                 HP              2920A04590    300001041      vlKI!    14.12.2017   13.12.2020
                60Vdc, 50A, 1200 W
                    4U RF Switch
 6       A                               L4491A        Agilent Technologies   MY50000032     300004510       ne          -/-          -/-
                      Platform
                                       Intel Core i3
                                                                              2V2403033A54
 7       A          Computer          3220/3,3 GHz,             -/-                          300004591       ne          -/-          -/-
                                                                                   21
                                        Prozessor




 © CTC advanced GmbH                                                                                                           Page 8 of 21


                Test report no.: 1-7492/18-01-02-A




6.3     Test setup for normalized measurement configurations




FS = UR + CA + AF
(FS-field strength; UR-voltage at the receiver; CA-loss of the signal path; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 40.0 [dBµV/m] + (-35.8) [dB] + 32.9 [dB/m] = 37.1 [dBµV/m] (71.61 µV/m)


Equipment table:

        Lab /                                                                                       Kind of       Last        Next
  No.               Equipment              Type          Manufacturer     Serial No.    INV. No.
        Item                                                                                       Calibration Calibration Calibration
                 Signal Analyzer 40
 1       A                                 FSV40             R&S           101042      300004517       k       17.12.2018   16.12.2019
                        GHz
                  Synchron Power
 2       A                                 SPM-4             CTC              1        300005580       ev          -/-          -/-
                        Meter
                                      ST18/SMAm/SMAm/                     Batch no.
 3       A           RF-Cable                           Huber & Suhner                 400001309       ev          -/-          -/-
                                             36                            601494
 4       A       DC Power Supply          HMP2020       Rohde & Schwarz    102850      300005517      vlKI!    14.12.2017   13.12.2019




 © CTC advanced GmbH                                                                                                     Page 9 of 21


             Test report no.: 1-7492/18-01-02-A




7     Sequence of testing

7.1   Sequence of testing radiated spurious 9 kHz to 30 MHz
Setup
   • The equipment is set up to simulate normal operation mode as described in the user manual or defined
      by the manufacturer.
   • If the EUT is a tabletop system, it is placed on a table with 0.8 m height.
   • If the EUT is a floor standing device, it is placed directly on the turn table.
   • Auxiliary equipment and cables are positioned to simulate normal operation conditions as described in
      ANSI C 63.4.
   • The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
   • Measurement distance is 3 m (see ANSI C 63.4) – see test details.
   • EUT is set into operation.

Premeasurement*
   • The turntable rotates from 0° to 315° using 45° steps.
   • The antenna height is 1 m.
   • At each turntable position the analyzer sweeps with positive-peak detector to find the maximum of all
      emissions.

Final measurement
    • Identified emissions during the pre-measurement are maximized by the software by rotating the turntable
       from 0° to 360°.
    • Loop antenna is rotated about its vertical axis for maximum response at each azimuth about the EUT.
       (For certain applications, the loop antenna plane may also need to be positioned horizontally at the
       specified distance from the EUT)
    • The final measurement is done in the position (turntable and elevation) causing the highest emissions
       with quasi-peak (as described in ANSI C 63.4).
    • Final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the
       limit and limit will be recorded. A plot with the graph of the premeasurement and the limit is stored.

*)Note: The sequence will be repeated three times with different EUT orientations.




 © CTC advanced GmbH                                                                             Page 10 of 21


             Test report no.: 1-7492/18-01-02-A




7.2   Sequence of testing radiated spurious 30 MHz to 1 GHz
Setup
   • The equipment is set up to simulate normal operation mode as described in the user manual or defined
      by the manufacturer.
   • If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
   • If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
   • Auxiliary equipment and cables are positioned to simulate normal operation conditions as described in
      ANSI C 63.4.
   • The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
   • Measurement distance is 10 m or 3 m (see ANSI C 63.4) – see test details.
   • EUT is set into operation.

Premeasurement
   • The turntable rotates from 0° to 315° using 45° steps.
   • The antenna is polarized vertical and horizontal.
   • The antenna height changes from 1 m to 3 m.
   • At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
      find the maximum of all emissions.

Final measurement
    • The final measurement is performed for at least six highest peaks according to the requirements of the
       ANSI C63.4.
    • Based on antenna and turntable positions at which the peak values are measured the software maximize
       the peaks by changing turntable position ± 45° and antenna height between 1 and 4 m.
    • The final measurement is done with quasi-peak detector (as described in ANSI C 63.4).
    • Final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle,
       correction factor, margin to the limit and limit are recorded. A plot with the graph of the premeasurement
       with marked maximum final results and the limit is stored.




 © CTC advanced GmbH                                                                                Page 11 of 21


           Test report no.: 1-7492/18-01-02-A




8    Measurement uncertainty

                                       Measurement uncertainty
                          Test case                                      Uncertainty
Occupied bandwidth                                          ± used RBW
Field strength of the fundamental                           ± 3 dB
Field strength of the harmonics and spurious                ± 3 dB
Receiver spurious emissions and cabinet radiations          ± 3 dB
Conducted limits                                            ± 2.6 dB




© CTC advanced GmbH                                                                    Page 12 of 21


                Test report no.: 1-7492/18-01-02-A




9       Summary of measurement results

         ☒           No deviations from the technical specifications were ascertained
         ☐           There were deviations from the technical specifications ascertained
                     This test report is only a partial test report. The content and verdict of the performed test cases
         ☐           are listed below.

    TC Identifier                    Description                       Verdict           Date               Remark
                                     CFR Part 15
    RF-Testing                     RSS 210 Issue 9                    See table!     2019-08-13               -/-
                                   RSS Gen Issue 5

         Test
                                                Temperature      Power source
    specification           Test case                                               C     NC     NA    NP     Remark
                                                 conditions       conditions
        clause
       RSS Gen
     Issue 5(6.6)
                       Occupied bandwidth         Nominal           Nominal         ☒      ☐     ☐     ☐            -/-


                       Field strength of the
      § 15.209
                           fundamental
                                                  Nominal           Nominal         ☒      ☐     ☐     ☐            -/-


       § 15.209        Field strength of the
      RSS Gen             harmonics and           Nominal           Nominal         ☒      ☐     ☐     ☐            -/-
    Issue 5 (6.13)           spurious

                       Receiver spurious
      § 15.109        emissions and cabinet       Nominal           Nominal         ☐      ☐     ☒     ☐            -/-
                            radiations

                                                                                                                Car
      §15.107
      §15.207
                         Conducted limits         Nominal           Nominal         ☐      ☐     ☒     ☐       battery
                                                                                                              powered


Note: NA = Not applicable; NP = Not performed; C = Compliant; NC = Not compliant



10      Additional comments
Reference documents:                None

Special test descriptions:          None

Configuration descriptions:         None




 © CTC advanced GmbH                                                                                        Page 13 of 21


             Test report no.: 1-7492/18-01-02-A




11       Measurement results

11.1 Occupied bandwidth
Measurement:

The emission bandwidth (x dB) is defined as the frequency range between two points, one above and one
below the carrier frequency, at which the spectral density of the emission is attenuated x dB below the
maximum in-band spectral density of the modulated signal.

                                         Measurement parameters
 Detector:                                            Peak
 Resolution bandwidth:                                1 % – 5 % of the occupied bandwidth
 Video bandwidth:                                     ≥ 3x RBW
 Trace mode:                                          Max hold
 Analyser function:                                   99 % power function
 Used test setup:                                     See sub clause 6.3 A
 Measurement uncertainty:                             See sub clause 8



Limit:

                                                      IC
                                   for RSP-100 test report coversheet only



Result:

                                         99% emission bandwidth
                                               19.67 kHz




 © CTC advanced GmbH                                                                             Page 14 of 21


            Test report no.: 1-7492/18-01-02-A




Plot:

Plot 1: 99 % emission bandwidth




 © CTC advanced GmbH                             Page 15 of 21


             Test report no.: 1-7492/18-01-02-A




11.2 Field strength of the fundamental
Measurement:

The maximum detected field strength for the carrier signal.

                                                   Measurement parameters
 Detector:                                                      average / peak (worst case)
 Resolution bandwidth:                                          9 kHz
 Video bandwidth:                                               ≥ 3x RBW
 Trace mode:                                                    Max hold
 Used test setup                                                See sub clause 6.2 A
 Measurement uncertainty:                                       See sub clause 8



Limit:

                                                                   FCC & IC
      Frequency                                                                                                     Measurement distance
                                                              Field strength
        (MHz)                                                                                                              (m)
     0.009-0.490                  2400/F(kHz)* = 109.8 µV/m = 40.8 dBµV/m                                                  300
*F(kHz) = 21.845



Recalculation:

                                                   According to ANSI C63.10
                                                                                                                     Correction value
          Frequency                                                 Formula
                                                                                                                   (from 3 m to 300 m)
                                                                                              𝑑𝑑𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙
                                                 FSlimit = FSmax −40 log �                                     �
                                                                                            𝑑𝑑𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚

                                FSlimit         is the calculation of field strength at the limit distance,
          21.845 kHz                            expressed in dBµV/m                                                      -80 dB
                                FSmax           is the measured field strength, expressed in dBµV/m
                                dnear field     is the λ/2π distance
                                dmeasure        is the distance of the measurement point from EUT
                                dlimit          is the reference limit distance




Result:

                                              Field strength of the fundamental
 Frequency                                                                21.845 kHz
 Distance                                                   @3m                                                      @ 300 m
 Measured / calculated value
                                                               102.4 dBµV/m                                        22.4 dBµV/m
 (peak measurement)
 Measured / calculated value
                                                                97.0 dBµV/m                                        17.0 dBµV/m
 (average measurement)




 © CTC advanced GmbH                                                                                                              Page 16 of 21


              Test report no.: 1-7492/18-01-02-A




11.3 Field strength of the harmonics and spurious
Measurement:

The maximum detected field strength for the harmonics and spurious.

                                         Measurement parameters
                                                      Quasi peak / average or
 Detector:
                                                      peak (worst case – pre-scan)
                                                      F < 150 kHz: 200 Hz
 Resolution bandwidth:                                150 kHz < F < 30 MHz: 9 kHz
                                                      30 MHz < F < 1 GHz: 120 kHz
                                                      F < 150 kHz: 1 kHz
 Video bandwidth:                                     150 kHz < F < 30 MHz: 100 kHz
                                                      30 MHz < F < 1 GHz: 300 kHz
 Trace mode:                                          Max hold
                                                      9 kHz to 30 MHz: see sub clause 6.2 A
 Used test setup:
                                                      30 MHz to 1 GHz: see sub clause 6.1 A
 Measurement uncertainty:                             See sub clause 8



Limit:

                                                  FCC & IC
               Frequency                        Field strength                Measurement distance
                  (MHz)                           (dBµV/m)                           (m)
             0.009 – 0.490                       2400/F(kHz)                         300
             0.490 – 1.705                      24000/F(kHz)                          30
               1.705 – 30                     30 (29.5 dBµV/m)                        30
                 30 – 88                      100 (40 dBµV/m)                          3
                88 – 216                     150 (43.5 dBµV/m)                         3
               216 – 960                      200 (46 dBµV/m)                          3



Result:

                                            Detected emissions
          Frequency                                    Resolution bandwidth
                                    Detector                                    Detected value (dBµV/m)
            (MHz)                                              (kHz)
                                           See table below Plot 3.




 © CTC advanced GmbH                                                                          Page 17 of 21


                      Test report no.: 1-7492/18-01-02-A




Plots:

Plot 1: 9 kHz – 30 MHz, magnetic emissions, ANT 0°
         130
dBµV/m
         120

         110

         100

          90

          80

          70

          60

          50

          40

          30

          20

          10

           0
               9kHz                          100k                      1M   10M            30MHz
                                                           Frequency




Plot 2: 9 kHz – 30 MHz, magnetic emissions, ANT 90°
         130
dBµV/m
         120

         110

         100

          90

          80

          70

          60

          50

          40

          30

          20

          10

           0
               9kHz                          100k                      1M   10M            30MHz
                                                           Frequency




 © CTC advanced GmbH                                                              Page 18 of 21


                  Test report no.: 1-7492/18-01-02-A




Plot 3: 30 MHz – 1 GHz, vertical and horizontal polarisation



                                 60

                                 55

                                 50

                                 45                                                                                     FCC_10m_B

                                 40
               Level in dBµV/m




                                 35

                                 30

                                 25

                                 20

                                 15

                                 10

                                 5

                                 0
                                 30M           50   60      80 100M               200        300     400    500          800   1,05G
                                                                           Frequency in Hz



Final_Result
   Frequency                      QuasiPeak       Limit         Margin       Meas.      Bandwidth          Height   Pol        Azimuth     Corr.
     (MHz)                        (dBµV/m)      (dBµV/m)         (dB)        Time         (kHz)             (cm)                (deg)     (dB/m
                                                                             (ms)                                                           )
        31.883                         14.14             30.0      15.86       1000                120      103.0   V             226.0       13
        32.145                         15.74             30.0      14.26       1000                120       98.0   V             225.0       13
        56.697                         19.41             30.0      10.59       1000                120      100.0   V             -44.0       14
        63.069                         19.05             30.0      10.95       1000                120      100.0   V              45.0       12
        66.789                         24.87             30.0       5.13       1000                120      200.0   V             136.0       11
        70.606                         26.12             30.0       3.88       1000                120      244.0   V             135.0       11
        90.229                         22.71             33.5      10.79       1000                120      200.0   V              90.0       12




12    Observations
No observations except those reported with the single test cases have been made.




 © CTC advanced GmbH                                                                                                                Page 19 of 21


           Test report no.: 1-7492/18-01-02-A




Annex A         Glossary

         EUT    Equipment under test
         DUT    Device under test
         UUT    Unit under test
        GUE     GNSS User Equipment
        ETSI    European Telecommunications Standards Institute
          EN    European Standard
         FCC    Federal Communications Commission
      FCC ID    Company Identifier at FCC
           IC   Industry Canada
        PMN     Product marketing name
        HMN     Host marketing name
        HVIN    Hardware version identification number
        FVIN    Firmware version identification number
        EMC     Electromagnetic Compatibility
          HW    Hardware
          SW    Software
     Inv. No.   Inventory number
   S/N or SN    Serial number
            C   Compliant
          NC    Not compliant
          NA    Not applicable
          NP    Not performed
          PP    Positive peak
          QP    Quasi peak
        AVG     Average
          OC    Operating channel
        OCW     Operating channel bandwidth
        OBW     Occupied bandwidth
        OOB     Out of band
         DFS    Dynamic frequency selection
        CAC     Channel availability check
          OP    Occupancy period
        NOP     Non occupancy period
          DC    Duty cycle
         PER    Packet error rate
          CW    Clean wave
          MC    Modulated carrier
       WLAN     Wireless local area network
       RLAN     Radio local area network
       DSSS     Dynamic sequence spread spectrum
       OFDM     Orthogonal frequency division multiplexing
       FHSS     Frequency hopping spread spectrum
       GNSS     Global Navigation Satellite System
        C/N0    Carrier to noise-density ratio, expressed in dB-Hz



© CTC advanced GmbH                                                  Page 20 of 21


            Test report no.: 1-7492/18-01-02-A




Annex B        Document history

  Version                                Applied changes                                 Date of release

     -/-                                    Initial release                                2019-08-08

     A                  Measurement repeated with avg. detector (capter 11.2)              2019-08-13




Annex C        Accreditation Certificate

                       first page                                           last page




Note: The current certificate annex is published on the website (link see below) of the Accreditation
Body DAkkS or may be received by CTC advanced GmbH on request

https://www.dakks.de/as/ast/d/D-PL-12076-01-03.pdf

################################# END OF TEST REPORT ##################################




 © CTC advanced GmbH                                                                          Page 21 of 21



Document Created: 2019-08-13 13:11:45
Document Modified: 2019-08-13 13:11:45

© 2024 FCC.report