Test Report

FCC ID: IYZ335033

Test Report

Download: PDF
FCCID_1304542

  Test report no. 10006126                                     Page 1 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033




                                                              DAT-P-225/96

                                                 Test Report
                                        acc. to the relevant standard
                                   47 CFR Part 15 C – Intentional Radiators
                                          Measurement Procedure:
                                              ANSI C63.4-2003
                                                  relating to
                                              Marquardt GmbH
                                                    3350.33
                                                  Variants:
                                                    3350.32
                                                    3350.36




                                             Methods of Measurement of Radio-
                                              Noise Emissions from Low-Voltage
                                             Electrical and Electronic Equipment
                                                in the Range 9 kHz to 40 GHz




                                                                           DAT-P-225/96




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 2 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033


 Manufacturer’s details
 Manufacturer                                                          Marquardt GmbH
 Manufacturer‟s grantee code                                           IYZ
 Manufacturer‟s address                                                Schloß Straße 16
                                                                       D-78604 Rietheim-Weilheim
                                                                       Germany
                                                                       Phone: +49(0)7424 99 1867
                                                                       Fax: +49(0)7424 99 2122
                                                                       e-mail: bern.baer@marquardt.de
 Relevant standard used                                                47 CFR Part 15C - Intentional Radiators
                                                                       ANSI C63.4-2003



 Test report prepared by
 Technical engineer                                                    Ralf Trepper
                                                                       m.dudde hochfrequenz-technik (laboratory)
                                                                       Rottland 5a
                                                                       51429 Bergisch Gladbach
                                                                       Germany
                                                                       Phone: +49 (0) 2207 96 89-0
                                                                       Fax: +49 (0) 2207 96 89-20
                                                                       E-mail: m.duddelabor@dudde.com




 Equipment Under Test (EUT)
 Equipment category                                                    Inductive transmitter
 Trade name                                                            Marquardt
 Type designation                                                      3350.33
 Serial no.                                                            ---
 Variants                                                              3350.32
                                                                       3350.36




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 3 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033


1. Test result summary

                           Report       Requirements
CFR Section                                                                                                              Test result
                           Chapter      Headline
15.203                      11.1        Antenna requirement                                                       Pass      Fail       N.t.
15.205 (a)                  11.2        Restricted bands of operation
15.209                      11.3        Radiated emission limits, general requirements                            Pass      Fail       N.t.
                                        (LF transmitter part of the EUT)

The equipment meets the requirements                                                                                Yes             No



Signature
Technician              ……………………………
                           Ralf Trepper


Signature
Manager                ……………………………..
                         Manfried Dudde




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                                    Page 4 of 21


   EUT: 3350.33                                                                                                                    Date of issue: 2010-06-10
   FCC ID: IYZ335033


                                                                        Table of contents

  1. Test result summary .......................................................................................................................................... 3
  2. Test laboratory .................................................................................................................................................. 5
  3. Introduction ...................................................................................................................................................... 5
  4. Product ............................................................................................................................................................. 6
  5. Test schedule .................................................................................................................................................... 6
  6. Product and measurement documentation ......................................................................................................... 7
  7. Observations and comments ............................................................................................................................. 7
  8. Summary........................................................................................................................................................... 7
  9. Conclusions ...................................................................................................................................................... 8
  10. Operational description .................................................................................................................................. 9
  11.1 Antenna requirement .................................................................................................................................... 10
       11.1.1 Regulation ........................................................................................................................................... 10
       11.1.2 Result .................................................................................................................................................. 10
  11.2 Restricted bands of operation ...................................................................................................................... 11
       11.2.1 Regulation ........................................................................................................................................... 11
       11.2.2 Result .................................................................................................................................................. 13
  11.3 Radiated emission limits, general requirements .......................................................................................... 14
       11.3.1 Regulation ........................................................................................................................................... 14
       11.3.2 Test equipment ................................................................................................................................... 15
       11.3.3 Test procedure .................................................................................................................................... 16
       11.3.4 Calculation of the field strength ......................................................................................................... 17
       11.3.5 Test result ........................................................................................................................................... 18
  12. Additional information to the test report ....................................................................................................... 20




State: 2008-04-21                                                                                                                                             Vers. no.: 1. 08

            m. dudde hochfrequenz - technik            Rottland 5a      D-51429 Bergisch Gladbach            Tel. +49 2207-96890        Fax +49 2207 968920


  Test report no. 10006126                                     Page 5 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

2. Test laboratory
Company name                           : m.dudde hochfrequenz-technik
Street                                 : Rottland 5a
City                                   : 51429 Bergisch Gladbach
Country                                : Germany
Laboratory                             : FCC Registration Number: 699717
                                        This site has been fully described in a report submitted to the FCC, and
                                        renewed with letter dated July 12, 2005, Registration Number 699717.
Phone                                  : +49-2207-9689-0
Fax                                    : +49-2207-9689-20
E-Mail                                 : manfred.dudde@t-online.de
Web                                    : http://www.dudde.com




3. Introduction
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the
report requires the prior written approval of m. dudde hochfrequenz - technik.

This report contains the result of tests performed by m. dudde hochfrequenz - technik for the purpose of a type
approval. The order for carrying out these tests has been placed by:

Manufacturer
Company name                           : Marquardt GmbH
Address                                : Schloß Straße 16
Postcode                               : 78604
City/town                              : Rietheim Weilheim
Country                                : Germany
Telephone                              : +49(0)7424 99 1867
Fax                                    : +49(0)7424 99 2122
E-Mail                                 : bernd.baer@marquardt.de
Date of order                          : 2009-10-13
References                             : Mr. Bernd Bär




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 6 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

4. Product
Samples of the following apparatus were submitted for testing:


Type of equipment                                : LF transmitter (dedicated antenna)
Trademark                                        : Marquardt
Type designation                                 : 3350.33
Variants                                         : 3350.32, 3350.36
Hardware version                                 : 3350.33, 3350.32, 3350.36
Serial number                                    : ---
Software release                                 : ---
Power used                                       : 13.20 VDC
Frequency used                                   : 315.00 MHz / 21.845 kHz
Generated or used frequencies                    : 8.0 MHz (Crystal) / 12.73193 MHz (Crystal)
                                                   315.00 MHz (Carrier, RF), 21.845 kHz (Carrier, LF)
ITU emission class                               : 31K5G1D (LF transmitter)
FCC ID                                           : IYZ335033




5. Test schedule
The tests were carried out in accordance with the specifications detailed in chapter 7 “Summary“ of this report at:

- m. dudde hochfrequenz - technik, D-51429 Bergisch Gladbach

The test sample was received on:

- 2009-10-13

The tests were carried out in the following period of time:

- 2009-12-03 - 2010-02-11




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 7 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033


6. Product and measurement documentation
For issuing this report the following product documentation was used and the following annexes were created:

   Description                                                                             Date                   Identifications
   External photographs of the Equipment Under Test                                        2010-05-03             Annex no. 1
   Internal photographs of the Equipment Under Test                                        2010-05-03             Annex no. 2
   Occupied bandwidth plot                                                                 2010-05-03             Annex no. 3
   FCC ID label sample                                                                     2010-05-03             Annex no. 4
   Functional description / User Manual                                                    2010-05-03             Annex no. 5
   Test setup photos                                                                       2010-05-03             Annex no. 6
   Block diagram                                                                           2010-05-03             Annex no. 7
   Schematics                                                                              2010-05-03             Annex no. 8
   Parts list                                                                              2010-05-03             Annex no. 9
   Operational description                                                                 2010-05-03             Annex no. 10
   Periodic operation characteristic                                                       2010-05-03             Annex No. 11

The above mentioned documentation will be filed at m. dudde hochfrequenz - technik for a period of
10 years following the issue of this test report.




7. Observations and comments




8. Summary
The product is intended for the use in the following areas of application:

Radio-Noise Emissions from Low- Voltage Electrical and Electronic Equipment
in the frequency range of 9 kHz to 40 GHz

The samples were tested according to the following specification:

47 CFR Part 15 – Intentional Radiators, ANSI C63.4-2003




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 8 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

9. Conclusions

Samples of the apparatus were found to CONFORM WITH the specifications stated in chapter 8
"Summary" of this report.

In the opinion of m. dudde hochfrequenz - technik, the samples satisfied all applicable requirements relating to the
network interface types specified in chapter 8.

The results of the type tests as stated in this report are exclusively applicable to the product item as identified in
this report. m. dudde hochfrequenz - technik does not accept any responsibility for the results stated in this report,
with respect to the properties of product items not involved in these tests.

This report consists of a main module, modules with test results and annexes listed in chapter 6. All pages have
been numbered consecutively and bear the m. dudde hochfrequenz - technik logo, the report number and sub-
numbers.

The total number of pages in this report is 21.


Technical inspector:


Date            : 2010-06-10

Name            : Ralf Trepper

Signature       :
                    …………………………………


Technical responsibility for area of testing:


Date            : 2010-06-10

Name            : Manfried Dudde

Signature       :
                    …………………………………..




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 9 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

10. Operational description
          10.1 EUT details


Car lock unlock device



          10.2 EUT configuration

The Transceivers 3350.33, 3350.32 and 3350.36 operated in the continuous transmitting mode after setting a dip
switch for test mode configuration.



          10.3 EUT measurement description

The Transceivers 3350.33, 3350.32 and 3350.36 was tested in a typical fashion. During preliminary emission
tests the Transceivers 3350.33, 3350.32 and 3350.36 was operated in the continuous transmitting mode for
worst case emission mode investigation. Therefore, the final qualification testing was completed with
Transceiver 3350.33 operated in continuous modes.
All tests were performed with the applicant‟s typical voltage: 13.2 V DC
In order to establish the maximum radiation, firstly, there have been viewed all orthogonal adjustments of the
test samples, secondly the test ample have been rotated at all adjustments around the own axis between 0° and
360°, and thirdly, the antenna polarization between horizontal and vertical had been varied.




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 10 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

11.1 Antenna requirement

11.1.1 Regulation

An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique
coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section.
The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a
standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current
devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further,
this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter
protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with
Section 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring
that the proper antenna is employed so that the limits in this Part are not exceeded.


11.1.2 Result

    The equipment meets the requirements                                                                       Yes       No         N.t.

    Further test results are attached                                                      Yes               No      Annex no. 2

The device is placed beneath the car interior lining.

The device is not available on the open market (OEM Only)
The device has to be installed by a trained person.




n.a.*    See page no. 40




State: 2008-04-21                                                                                                             Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890    Fax +49 2207 968920


    Test report no. 10006126                                   Page 11 of 21


     EUT: 3350.33                                                                                       Date of issue: 2010-06-10
     FCC ID: IYZ335033

11.2 Restricted bands of operation

(LF Transmitter, 21.845 kHz)

11.2.1 Regulation

(a) Except as shown in paragraph (d) of this section, only spurious emissions are permitted in any of the frequency
bands listed below:


                 MHz                            MHz                               MHz                               GHz
            0.090 - 0.110                  16.42 - 16.423                     399.9 - 410                        4.5 - 5.15
            1
              0.495 - 0.505             16.69475 - 16.69525                     608 - 614                       5.35 - 5.46
           2.1735 - 2.1905              16.80425 - 16.80475                    960 - 1240                       7.25 - 7.75
            4.125 - 4.128                   25.5 - 25.67                      1300 - 1427                       8.025 - 8.5
          4.17725 - 4.17775                 37.5 - 38.25                     1435 - 1626.5                        9.0 - 9.2
          4.20725 - 4.20775                   73 - 74.6                     1645.5 - 1646.5                       9.3 - 9.5
            6.215 - 6.218                    74.8 - 75.2                      1660 - 1710                       10.6 - 12.7
          6.26775 - 6.26825                 108 - 121.94                    1718.8 - 1722.2                    13.25 - 13.4
          6.31175 - 6.31225                   123 - 138                       2200 - 2300                      14.47 - 14.5
            8.291 - 8.294                  149.9 - 150.05                     2310 - 2390                      15.35 - 16.2
            8.362 - 8.366              156.52475 - 156.52525                 2483.5 - 2500                      17.7 - 21.4
          8.37625 - 8.38675                 156.7 - 156.9                     2690 - 2900                     22.01 - 23.12
          8.41425 - 8.41475              162.0125 - 167.17                    3260 - 3267                       23.6 - 24.0
            12.29 - 12.293                 167.72 - 173.2                     3332 - 3339                       31.2 - 31.8
         12.51975 - 12.52025                  240 - 285                      3345.8 - 3358                     36.43 - 36.5
         12.57675 - 12.57725                 322 - 335.4                      3600 - 4400                            (2)
            13.36 - 13.41


1
    Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
2
    Above 38.6


(b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing within these frequency
bands shall not exceed the limits shown in Section 15.209. At frequencies equal to or less than 1000 MHz,
compliance with the limits in Section 15.209 shall be demonstrated using measurement instrumentation employing
a CISPR quasi-peak detector. Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be
demonstrated based on the average value of the measured emissions. The provisions in Section 15.35 apply to
these measurements.

(c) Except as provided in paragraphs (d) and (e), regardless of the field strength limits specified elsewhere in this
Subpart, the provisions of this Section apply to emissions from any intentional radiator.




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 12 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

(d) The following devices are exempt from the requirements of this Section:

          (1) Swept frequency field disturbance sensors operating between 1.705 and 37 MHz provided their
          emissions only sweep through the bands listed in paragraph (a), the sweep is never stopped with the
          fundamental emission within the bands listed in paragraph (a), and the fundamental emission is outside of
          the bands listed in paragraph (a) more than 99% of the time the device is actively transmitting, without
          compensation for duty cycle.

          (2) Transmitters used to detect buried electronic markers at 101.4 kHz which are employed by telephone
          companies.

          (3) Cable locating equipment operated pursuant to Section 15.213.

          (4) Any equipment operated under the provisions of § 15.253, § 15.255 or § 15.257 of this part.

          (5) Biomedical telemetry devices operating under the provisions of Section 15.242 of this part are not
          subject to the restricted band 608-614 MHz but are subject to compliance within the other restricted bands.

          (6) Transmitters operating under the provisions of Subpart D or F of this part.

          (7) Devices operated pursuant to § 15.225 are exempt from complying with this section for the 13.36-
          13.41 MHz band only.

          (8) Devices operated in the 24.075-24.175 GHz band under § 15.245 are exempt from complying with the
          requirements of this section for the 48.15-48.35 GHz and 72.225-72.525 GHz bands only, and shall not
          exceed the limits specified in § 15.245(b).

          (9) Devices operated in the 24.0-24.25 GHz band under § 15.249 are exempt from complying with the
          requirements of this section for the 48.0-48.5 GHz and 72.0-72.75 GHz bands only, and shall not exceed
          the limits specified in § 15.249(a).

(e) Harmonic emissions appearing in the restricted bands above 17.7 GHz from field disturbance sensors operating
under the provisions of Section 15.245 shall not exceed the limits specified in Section 15.245(b).


(b) Except as provided in paragraphs (d) and (e), the field strength of emissions appearing within these frequency
bands shall not exceed the limits shown in Section 15.209. At frequencies equal to or less than 1000 MHz,
compliance with the limits in Section 15.209 shall be demonstrated using measurement instrumentation employing
a CISPR quasi-peak detector. Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be
demonstrated based on the average value of the measured emissions. The provisions in Section 15.35 apply to
these measurements.

(c) Except as provided in paragraphs (d) and (e), regardless of the field strength limits specified elsewhere in this
Subpart, the provisions of this Section apply to emissions from any intentional radiator. (d) The following devices
are exempt from the requirements of this Section:

          (1) Swept frequency field disturbance sensors operating between 1.705 and 37 MHz provided their
          emissions only sweep through the bands listed in paragraph (a), the sweep is never stopped with the
          fundamental emission within the bands listed in paragraph (a), and the fundamental emission is outside of
          the bands listed in paragraph (a) more than 99% of the time the device is actively transmitting, without
          compensation for duty cycle.
State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 13 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

          (2) Transmitters used to detect buried electronic markers at 101.4 kHz which are employed by telephone
          companies.

          (3) Cable locating equipment operated pursuant to Section 15.213.

          (4) Any equipment operated under the provisions of § 15.253, § 15.255 or § 15.257 of this part.

          (5) Biomedical telemetry devices operating under the provisions of Section 15.242 of this part are not
          subject to the restricted band 608-614 MHz but are subject to compliance within the other restricted bands.

          (6) Transmitters operating under the provisions of Subpart D or F of this part.

          (7) Devices operated pursuant to § 15.225 are exempt from complying with this section for the 13.36-
          13.41 MHz band only.

          (8) Devices operated in the 24.075-24.175 GHz band under § 15.245 are exempt from complying with the
          requirements of this section for the 48.15-48.35 GHz and 72.225-72.525 GHz bands only, and shall not
          exceed the limits specified in § 15.245(b).

          (9) Devices operated in the 24.0-24.25 GHz band under § 15.249 are exempt from 83 complying with the
          requirements of this section for the 48.0-48.5 GHz and 72.0-72.75 GHz bands only, and shall not exceed
          the limits specified in § 15.249(a).

(e) Harmonic emissions appearing in the restricted bands above 17.7 GHz from field disturbance sensors operating
under the provisions of Section 15.245 shall not exceed the limits specified in Section 15.245(b).


11.2.2 Result

    The equipment meets the requirements                                                                       Yes       No         N.t.

    Further test results are attached                                                      Yes               No      Page no. 19-20




State: 2008-04-21                                                                                                             Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890    Fax +49 2207 968920


  Test report no. 10006126                                     Page 14 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

11.3 Radiated emission limits, general requirements
(LF Transmitter, 21.845 kHz)

11.3.1 Regulation

(a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not exceed the
field strength levels specified in the following table:

    Frequency                                Field Strength                            Measurement distance
    (MHz)                                    (microvolts/meter)                        (meters)

    0.009-0.490                              2400/F(kHz)                               300
    0.490-1.705                              24000/F(kHz)                              30
    1.705-30.0                               30                                        30
    30-88                                    100                                       3
    88-216                                   150                                       3
    216-960                                  200                                       3
    Above 960                                500                                       3

(b) In the emission table above, the tighter limit applies at the band edges.

(c) The level of any unwanted emissions from an intentional radiator operating under these general provisions shall
not exceed the level of the fundamental emission. For intentional radiators which operate under the provisions of
other sections within this part and which are required to reduce their unwanted emissions to the limits specified in
this table, the limits in this table are based on the frequency of the unwanted emission and not the fundamental
frequency. However, the level of any unwanted emissions shall not exceed the level of the fundamental frequency.

(d) The emission limits shown in the above table are based on measurements employing a CISPR quasi peak
detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission limits in
these three bands are based on measurements employing an average detector.

(e) The provisions in §§ 15.31, 15.33, and 15.35 for measuring emissions at distances other than the distances
specified in the above table, determining the frequency range over which radiated emissions are to be measured,
and limiting peak emissions apply to all devices operated under this part.

(f) In accordance with Section 15.33(a), in some cases the emissions from an intentional radiator must be measured
to beyond the tenth harmonic of the highest fundamental frequency designed to be emitted by the intentional
radiator because of the incorporation of a digital device. lf measurements above the tenth harmonic are so required,
the radiated emissions above the tenth harmonic shall comply with the general radiated emission limits applicable
to the incorporated digital device, as shown in Section 15.109 and as based on the frequency of the emission being
measured, or, except for emissions contained in the restricted frequency bands shown in Section 15.205, the limit
on spurious emissions specified for the intentional radiator, whichever is the higher limit. Emissions which must
be measured above the tenth harmonic of the highest fundamental frequency designed to be emitted by the
intentional radiator and which fall within the restricted bands shall comply with the general radiated emission
limits in Section 15.109 that are applicable to the incorporated digital device.




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                       Page 15 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

11.3.2 Test equipment


    Type                     Manufacturer/                 Serial no.            Last calibration             Next calibration
                             Model no.
    Receiver                 Rohde & Schwarz               100.117               2008/10                      2010/10
                             Spectrum Analyzer
    (9 kHz –18.0 GHz)        FSL 18 (171a)
    Pre-amplifier            Hewlett Packard               1726A00705            2010/02                      2012/02
    (100kHz - 1.3GHz)        8447 E (166a)
    Pre-amplifier            Narda                         ---                   2010/02                      2012/02
    (1GHz - 18GHz)           --- (345)
    Magnetic loop            Schwarzbeck                   ---                   2008/09                      2010/09
    antenna                  FMZB 1516 (23)
    (9 kHz - 30 MHz)
    Bilog antenna            Schwarzbeck                   ---                   2007/02                      2013/02
    (30- 1000 MHz)           VULP 9168 (406)
    Bilog antenna            Schwarzbeck                   ---                   2007/02                      2013/02
    (1- 18 GHz)              VULP 9168 (408)
    Horn antenna             Schwarzbeck                   236                   2008/01                      2013/01
    (0.86-8.5 GHz)           BBHA 9120 A (284)
    Horn antenna             Schwarzbeck                   305                   2008/01                      2013/01
    (2.0-14.0 GHz)           BBHA 9120 C (169)
    RF- cable                Kabelmetal 18m [N]            K1                    2010/01                      2011/01
    RF- cable                Aircell 0.5m [BNC]            K40                   2010/01                      2011/01
    RF- cable                Aircell 1m [BNC/N]            K56                   2010/01                      2011/01
    RF- cable                Sucoflex 106 Suhner           K74                   2010/01                      2011/01
                             6,4m [N]
    RF- cable                Sucoflex 106 Suhner           K75                   2010/01                      2011/01
                             6,4m [N]




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 16 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

11.3.3 Test procedure

The EUT and this peripheral (when additional equipment exists) are placed on a turn table which is 0.8 m above the
ground. The turn table would be allowed to rotate 360 degrees to determine the position of the maximum emission
level. The test distance between the EUT and the receiving antenna are 3m. To find the maximum emission, the
polarization of the receiving antenna is changed in horizontal and vertical polarization; the position of the EUT was
changed in different orthogonal determinations.

ANSI C63.4: 2003 Section 8 “Radiated Emissions Testing”

Measurement procedures for electric field radiated emissions above 1 GHz are covered in Clause 8 of ANSI
C63.4-2003. The C63.4-2003 measurement procedure consists of both an exploratory test and a final measurement.
The exploratory test is critical to determine the frequency of all significant emissions. For each mode of operation
required to be tested, the frequency spectrum is monitored. Variations in antenna height, antenna orientation,
antenna polarization, EUT azimuth, and cable or wire placement is explored to produce the emission that has the
highest amplitude relative to the limit.

The final measurements are made based on the findings in the exploratory testing. When making exploratory and
final measurements it is necessary to maximize the measured radiated emission. Subclause 8.3.1.2 of C63.4-2003
states that the measurement is to be made “while keeping the antenna in the „cone of radiation‟ from that area and
pointed at the area both in azimuth and elevation, with polarization oriented for maximum response.” We consider
the “cone of radiation” to be the 3 dB beamwidth of the measurement antenna.

While the “bore-sighting” technique is not explicitly mentioned in C63.4-2003, it is a useful technique for
measurements using a directional antenna, such as a double-ridged waveguide antenna. Several precautions must
be observed, including: knowledge of the beamwidth of the antenna and the resulting illumination area relative to
the size of the EUT, estimation for source of the emission and general location within larger EUTS, measuring
system sensitivity, etc.

C63.4-2003 requires that the measurement antenna is kept pointed at the source of the emission both in azimuth
and elevation, with the polarization of the antenna oriented for maximum response. That means that if the
directional radiation pattern of the EUT results in a maximum emission at an upwards angle from the EUT, when a
directional antenna is used to make the measurement it will be necessary for it to be pointed towards the source of
the emission within the EUT. This can be done by either pointing the antenna at an angle towards the source of the
emission, or by rotating the EUT, in both height and polarization, to maximize the measured emission. The
emission must be kept within the illumination area of the 3 dB beamwidth of the antenna so that the maximum
emission from the EUT is measured.




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 17 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033


 Radiated emissions test characteristics
 Frequency range                                                    30 MHz - 4,000 MHz
 Test distance                                                      3 m*
 Test instrumentation resolution bandwidth                          120 kHz (30 MHz - 1,000 MHz)
                                                                    1 MHz (1000 MHz - 4,000 MHz)
 Receive antenna scan height                                        1m-4m
 Receive antenna polarization                                       Vertical/horizontal

* According to Section 15.31 (f) (1): At frequencies at or above 30 MHz, measurements may be performed at a
distance other than what is specified provided: measurements are not made in the near field except where it can be
shown that near field measurements are appropriate due to the characteristics of the device; and it can be
demonstrated that the signal levels needed to be measured at the distance employed can be detected by the
measurement equipment. When performing measurements at a distance other than that specified, the results shall
be extrapolated to the specified distance using an extrapolation factor of 20dB/decade (inverse linear-distance for
field strength measurements; inverse-linear-distance-squared for power density measurements).


11.3.4 Calculation of the field strength

The field strength is calculated by the following calculation:

Corrected Level = Receiver Level + Correction Factor (without the use of a pre-amplifier)

Corrected Level = Receiver Level + Correction Factor – Pre-amplifier (with the use of a pre-amplifier)

Receiver Level               : Receiver reading without correction factors
Correction Factor            : Antenna factor + cable loss

For example:
The receiver reading is 32.7 dBµV. The antenna factor for the measured frequency is +2.5 dB (1/m) and the cable
factor for the measured frequency is 0.71 dB, giving a field strength of 35.91dBµV/m.
The 35.91dBµV/m value can be mathematically converted to its corresponding level in µV/m.

Level in µV/m = Common Antilogarithm (35.91/20) = 39.8

For test distance other than what is specified, but fulfilling the requirements of Section 15.31 (f) (1) the field strength
is calculated by adding additionally an extrapolation factor of 20 dB/decade (inverse linear distance for field strength
measurements).




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                         Page 18 of 21


   EUT: 3350.33                                                                                             Date of issue: 2010-06-10
   FCC ID: IYZ335033

11.3.5 Test result

                TRANSMITTER SPURIOUS RADIATION BELOW 30 MHz (Section 15.205, 15.209)
                                                                                                                                      Polarisation
   f                Bandwidth      Noted       Test        Correction    Distance      Level            Limit         Margin
                                                                                                                                         EUT
 (MHz)                (kHz)       receiver   distance        factor      extrapol.   corrected
                                                                                                                                            /
                      Type          level                                 factor                                                        antenna
                    of detector                   m           dB           dB        dBµV/m            dBµV/m           dB             orientation
                                  dBµV
 0.021845      AV/0.2kHz           67.0      10                         -59.1                     AV40.8- @ 300                      V, H/0-360°
                                                             20.2                      28.3                             12.5
 0.043690      AV/0.2kHz           26.5      10              20.2       -59.1                     AV34.8- @ 300                      V, H/0-360°
                                                                                      -12.4                             47.2
 0.065535      AV/0.2kHz           30.0      10              20.2       -59.1                     AV31.3- @ 300                      V, H/0-360°
                                                                                       -8.9                             40.2
 0.087380      AV/0.2kHz           13.5      10              20.2       -59.1                     AV28.8- @ 300                      V, H/0-360°
                                                                                      -25.4                             54.2
 0.109225      QPK/0.2kHz          20.0      10              20.2       -59.1                     AV26.8- @ 300                      V, H/0-360°
                                                                                      -18.9                             45.7
 0.131070      AV/0.2kHz           15.5      10              20.2       -59.1                     AV25.2- @ 300                      V, H/0-360°
                                                                                      -23.4                             48.6
 0.152915      AV/0.2kHz          ≤ 4.0      10              20.2       -59.1                     AV23.9- @ 300
                                                                                      -34.9                             58.8         V, H/0-360°
 0.174760      AV/0.2kHz          ≤ 4.0      10              20.2       -59.1                     AV22.7- @ 300
                                                                                      -34.9                             57.6         V, H/0-360°
 0.196605      AV/0.2kHz          ≤ 4.0      10              20.2       -59.1                     AV21.7- @ 300
                                                                                      -34.9                             56.6         V, H/0-360°
 0.218450      AV/0.2kHz          ≤ 4.0      10              20.2       -59.1                     AV20.8- @ 300
                                                                                      -34.9                             55.7         V, H/0-360°

                     All other emissions up to 30 MHz are lower than the noise level of the measuring equipment!

   Measurement uncertainty                                                                    4 dB

Remark: *1 Noise level of the measuring instrument ≤ 4.0dBµV @ 10m distance (0.009 MHz –30 MHz)
Remark: * Peak Limit according to Section 15.35 (b).

    The equipment meets the requirements                                                                          Yes          No       N.t.

    Further test results are attached                                                            Yes            No      Page no.




State: 2008-04-21                                                                                                                   Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a    D-51429 Bergisch Gladbach    Tel. +49 2207-96890     Fax +49 2207 968920


    Test report no. 10006126                                            Page 19 of 21


     EUT: 3350.33                                                                                                 Date of issue: 2010-06-10
     FCC ID: IYZ335033



                  TRANSMITTER SPURIOUS RADIATION ABOVE 30 MHz (Section 15.205, 15.209)
                                                                                       AV                                             Polaris.       Antenna
    f          Bandwidth       Noted       Test       Correction        Distance                   Level       Limit        Margin
                                                                                    Correction                                         EUT            height
  (MHz)          (kHz)        receiver   distance       factor          extrapol.                corrected
                                                                                      factor                                             /
                  Type         level                                    factor                                                        antenna
               of detector    dBµV         m             dB                dB                    dBµV/m      dBµV/m         dBµV/m
                                                                                       dB                                                              cm

 30.0000        100, AV        ≤ 3.5        3           -2.60               0           0          0.90       40.00          39.10    H,V/H,V        100-400

 88.0000        100, AV        ≤ 3.5        3           -10.80              0           0          -7.30      40.00          47.30    H,V/H,V        100-400

 216.0000       100, AV        ≤ 3.5        3           -10.30              0           0          -6.80      43.50          50.30    H,V/H,V        100-400

 960.0000       100, AV        ≤ 3.5        3            8.50               0           0          12.00      43.50          31.50    H,V/H,V        100-400

1700.0000       1000, AV       ≤ 4.5        3            3.80               0           0          8.30       54.00          45.70    H,V/H,V        100-400

2250.0000       1000, AV       ≤ 10         3            8.00               0           0          18.00      54.00          36.00    H,V/H,V        100-400

4000.0000       1000, AV       ≤ 10         3          8.40*
                                                                6           0           0          18.40      54.00          35.60    H,V/H,V        100-400

5000.0000       1000, AV       ≤ 10         3          9.10*
                                                                6           0           0          19.40      54.00          34.60    H,V/H,V        100-400

7500.0000       1000, AV       ≤ 14         3          12.9* 0
                                                               6            0           0          26.90      54.00          27.10    H,V/H,V        100-400

8300.0000       1000, AV       ≤ 14         3          14.80*
                                                                   6        0           0          28.80      54.00          25.20    H,V/H,V        100-400

9400.0000       1000, AV       ≤ 14         3          16.00*
                                                                   6        0           0          30.00      54.00          24.00    H,V/H,V        100-400

11000.0000      1000, AV       ≤ 14         3          18.25*
                                                                   6        0           0          32.25      54.00          21.75    H,V/H,V        100-400

                         All emissions above 30 MHz are lower than the noise level of the measuring equipment!

 Measurement uncertainty                                                                         4 dB
                                                Bandwidth = the measuring receiver bandwidth

  Remark: *1 noise floor noise level of the measuring instrument ≤ 3.5dBµV @ 3m distance (30 – 1,000 MHz)
  Remark: *2 noise floor noise level of the measuring instrument ≤ 4.5dBµV @ 3m distance (1,000 – 2,000 MHz)
  Remark: *3 noise floor noise level of the measuring instrument ≤ 10dBµV @ 3m distance (2,000 – 5,500 MHz)
  Remark: *4 noise floor noise level of the measuring instrument ≤ 14dBµV @ 3m distance (5,500 – 14,500 MHz)
  Remark: *5 for using a pre-amplifier in the range between 100 kHz and 1,000 MHz
  Remark: *6 for using a pre-amplifier in the range between 1.0 GHz and 18.0 GHz

      The equipment meets the requirements                                                                               Yes         No       N.t.

      Further test results are attached                                                              Yes               No       Page no.




  State: 2008-04-21                                                                                                                       Vers. no.: 1. 08

             m. dudde hochfrequenz - technik     Rottland 5a        D-51429 Bergisch Gladbach    Tel. +49 2207-96890    Fax +49 2207 968920


  Test report no. 10006126                                     Page 20 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033

12. Additional information to the test report


                                                               Remarks
N.t.1                                  Not tested, because the antenna is part of the PCB

N.t.2                                  Not tested, because the EUT is directly battery powered

N.t.3                                  Not tested, because not applicable for this type of equipment

N.t.4                                  Not tested, because not ordered




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920


  Test report no. 10006126                                     Page 21 of 21


   EUT: 3350.33                                                                                         Date of issue: 2010-06-10
   FCC ID: IYZ335033




                                                     End of test report




State: 2008-04-21                                                                                                            Vers. no.: 1. 08

           m. dudde hochfrequenz - technik   Rottland 5a   D-51429 Bergisch Gladbach   Tel. +49 2207-96890   Fax +49 2207 968920



Document Created: 2010-06-10 17:05:32
Document Modified: 2010-06-10 17:05:32

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC