RF Exposure Info

FCC ID: IYZ-AK01

RF Exposure Info

Download: PDF
FCCID_4014571

                                                                                                                         D-PL-12076-01-03


      BNetzA-CAB-02/21-102




                               SAR Test exclusion documentation
                             according to FCC KDB 447498, RSS-102


                  Report identification number: 1-5579/17-01-03 Exclusion FCC_IC




 Product: AK01

 contains the module with the following certification numbers
 FCC ID                                                             IYZ-AK01
 IC number                                                          2701A-AK01
 HVIN (Hardware Version Identification Number)                      AK01
 PMN (Product Marketing Name)                                       AK01
 FVIN (Firmware Version Identification Number)                      -/-
 HMN (Host Marketing Name)                                          -/-




This report is electronically signed and valid without handwriting signature. For verification of the electronic signatures, the
public keys can be requested at the testing laboratory.


                                                                  Document authorized:
                                                                                                  cn=Alexander Hnatovskiy, o=CTC advanced
                                                                                                  GmbH, ou=HNA-161129,
                                                                                                  email=Alexander.Hnatovskiy@ctcadvanced.co
                                                                                                  m, c=DE
                                                                                                  2018.08.29 10:48:05 +02'00'

                                                                  Alexander Hnatovskiy
                                                                  Lab Manager
                                                                  Radio Communications & EMC


                                          Test report no.: 1-5579/17-01-03


EUT technologies:

     Technologies:                 Max. rated power: (AVG)                    Max. gain:                  Min. pathloss:
       Proprietary
                                   Declared max: -14.0 dBm                      <0 dBi                0 dB (if applicable)
     260 to 470MHz

Note: Declared max taken from customer info: AK01 technical Description 2014-05-23
      (measured maximum EIRP: -17.1 dBm, less than declared value)



SAR test exclusion according to KDB447498 (General RF Exposure Guidance v06)

Equation from Chapter 4.3.1: Standalone SAR test exclusion considerations page 11 and ff.

(1) Standalone SAR test exclusion for 100 MHz to 6 GHz at test separation distances ≤ 50mm

        ( Threshold1-g;10-g ) × dseperation / f 0.5

        where

        Threshold1-g;10-g is 3 for 1-g; 7.5 for 10-g
        dseperation       is the min. test separation distance; 5mm is used if the distance is less
        f                 is the RF channel transmit frequency

The table below gives the calculated maximal power that could be used for source based time averaged
conducted or radiated power, adjusted for tune up tolerance. If this is at or below the calculated value the DUT is
exempted from SAR evaluation.

  frequency       dseparation                         Powerlimit          Pmax-declared
                                  Threshold1-g                                                Exclusion
     [MHz]          [mm]                                [mW]           [dBm]         [mW]
    260.00            5                 3               29.42          -14.00         0.04      yes
    433.00            5                 3               22.80          -14.00         0.04      yes
    460.00            5                 3               22.12          -14.00         0.04      yes




SAR test exclusion according to RSS-102 Issue 5 Section 2.5.1/Table 1

The table below gives the calculated maximal power that could be used for source based time averaged
conducted or radiated power, adjusted for tune up tolerance. If this is at or below the calculated value the DUT is
exempted from SAR evaluation.

 frequency        dseparation                          Powerlimit           Pmax-declared
                                  tissue volume                                                 Exclusion
    [MHz]           [mm]                                 [mW]           [dBm]         [mW]
   260.00             5                 1g                4.00          -14.00         0.04        yes
   433.00             5                 1g                4.00          -14.00         0.04        yes
   460.00             5                 1g                4.00          -14.00         0.04        yes




© CTC advanced GmbH                                      Page 2 of 2



Document Created: 2018-08-29 10:48:05
Document Modified: 2018-08-29 10:48:05

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC