Horn Calibration Report

FCC ID: IYLRJ596

Test Report

Download: PDF
FCCID_687806

E06-000189

Additional information for item 7


1-18 GHz antenna last calibrated on 12/96

18-40 GHz last calibrated on 5/02

Our test team provided me with some additional information about our
antenna that is used for testing. Today, they ran a quick check of the
antenna factors of the 1-18 GHz antenna and compared the results to those
provided by the manufacturer. The results are attached. The quick check
factors agree pretty well with the manufacturer provided factors.


 Freq (MHz)        Thru     Measured        Attenuation Edmax        AF      AF     Delta
                              Sig                                           (mfg)
      1000        103.36     76.25            27.11       12.45     25.32    22.8   2.52
      5000         99.26     65.36             33.9       12.54     35.75    33.9   1.85
     10000         96.25     56.82            39.43       12.54     41.53    38.7   2.83
     18000        102.78     54.19            48.59       12.51     48.64    46.8   1.84