4.3.1. Standalone SAR test exclusion considerations
100 MHz to 6 GHz at separation distance less than or equal to 50 mm

SAR Test Exclusion Calculator
Insert values in yellow highlighted boxes to determine SAR Exclusion
Max Power            2 mW
Min Separation        5 mm         When the minimum test separation distance is < 5 mm, a distance of 5 mm is
Frequency           2.4 GHz        applied to determine SAR test exclusion.

Answer             0.6 Must be less than or equal to 3.0 for SAR Exclusion


Please also note the following: [FCC KDB quote] These test exclusion conditions are based on source-
based time-averaged maximum conducted output power of the RF channel requiring evaluation, adjusted for tune-up
tolerance, and the minimum test separation distance required for the exposure conditions. The minimum test separation
distance is determined by the smallest distance from the antenna and radiating structures or outer surface. [End
quote]

RSS-102
Table 1: SAR evaluation – Exemption limits for routine evaluation based on
frequency and separation distance




The device operating with 2 mW output power and maintaining a distance ≤ 5 mm complies with the requirements of
RSS-102 Table 1 exclusion for SAR evaluation




Rogers Labs, Inc.                      Garmin International, Inc.       SN’s: 3991277094, 3991277142
4405 West 259th Terrace                Model: B03559                           FCC ID: IPH-B03559
Louisburg, KS 66053                    Test: 190410B                           IC: 1792A-B03559
Phone/Fax: (913) 837-3214              Test to: 47 CFR 15C, RSS-Gen RSS-247    Date: June 4, 2019
Revision 1                             File: B03559 RF Exemption               Page 1 of 1