Test Report DXX

FCC ID: IPH-A3405

Test Report

Download: PDF
FCCID_4127195

                      Engineering Solutions & Electromagnetic Compatibility Services
                              FCC Part 15.225 Certification Application Report

  Test Lab:                                                     Applicant:

  Rhein Tech Laboratories, Inc.  Phone: 703-689-0368            Garmin International Inc.
  360 Herndon Parkway            Fax:   703-689-2056            1200 E. 151st Street
  Suite 1400                     www.rheintech.com              Olathe, Kansas 66062
  Herndon, VA 20170
  E-Mail: atcbinfo@rheintech.com

  FCC ID                       IPH-A3405                        Test Report Date            August 1, 2018
  Platform                     N/A                              RTL Work Order #            2018134
  Model #                      AA3405                           RTL Quote #                 QRTL18-134A
  American National            ANSI C63.10-2013: American National Standard of Procedures for
  Standard Institute           Compliance Testing of Unlicensed Wireless Devices

  FCC Classification           DXX – Part 15 Low Power Communication Device Transmitter

                               Part 15.225: Operation within the band 13.110-14.010 MHz (10-01-17)
  FCC Rule Part(s)
                               Part 2.1049: Measurements required: Occupied Bandwidth (06-14-17)
                                                                                          Emission
  Frequency Range (MHz)             Output Power (W)          Frequency Tolerance
                                                                                         Designator
              13.56                        N/A                         N/A                   N/A

I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the
identified standard(s) as described in this test report. No modifications were made to the equipment during
testing in order to achieve compliance with these standards. Furthermore, there was no deviation from,
additions to, or exclusions from, the applicable parts of FCC Part 2, FCC Part 15, and ANSI C63.10.



Signature:                                                                     Date: August 1, 2018

Typed/Printed Name: Desmond A. Fraser                                          Position: President


        These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANAB.
                           Refer to certificate and scope of accreditation AT-1445.

 This report may not be reproduced, except in full, without the written approval of Rhein Tech Laboratories,
             Inc. and Garmin International Inc. The test results relate only to the item(s) tested.




                              360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170
                            Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com


Rhein Tech Laboratories, Inc.                                                                                             Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                                                              Model #: AA3405
Suite 1400                                                                                                                 Standard: FCC 15.225
Herndon, VA 20170                                                                                                             FCC ID: IPH-A3405
http://www.rheintech.com                                                                                                  Report #: 2018134DXX

                                                                 Table of Contents

1     General Information .......................................................................................................................... 4
    1.1    Scope ...................................................................................................................................... 4
    1.2    Description of EUT ................................................................................................................... 4
    1.3    Test Facility .............................................................................................................................. 4
    1.4    Related Submittal(s)/Grant(s) ................................................................................................... 4
    1.5    Modifications ............................................................................................................................ 4
2     Test Information ............................................................................................................................... 5
    2.1    Description of Test Modes ........................................................................................................ 5
    2.2    Exercising the EUT................................................................................................................... 5
    2.3    Test Result Summary ............................................................................................................... 5
    2.4    Test System Details ................................................................................................................. 5
    2.5    Configuration of Tested System................................................................................................ 6
3     AC Conducted Emissions - FCC 15.207 ........................................................................................... 7
    3.1    Site and Test Description.......................................................................................................... 7
    3.2    Test Limits................................................................................................................................ 7
    3.3    Measurement Uncertainty......................................................................................................... 7
    3.4    Conducted Emissions Test Data ............................................................................................... 8
4     Radiated Emissions – FCC 15.209, 15.225(a) & (d) ........................................................................ 10
    4.1    Limits of Radiated Emissions Measurement............................................................................ 10
    4.2    Radiated Emissions Measurement Test Procedure ................................................................. 10
    4.3    Measurement Uncertainty....................................................................................................... 10
    4.4    Radiated Emissions Test Data................................................................................................ 11
    4.5    Radiated Emissions Harmonics/Spurious Test Data ............................................................... 11
    4.6    Radiated Emissions Digital Test Data ..................................................................................... 13
5     Occupied Bandwidth – FCC Part 2.1049 ......................................................................................... 14
    5.1    99% Bandwidth Test Procedure ............................................................................................. 14
    5.2    Measurement Uncertainty....................................................................................................... 14
    5.3    99% Bandwidth Test Data ...................................................................................................... 14
    5.4    99% Bandwidth Plots ............................................................................................................. 15
6     Frequency Stability – FCC 2.1055, 15.225(e).................................................................................. 18
    6.1    Test Procedure....................................................................................................................... 18
    6.2    Measurement Uncertainty....................................................................................................... 18
    6.3    Test Data ............................................................................................................................... 18
7     Conclusion ..................................................................................................................................... 19




                                                                                                                                      Page 2 of 23


Rhein Tech Laboratories, Inc.                                                                                     Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                                                      Model #: AA3405
Suite 1400                                                                                                         Standard: FCC 15.225
Herndon, VA 20170                                                                                                     FCC ID: IPH-A3405
http://www.rheintech.com                                                                                          Report #: 2018134DXX

                                                               Figure Index

Figure 2-1:      Configuration of System Under Test ......................................................................................6

                                                               Table Index

Table 2-1:       Channels Tested ...................................................................................................................5
Table 2-2:       Test Result Summary ............................................................................................................5
Table 2-3:       Equipment Under Test ...........................................................................................................5
Table 2-4:       Auxiliary Equipment ...............................................................................................................5
Table 3-1:       Conducted Emissions Limits ..................................................................................................7
Table 3-2:       Conducted Emissions Environmental Condition .....................................................................8
Table 3-3:       Conducted Emissions Test Equipment ...................................................................................9
Table 4-1:       Radiated Emissions Limits ...................................................................................................10
Table 4-2:       Radiated Emissions Environmental Condition ...................................................................... 11
Table 4-3:       Radiated Emissions Test Data (Fundamental) ..................................................................... 11
Table 4-4:       Radiated Emissions Harmonics/Spurious: TVDD 3.20 V ..................................................... 11
Table 4-5:       Radiated Emissions Harmonics/Spurious: TVDD 3.90 V ..................................................... 12
Table 4-6:       Radiated Emissions Harmonics/Spurious: TVDD 4.75 V ..................................................... 12
Table 4-7:       Digital Radiated Emissions Test Data .................................................................................. 13
Table 4-8:       Radiated Emissions Test Equipment.................................................................................... 13
Table 5-1:       99% OBW Environmental Condition..................................................................................... 14
Table 5-2:       99% Bandwidth ...................................................................................................................14
Table 5-3:       99% Bandwidth Test Equipment .......................................................................................... 17
Table 6-1:       Frequency Stability Environmental Condition ....................................................................... 18
Table 6-2:       Temperature Frequency Stability ......................................................................................... 18
Table 6-3:       TVDD Voltage Frequency Stability at 20°C .......................................................................... 19
Table 6-4:       Frequency Stability Test Equipment ..................................................................................... 19

                                                                Plot Index

Plot 3-1:     Conducted Emissions – Neutral .................................................................................................8
Plot 3-2:     Conducted Emissions – Phase ..................................................................................................9
Plot 5-1:     99% Bandwidth – 3.20 V .........................................................................................................15
Plot 5-2:     99% Bandwidth – 3.90 V .........................................................................................................16
Plot 5-3:     99% Bandwidth – 4.75 V .........................................................................................................16

                                                             Appendix Index

Appendix A: Test Configuration Photographs………………………………………………………………………29

                                                           Photograph Index

Photograph 1:       Radiated Emissions Test Setup – Front (Below 30 MHz) .................................................. 20
Photograph 2:       Radiated Emissions Test Setup – Rear (Below 30 MHz) .................................................. 20
Photograph 3:       Radiated Emissions Test Setup – Front (30 MHz – 1000 MHz) ........................................ 21
Photograph 4:       Radiated Emissions Test Setup – Rear (30 MHz – 1000 MHz) ......................................... 21
Photograph 5:       Radiated Emissions Test Setup – Front (Above 1000 MHz) ............................................. 22
Photograph 6:       Radiated Emissions Test Setup – Rear (Above 1000 MHz) .............................................. 22
Photograph 7:       Conducted Emissions Test Setup .................................................................................... 23
Photograph 8:       Frequency Stability Test Setup......................................................................................... 23




                                                                                                                              Page 3 of 23


Rhein Tech Laboratories, Inc.                                                        Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                         Model #: AA3405
Suite 1400                                                                            Standard: FCC 15.225
Herndon, VA 20170                                                                        FCC ID: IPH-A3405
http://www.rheintech.com                                                             Report #: 2018134DXX

1     General Information

1.1       Scope

Applicable Standards:

      •    FCC Part 2.1049: Measurements required: Occupied Bandwidth

          FCC Part 15.225: Operation within the band 13.110-14.010 MHz

1.2       Description of EUT

Equipment Under Test              Body-worn transmitter
Model #                           AA3405
Power Supply                      Battery operated
Modulation Type                   ASK
Frequency Range                   13.56 MHz
Antenna Connector Type            Magnet Loop
Antenna Type                      Internal

1.3       Test Facility

The open area test site and conducted measurement facility used to collect the radiated data is located at
360 Herndon Parkway, Suite 1400, Herndon, Virginia 20170. This site has been fully described in a report
and approved by the Federal Communications Commission to perform AC line conducted and radiated
emissions testing.

1.4       Related Submittal(s)/Grant(s)

This is an original certification application for Garmin International Inc. Model #: AA3405, FCC ID: IPH-A3405.

1.5       Modifications

No modifications were made to the equipment during testing in order to achieve compliance with these
standards.




                                                                                              Page 4 of 23


Rhein Tech Laboratories, Inc.                                                      Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                       Model #: AA3405
Suite 1400                                                                          Standard: FCC 15.225
Herndon, VA 20170                                                                      FCC ID: IPH-A3405
http://www.rheintech.com                                                           Report #: 2018134DXX

2     Test Information

2.1     Description of Test Modes

Table 2-1:        Channels Tested
                                            Frequency (MHz)
                                                 13.56

2.2     Exercising the EUT

The EUT is a watch with a touch screen capability and one manual button on the right side. The EUT was
supplied with test firmware programmed with modulation types and rates. The EUT was tested in all three
orthogonal planes in order to determine worst-case emissions. The EUT was provided with software to
continuously transmit during testing. The carrier was also checked to verify that information was being
transmitted. An NFC card was provided to be placed near the EUT for proper normal operating mode. The
NFC card has a blue LED that would light when placed in close proximity to the EUT.

2.3     Test Result Summary

Table 2-2:        Test Result Summary
                                                                                             Pass/Fail
      FCC Standard                                  Test
                                                                                              or N/A
FCC 15.207                AC Power Conducted Emissions                                         Pass
FCC 15.209                Radiated Emissions                                                   Pass
FCC 15.225(a), (d)        Field Strength of Fundamental and Harmonics                          Pass
                          99% Bandwidth                                                        Pass
FCC 15.225(e)             Frequency Stability                                                  Pass

2.4     Test System Details

The test samples were received on July 16, 2018. The FCC identifiers for all applicable equipment, plus
descriptions of all cables used in the tested system, are identified in the following table.

Table 2-3:        Equipment Under Test
                                                                                                      RTL
                                                         Serial                        Cable
       Part          Manufacturer         Model                         FCC ID                         Bar
                                                        Number                       Description
                                                                                                      Code
    Body-worn           Garmin
                                         AA3405            N/A        IPH-A3405           N/A        23067
    transmitter    International Inc.

Table 2-4:        Auxiliary Equipment
                                                                                                      RTL
                                                         Serial                        Cable
       Part          Manufacturer         Model                         FCC ID                         Bar
                                                        Number                       Description
                                                                                                      Code
NFC Detector
                         NXP            PCB2377-2          N/A            N/A             N/A        23066
   Board




                                                                                            Page 5 of 23


Rhein Tech Laboratories, Inc.                             Client: Garmin Int’l Inc.
360 Herndon Parkway                                              Model #: AA3405
Suite 1400                                                 Standard: FCC 15.225
Herndon, VA 20170                                             FCC ID: IPH-A3405
http://www.rheintech.com                                  Report #: 2018134DXX

2.5   Configuration of Tested System




                                NFC Detector        EUT
                                   Board




Figure 2-1:    Configuration of System Under Test




                                                                   Page 6 of 23


Rhein Tech Laboratories, Inc.                                                       Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                        Model #: AA3405
Suite 1400                                                                           Standard: FCC 15.225
Herndon, VA 20170                                                                       FCC ID: IPH-A3405
http://www.rheintech.com                                                            Report #: 2018134DXX

3     AC Conducted Emissions - FCC 15.207

3.1     Site and Test Description

The power line conducted emissions measurements were performed in a Series 81 type shielded enclosure
manufactured by Rayproof. The EUT was assembled on a wooden table 80 centimeters high. Power was
fed to the EUT through a 50-ohm/50 microhenry Line Impedance Stabilization Network (LISN). The EUT
LISN was fed power through an A.C. filter box on the outside of the shielded enclosure. The filter box and
EUT LISN housing are bonded to the ground plane of the shielded enclosure. A second LISN, the peripheral
LISN, provides isolation for the EUT test peripherals. This peripheral LISN was also fed A.C. power. A
metal power outlet box, which is bonded to the ground plane and electrically connected to the peripheral
LISN, powers the EUT host peripherals.

The spectrum analyzer was connected to the AC line through an isolation transformer. The 50-ohm output
of the EUT LISN was connected to the spectrum analyzer input through a Solar 100 kHz high-pass filter.
The filter is used to prevent overload of the spectrum analyzer from noise below 100 kHz. Conducted
emission levels were measured on each current-carrying line with the spectrum analyzer operating in the
CISPR quasi-peak mode (or peak mode if applicable).

The analyzer's 6 dB bandwidth was set to 9 kHz. Video filter less than 10 times the resolution bandwidth is
not used. Average measurements are performed in linear mode using a 10 kHz resolution bandwidth, a 1
Hz video bandwidth, and by increasing the sweep time in order to obtain a calibrated measurement. The
emission spectrum was scanned from 150 kHz to 30 MHz. The highest emission amplitudes relative to the
appropriate limits were measured and have been recorded.

3.2     Test Limits

Table 3-1:       Conducted Emissions Limits
                                    Line-Conducted Emissions
                                            Limit (dBµV)
         Frequency (MHz)                    Quasi-Peak                                 Average
            0.15 to 0.50                      66 to 56                                 56 to 46
            0.50 to 5.00                         56                                      46
           5.00 to 30.00                         60                                      50

3.3     Measurement Uncertainty

Measurement uncertainties shown for these tests are expanded uncertainties expressed at 95% confidence
level using a coverage factor k = 2.

Conducted Emissions: ±2.5 dB




                                                                                             Page 7 of 23


Rhein Tech Laboratories, Inc.                                                 Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                  Model #: AA3405
Suite 1400                                                                     Standard: FCC 15.225
Herndon, VA 20170                                                                 FCC ID: IPH-A3405
http://www.rheintech.com                                                      Report #: 2018134DXX

3.4     Conducted Emissions Test Data

Table 3-2:     Conducted Emissions Environmental Condition
          Date             Temperature (°F)         Humidity (%)                  Pressure (kPa)
     July 26, 2018               73.0                     25                          101.2

Plot 3-1:        Conducted Emissions – Neutral
         Project # - 2018134                  Rhein Tech Laboratories, Inc.            Line 2 - Neutral
         Company - Garmin                         Class B: 120V 60Hz                  FCC _B_AVG
         Model # AA3405                            RFID A 3.9V: Neutral               FCC _B_QP
                           Amplitude (dBuV)




               100.0
                90.0
                80.0
                70.0
                60.0
                50.0
                40.0
                30.0
                20.0
                10.0
                  0
                 150.0K                            1.0M                       10.0M            30.0M
                                                          Frequency (MHz)




Note:    Technology Type A was observed.




                                                                                       Page 8 of 23


Rhein Tech Laboratories, Inc.                                                    Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                     Model #: AA3405
Suite 1400                                                                        Standard: FCC 15.225
Herndon, VA 20170                                                                    FCC ID: IPH-A3405
http://www.rheintech.com                                                         Report #: 2018134DXX

Plot 3-2:        Conducted Emissions – Phase

        Project # - 2018134                  Rhein Tech Laboratories, Inc.                 Line 1 - Phase
        Company - Garmin                         Class B: 120V 60Hz                       FCC _B_AVG
        Model # AA3405                            RFID A 3.9V: Phase
                                                                                          FCC _B_QP

                          Amplitude (dBuV)
              100.0
               90.0
               80.0
               70.0
               60.0
               50.0
               40.0
               30.0
               20.0
               10.0
                 0
                150.0K                            1.0M                          10.0M              30.0M
                                                         Frequency (MHz)




Note:   Technology Type A was observed.

Result: Pass

Table 3-3:    Conducted Emissions Test Equipment
  RTL                                                                           Serial        Calibration
           Manufacturer    Model                Part Type
 Asset #                                                                       Number          Due Date
              Hewlett                      Quasi-Peak Adapter
 900339                   85650A                                             2521A00743          4/26/19
             Packard                         (30 Hz – 1 GHz)
              Hewlett                      Spectrum Analyzer
 900968                    8567A                                             2602A00160          4/26/19
             Packard                       (10 kHz – 1.5 GHz)
              Hewlett                           Spectrum
 900970                   85662A                                             2542A11239          4/26/19
             Packard                        Analyzer Display
               AFJ
 901082                     LS16                16A LISN                     16010020081         2/13/21
           International
  Test       Quantum
                           TILE!7          TILE! Test Software                 7.1.3.20           N/A
Software      Change

Test Personnel:

            Khue N. Do                                                           July 26, 2018

        EMC Test Engineer                            Signature                    Date of Test




                                                                                           Page 9 of 23


Rhein Tech Laboratories, Inc.                                                       Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                        Model #: AA3405
Suite 1400                                                                           Standard: FCC 15.225
Herndon, VA 20170                                                                       FCC ID: IPH-A3405
http://www.rheintech.com                                                            Report #: 2018134DXX

4     Radiated Emissions – FCC 15.209, 15.225(a) & (d)

4.1     Limits of Radiated Emissions Measurement

Table 4-1:      Radiated Emissions Limits
       Frequency (MHz)                 Field Strength (µV/m)                 Measurement Distance (m)
           0.009-0.490                      2400/f (kHz)                              300
           0.490-1.705                      2400/f (kHz)                               30
            1.705-30.0                           30                                    30
               30-88                            100                                     3
              88-216                            150                                     3
             216-960                            200                                     3
            Above 960                           500                                     3

As shown in 15.35(b), for frequencies above 1000 MHz, the field strength limits are based on average
detector however, the peak field strength of any emission shall not exceed the maximum permitted average
limits specified above by more than 99% under any circumstances of modulation.

15.225(a) states “The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed
15,848 microvolts/meter at 30 meters.”

         20 * log(15,848) = 84.0 dBµV/m at 30 m.

15.225(d) stated “The field strength of any emissions appearing outside of the 13.110– 14.010 MHz band
shall not exceed the general radiated emission limits in §15.209.”

4.2     Radiated Emissions Measurement Test Procedure

Before final measurements of radiated emissions were made on the open-field three/ten meter range, the
EUT was scanned indoors at one and three meter distances. This was done in order to determine its
emissions spectrum signature. The physical arrangement of the test system and associated cabling was
varied in order to determine the effect on the EUT's emissions in amplitude, direction and frequency. This
process was repeated during final radiated emissions measurements on the open-field range, at each
frequency, in order to ensure that maximum emission amplitudes were attained.

Final radiated emissions measurements were made on the three/ten-meter, open-field test site. The EUT
was placed on a nonconductive turntable 0.8 meters above the ground plane. The spectrum was examined
from 9 kHz to the 10th harmonic of the highest fundamental transmitter frequency (135.6 MHz).

At each frequency, the EUT was rotated 360°, and the antenna was raised and lowered from 1 to 4 meters in
order to determine the emission’s maximum level. Measurements were taken using both horizontal and
vertical antenna polarizations. For frequencies between 30 MHz and 1000 MHz, the spectrum analyzer’s 6
dB bandwidth was set to 120 kHz, and the analyzer was operated in the CISPR quasi-peak detection mode.
For emissions above 1000 MHz, emissions are measured using the average detector function with a
minimum resolution bandwidth of 1 MHz. No video filter less than 10 times the resolution bandwidth was
used. The highest emission amplitudes relative to the appropriate limit were measured and recorded in this
report.
4.3     Measurement Uncertainty

Measurement uncertainties shown for these tests are expanded uncertainties expressed at 95% confidence
level using a coverage factor k = 2.

Radiated Emissions:     ±4.6 dB

                                                                                            Page 10 of 23


Rhein Tech Laboratories, Inc.                                                  Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                   Model #: AA3405
Suite 1400                                                                      Standard: FCC 15.225
Herndon, VA 20170                                                                  FCC ID: IPH-A3405
http://www.rheintech.com                                                       Report #: 2018134DXX

4.4     Radiated Emissions Test Data

Table 4-2:     Radiated Emissions Environmental Condition
          Date              Temperature (°F)         Humidity (%)                  Pressure (kPa)
     July 30, 2018                75.0                    85                            99.6

Table 4-3:      Radiated Emissions Test Data (Fundamental)
                        Quasi-        Site        Quasi-     Quasi-          Quasi-
TVDD      Frequency      Peak     Correction       Peak       Peak            Peak          Result
 (V)        (MHz)      Reading      Factor      Corrected    Limit           Margin       (Pass / Fail)
                      (dBµV/m)      (dB/m)      (dBµV /m)  (dBµV /m)          (dB)
3.20        13.56        -1.4        30.5          29.1       84.0            -54.9           Pass
3.90        13.56        -1.3        30.5          29.2       84.0            -54.8           Pass
4.75        13.56        -1.2        30.5          29.3       84.0            -54.7           Pass

Note 1: Technology Type A was observed.

Note 2: Fundamental measurements were taken at 3m. Levels were extrapolated to 30 m from 3 m (-20.0
        dB).

          20 * log (30 m / 3 m) = 20.0 dB

4.5     Radiated Emissions Harmonics/Spurious Test Data

Table 4-4:        Radiated Emissions Harmonics/Spurious: TVDD 3.20 V
                                    Site
 Emission          Analyzer
                                Correction   Corrected       Limit           Margin          Result
Frequency           Reading
                                  Factor     (dBµV/m)      (dBµV/m)           (dB)         (Pass / Fail)
  (MHz)            (dBµV/m)
                                  (dB/m)
       27.12         -17.8          32.7        14.9         29.5             -14.6            Pass
       40.68         17.0          -16.1         0.9         40.0             -39.1            Pass
       54.24         24.0          -22.3         1.7         40.0             -38.3            Pass
       67.80         26.4          -23.3         3.1         40.0             -36.9            Pass
       81.36         23.1          -21.3         1.8         40.0             -38.2            Pass
       94.92         40.4          -18.7        21.7         43.5             -21.8            Pass
      108.48         15.9          -17.3        -1.4         43.5             -44.9            Pass
      122.04         27.1          -17.0        10.1         43.5             -33.4            Pass
      135.60         16.3          -17.4        -1.1         43.5             -44.6            Pass

Note:     Technology Type A was observed.




                                                                                      Page 11 of 23


Rhein Tech Laboratories, Inc.                                        Client: Garmin Int’l Inc.
360 Herndon Parkway                                                         Model #: AA3405
Suite 1400                                                            Standard: FCC 15.225
Herndon, VA 20170                                                        FCC ID: IPH-A3405
http://www.rheintech.com                                             Report #: 2018134DXX

Table 4-5:     Radiated Emissions Harmonics/Spurious: TVDD 3.90 V
                                 Site
 Emission       Analyzer
                             Correction   Corrected       Limit     Margin         Result
Frequency        Reading
                               Factor     (dBµV/m)      (dBµV/m)     (dB)        (Pass / Fail)
  (MHz)         (dBµV/m)
                               (dB/m)
    27.12         -17.3          32.7        15.4         29.5      -14.1            Pass
    40.68         17.1          -16.1         1.0         40.0      -39.0            Pass
    54.24         24.1          -22.3         1.8         40.0      -38.2            Pass
    67.80         26.9          -23.3         3.6         40.0      -36.4            Pass
    81.36         23.7          -21.3         2.4         40.0      -37.6            Pass
    94.92         41.4          -18.7        22.7         43.5      -20.8            Pass
   108.48         16.6          -17.3        -0.7         43.5      -44.2            Pass
   122.04         28.0          -17.0        11.0         43.5      -32.5            Pass
   135.60         16.9          -17.4        -0.5         43.5      -44.0            Pass

Note:   Technology Type A was observed.

Table 4-6:     Radiated Emissions Harmonics/Spurious: TVDD 4.75 V
                                 Site
 Emission       Analyzer
                             Correction   Corrected       Limit     Margin         Result
Frequency        Reading
                               Factor     (dBµV/m)      (dBµV/m)     (dB)        (Pass / Fail)
  (MHz)         (dBµV/m)
                               (dB/m)
    27.12         -17.7          32.7        15.0         29.5      -14.5            Pass
    40.68         18.5          -16.1         2.4         40.0      -37.6            Pass
    54.24         24.3          -22.3         2.0         40.0      -38.0            Pass
    67.80         27.7          -23.3         4.4         40.0      -35.6            Pass
    81.36         24.2          -21.3         2.9         40.0      -37.1            Pass
    94.92         41.0          -18.7        22.3         43.5      -21.2            Pass
   108.48         17.0          -17.3        -0.3         43.5      -43.8            Pass
   122.04         28.1          -17.0        11.1         43.5      -32.4            Pass
   135.60         17.0          -17.4        -0.4         43.5      -43.9            Pass

Note:   Technology Type A was observed.

Result: Pass




                                                                             Page 12 of 23


Rhein Tech Laboratories, Inc.                                                   Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                    Model #: AA3405
Suite 1400                                                                       Standard: FCC 15.225
Herndon, VA 20170                                                                   FCC ID: IPH-A3405
http://www.rheintech.com                                                        Report #: 2018134DXX

4.6     Radiated Emissions Digital Test Data

Table 4-7:       Digital Radiated Emissions Test Data
                                                  Site
 Emission                          Analyzer                                                       Result
               Antenna Height                 Correction   Corrected     Limit        Margin
Frequency                           Reading                                                       (Pass /
                (H / V)     (m)                 Factor     (dBµV/m)    (dBµV/m)        (dB)
  (MHz)                            (dBµV/m)                                                        Fail)
                                                (dB/m)
  149.16          H         1.0       15.9       -17.9       -2.0        43.5          -45.5       Pass
  162.72          V         1.0       17.6       -18.1       -0.5        43.5          -44.0       Pass
  216.96          V         1.0       12.8       -18.9       -6.1        46.0          -52.1       Pass
  230.52          H         1.0       12.8       -17.4       -4.6        46.0          -50.6       Pass
  244.08          H         1.0       14.6       -15.8       -1.2        46.0          -47.2       Pass
  271.20          V         1.0       12.7       -14.2       -1.5        46.0          -47.5       Pass

Note:    Technology Type A was observed.

Result: Pass

Table 4-8:    Radiated Emissions Test Equipment
  RTL                                                                       Serial          Calibration
            Manufacturer      Model                Part Type
Asset #                                                                    Number            Due Date
                                                 Bilog Antenna
900791         Chase        CBL6111B                                            N/A             10/4/20
                                            (30 MHz – 2000 MHz)
             Rhein Tech                   OATS 1 Preamplifier 40dB
900811                       PR-1040                                        1003                7/6/19
            Laboratories                       (30 MHz – 2 GHz)
             Rhein Tech     AM3-1197-       3 meter antenna mast,          Outdoor
900878                                                                                           N/A
            Laboratories      0005                 polarizing              Range 1
                                           EMI Receiver RF Section
900913     Hewlett Packard   85462A                                      3325A00159             4/4/19
                                               (9 kHz – 6.5 GHz)
                                                RF Filter Section,
900914     Hewlett Packard   8546OA                                      3330A00107             4/4/19
                                             (100 kHz – 6.5 GHz)
             Rhein Tech     WRT-000-
901242                                        Wood rotating table               N/A              N/A
            Laboratories      0003
               Agilent                        Spectrum Analyzer
901583                       N9010A                                      MY51250846             2/6/20
            Technologies                      (10 Hz – 26.5 GHz)
              Rohde &                            Loop Antenna
901663                       HFH2-Z2                                     827525/019             5/1/19
              Schwarz                          (9 kHz – 30 MHz)

Test Personnel:

             Khue N. Do                                                         July 30, 2018

        EMC Test Engineer                      Signature                         Date of Test




                                                                                       Page 13 of 23


Rhein Tech Laboratories, Inc.                                                       Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                        Model #: AA3405
Suite 1400                                                                           Standard: FCC 15.225
Herndon, VA 20170                                                                       FCC ID: IPH-A3405
http://www.rheintech.com                                                            Report #: 2018134DXX

5     Occupied Bandwidth – FCC Part 2.1049

5.1     99% Bandwidth Test Procedure

The 99% bandwidths per FCC Part 2.1049 were measured using a 50-ohm spectrum analyzer. The
modulated carrier was adjusted on the analyzer so that it was displayed entirely on the spectrum analyzer.
The sweep time was auto and allowed through several sweeps with the max hold function used in peak
detector mode.

• The transmitter shall be operated at its maximum carrier power measured under normal test conditions.
• The span of the analyzer shall be set to capture all products of the modulation process, including the
emission skirts.
• The resolution bandwidth (RBW) shall be in the range of 1% to 5% of the occupied bandwidth (OBW) and
video bandwidth (VBW) shall be approximately 3x RBW.

Note: Video averaging is not permitted.

5.2     Measurement Uncertainty

Measurement uncertainties shown for these tests are expanded uncertainties expressed at 95% confidence
level using a coverage factor k = 2.

99% OBW:        ±1.0 dB

5.3     99% Bandwidth Test Data

Table 5-1:     99% OBW Environmental Condition
          Date            Temperature (°F)                   Humidity (%)               Pressure (kPa)
     July 26, 2018             73.0                              25                         101.2

Table 5-2:      99% Bandwidth
                    TVDD (V)                                          99% Bandwidth (MHz)
                      3.20                                                  2.9652
                      3.90                                                  2.9618
                      4.75                                                  2.9602

Note:    Technology Type A was observed.




                                                                                           Page 14 of 23


Rhein Tech Laboratories, Inc.           Client: Garmin Int’l Inc.
360 Herndon Parkway                            Model #: AA3405
Suite 1400                               Standard: FCC 15.225
Herndon, VA 20170                           FCC ID: IPH-A3405
http://www.rheintech.com                Report #: 2018134DXX

5.4   99% Bandwidth Plots

Plot 5-1:      99% Bandwidth – 3.20 V




                                               Page 15 of 23


Rhein Tech Laboratories, Inc.           Client: Garmin Int’l Inc.
360 Herndon Parkway                            Model #: AA3405
Suite 1400                               Standard: FCC 15.225
Herndon, VA 20170                           FCC ID: IPH-A3405
http://www.rheintech.com                Report #: 2018134DXX

Plot 5-2:      99% Bandwidth – 3.90 V




Plot 5-3:      99% Bandwidth – 4.75 V




                                               Page 16 of 23


Rhein Tech Laboratories, Inc.                                            Client: Garmin Int’l Inc.
360 Herndon Parkway                                                             Model #: AA3405
Suite 1400                                                                Standard: FCC 15.225
Herndon, VA 20170                                                            FCC ID: IPH-A3405
http://www.rheintech.com                                                 Report #: 2018134DXX

Table 5-3:       99% Bandwidth Test Equipment
   RTL                                                                  Serial       Calibration
                 Manufacturer      Model            Part Type
  Asset #                                                              Number         Due Date
                    Agilent                     EXA Signal Analyzer
  901583                           N9010A                             MY51250846          2/6/20
                 Technologies                   (10 Hz – 26.5 GHz)

Test Personnel:

             Khue N. Do                                                   July 26, 2018

       EMC Test Engineer                    Signature                     Date of Test




                                                                                 Page 17 of 23


Rhein Tech Laboratories, Inc.                                                           Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                            Model #: AA3405
Suite 1400                                                                               Standard: FCC 15.225
Herndon, VA 20170                                                                           FCC ID: IPH-A3405
http://www.rheintech.com                                                                Report #: 2018134DXX

6     Frequency Stability – FCC 2.1055, 15.225(e)

6.1     Test Procedure

The carrier frequency stability is the ability of the transmitter to maintain an assigned carrier frequency.

15.255(e): The frequency tolerance of the carrier signal shall be maintained within ± 0.01 % of the operating
frequency over a temperature variation of -20 °C to +50 °C at normal supply voltage, and for a variation in
the primary supply voltage from 85 % to 115 % of the rated supply voltage at a temperature of 20 °C. For
battery-operated equipment, the equipment tests shall be performed using a new battery.

The EUT was evaluated over the temperature range -20 °C to +50 °C.

The temperature was initially set to -20 °C and a 1-hour period was observed for stabilization of the EUT.
The frequency stability was measured within one minute after application of primary power to the transmitter.
The temperature was raised at intervals of 10 degrees centigrade through the range. A ½-hour period was
observed to stabilize the EUT at each measurement step and the frequency stability was measured within
one minute after application of primary power to the transmitter. Additionally, the power supply voltage of the
EUT was varied ±15 % nominal input voltage.

6.2     Measurement Uncertainty

Measurement uncertainties shown for these tests are expanded uncertainties expressed at 95% confidence
level using a coverage factor k = 2.

Frequency Stability:      ±1.0 dB

6.3     Test Data

Table 6-1:     Frequency Stability Environmental Condition
          Date              Temperature (°F)           Humidity (%)                         Pressure (kPa)
     July 30, 2018                 75.0                    25                                   101.2
     July 31, 2018                 73.0                    24                                   101.2

Table 6-2:         Temperature Frequency Stability
                                                            Percent of Operating
       Temperature            Measured Frequency                                                Result
                                                                Frequency
          (°C)                      (MHz)                                                     (Pass / Fail)
                                                                    (%)
           -20.0                     13.55990                    -0.00074                         Pass
           -10.0                     13.56005                     0.00037                         Pass
             0.0                     13.56075                     0.00554                         Pass
            10.0                     13.55995                    -0.00038                         Pass
            20.0                     13.55995                    -0.00038                         Pass
            30.0                     13.56055                     0.00406                         Pass
            40.0                     13.56045                     0.00333                         Pass
            50.0                     13.56015                     0.00111                         Pass




                                                                                                Page 18 of 23


Rhein Tech Laboratories, Inc.                                                    Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                     Model #: AA3405
Suite 1400                                                                        Standard: FCC 15.225
Herndon, VA 20170                                                                    FCC ID: IPH-A3405
http://www.rheintech.com                                                         Report #: 2018134DXX

Table 6-3:      TVDD Voltage Frequency Stability at 20°C
                                                     Percent of Operating
          TVDD            Measured Frequency                                              Result
                                                         Frequency
            (V)                  (MHz)                                                  (Pass / Fail)
                                                             (%)
           3.20                 13.55990                  -0.00074                          Pass
           3.90                 13.56005                   0.00037                          Pass
           4.75                 13.56075                   0.00554                          Pass

Result: Pass

Table 6-4:       Frequency Stability Test Equipment
  RTL                                                                           Serial        Calibration
               Manufacturer       Model               Part Type
 Asset #                                                                       Number          Due Date
                 Tenney                         Temperature Chamber
 900946                           TH65                                          11380              3/26/19
             Engineering, Inc.                      with Humidity
                  Agilent                        EXA Signal Analyzer
 901583                          N9010A                                      MY51250846            2/6/20
               Technologies                      (10 Hz – 26.5 GHz)
 901672      Rohde & Schwarz     FSEM30           Spectrum Analyzer          1079.8500.30          4/17/19

Test Personnel:

             Khue N. Do                                                        July 30 – 31, 2018

       EMC Test Engineer                       Signature                          Dates of Test


7   Conclusion

The data in this measurement report shows that the EUT as tested, Garmin International Inc. Model # AA3405,
FCC ID: IPH-A3405, complies with the applicable requirements of Parts 2 and 15 of the FCC Rules and
Regulations.




                                                                                         Page 19 of 23



Document Created: 2019-03-24 23:07:15
Document Modified: 2019-03-24 23:07:15

© 2024 FCC.report