Test Report_DXX

FCC ID: IPH-03657

Test Report

Download: PDF
FCCID_4222106

                             FCC Test Report
            FCC ID                 : IPH-03657
            Equipment              : Marine Stereo
            Model No.              : A03657
            Brand Name             : FUSION
            Applicant              : Garmin International, Inc.
            Address                : 1200 E. 151st Street Olathe, KS 66062 United
                                     States
            Standard               : 47 CFR FCC Part 15.249
            Received Date          : Jan. 16, 2019
            Tested Date            : Jan. 30 ~ Jan. 31, 2019


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Reviewed by:                        Approved by:




      Along Chen / Assistant Manager      Gary Chang / Manager




Report No.: FR911601                                                                  Page : 1 of 19
Report Version: Rev. 01


                                                         Table of Contents
1        GENERAL DESCRIPTION .................................................................................................................... 5

1.1      Information.............................................................................................................................................. 5
1.2      Local Support Equipment List ................................................................................................................ 6
1.3      Test Setup Chart .................................................................................................................................... 6
1.4      The Equipment List ................................................................................................................................ 7
1.5      Test Standards ....................................................................................................................................... 8
1.6      Deviation from Test Standard and Measurement Procedure ................................................................. 8
1.7      Measurement Uncertainty ...................................................................................................................... 8

2        TEST CONFIGURATION ....................................................................................................................... 9

2.1      Testing Condition ................................................................................................................................... 9
2.2      The Worst Test Modes and Channel Details ......................................................................................... 9
2.3      Radiated Emission ...............................................................................................................................10
2.4      20dB and Occupied Bandwidth ............................................................................................................18

3        TEST LABORATORY INFORMATION ...............................................................................................19




Report No.: FR911601                                                                                                                Page : 2 of 19
Report Version: Rev. 01


                                    Release Record
     Report No.           Version                   Description      Issued Date
      FR911601            Rev. 01   Initial issue                   Mar. 29, 2019




Report No.: FR911601                                              Page : 3 of 19
Report Version: Rev. 01


                                     Summary of Test Results
   FCC Rules                            Test Items                            Measured                 Result
                                                                         1
      15.207           AC Power Line Conducted Emissions             Note                                   N/A
    15.249(a)          Field Strength of Fundamental                 Meet the requirement of limit      Pass
                       Field Strength of Harmonics and Emissions
   15.249(a)(d)        Radiated outside of the Specified Frequency   Meet the requirement of limit      Pass
                       Bands
    15.215(c)          20dB bandwidth                                Meet the requirement of limit      Pass
      15.203           Antenna Requirement                           Meet the requirement of limit      Pass
N/A means Not Applicable.
    1
Note : The EUT consumes DC power, so the test is not required.


Declaration of Conformity:
The test results with all measurement uncertainty excluded are presented in accordance with the regulation
limits or requirements declared by manufacturers.
Comments and Explanations:
The declared values of gain for EUT presented in the report are provided by the manufacturer, and the
manufacturer takes all the responsibilities for the accuracy of the gain.




Report No.: FR911601                                                                       Page : 4 of 19
Report Version: Rev. 01


1           General Description
1.1         Information
1.1.1       Specification of the Equipment under Test (EUT)
                                              RF General Information
 Frequency Range
                                 Modulation         Ch. Freq. (MHz)    Channel Number            Data Rate
      (MHz)
            2460                   GFSK                     2460            1 [1]                 1 Mbps


1.1.2       Antenna Details
 Ant. No.                 Type                 Gain (dBi)              Connector                 Remark
        1              Monopole                     0.95                  N/A                      ---


1.1.3       Power Supply Type of Equipment under Test (EUT)
Power Supply Type                 12 Vdc


1.1.4       Accessories
 No.               Equipment          Description
    1         Power cable x1          0.2m non-shielded without core
    2         Audio cable x2          0.2m non-shielded without core


1.1.5       EUT mode and Duty Cycle
EUT mode                               ANT Test
                                                  Duty Cycle (%)                    Duty Factor (dB)
Duty Cycle and Duty Factor
                                                           100                            0.00




Report No.: FR911601                                                                      Page : 5 of 19
Report Version: Rev. 01


1.2       Local Support Equipment List
                                           Support Equipment List
 No.        Equipment             Brand            Model             FCC ID           Remarks
   1         Notebook             DELL         Latitude E6430      G3GB4X1    ---
   2        USB Flash           Kingston           DTSE9             LXVW1    ---


1.3       Test Setup Chart
                                              Test Setup Diagram




 No.                                          Signal cable / Length (m)
  1    Antenna, 4.2m shielded.
  2    RJ45, 1m non-shielded.
  3    RJ45, 10m shielded.
  4    RF, 7.5m shielded.
  5    16 pin audio cable, 5m non-shielded.
  6    16 pin audio cable, 5m non-shielded.
  7    16 pin audio cable, 5m non-shielded.
  8    16 pin audio cable, 5m non-shielded.
  9    Audio, 1.8m shielded.
 10 Fiber, 1m non-shielded.
 11    SiriusXM, 1.2m shielded.
 12 USB, 2m shielded.
 13 Power cable, 5m non-shielded.


Report No.: FR911601                                                                Page : 6 of 19
Report Version: Rev. 01


1.4       The Equipment List
      Test Item      Radiated Emission
      Test Site      966 chamber1 / (03CH01-WS)
    Instrument            Manufacturer               Model No.                Serial No.        Calibration Date     Calibration Until
 Spectrum Analyzer            R&S                      FSV40                       101498        Dec. 27, 2018         Dec. 26, 2019
     Receiver                 R&S                      ESR3                        101658        Dec. 11, 2018         Dec. 10, 2019
   Bilog Antenna       SCHWARZBECK                   VULB9168               VULB9168-522          Jul. 18, 2018        Jul. 17, 2019
   Horn Antenna
                       SCHWARZBECK                 BBHA 9120 D            BBHA 9120 D 1096       Dec. 18, 2018         Dec. 17, 2019
       1G-18G
   Horn Antenna
                       SCHWARZBECK                   BBHA 9170              BBHA 9170517         Nov. 15, 2018         Nov. 14, 2019
      18G-40G
   Loop Antenna               R&S                     HFH2-Z2                      100330        Nov. 09, 2018         Nov. 08, 2019
   Loop Antenna
                          KOAX KABEL                 101354-BW                101354-BW          Oct. 08, 2018         Oct. 07, 2019
      Cable
    Preamplifier              EMC                    EMC02325                  980225            Jul. 20, 2018         Jul. 19, 2019
    Preamplifier             Agilent                  83017A                 MY39501308          Oct. 04, 2018         Oct. 03, 2019
    Preamplifier           EMC                    EMC184045B                   980192            Aug. 09, 2018         Aug. 08, 2019
     RF Cable              EMC                 EMC104-SM-SM-8000               181106            Oct. 08, 2018         Oct. 07, 2019
     RF Cable          HUBER+SUHNER              SUCOFLEX104                  MY16019/4          Oct. 08, 2018         Oct. 07, 2019
     RF Cable          HUBER+SUHNER             SUCOFLEX104                   MY16014/4          Oct. 08, 2018         Oct. 07, 2019
    LF cable 1M            EMC              EMCCFD400-NM-NM-1000               160502            Oct. 08, 2018         Oct. 07, 2019
    LF cable 3M              Woken                 CFD400NL-LW              CFD400NL-001         Oct. 08, 2018         Oct. 07, 2019
   LF cable 10M              Woken                 CFD400NL-LW              CFD400NL-002         Oct. 08, 2018         Oct. 07, 2019
   Measurement
                             AUDIX                       e3                   6.120210g               NA                    NA
     Software
Note: Calibration Interval of instruments listed above is one year.


      Test Item        RF Conducted
      Test Site        (TH01-WS)
      Instrument       Manufacturer            Model No.              Serial No.            Calibration Date       Calibration Until
 Spectrum Analyzer              R&S                   FSV40                 101063             Apr. 16, 2018          Apr. 15, 2019
 Spectrum Analyzer              R&S                   FSV40                 101499             Jan. 07, 2019          Jan. 06, 2020
 TEMP&HUMIDITY
                          GIANT FORCE          GCT-225-40-SP-SD          MAF1212-002           Dec. 05, 2018          Dec. 04, 2019
   CHAMBER
    Power Meter               Anritsu               ML2495A                1241002             Oct. 09, 2018          Oct. 08, 2019
    Power Sensor              Anritsu               MA2411B                1207366             Oct. 09, 2018          Oct. 08, 2019
     DC POWER
                            GW INSTEK              GPC-6030D              EM892433             Oct. 25, 2018          Oct. 24, 2019
      SOURCE
    Measurement
                              Sporton               Sporton_1                1.3.30                 NA                     NA
     Software
Note: Calibration Interval of instruments listed above is one year.




Report No.: FR911601                                                                                           Page : 7 of 19
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




1.5        Test Standards
According to the specification of EUT, the EUT must comply with following standards and KDB documents.

47 CFR FCC Part 15.249
ANSI C63.10—2013


1.6        Deviation from Test Standard and Measurement Procedure
None


1.7        Measurement Uncertainty
I1SO/IEC 17025 requires that an estimate of the measurement uncertainties associated with the emissions test
results be included in the report. The measurement uncertainties given below are based on a 95% confidence
level (based on a coverage factor (k=2)

                                          Measurement Uncertainty
                                    Parameters                                            Uncertainty
Bandwidth                                                                                 +34.130 Hz
Radiated emission < 1GHz                                                                   +3.41 dB
Radiated emission > 1GHz                                                                   +4.59 dB




Report No.: FR911601                                                                   Page : 8 of 19
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




2          Test Configuration
2.1        Testing Condition
          Test Item                    Test Site       Ambient Condition                Tested By
Radiated Emissions                   O3CHO1—WS          23—24°C / 62—65%               Akun Chung
RF Conducted                          THO1—WS              23°C / 65%                  Akun Chung
» FCC Designation No.:          TW2732
» FCC site registration No.:      181692
> IC site registration No.:     10807A—1



2.2         The Worst Test Modes and Channel Details
                        ;                            Test Frequency                               Test
                   Test item                  Mode        (MH2)            Data Rate         Configuration

AC Power Line Conducted Emissions             GFSK       2460               1 Mbps

Field Strength of Fundamental                 GFSK       2460               1 Mbps

Radiated Emissions S 1GHz                     GFSK       2460               1 Mbps

Radiated Emissions > 1GHz                     GFSK       2460               1 Mbps

200B bandwidth                                GFSK       2460               1 Mbps




Report No.: FR911601                                                                   Page : 9 of 19
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




2.3          Radiated Emission
This section includes field strength of fundamental, field strength of harmonics and emissions radiated outside
of the operating frequency bands.


2.3.1      Limit of field strength of fundamental and field strength of harmonics
      Fundamental Frequenc                  Field strength of fundamental              Field strength of harmonics
                           quency                  (millivolts/meter)                        (microvolts/meter)
          2400—2483.5 MHz                                   50                                        500


2.3.2      Limit of Unwanted Emissions
Emissions radiated outside of the specified frequency bands, except for harmonics, shall be attenuated by at
least 50 dB below the level of the fundamental or to the general radiated emission limits in below table,
whichever is the lesser attenuation.


                                               Radiated emission limits
Frequency Range (MHz)|           Field Strength (uV/m)         |Field Strength (dBuV/m)|        Measure Distance (m)
        0.009~0.490                    2400/F(kHz)                     48.5 — 13.8                          300
        0.490~1.705                   24000/F(kHz)                       33.8 — 23                          30
          1.705~30.0                         30                             29                              30
            30~88                           100                             40                               3
            88~216                          150                            43.5                              3
           216~960                          200                             46                               3
          Above 960                         500                             54                               3
Note 1:
Qusai—Peak value is measured for frequency below 1GHz except for 9—90 kHz, 110—490 kHz frequency band. Peak and
average value are measured for frequency above 1GHz. The limit on average radio frequency emission is as above
table. The limit on peak radio frequency emissions is 20 dB above the maximum permitted average emission limit
Note 2:
Measurements may be performed at a distance other than what is specified provided. When performing measurements
at a distance other than that specified, the results shall be extrapolated to the specified distance using an extrapolation
factor as below, Frequency at or above 30 MHz: 20 dB/decade Frequency below 30 MHz: 40 dB/decade.




Report No.: FR911601                                                                                 Page : 10 of 19
Report Version: Rev. 01


            Infernational
            Certification
            Corp.




2.3.3      Test Procedures
1.      Measurement is made at a semi—anechoic chamber that incorporates a turntable allowing a EUT
        rotation of 360°. A continuously—rotating, remotely—controlled turntable is installed at the test site to
        support the EUT and facilitate determination of the direction of maximum radiation for each EUT
        emission frequency. The EUT is placed at test table. For emissions testing at or below 1 GHz, the table
        height is 80 cm above the reference ground plane. For emission measurements above 1 GHz, the table
        height is 1.5 m
2.       Measurement is made with the antenna positioned in both the horizontal and vertical planes of
        polarization. The measurement antenna is varied in height (1m ~4m) above the reference ground plane
        to obtain the maximum signal strength. Distance between EUT and antenna is 3 m.
3.      This investigation is performed with the EUT rotated 360°, the antenna height scanned between 1 m
        and 4 m, and the antenna rotated to repeat the measurements for both the horizontal and vertical
        antenna polarizations.
Note:
q       Radiated emission below 1GHz
    _   120kHz measurement bandwidth of test receiver and Quasi—peak detector is for radiated emission
2       Radiated emission above 1GHz / Peak value except fundamental
    *   RBW=1MHz, VBW=3MHz and Peak detector
3.      Radiated emission above 1GHz / Average value for field strength of fundamental and harmonics
        The average value is: Average = Peak value + 20l0g(Duty cycle) Where the duty factor is calculated from following
        formula:
                                                           0.28507 x 2 ms
                            20l0g (Duty cycle) = 20log   ~~100ms —44.880B

        Please see page 17 for plotted duty

4       Radiated emission Peak value for fundamental
    *   RBW=3MHz, VBW=10MHz and Peak detector
5       Radiated emission Average value for fundamental
    *   RBW=3MHz, VBW=3kHz and Peak detector




Report No.: FR911601                                                                               Page : 11 of 19
Report Version: Rev. 01


2.3.4     Test Setup
Radiated Emissions below 1 GHz




Radiated Emissions above 1 GHz




Report No.: FR911601             Page : 12 of 19
Report Version: Rev. 01


2.3.5     Transmitter Radiated Unwanted Emissions (Below 1GHz)
Modulation                GFSK                       Test Freq. (MHz)             2460
Polarization              Horizontal




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).
Note 3: All spurious emissions below 30MHz are more than 20 dB below the limit.


Report No.: FR911601                                                                     Page : 13 of 19
Report Version: Rev. 01


Modulation                GFSK                       Test Freq. (MHz)             2460
Polarization              Vertical




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).
Note 3: All spurious emissions below 30MHz are more than 20 dB below the limit.




Report No.: FR911601                                                                     Page : 14 of 19
Report Version: Rev. 01


2.3.6     Transmitter Radiated Unwanted Emissions (Above 1GHz)
Modulation                GFSK                      Test Freq. (MHz)    2460
Polarization              Horizontal




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).



Report No.: FR911601                                                           Page : 15 of 19
Report Version: Rev. 01


Modulation                GFSK                      Test Freq. (MHz)    2460
Polarization              Vertical




Note 1: Emission Level (dBuV/m) = SA Reading (dBuV/m) + Factor* (dB)
      *Factor includes antenna factor , cable loss and amplifier gain
Note 2: Margin (dB) = Emission level (dBuV/m) – Limit (dBuV/m).




Report No.: FR911601                                                           Page : 16 of 19
Report Version: Rev. 01


                                                    0.28507 x 2 ms
                       20log (Duty cycle) = 20log         msms
                                                        100        = -44.88dB




Report No.: FR911601                                                            Page : 17 of 19
Report Version: Rev. 01


             Infernational
             Certification
             Corp.




2.4          20dB and Occupied Bandwidth
2.4.1        Test Procedures
        Set resolution bandwidth (RBW) = 100 kHz, Video bandwidth = 300 kHz.
por




        Detector = Peak, Trace mode = max hold
        Sweep = auto couple, Allow the trace to stabilize.
m 9




       Measure the maximum width of the emission that is constrained by the frequencies associated with the
       two outermost amplitude points (upper and lower) that are attenuated by 20dB relative to the maximum
       level measured in the fundamental emission.
5.      Use the occupied measurement function of specturm analyzer to measure 99% occupied bandwidth.


2.4.2        Test Setup


                                                                                                 Spectrum
                                                                                                 Analyzer




2.4.3        20dB and Occupied Bandwidth
               Freq. (MHz)                          200B Bandwidth (MHz)                                    Occupied Bandwidth (MHz)
                     2460                                          1.12                                                              0.93


              Worst Plot of 20dB Bandwidth                                                    Worst Plot of Occupied Bandwidth

 Specium                                                          (2)       [Specim                                                                                    )
  hat cover 117ET    maa ns                                                hat evel inm —ofmt ie s rew Tsme
  h            iwae B o me o Vaw Soo in mode                            |» ht         i9 ue B o me o VaM So0 in mtode Smeep
      *                                      tzu)           aas             e                                                 mm                                Yo7.as anon
                                                        wory                mss                                 T —occon                                 sonazontiner wl
                                         \            245042000                                             /             \
 100 chw—f           1       7                                              100 chw—f               1       e                 \\\    —

 so                                                                         so on                       y                           ~€ —
                                                                                                    1                                      N
                                                                            so on —|   A                                                       .
                                                                            naw———~  /                                                             \‘   </=
                                                                            soomn—A                 I                                                       \
                                                                             A"‘V‘A-f‘/                                                                           +
                                                                            Cik                                                                                        *
                                                                            so on —|
                                                                            so ce
                                                                            zomm
                                                            samez           [eczse ue                            aoiges                                       spmzome
                                                    Cmmwa               L                 X                                     ]                       Cmmwa




Report No.: FR911601                                                                                                                 Page : 18 of 19
Report Version: Rev. 01


C          Infernational
           Certification
           Corp.




3          Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp (EMC and Wireless Communication Laboratory), it is our definitive objective is
to institute long term, trust—based associations with our clients. The expectation we set up with our clients is
based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to
grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our
website http://www.icertifi.com.tw.


Linkou                                 Kwei Shan                            Kwei Shan Site II
Tel: 886—2—2601—1640                   Tel: 886—3—271—8666                  Tel: 886—3—271—8640
No. 30—2, Ding Fwu Tsuen, Lin          No. 3—1, Lane 6, Wen San 3rd St.,    No. 14—1, Lane 19, Wen San 3rd
Kou District, New Taipei City,         Kwei Shan District, Tao Yuan City    St., Kwei Shan District, Tao Yuan
Taiwan, R.0.C.                         333, Taiwan, R.O.C.                  City 333, Taiwan, R.O.C.

If you have any suggestion, please feel free to contact us as below information.

Tel: 886—3—271—8666
Fax: 886—3—318—0155
Email: ICC_Service@icertifi.com.tw




==END=




Report No.: FR911601                                                                       Page : 19 of 19
Report Version: Rev. 01



Document Created: 2019-04-02 10:21:49
Document Modified: 2019-04-02 10:21:49

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC