Test Report DXX

FCC ID: IPH-03571

Test Report

Download: PDF
FCCID_4237982

Testing
NVLAP Lab Code 200087-0




                            Application For
                          Grant of Certification
                                Model: A03571
                                2402-2480 MHz
                           47 CFR 15.249 and RSS-210
                             Low Power Transmitter

                                FCC ID: IPH-03571
                                 IC: 1792A-03571
                                                FOR



                     Garmin International, Inc.
                                    1200 East 151st Street
                                      Olathe, KS 66062

                               FCC Designation: US5305
                            IC Test Site Registration: 3041A-1
                               Test Report Number: 181022

Authorized Signatory:
                            Scot D. Rogers




Rogers Labs, Inc.                 Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace             Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053               Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214         Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                        File: A03571 DXX TstRpt 181022           Page 1 of 31


Testing
NVLAP Lab Code 200087-0




                              ROGERS LABS, INC.
                              4405 West 259th Terrace
                              Louisburg, KS 66053
                              Phone / Fax (913) 837-3214



                            Engineering Test Report For
                          Grant of Certification Application
                                                   for
                 47 CFR, PART 15C - Intentional Radiators Paragraph 15.249,
                   Industry Canada RSS-210 Issue 9, and RSS-GEN Issue 5
                             License Exempt Intentional Radiator
                                                   For

                            Garmin International, Inc.
                                          1200 East 151st Street
                                            Olathe, KS 66062

                                          Model: A03571

                                    Low Power Transmitter
                                     Frequency Range 2402-2480 MHz
                                           FCC ID: IPH-03571
                                            IC: 1792A-03571

Test Date: October 22, 2018

Certifying Engineer:
                             Scot D. Rogers
                             Rogers Labs, Inc.
                             4405 West 259th Terrace
                             Louisburg, KS 66053
                             Telephone/Facsimile: (913) 837-3214

This report shall not be reproduced except in full, without the written approval of the laboratory.
This report must not be used by the client to claim product certification, approval, or
endorsement by NVLAP, NIST, or any agency of the Federal Government.

Rogers Labs, Inc.                  Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace              Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214          Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                         File: A03571 DXX TstRpt 181022           Page 2 of 31


         Testing
         NVLAP Lab Code 200087-0

Table of Cont ents




Table of Contents
TABLE OF CONTENTS .................................................................................................. 3

REVISIONS..................................................................................................................... 4

FOREWORD ................................................................................................................... 5

OPINION / INTERPRETATION OF RESULTS ............................................................... 5

EQUIPMENT TESTED .................................................................................................... 6

                     Equipment Function ............................................................................................................................................7

                     Equipment Configuration....................................................................................................................................8

APPLICATION FOR CERTIFICATION ........................................................................... 9

APPLICABLE STANDARDS & TEST PROCEDURES ................................................ 10

TESTING PROCEDURES ............................................................................................ 10

                     AC Line Conducted Emission Test Procedure ................................................................................................ 10

                     Radiated Emission Test Procedure ................................................................................................................... 10

                       Diagram 1 Test arrangement for Conducted emissions ..................................................................................... 11
                       Diagram 2 Test arrangement for radiated emissions of tabletop equipment ...................................................... 12
                       Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS) ........................... 13

TEST SITE LOCATIONS .............................................................................................. 13

LIST OF TEST EQUIPMENT ........................................................................................ 14

UNITS OF MEASUREMENTS ...................................................................................... 15

ENVIRONMENTAL CONDITIONS................................................................................ 15

STATEMENT OF MODIFICATIONS AND DEVIATIONS ............................................. 15

INTENTIONAL RADIATORS ........................................................................................ 15

                     Antenna Requirements ...................................................................................................................................... 15

                     Restricted Bands of Operation .......................................................................................................................... 16

Rogers Labs, Inc.                                                Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                                            Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                                              Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214                                        Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                                                       File: A03571 DXX TstRpt 181022           Page 3 of 31


 Testing
 NVLAP Lab Code 200087-0



           Table 1 Radiated Emissions in Restricted Frequency Bands Data .................................................................... 16

        Summary of Results for Radiated Emissions in Restricted Bands ................................................................ 17

        AC Line Conducted EMI Procedure ................................................................................................................ 17

           Figure 1 AC Line Conducted emissions of EUT line 1 (#3, EUT – Computer) ................................................ 18
           Figure 2 AC Line Conducted emissions of EUT line 2 (#3, EUT – Computer) ................................................ 18
           Table 2 AC Line Conducted Emissions Data L1 (#3, EUT – Computer) .......................................................... 19
           Table 3 AC Line Conducted Emissions Data L2 (#3, EUT – Computer) .......................................................... 19

        Summary of Results for AC Line Conducted Emissions ................................................................................ 19

        General Radiated Emissions Procedure ........................................................................................................... 20

           Table 4 General Radiated Emissions Data ........................................................................................................ 21

        Summary of Results for General Radiated Emissions .................................................................................... 21

        Operation in the Band 2400 – 2483.5 MHz ...................................................................................................... 22

           Figure 3 Plot of Transmitter Emissions Operation in 2402-2480 MHz ............................................................. 23
           Figure 4 Plot of Transmitter Emissions 99% Occupied Bandwidth .................................................................. 23
           Figure 5 Plot of Transmitter Emissions Low Band Edge .................................................................................. 24
           Figure 6 Plot of Transmitter Emissions High Band Edge .................................................................................. 24

        Transmitter Emissions Data .............................................................................................................................. 25

           Table 5 Transmitter Radiated Emissions ........................................................................................................... 25

        Summary of Results for Transmitter Radiated Emissions of Intentional Radiator ..................................... 26

ANNEX .......................................................................................................................... 27

        Annex A Measurement Uncertainty Calculations ........................................................................................... 28

        Annex B Rogers Labs Additional Test Equipment List .................................................................................. 29

        Annex C Rogers Qualifications ......................................................................................................................... 30

        Annex D Rogers Labs Certificate of Accreditation ......................................................................................... 31



Revisions
Revision 1 Issued November 20, 2018

Rogers Labs, Inc.                                  Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                              Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                                Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214                          Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                                         File: A03571 DXX TstRpt 181022           Page 4 of 31


Testing
NVLAP Lab Code 200087-0




Foreword

The following information is submitted for consideration in obtaining Grant of Certification for
low power intentional radiator per 47 CFR Paragraph 15.249, Industry Canada RSS-210 Issue 9
and RSS-GEN Issue 5, low power digital device transmitter operations in the 2400 – 2483.5
MHz frequency band.
               Name of Applicant:   Garmin International, Inc.
                                    1200 East 151st Street
                                    Olathe, KS 66062
               M/N: A03571
               FCC ID: IPH-03571          IC: 1792A-03571
               Operating Frequency Range: 2402-2480 MHz
               BLE Average power of 77.4 dBµV/m @ 3, (peak 96.2 dBµV/m, OBW, 1049.7 kHz)


Opinion / Interpretation of Results
                             Tests Performed                      Margin (dB)      Results

   Restricted Bands 47 CFR 15.205, RSS-210 2.2                        -8.3        Complies

   AC Line Conducted 47 CFR 15.207, RSS-GEN 8.8                      -10.7        Complies

   Radiated Emissions 47 CFR 15.209, RSS-GEN 8.9                      -7.8        Complies

   Harmonic Emissions per 47 CFR 15.249, RSS-210 A2.9                 -5.4        Complies




Rogers Labs, Inc.                   Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace               Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                 Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214           Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                          File: A03571 DXX TstRpt 181022           Page 5 of 31


 Testing
 NVLAP Lab Code 200087-0




Equipment Tested

Equipment                       Model / PN              Serial Number

EUT                             A03571                  24361

EUT#2                           A03571                  24365

USB cable                       320-01325-00            N/A

USB cable                       320-01325-10            N/A

Laptop Computer                 Latitude E6320          FCN03Q1

USB Printer                     Dell 0N5819             5D1SL61

DC Adapter (CLA)                013-00797-00/01         N/A

DC Surveillance Mode Cable      320-00845-04            N/A

DC Power Supply                 BK 1745A                209C13

Test results in this report relate only to the items tested




Rogers Labs, Inc.               Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace           Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053             Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214       Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                      File: A03571 DXX TstRpt 181022           Page 6 of 31


Testing
NVLAP Lab Code 200087-0




Equipment Function

The EUT is a mobile mounted digital recording device incorporating wireless data transfer. The
device incorporates camera sensor and associated circuitry to record images within the lens view
angle. The design provides a single unique connection point for use of the USB interface cable
as well as slot for Micro SD memory card. The device offers no other interface options as
presented below in the configuration diagrams. The transmitters provide operation capability
across the 2402-2480 MHz frequency band. The design provides wireless communications with
compatible Bluetooth® (BT), and 802.11b/g/n (Wi-Fi) equipment. The product operates from
external direct current only and requires power from external source for operation. Power is
provided through compatible USB interface cable and power source. The design utilizes internal
fixed antenna system and offers no provision for antenna replacement or modification. Two
samples were provided for testing, one representative of production design, and the other
modified for testing purposes replacing the integral antenna with RF connection port. The test
samples were provided with test software (version 5.21) enabling testing personnel the ability to
enable transmitter functions on defined modulations and channels. The test software enabled
near 100% transmit duty cycle for testing purposes. The antenna modification offered testing
facility the ability to connect test equipment to the temporary antenna port for antenna port
conducted emission testing. For testing purposes, the EUT received powered from external
direct current sources (CPU-USB port or DC power supply) and configured to operate in
available modes. The EUT was arranged as described by the manufacturer emulating typical
user configurations for testing purposes. As requested by the manufacturer and required by
regulations, the equipment was tested for compliance using the available configurations with the
worst-case data presented. This report documents the performed testing and results for
applicable configurations and product modes of operation. Test results in this report relate only
to the products described in this report.




Rogers Labs, Inc.              Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace          Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053            Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214      Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                     File: A03571 DXX TstRpt 181022           Page 7 of 31


Testing
NVLAP Lab Code 200087-0




Equipment Configuration
  1) Unit connected to (and powered by) CLA through USB cable

                          Unit under Test                                                CLA
                                                    4m USB cable 320-01325-00
                                                                                   013-00797-00 or 01



      2) Unit connected to (and powered by) CLA through USB cable

                          Unit under Test                                                 CLA
                                                     1.5m USB cable 320-01325-10
                                                                                    013-00797-00 or 01


      3) Unit connected to (and powered by) Computer through USB cable

                          Unit under Test
                                                     1.5m USB cable 320-01325-10        Computer



      4) Unit connected to (and powered by) Surveillance Mode Cable

                          Unit under Test
                                                       Surveillance Mode Cable 320-00845-04




Rogers Labs, Inc.                           Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                       Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                         Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214                   Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                                  File: A03571 DXX TstRpt 181022           Page 8 of 31


Testing
NVLAP Lab Code 200087-0




Application for Certification
(1)            Manufacturer:          Garmin International, Inc.
                                      1200 East 151st Street
                                      Olathe, KS 66062
(2)            Identification: M/N: A03571
               FCC ID: IPH-03571             IC: 1792A-03571
(3)            Instruction Book:
               Refer to Exhibit for Instruction Manual.
(4)            Description of Circuit Functions:
               Refer to Exhibit of Operational Description.
(5)            Block Diagram with Frequencies:
               Refer to Exhibit of Operational Description.
(6)            Report of Measurements:
               Report of measurements follows in this Report.
(7)            Photographs: Construction, Component Placement, etc.:
               Refer to Exhibit for photographs of equipment.
(8)            List of Peripheral Equipment Necessary for operation. The equipment operates from
               external direct current power provided from compatible DC source. The EUT also provides
               communication options as documented and presented in this filing.
(9)            Transition Provisions of 47 CFR 15.37 are not requested.
(10)           Not Applicable. The unit is not a scanning receiver.
(11)           Not Applicable. The EUT does not operate in the 59 – 64 GHz frequency band.
(12)           The equipment is not software defined and this section is not applicable.
(13)           Applications for certification of U-NII devices in the 5.15-5.35 GHz and the 5.47-5.85
               GHz bands must include a high-level operational description of the security procedures
               that control the radio frequency operating parameters and ensure that unauthorized
               modifications cannot be made. This requirement is not applicable to his DTS device.
(14)           Contain at least one drawing or photograph showing the test set-up for each of the
               required types of tests applicable to the device for which certification is requested. These
               drawings or photographs must show enough detail to confirm other information
               contained in the test report. Any photographs used must be focused originals without
               glare or dark spots and must clearly show the test configuration used. This information is
               provided in this report and Test Setup Exhibits provided with the application filing.




Rogers Labs, Inc.                     Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                 Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                   Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214             Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                            File: A03571 DXX TstRpt 181022           Page 9 of 31


 Testing
 NVLAP Lab Code 200087-0




Applicable Standards & Test Procedures

In accordance with the e-CFR Code of Federal Regulations Title 47, dated October 22, 2018:
Part 2, Subpart J, Paragraphs 2.907, 2.911, 2.913, 2.925, 2.926, 2.1031 through 2.1057, and
applicable parts of paragraph 15, Part 15C Paragraph 15.249, Industry Canada RSS-210 Issue 9,
and RSS-GEN Issue 5 operation in the 2400 – 2483.5 MHz Frequency band. Test procedures
used are the established Methods of Measurement of Radio-Noise Emissions as described in
ANSI C63.10-2013.

Testing Procedures
AC Line Conducted Emission Test Procedure
The EUT operates on direct current power only provided by compatible DC source. Testing for the
AC line-conducted emissions was performed as defined in ANSI C63.4-2014. The test setup,
including the EUT, was arranged in the AC compatible test configuration as presented during
testing. The test configuration was placed on a 1 x 1.5-meter bench, 0.8 meters high located in a
screen room. The power lines of the system were isolated from the power source using a standard
LISN with a 50-µHy choke. EMI was coupled to the spectrum analyzer through a 0.1 µF capacitor
internal to the LISN. The LISN was positioned on the floor beneath the wooden bench supporting
the EUT. The power lines and cables were draped over the back edge of the table. Refer to diagram
one showing typical test arrangement and photographs in exhibits for EUT placement used during
testing.

Radiated Emission Test Procedure
Radiated emissions testing was performed as required in 47 CFR 15C, RSS-210 and specified in
ANSI C63.10-2013. The EUT was placed on a rotating 0.9 x 1.2-meter platform, elevated as
required above the ground plane at a distance of 3 meters from the FSM antenna. EMI energy
was maximized by equipment placement permitting orientation in three orthogonal axes, raising
and lowering the FSM antenna, changing the antenna polarization, and by rotating the turntable.
Each emission was maximized before data was taken and recorded. The frequency spectrum
from 9 kHz to 25,000 MHz was searched for emissions during preliminary investigation. Refer
to diagrams one and two showing typical test setup. Refer to photographs in the test setup
exhibits for specific EUT placement during testing.



Rogers Labs, Inc.             Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace         Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053           Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214     Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                    File: A03571 DXX TstRpt 181022           Page 10 of 31


Testing
NVLAP Lab Code 200087-0




1. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
   forth in the center forming a bundle 30 cm to 40 cm long see (see 6.2.3.1).
2. I/O cables that are not connected to an accessory shall be bundled in the center. The end of the
   cable may be terminated, if required, using the correct terminating impedance. The overall
   length shall not exceed 1 m (see 6.2.2).
3. EUT connected to one LISN. Unused LISN measuring port connectors shall be terminated in 50
   Ω loads. LISN can be placed on top of, or immediately beneath, reference ground plane (see
   6.2.2 and 6.2.3).
     3.1 All other equipment powered from additional LISN(s).
     3.2 Multiple-outlet strip can be used for multiple power cords of non-EUT equipment.
     3.3 LISN at least 80 cm from nearest part of EUT chassis.
4. Non-EUT components of EUT system being tested.
5. Rear of EUT, including peripherals, shall all be aligned and flush with rear of tabletop (see
   6.2.3.1).
6. Edge of tabletop shall be 40 cm removed from a vertical conducting plane that is bonded to the
   ground plane (see 6.2.2 for options).
7. Antenna may be integral or detachable. If detachable, the antenna shall be attached for this test.
Diagram 1 Test arrangement for Conducted emissions


Rogers Labs, Inc.             Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace         Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053           Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214     Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                    File: A03571 DXX TstRpt 181022           Page 11 of 31


Testing
NVLAP Lab Code 200087-0




1—A LISN is optional for radiated measurements between 30 MHz and 1000 MHz but not
allowed for measurements below 30 MHz and above 1000 MHz (see 6.3.1). If used, then connect
EUT to one LISN. Unused LISN measuring port connectors shall be terminated in 50 Ω loads.
The LISN may be placed on top of, or immediately beneath, the reference ground plane (see
6.2.2 and 6.2.3.2).
1.1—LISN spaced at least 80 cm from the nearest part of the EUT chassis.
2—Antenna can be integral or detachable, depending on the EUT (see 6.3.1).
3—Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
and forth in the center forming a bundle 30 cm to 40 cm long (see 6.3.1).
4—For emission measurements at or below 1 GHz, the table height shall be 80 cm. For emission
measurements above 1 GHz, the table height shall be 1.5 m for measurements, except as
otherwise specified (see 6.3.1 and 6.6.3.1).
Diagram 2 Test arrangement for radiated emissions of tabletop equipment



Rogers Labs, Inc.           Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace       Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053         Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214   Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                  File: A03571 DXX TstRpt 181022           Page 12 of 31


Testing
NVLAP Lab Code 200087-0




                                                        Appropriate
                                                        Frequency
                                                        Dependent
                                                        Antenna




                               0.8 – 1.5 m




                    AC Line Conducted Emissions (0.150 -30 MHz)
             RBW                     AVG. BW                 Detector Function
            9 kHz                      30 kHz                Peak / Quasi Peak
                             Emissions (30-1000 MHz)
             RBW                     AVG. BW                 Detector Function
           120 kHz                    300 kHz                Peak / Quasi Peak
                            Emissions (Above 1000 MHz)
             RBW                     Video BW                Detector Function
           100 kHz                    100 kHz                       Peak
            1 MHz                      1 MHz                  Peak / Average
Diagram 3 Test arrangement for radiated emissions tested on Open Area Test Site (OATS)


Test Site Locations
Conducted EMI             AC line conducted emissions testing performed in a shielded screen room
                          located at Rogers Labs, Inc., 4405 West 259th Terrace, Louisburg, KS

Radiated EMI              The radiated emissions tests were performed at the 3 meters, Open Area
                          Test Site (OATS) located at Rogers Labs, Inc., 4405 West 259th Terrace,
                          Louisburg, KS

Registered Site #         FCC Site: US5305 and Industry Canada Registration: 3041A-1

NVLAP Accreditation              Lab code 200087-0

Rogers Labs, Inc.                Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace            Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053              Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214        Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                       File: A03571 DXX TstRpt 181022           Page 13 of 31


Testing
NVLAP Lab Code 200087-0




List of Test Equipment
Equipment      Manufacturer        Model (SN)                Band        Cal Date(m/d/y) Due
☒ LISN         FCC        FCC-LISN-50-25-10(1PA) (160611) .15-30MHz        5/2/2018     5/2/2019
☒ LISN         Compliance Design FCC-LISN-2.Mod.cd,(126) .15-30MHz         10/16/2018 10/16/2019
☒ Cable        Huber & Suhner Inc. Sucoflex102ea(L10M)(303073)9kHz-40 GHz 10/16/2018 10/16/2019
☒ Cable        Huber & Suhner Inc. Sucoflex102ea(1.5M)(303069)9kHz-40 GHz 10/16/2018 10/16/2019
☐ Cable        Huber & Suhner Inc. Sucoflex102ea(1.5M)(303071)9kHz-40 GHz 10/16/2018 10/16/2019
☒ Cable        Belden              RG-58 (L1-CAT3-11509) 9kHz-30 MHz 10/16/2018 10/16/2019
☒ Cable        Belden              RG-58 (L2-CAT3-11509) 9kHz-30 MHz 10/16/2018 10/16/2019
☐ Antenna      ARA                 BCD-235-B (169)           20-350MHz     10/16/2018 10/16/2019
☐ Antenna      EMCO                3147 (40582)              200-1000MHz 10/16/2018 10/16/2019
☒ Antenna      ETS-Lindgren        3117 (200389)             1-18 GHz      5/2/2018     5/2/2020
☐ Antenna      Com Power           AH-118 (10110)            1-18 GHz      10/16/2018 10/24/2019
☒ Antenna      Com Power           AH-840 (101046)           18-40 GHz     5/15/2017 5/15/2019
☒ Antenna      Com Power           AL-130 (121055)           .001-30 MHz   10/16/2018 10/16/2019
☒ Antenna      Sunol               JB-6 (A100709)            30-1000 MHz 10/16/2018 10/16/2019
☒ Analyzer     Rohde & Schwarz ESU40 (100108)                20Hz-40GHz    5/2/2018     5/2/2019
☐ Analyzer     Rohde & Schwarz ESW44 (101534)                20Hz-44GHz    12/22/2017 12/22/2018
☐ Analyzer     Rohde & Schwarz FS-Z60, 90, 140, and 220      40GHz-220GHz 12/22/2017 12/22/2019
☒ Amplifier Com-Power              PA-010 (171003)           100Hz-30MHz 10/16/2018 10/16/2019
☒ Amplifier Com-Power              CPPA-102 (01254)          1-1000 MHz    10/16/2018 10/16/2019
☒ Amplifier Com-Power              PAM-118A (551014)         0.5-18 GHz    10/16/2018 10/16/2019
☒ Amplifier Com-Power              PAM-840A (461328)         18-40 GHz     10/16/2018 10/16/2019
☐ Power Meter Agilent              N1911A with N1921A        0.05-40 GHz   5/2/2018     5/2/2019
☐ Generator Rohde & Schwarz SMB100A6 (100150)                20Hz-6 GHz    5/2/2018     5/2/2019
☐ Generator Rohde & Schwarz SMBV100A6 (260771)               20Hz-6 GHz    5/2/2018     5/2/2019
☐ RF Filter    Micro-Tronics       BRC50722 (009).9G notch 30-1800 MHz 5/2/2018         5/2/2019
☐ RF Filter    Micro-Tronics       HPM50114 (017)1.5G HPF 30-18000 MHz 5/2/2018         5/2/2019
☐ RF Filter    Micro-Tronics       HPM50117 (063) 3G HPF 30-18000 MHz 5/2/2018          5/2/2019
☐ RF Filter    Micro-Tronics       HPM50105 (059) 6G HPF 30-18000 MHz 5/2/2018          5/2/2019
☐ RF Filter    Micro-Tronics       BRM50702 (172) 2G notch 30-1800 MHz 5/2/2018         5/2/2019
☐ RF Filter    Micro-Tronics       BRC50703 (G102) 5G notch 30-1800 MHz 5/2/2018        5/2/2019
☐ RF Filter    Micro-Tronics       BRC50705 (024) 5G notch 30-1800 MHz 5/2/2018         5/2/2019
☐ Attenuator Fairview              SA6NFNF100W-14 (1625) 30-1800 MHz 5/2/2018           5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (1735)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (1436)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (14362)          30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (1445)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-3W2+ (14452)          30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-6W2+ (1438)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator Mini-Circuits         VAT-6W2+ (1736)           30-6000 MHz 5/2/2018       5/2/2019
☐ Attenuator JFW Industries        50FH-010-10 (1)           30-18000 MHz 5/2/2018      5/2/2019
☒ Weather station Davis            6312 (A70927D44N)                       10/16/2018 10/16/2019


Rogers Labs, Inc.           Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace       Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053         Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214   Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                  File: A03571 DXX TstRpt 181022           Page 14 of 31


Testing
NVLAP Lab Code 200087-0




Units of Measurements

Conducted EMI                    Data is in dBµV; dB referenced to one microvolt

Radiated EMI                     Data is in dBµV/m; dB/m referenced to one microvolt per meter

Sample Calculation:

                          RFS = Radiated Field Strength, FSM = Field Strength Measured
                          A.F. = Receive antenna factor, Gain = amplification gains and/or cable losses
                          RFS (dBµV/m @ 3m) = FSM (dBµV) + A.F. (dB) - Gain (dB)


Environmental Conditions

Ambient Temperature                     20.5° C

Relative Humidity                       35%

Atmospheric Pressure                    1019.5 mb

Statement of Modifications and Deviations

No modifications to the EUT were required for the equipment to demonstrate compliance with
the 47 CFR Part 15C, 15.249, Industry Canada RSS-210 Issue 9, and RSS-GEN Issue 5 emission
requirements. There were no deviations to the specifications.


Intentional Radiators

The following information is submitted supporting compliance with the requirements of 47 CFR,
Subpart C, paragraph 15.249, Industry Canada RSS-210 Issue 9 and RSS-GEN Issue 5.

Antenna Requirements

The EUT incorporates integral antenna system. Production equipment offers no provision for
connection to alternate antenna system. The antenna connection point complies with the unique
antenna connection requirements. There are no deviations or exceptions to the specification.




Rogers Labs, Inc.                       Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                   Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                     Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214               Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                              File: A03571 DXX TstRpt 181022           Page 15 of 31


Testing
NVLAP Lab Code 200087-0




Restricted Bands of Operation
Spurious emissions falling in the restricted frequency bands of operation were measured at
the OATS. The EUT utilizes frequency, determining circuitry, which generates harmonics
falling in the restricted bands. Emissions were investigated at the OATS, using appropriate
antennas or pyramidal horns, amplification stages, and a spectrum analyzer. Peak and
average amplitudes of frequencies above 1000 MHz were compared to the required limits
with worst-case data presented below. Test procedures of ANSI C63.10-2013 were used
during testing. No other significant emission was observed which fell into the restricted
bands of operation. Computed emission values take into account the received radiated field
strength, receive antenna correction factor, amplifier gain stage, and test system cable losses.

Table 1 Radiated Emissions in Restricted Frequency Bands Data

       Frequency          Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
        in MHz              Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average
                                                                                                      (dBµV/m)
                          (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

         2390.0             42.4         N/A          29.8         42.7        N/A          29.8        54.0

         2483.5             49.8         N/A          30.6         50.5        N/A          30.8        54.0

         4804.0             47.6         N/A          34.2         47.0        N/A          34.0        54.0

         4884.0             47.8         N/A          34.7         47.5        N/A          34.6        54.0

         4960.0             47.3         N/A          34.3         47.5        N/A          34.3        54.0

         7206.0             50.8         N/A          38.0         51.3        N/A          38.0        54.0

         7326.0             51.0         N/A          38.2         50.7        N/A          38.0        54.0

         7440.0             50.4         N/A          37.4         49.8        N/A          37.5        54.0

        12010.0             56.0         N/A          43.1         56.6        N/A          43.0        54.0

        12210.0             58.7         N/A          45.6         58.9        N/A          45.7        54.0

        12400.0             57.0         N/A          44.9         58.0        N/A          44.9        54.0

Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded for frequency range below 1000 MHz. Peak and Average
amplitude emissions are recorded for frequency range above 1000 MHz.

Rogers Labs, Inc.                        Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                    Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                      Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214                Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                               File: A03571 DXX TstRpt 181022           Page 16 of 31


Testing
NVLAP Lab Code 200087-0




Summary of Results for Radiated Emissions in Restricted Bands
The EUT demonstrated compliance with the radiated emissions requirements of 47 CFR Part
15C and RSS-210 Intentional Radiator requirements. The EUT demonstrated a worst-case
minimum margin of -8.3 dB below the emissions requirements in restricted frequency bands.
Peak, Quasi-peak, and average amplitudes were checked for compliance with the regulations.
Worst-case emissions are reported with other emissions found in the restricted frequency
bands at least 20 dB below the requirements.

AC Line Conducted EMI Procedure
The EUT was arranged in typical AC connected configuration as defined by manufacturer. AC
Line Conducted emission testing was performed with the EUT placed on a 1 x 1.5-meter bench
80 cm above the conducting ground plane, floor of a screen room. The bench was positioned 40
cm away from the wall of the screen room. The LISN was positioned on the floor of the screen
room 80-cm from the rear of the EUT. Testing for the AC line-conducted emissions followed
the procedures of ANSI C63.10-2013. The EUT was configured as presented in the AC Line
conducted configuration as presented above in equipment configuration. The AC adapter for the
CPU powering the EUT was connected to the LISN for AC line-conducted emissions testing. A
second LISN was positioned on the floor of the screen room 80-cm from the rear of the
supporting equipment of the test configuration. All power cords except the EUT were then
powered from the second LISN. EMI was coupled to the spectrum analyzer through a 0.1 µF
capacitor, internal to the LISN. Power line conducted emissions testing was carried out
individually for each current carrying conductor of the EUT. The excess length of lead between
the system and the LISN receptacle was folded back and forth to form a bundle not exceeding 40
cm in length. The screen room, conducting ground plane, analyzer, and LISN were bonded
together to the protective earth ground. Preliminary testing was performed to identify the
frequencies of each of the emissions, which demonstrated the highest amplitudes. The cables
were repositioned to obtain maximum amplitude of measured EMI level. Once the worst-case
configuration was identified, plots were made of the EMI from 0.15 MHz to 30 MHz and data
recorded.

Refer to figures one and two for plots of the EUT – USB Computer interface AC Line conducted
emissions.


Rogers Labs, Inc.             Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace         Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053           Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214     Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                    File: A03571 DXX TstRpt 181022           Page 17 of 31


Testing
NVLAP Lab Code 200087-0




Figure 1 AC Line Conducted emissions of EUT line 1 (#3, EUT – Computer)




Figure 2 AC Line Conducted emissions of EUT line 2 (#3, EUT – Computer)


Rogers Labs, Inc.           Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace       Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053         Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214   Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                  File: A03571 DXX TstRpt 181022           Page 18 of 31


Testing
NVLAP Lab Code 200087-0




Table 2 AC Line Conducted Emissions Data L1 (#3, EUT – Computer)




Other emissions present had amplitudes at least 20 dB below the limit.

Table 3 AC Line Conducted Emissions Data L2 (#3, EUT – Computer)




Other emissions present had amplitudes at least 20 dB below the limit.

Summary of Results for AC Line Conducted Emissions
The EUT demonstrated compliance with the AC Line Conducted Emissions requirements of 47
CFR Part 15C, RSS-210 and RSS-Gen. The worst-case EUT AC conducted configuration
demonstrated a minimum margin of -10.7 dB below the requirement. Other emissions were
present with amplitudes at least 20 dB below the limit and worst-case amplitudes recorded.



Rogers Labs, Inc.            Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace        Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053          Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214    Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                   File: A03571 DXX TstRpt 181022           Page 19 of 31


Testing
NVLAP Lab Code 200087-0




General Radiated Emissions Procedure
The EUT was arranged in typical equipment configurations and operated through available
modes during testing. Preliminary testing was performed in a screen room with the EUT
positioned 1 meter from the FSM. Radiated emissions measurements were performed to identify
the frequencies, which produced the highest emissions. Each radiated emission was then
maximized at the OATS location before final radiated measurements were performed. Final data
was taken with the EUT located at the OATS at a distance of 3 meters between the EUT and the
receiving antenna. The frequency spectrum from 9 kHz to 25,000 MHz was searched for general
radiated emissions. Measured emission levels were maximized by EUT placement on the table,
rotating the turntable through 360 degrees, varying the antenna height between 1 and 4 meters
above the ground plane and changing antenna position between horizontal and vertical
polarization. Antennas used were Loop from 9 kHz to 30 MHz, Broadband Biconical from 30 to
200 MHz, Biconilog from 30 to 1000 MHz, Log Periodic from 200 MHz to 1 GHz and or double
Ridge or pyramidal horns and mixers above 1 GHz, notch filters and appropriate amplifiers and
external mixers were utilized.




Rogers Labs, Inc.                Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace            Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053              Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214        Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                       File: A03571 DXX TstRpt 181022           Page 20 of 31


Testing
NVLAP Lab Code 200087-0




Table 4 General Radiated Emissions Data
   Frequency              Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
    in MHz                  Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average
                                                                                                      (dBµV/m)
                          (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)

        40.0                34.5         30.4         N/A          36.1        32.2         N/A         40.0

        49.4                32.5         27.6         N/A          37.7        32.1         N/A         40.0

        63.5                31.5         27.0         N/A          32.2        28.2         N/A         40.0

       160.0                27.5         21.9         N/A          26.3        17.2         N/A         40.0

       217.6                27.3         19.6         N/A          22.4        16.7         N/A         40.0

       240.0                29.1         23.0         N/A          27.7        25.3         N/A         47.0

       624.0                40.8         36.3         N/A          41.8        36.9         N/A         47.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded for frequency range below 1000 MHz. Peak and Average
amplitude emissions are recorded for frequency range above 1000 MHz.

Summary of Results for General Radiated Emissions
The EUT demonstrated compliance with the radiated emissions requirements of 47 CFR Part
15C paragraph 15.209, RSS-210 and RSS-GEN Intentional Radiators. The EUT demonstrated a
minimum margin of -7.8 dB below the requirements. Other emissions were present with
amplitudes at least 20 dB below the Limits.




Rogers Labs, Inc.                          Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                      Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                        Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214                  Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                                 File: A03571 DXX TstRpt 181022           Page 21 of 31


Testing
NVLAP Lab Code 200087-0




Operation in the Band 2400 – 2483.5 MHz
The transmitter output power; harmonic and general emissions were measured on an open area
test site @ 3 meters. The EUT was placed on a turntable elevated as required above the ground
plane and at a distance of 3 meters from the FSM antenna. The peak and quasi-peak amplitude
of frequencies below 1000 MHz were measured using a spectrum analyzer. The peak and
average amplitude of frequencies above 1000 MHz were measured using a spectrum analyzer.
The amplitude of each emission was then recorded from the analyzer display. Emissions
radiated outside of the specified bands, except for harmonics, shall be attenuated by at least 50
dB below the level of the fundamental or to the general radiated emission limits, whichever is the
lesser attenuation. Antenna port emission plots were taken of transmitter performance for
reference in this and other documentation using test sample #2. The amplitude of each radiated
emission was measured on the OATS at a distance of 3 meters from the FSM antenna testing was
performed on sample representative of production with integral antenna (sample #1) with
worst-case data provided. The amplitude of each radiated emission was maximized by
equipment orientation and placement on the turn table, raising and lowering the FSM (Field
Strength Measuring) antenna, changing the FSM antenna polarization, and by rotating the
turntable. A Loop antenna was used for measuring emissions from 0.009 to 30 MHz, Biconilog
Antenna for 30 to 1000 MHz, Double-Ridge, and/or Pyramidal Horn Antennas from 1 GHz to 25
GHz. Emissions were measured in dBµV/m @ 3 meters.

Refer to figures three through six showing plots taken of the 2402-2480 MHz transmitter
operation displaying compliance with the specifications.




Rogers Labs, Inc.             Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace         Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053           Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214     Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                    File: A03571 DXX TstRpt 181022           Page 22 of 31


Testing
NVLAP Lab Code 200087-0




Figure 3 Plot of Transmitter Emissions Operation in 2402-2480 MHz




Figure 4 Plot of Transmitter Emissions 99% Occupied Bandwidth


Rogers Labs, Inc.           Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace       Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053         Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214   Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                  File: A03571 DXX TstRpt 181022           Page 23 of 31


Testing
NVLAP Lab Code 200087-0




Figure 5 Plot of Transmitter Emissions Low Band Edge




Figure 6 Plot of Transmitter Emissions High Band Edge


Rogers Labs, Inc.           Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace       Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053         Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214   Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                  File: A03571 DXX TstRpt 181022           Page 24 of 31


Testing
NVLAP Lab Code 200087-0




Transmitter Emissions Data

Table 5 Transmitter Radiated Emissions
         Frequency in     Horizontal   Horizontal   Horizontal    Vertical    Vertical     Vertical   Limit @ 3m
            MHz             Peak       Quasi-Peak    Average       Peak      Quasi-Peak    Average
                          (dBµV/m)     (dBµV/m)     (dBµV/m)     (dBµV/m)    (dBµV/m)     (dBµV/m)    (dBµV/m)


            2402.0          93.5         N/A          74.7        85.6         N/A         65.8         94.0
            4804.0          47.6         N/A          34.2        47.0         N/A         34.0         54.0
            7206.0          50.8         N/A          38.0        51.3         N/A         38.0         54.0
            9608.0          53.1         N/A          40.7        53.9         N/A         40.8         54.0
          12010.0           56.0         N/A          43.1        56.6         N/A         43.0         54.0
          14412.0           57.6         N/A          44.6        57.5         N/A         44.6         54.0
          16814.0           63.2         N/A          48.3        63.0         N/A         48.3         54.0
            2442.0          96.2         N/A          77.4        87.1         N/A         67.7         94.0
            4884.0          47.8         N/A          34.7        47.5         N/A         34.6         54.0
            7326.0          51.0         N/A          38.2        50.7         N/A         38.0         54.0
            9768.0          53.2         N/A          40.6        53.1         N/A         40.7         54.0
          12210.0           58.7         N/A          45.6        58.9         N/A         45.7         54.0
          14652.0           59.3         N/A          46.7        59.5         N/A         46.7         54.0
          17094.0           62.4         N/A          48.6        63.1         N/A         48.6         54.0
            2480.0          93.9         N/A          75.4        84.5         N/A         66.0         94.0
            4960.0          47.3         N/A          34.3        47.5         N/A         34.3         54.0
            7440.0          50.4         N/A          37.4        49.8         N/A         37.5         54.0
            9920.0          53.4         N/A          40.6        53.6         N/A         40.7         54.0
          12400.0           57.0         N/A          44.9        58.0         N/A         44.9         54.0
          14880.0           59.2         N/A          46.7        59.4         N/A         46.6         54.0
          17360.0           60.9         N/A          47.8        61.0         N/A         47.8         54.0
Other emissions present had amplitudes at least 20 dB below the limit. Peak and Quasi-Peak
amplitude emissions are recorded for frequency range below 1000 MHz. Peak and Average
amplitude emissions are recorded for frequency range above 1000 MHz.



Rogers Labs, Inc.                        Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                    Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                      Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214                Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                               File: A03571 DXX TstRpt 181022           Page 25 of 31


Testing
NVLAP Lab Code 200087-0




Summary of Results for Transmitter Radiated Emissions of Intentional Radiator

The EUT demonstrated compliance with the radiated emissions requirements of FCC 47 CFR
Part 15.249, Industry Canada RSS-210 Issue 9 and RSS-GEN Issue 5 Intentional Radiator
regulations. The EUT worst-case test sample configuration demonstrated minimum average
margin of -16.6 dB below the average emission limit for the fundamental. The EUT worst-case
configuration demonstrated minimum radiated harmonic emission margin of -5.4 dB below the
limit. No other radiated emissions were found in the restricted bands less than 20 dB below
limits than those recorded in this report. Other emissions were present with amplitudes at least
20 dB below the limits.




Rogers Labs, Inc.             Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace         Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053           Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214     Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                    File: A03571 DXX TstRpt 181022           Page 26 of 31


Testing
NVLAP Lab Code 200087-0




Annex

•     Annex A Measurement Uncertainty Calculations

•     Annex B Rogers Labs Additional Test Equipment List

•     Annex C Rogers Qualifications

•     Annex D Rogers Labs Certificate of Accreditation




Rogers Labs, Inc.              Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace          Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053            Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214      Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                     File: A03571 DXX TstRpt 181022           Page 27 of 31


Testing
NVLAP Lab Code 200087-0




Annex A Measurement Uncertainty Calculations

The measurement uncertainty was calculated for all measurements listed in this test report
according To CISPR 16–4. Result of measurement uncertainty calculations are recorded below.
Component and process variability of production devices similar to those tested may result in
additional deviations. The manufacturer has the sole responsibility of continued compliance.



                          Measurement                    Expanded Measurement
                                                            Uncertainty U(lab)

 3 Meter Horizontal 0.009-1000 MHz Measurements                    4.16

 3 Meter Vertical 0.009-1000 MHz Measurements                      4.33

 3 Meter Measurements 1-18 GHz                                     5.14

 3 Meter Measurements 18-40 GHz                                    5.16

 10 Meter Horizontal Measurements 0.009-1000 MHz                   4.15

 10 Meter Vertical Measurements 0.009-1000 MHz                     4.32

 AC Line Conducted                                                 1.75

 Antenna Port Conducted power                                      1.17

 Frequency Stability                                             1.00E-11

 Temperature                                                      1.6˚C

 Humidity                                                           3%




Rogers Labs, Inc.               Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace           Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053             Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214       Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                      File: A03571 DXX TstRpt 181022           Page 28 of 31


Testing
NVLAP Lab Code 200087-0




Annex B Rogers Labs Additional Test Equipment List
List of Test Equipment                                      Calibration   Date (m/d/y)   Due
Antenna: Schwarzbeck Model: BBA 9106/VHBB 9124 (9124-627)                 5/2/2018       5/2/2019
Antenna: Schwarzbeck Model: VULP 9118 A (VULP 9118 A-534)                 5/2/2018       5/2/2019
Antenna: EMCO 6509                                                        10/16/2018     10/16/2020
Antenna: EMCO 3143 (9607-1277) 20-1200 MHz                                5/2/2018       5/2/2019
Antenna: EMCO Dipole Set 3121C                                            2/23/2018      2/23/2019
Antenna: C.D. B-101                                                       2/23/2018      2/23/2019
Antenna: Solar 9229-1 & 9230-1                                            2/23/2018      2/23/2019
Cable: Belden 8268 (L3)                                                   10/16/2018     10/16/2019
Cable: Time Microwave: 4M-750HF290-750                                    10/16/2018     10/16/2019
Frequency Counter: Leader LDC-825 (8060153                                5/2/2018       5/2/2019
Oscilloscope Scope: Tektronix 2230                                        2/23/2018      2/23/2019
Wattmeter: Bird 43 with Load Bird 8085                                    2/23/2018      2/23/2019
R.F. Generator: SMB100A6 s/n 100623                                       5/2/2018       5/2/2019
R.F. Generator: SBMBV100A s/n: 260771                                     5/2/2018       5/2/2019
R.F. Generators: HP 606A, HP 8614A, HP 8640B                              2/23/2018      2/23/2019
R.F. Power Amp 65W Model: 470-A-1010                                      2/23/2018      2/23/2019
R.F. Power Amp 50W M185- 10-501                                           2/23/2018      2/23/2019
R.F. Power Amp A.R. Model: 10W 1010M7                                     2/23/2018      2/23/2019
R.F. Power Amp EIN Model: A301                                            2/23/2018      2/23/2019
LISN: Compliance Eng. Model 240/20                                        5/2/2018       5/2/2019
LISN: Fischer Custom Communications Model: FCC-LISN-50-16-2-08            5/2/2018       5/2/2019
Audio Oscillator: H.P. 201CD                                              2/23/2018      2/23/2019
ESD Test Set 2010i                                                        2/23/2018      2/23/2019
Oscilloscope Scope: Tektronix MDO 4104                                    2/23/2018      2/23/2019
EMC Transient Generator HVT TR 3000                                       2/23/2018      2/23/2019
AC Power Source (Ametech, California Instruments)                         2/23/2018      2/23/2019
Fast Transient Burst Generator Model: EFT/B-101                           2/23/2018      2/23/2019
Field Intensity Meter: EFM-018                                            2/23/2018      2/23/2019
KEYTEK Ecat Surge Generator                                               2/23/2018      2/23/2019
ESD Simulator: MZ-15                                                      2/23/2018      2/23/2019
Shielded Room Calibration not required



Rogers Labs, Inc.                Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace            Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053              Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214        Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                       File: A03571 DXX TstRpt 181022           Page 29 of 31


Testing
NVLAP Lab Code 200087-0




Annex C Rogers Qualifications

Scot D. Rogers, Engineer

Rogers Labs, Inc.

Mr. Rogers has approximately 27 years’ experience in the field of electronics. Engineering
experience includes six years in the automated controls industry and remaining years
working with the design, development and testing of radio communications and electronic
equipment.

Positions Held

               Systems Engineer:      A/C Controls Mfg. Co., Inc. 6 Years

               Electrical Engineer:   Rogers Consulting Labs, Inc. 5 Years

               Electrical Engineer:   Rogers Labs, Inc. Current

Educational Background

1)             Bachelor of Science Degree in Electrical Engineering from Kansas State University.

2)             Bachelor of Science Degree in Business Administration Kansas State University.

3)             Several Specialized Training courses and seminars pertaining to Microprocessors and
               Software programming.



Scot D. Rogers




Rogers Labs, Inc.                     Garmin International, Inc.               SN’s: 24361 / 24365
4405 W. 259th Terrace                 Model: A03571                            FCC ID: IPH-03571
Louisburg, KS 66053                   Test #: 181022                           IC: 1792A-03571
Phone/Fax: (913) 837-3214             Test to: 47 CFR 15.249, RSS-210, RSS-Gen Date: November 20, 2018
Revision 1                            File: A03571 DXX TstRpt 181022           Page 30 of 31


NVlad)



                            United States Department of Commerce
                        National Institute of Standards and Technology




                                    nvilad
    Certificate of Accreditation to ISO/IEC 17025:2005

                                          NVLAP LAB CODE: 200087—0

                                                Rogers Labs, Inc.
                                                     Lousburg, KS


              is accredited by the National Voluntary Laboratory Accreditation Program for specific services,
                                          listed on the Scope of Accreditation, for:

                  Electromagnetic Compatibility & Telecommunications
            This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005.
         This accreditation demonstrates technical competence for a defined scope and the operation of a laboratory quality
                        management system (refer to jfoint 1S0—ILAC—IAF Communique dated January 2009).




         2018—02—21 through 2019—03—31                                                      m ¥_NZMMn
                  Effective Dates                                           For the National Vofunt.:'l}'ty_th;aqudflcmedfmfion Program
                                                                                     Sote



Document Created: 2018-11-20 12:39:22
Document Modified: 2018-11-20 12:39:22

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC