RF Exposure Assessment

FCC ID: IPH-03562

RF Exposure Info

Download: PDF
FCCID_4069576

A03562 RF Exposure Assessment

Assessment Entity: Garmin International Inc. 1200 E. 151st Street Olathe, KS 66062 USA

Device Description: Multifunction display with WLAN and Bluetooth/ ANT transmitters

Installation type: Dashboard or Bail mounted

Exposure Type: 10‐g extremity

RF Exposure Environment: General‐Public/ Non‐Aware User

Standards applied: KDB 447498 RF EXPOSURE PROCEDURES AND EQUIPMENT AUTHORIZATION POLICIES FOR MOBILE
AND PORTABLE DEVICES

4.3.1. Standalone SAR test exclusion considerations

For 100 MHz to 6 GHz and test separation distances 50 mm, the 1‐g and 10‐g SAR test exclusion thresholds are
determined by the following: [(max. power of channel, including tune‐up tolerance, mW) / (min. test separation
distance, mm)] ∙ [√f(GHz)] 3.0 for 1‐g SAR, and 7.5 for 10‐g extremity SAR, where f(GHz) is the RF channel transmit
frequency in GHz

Calculation

 Wi‐fi Average Power            mW                               17
 Tune‐up tolerance              dBm                               0
 Separation Distance            mm                               30

 Frequency                      GHz                          2.437

 Exclusion Contribution                                        0.88


 Exclusion Limit                                                7.5
 Margin                                                        6.62


Result

The EUT meets the criteria for exclusion from SAR testing.