Test Report DXX

FCC ID: IPH-03437

Test Report

Download: PDF
FCCID_3829644

                      Engineering Solutions & Electromagnetic Compatibility Services
                                FCC Part 15.225 & Industry Canada RSS-210
                                     Certification Application Report

  Test Lab:                                                     Applicant::

  Rhein Tech Laboratories, Inc. Phone: 703-689-0368             Garmin International Inc. Phone: 913-440-5471
  360 Herndon Parkway           Fax:   703-689-2056             1200 E. 151st Street
  Suite 1400                    www.rheintech.com               Olathe, Kansas 66062
  Herndon, VA 20170                                             Contact: William Pertner
  E-Mail: atcbinfo@rheintech.com
                                IPH-03437/
  FCC/IC ID                                                     Test Report Date           April 9, 2018
                                1792A-03437
  Platform                      N/A                             RTL Work Order #           2017239
  Model/HVIN                    A03437                          RTL Quote #                QRTL17-239A
  American National             ANSI C63.10-2013: American National Standard of Procedures for
  Standard Institute            Compliance Testing of Unlicensed Wireless Devices

  FCC Classification            DXX – Part 15 Low Power Communication Device Transmitter

  FCC Rule
                                Part 15.225: Operation within the band 13.110-14.010 MHz (10-01-17)
  Part(s)/Guidance
                                RSS-210 Issue 9: Licence-Exempt Radio Apparatus: Category I Equipment
  Industry Canada               RSS-Gen: Issue 4: General Requirements for Compliance of Radio
                                Apparatus
                                                                                          Emission
  Frequency Range (MHz)            Output Power (W)         Frequency Tolerance
                                                                                         Designator
              13.56                        N/A                      N/A                   2M82A1D

I, the undersigned, hereby declare that the equipment tested and referenced in this report conforms to the
identified standard(s) as described in this test report. No modifications were made to the equipment during
testing in order to achieve compliance with these standards. Furthermore, there was no deviation from,
additions to, or exclusions from, the applicable parts of FCC Part 2, FCC Part 15, RSS-210, and ANSI
C63.10.


Signature:                                                                     Date: April 9, 2018

Typed/Printed Name: Desmond A. Fraser                                          Position: President


        These tests are accredited and meet the requirements of ISO/IEC 17025 as verified by ANAB.
                           Refer to certificate and scope of accreditation AT-1445.

         This report may not be reproduced, except in full, without the written approval of Rhein Tech
       Laboratories, Inc. and Garmin International Inc.. The test results relate only to the item(s) tested.




                              360 Herndon Pkwy | Suite 1400 | Herndon | Virginia 20170
                            Phone: 703.689.0368 | Fax: 703.689.2056 | www.rheintech.com


Rhein Tech Laboratories, Inc.                                                                                      Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                                                 Model/HVIN: A03437
Suite 1400                                                                                            Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                                                          ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                                                           Report #: 2017239DXX

                                                                Table of Contents

 1   General Information ............................................................................................................................. 5
   1.1   Scope ......................................................................................................................................... 5
   1.2   Description of EUT ...................................................................................................................... 5
   1.3   Test Facility ................................................................................................................................. 5
   1.4   Related Submittal(s)/Grant(s) ...................................................................................................... 5
   1.5   Modifications ............................................................................................................................... 5
 2 Test Information .................................................................................................................................. 6
   2.1   Description of Test Modes ........................................................................................................... 6
   2.2   Exercising the EUT...................................................................................................................... 6
   2.3   Test Result Summary .................................................................................................................. 6
   2.4   Test System Details .................................................................................................................... 6
   2.5   Configuration of Tested System................................................................................................... 7
 3 Radiated Emissions – FCC 15.209, 15.225(a) & (d); IC RSS-210 B.6; RSS-Gen.................................. 8
   3.1   Limits of Radiated Emissions Measurement................................................................................. 8
   3.2   Radiated Emissions Measurement Test Procedure ...................................................................... 8
   3.3   Radiated Emissions Test Data..................................................................................................... 9
   3.4   Radiated Emissions Harmonics/Spurious Test Data .................................................................. 10
   3.5   Radiated Emissions Digital Test Data ........................................................................................ 13
 4 AC Conducted Emissions - FCC 15.207; IC RSS-Gen 8.8: Conducted Limits.................................... 14
   4.1   Site and Test Description........................................................................................................... 14
   4.2   Test Limits................................................................................................................................. 14
   4.3   Conducted Emissions Test Data ................................................................................................ 15
 5 Occupied Bandwidth – IC RSS-Gen 6.6 ............................................................................................. 17
   5.1   99% Bandwidth Test Procedure ................................................................................................ 17
   5.2   99% Bandwidth Test Data ......................................................................................................... 17
   5.3   99% Bandwidth Plots ................................................................................................................ 18
 6 Frequency Stability – FCC 2.1055, 15.225(e): Frequency Stability; IC RSS-210 B.6 Transmitter
 Frequency Stability ................................................................................................................................... 27
   6.1   Test Procedure.......................................................................................................................... 27
   6.2   Test Data .................................................................................................................................. 27
 7 Conclusion ........................................................................................................................................ 28




                                                                                                                                     Page 2 of 31


Rhein Tech Laboratories, Inc.                                                                                 Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                                            Model/HVIN: A03437
Suite 1400                                                                                       Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                                                     ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                                                      Report #: 2017239DXX

                                                                Figure Index

 Figure 2-1:       Configuration of System Under Test .................................................................................... 7


                                                                 Table Index

 Table 2-1:        Channels Tested ................................................................................................................. 6
 Table 2-2:        Test Result Summary – FCC Part 15, Subpart C (Section 15.225) ....................................... 6
 Table 2-3:        Equipment Under Test ......................................................................................................... 6
 Table 3-1:        Radiated Emissions Test Data (Fundamental) ..................................................................... 9
 Table 3-2:        Radiated Emissions Harmonics/Spurious: TVDD 4.75V, Type A ....................................... 10
 Table 3-3:        Radiated Emissions Harmonics/Spurious: TVDD 4.75V, Type B ....................................... 10
 Table 3-4:        Radiated Emissions Harmonics/Spurious: TVDD 4.75V, Type A&B ................................... 10
 Table 3-5:        Radiated Emissions Harmonics/Spurious: TVDD 3.90V, Type A ....................................... 11
 Table 3-6:        Radiated Emissions Harmonics/Spurious: TVDD 3.90V, Type B ....................................... 11
 Table 3-7:        Radiated Emissions Harmonics/Spurious: TVDD 3.90V, Type A&B ................................... 11
 Table 3-8:        Radiated Emissions Harmonics/Spurious: TVDD 3.20V, Type A ....................................... 12
 Table 3-9:        Radiated Emissions Harmonics/Spurious: TVDD 3.20V, Type B ....................................... 12
 Table 3-10:       Radiated Emissions Harmonics/Spurious: TVDD 3.20V, Type A&B ................................... 12
 Table 3-11:       Digital Radiated Emissions Test Data ................................................................................ 13
 Table 3-12:       Radiated Emissions Test Equipment.................................................................................. 13
 Table 4-1:        Conducted Emissions Test Equipment ............................................................................... 16
 Table 5-1:        99% Bandwidth Test Data ................................................................................................. 17
 Table 5-2:        99% Bandwidth Test Equipment ........................................................................................ 26
 Table 6-1:        Temperature Frequency Stability ....................................................................................... 27
 Table 6-2:        TVDD Voltage Frequency Stability at 20°C ........................................................................ 27
 Table 6-3:        External Voltage Frequency Stability at 20°C ..................................................................... 27
 Table 6-4:        Frequency Stability Test Equipment ................................................................................... 28


                                                                  Plot Index

 Plot 4-1:     Conducted Emissions Receive – Neutral ................................................................................. 15
 Plot 4-2:     Conducted Emissions Receive - Phase ................................................................................... 15
 Plot 5-1:     99% Bandwidth – 4.75V – Type A ........................................................................................... 18
 Plot 5-2:     99% Bandwidth – 4.75V – Type B ........................................................................................... 19
 Plot 5-3:     99% Bandwidth – 4.75V – Type A&B....................................................................................... 20
 Plot 5-4:     99% Bandwidth – 3.2V – Type A ............................................................................................. 21
 Plot 5-5:     99% Bandwidth – 3.2V – Type B ............................................................................................. 22
 Plot 5-6:     99% Bandwidth – 3.2V – Type A&B......................................................................................... 23
 Plot 5-7:     99% Bandwidth – 3.9V – Type A ............................................................................................. 24
 Plot 5-8:     99% Bandwidth – 3.9V – Type B ............................................................................................. 25
 Plot 5-9:     99% Bandwidth – 3.9V – Type A&B......................................................................................... 26




                                                                                                                                 Page 3 of 31


Rhein Tech Laboratories, Inc.                                                                               Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                                          Model/HVIN: A03437
Suite 1400                                                                                     Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                                                   ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                                                    Report #: 2017239DXX

                                                            Appendix Index

 Appendix A:     Test Photographs .............................................................................................................. 29


                                                          Photograph Index

 Photograph 1:      Radiated Emissions Testing – Side View (Above 30 MHz, below 1 GHz)........................ 29
 Photograph 2:      Radiated Emissions Testing – Side View (Below 30 MHz) .............................................. 30
 Photograph 3:      Conducted Emissions Testing – Front View ................................................................... 31




                                                                                                                              Page 4 of 31


Rhein Tech Laboratories, Inc.                                                        Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                   Model/HVIN: A03437
Suite 1400                                                              Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                            ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                             Report #: 2017239DXX

 1     General Information

 1.1       Scope

 Applicable Standards:

           FCC Part 15.225: Operation within the band 13.110-14.010 MHz

           Industry Canada RSS-210: Low Power License-Exempt Communications Devices

           Industry Canada RSS-Gen: Issue 4: General Requirements for Compliance of Radio Apparatus

 1.2       Description of EUT

 Equipment Under Test              Body-worn transmitter
 Model/HVIN                        A03437
 Power Supply                      Battery operated
 Modulation Type                   ASK
 Frequency Range                   13.56 MHz
 Antenna Connector Type            Magnet Loop
 Antenna Type                      Internal

 1.3       Test Facility

 The open area test site and conducted measurement facility used to collect the radiated data is located at
 360 Herndon Parkway, Suite 1400, Herndon, Virginia 20170. This site has been fully described in a report
 and approved by the Federal Communications Commission to perform AC line conducted and radiated
 emissions testing.

 1.4       Related Submittal(s)/Grant(s)

 This is an original certification application for Garmin International Inc. Model/HVIN: A03437, FCC ID: IPH-
 03437, IC: 1792A-03437.

 1.5       Modifications

 No modifications were made to the equipment during testing in order to achieve compliance with these
 standards.




                                                                                              Page 5 of 31


Rhein Tech Laboratories, Inc.                                                           Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                      Model/HVIN: A03437
Suite 1400                                                                 Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                               ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                                Report #: 2017239DXX

 2     Test Information

 2.1     Description of Test Modes

 Table 2-1:        Channels Tested
                                              Frequency (MHz)
                                                   13.56

 2.2     Exercising the EUT

 The EUT was supplied with test firmware programmed with modulation types and rates. The EUT was
 tested in all three orthogonal planes in order to determine worst-case emissions. The EUT was provided
 with software to continuously transmit during testing. The carrier was also checked to verify that information
 was being transmitted.

 2.3     Test Result Summary

 Table 2-2:        Test Result Summary
                                                                                                    Pass/Fail
     FCC Standard           IC Standard                             Test
                                                                                                     or N/A
 FCC 15.207             RSS-Gen 8.8          AC Power Conducted Emissions                             Pass
 FCC 15.209             RSS-Gen              Radiated Emissions                                       Pass
 FCC 15.225(a), (d)     RSS-210              Field Strength of Fundamental and Harmonics              Pass
                        RSS-Gen 6.6          99% Bandwidth                                            Pass
 2.1055, 15.225(e)      RSS-210 B.6          Frequency Stability                                      Pass

 2.4     Test System Details

 The test samples were received on March 9, 2018. The FCC identifiers for all applicable equipment, plus
 descriptions of all cables used in the tested system, are identified in the following table.

 Table 2-3:        Equipment Under Test
                                                                                                          RTL
                                                           Serial                           Cable
        Part          Manufacturer         Model                            FCC ID                         Bar
                                                          Number                          Description
                                                                                                          Code
     Body-worn            Garmin
                                          A03437            509            IPH-03437          N/A         22740
     transmitter     International Inc.
     Body-worn            Garmin
                                          A03437            N/A            IPH-03437          N/A         22741
     transmitter     International Inc.




                                                                                                 Page 6 of 31


Rhein Tech Laboratories, Inc.                                     Client: Garmin Int’l Inc.
360 Herndon Parkway                                                Model/HVIN: A03437
Suite 1400                                           Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                         ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                          Report #: 2017239DXX

 2.5   Configuration of Tested System




                                               EUT




 Figure 2-1:    Configuration of System Under Test




                                                                           Page 7 of 31


Rhein Tech Laboratories, Inc.                                                        Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                   Model/HVIN: A03437
Suite 1400                                                              Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                            ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                             Report #: 2017239DXX

 3     Radiated Emissions – FCC 15.209, 15.225(a) & (d); IC RSS-210 B.6; RSS-Gen

 3.1     Limits of Radiated Emissions Measurement

          Frequency (MHz)                  Field Strength (uV/m)             Measurement Distance (m)
             0.009-0.490                        2400/f (kHz)                          300
             0.490-1.705                        2400/f (kHz)                           30
              1.705-30.0                             30                                30
                 30-88                              100                                3
                88-216                              150                                3
               216-960                              200                                3
              Above 960                             500                                3

 As shown in 15.35(b), for frequencies above 1000 MHz, the field strength limits are based on average
 detector however, the peak field strength of any emission shall not exceed the maximum permitted average
 limits specified above by more than 99% under any circumstances of modulation.

 15.225(a) states “The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed
 15,848 microvolts/meter at 30 meters.”

 20log(15,848)=84 dBuV/m at 30 m

 3.2     Radiated Emissions Measurement Test Procedure

 Before final measurements of radiated emissions were made on the open-field three/ten meter range, the
 EUT was scanned indoors at one and three meter distances. This was done in order to determine its
 emissions spectrum signature. The physical arrangement of the test system and associated cabling was
 varied in order to determine the effect on the EUT's emissions in amplitude, direction and frequency. This
 process was repeated during final radiated emissions measurements on the open-field range, at each
 frequency, in order to ensure that maximum emission amplitudes were attained.

 Final radiated emissions measurements were made on the three/ten-meter, open-field test site. The EUT
 was placed on a nonconductive turntable 0.8 meters above the ground plane. The spectrum was examined
 from 9 kHz to the 10th harmonic of the highest fundamental transmitter frequency (135.6 MHz).

 At each frequency, the EUT was rotated 360°, and the antenna was raised and lowered from 1 to 4 meters
 in order to determine the emission’s maximum level. Measurements were taken using both horizontal and
 vertical antenna polarizations. For frequencies between 30 and 1000 MHz, the spectrum analyzer’s 6 dB
 bandwidth was set to 120 kHz, and the analyzer was operated in the CISPR quasi-peak detection mode.
 For emissions above 1000 MHz, emissions are measured using the average detector function with a
 minimum resolution bandwidth of 1 MHz. No video filter less than 10 times the resolution bandwidth was
 used. The highest emission amplitudes relative to the appropriate limit were measured and recorded in this
 report.




                                                                                              Page 8 of 31


Rhein Tech Laboratories, Inc.                                                       Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                  Model/HVIN: A03437
Suite 1400                                                             Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                           ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                            Report #: 2017239DXX

 3.3     Radiated Emissions Test Data

 Table 3-1:       Radiated Emissions Test Data (Fundamental)
                                                       Site            Quasi-       Quasi-       Quasi-
           Technology Emission        Quasi-Peak
 TVDD                                              Correction           Peak        Peak          Peak
               Type      Frequency      Reading
  (V)                                                Factor          Corrected      Limit        Margin
           (A, B, A&B)      (MHz)      (dBuV/m)
                                                     (dB/m)          (dBuV/m)     (dBuV/m)        (dB)
                A           13.56        -15.4        21.0               5.6         84.0         -78.4
  4.75          B           13.56        -15.3        21.0               5.7         84.0         -78.3
              A&B           13.56        -15.3        21.0               5.7         84.0         -78.3
                A           13.56        -15.5        21.0               5.5         84.0         -78.5
   3.9          B           13.56        -15.2        21.0               5.8         84.0         -78.2
              A&B           13.56        -15.3        21.0               5.7         84.0         -78.3
                A           13.56        -15.1        21.0               5.9         84.0         -78.1
   3.2          B           13.56        -15.2        21.0               5.8         84.0         -78.2
              A&B           13.56        -15.3        21.0               5.7         84.0         -78.3

 Note:    Levels were extrapolated to 30 m from 1 m (-59.1dB)

 Part 15.225 (a), (b), and (c) state:

       The field strength of any emissions within the band 13.553–13.567 MHz shall not exceed 15,848
       microvolts/meter at 30 meters.

       Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any emissions
       shall not exceed 334 microvolts/meter at 30 meters.

       Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of any emissions
       shall not exceed 106 microvolts/meter at 30 meters.

 The 30 meter readings were interpolated from 1 meter by subtracting 40 log (30m/1m) from the field
 strength.

 The corrected measured fundamental levels in Table 3-1 are less than Part 15.225(b) and (c).




                                                                                             Page 9 of 31


Rhein Tech Laboratories, Inc.                                              Client: Garmin Int’l Inc.
360 Herndon Parkway                                                         Model/HVIN: A03437
Suite 1400                                                    Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                  ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                   Report #: 2017239DXX

 3.4     Radiated Emissions Harmonics/Spurious Test Data

 Table 3-2:      Radiated Emissions Harmonics/Spurious: TVDD 4.75V, Type A
                                          Site
        Emission       Analyzer
                                      Correction     Corrected        Limit           Margin
       Frequency       Reading
                                        Factor       (dBuV/m)       (dBuV/m)           (dB)
         (MHz)        (dBuV/m)
                                        (dB/m)
         27.12           -31.7            22.9          -8.8          29.5             -38.3
         40.68            23.7           -16.3           7.4          40.0             -32.6
         54.24            28.4           -22.1           6.3          40.0             -33.7
         67.80            30.3           -23.1           7.2          40.0             -32.8
         81.36            26.0           -21.1           4.9          40.0             -35.1
         94.92            29.2           -18.5          10.7          43.5             -32.8
         108.48           23.4           -17.1           6.3          43.5             -37.2
         122.04           24.1           -16.7           7.4          43.5             -36.1
         135.60           23.3           -17.2           6.1          43.5             -37.4

 Table 3-3:      Radiated Emissions Harmonics/Spurious: TVDD 4.75V, Type B
                                          Site
        Emission       Analyzer
                                      Correction     Corrected        Limit           Margin
       Frequency       Reading
                                        Factor       (dBuV/m)       (dBuV/m)           (dB)
         (MHz)        (dBuV/m)
                                        (dB/m)
         27.12           -29.7            22.9          -6.8          29.5             -36.3
         40.68            23.2           -16.3           6.9          40.0             -33.1
         54.24            27.3           -22.1           5.2          40.0             -34.8
         67.80            30.7           -23.1           7.6          40.0             -32.4
         81.36            26.0           -21.1           4.9          40.0             -35.1
         94.92            30.0           -18.5          11.5          43.5             -32.0
         108.48           23.4           -17.1           6.3          43.5             -37.2
         122.04           22.9           -16.7           6.2          43.5             -37.3
         135.60           23.6           -17.2           6.4          43.5             -37.1

 Table 3-4:      Radiated Emissions Harmonics/Spurious: TVDD 4.75V, Type A&B
                                          Site
        Emission       Analyzer
                                      Correction     Corrected        Limit           Margin
       Frequency       Reading
                                        Factor       (dBuV/m)       (dBuV/m)           (dB)
         (MHz)        (dBuV/m)
                                        (dB/m)
         27.12           -29.5            22.9          -6.6          29.5             -36.1
         40.68            23.8           -16.3           7.5          40.0             -32.5
         54.24            28.1           -22.1           6.0          40.0             -34.0
         67.80            31.0           -23.1           7.9          40.0             -32.1
         81.36            26.1           -21.1           5.0          40.0             -35.0
         94.92            31.4           -18.5          12.9          43.5             -30.6
         108.48           22.4           -17.1           5.3          43.5             -38.2
         122.04           22.8           -16.7           6.1          43.5             -37.4
         135.60           23.3           -17.2           6.1          43.5             -37.4



                                                                                   Page 10 of 31


Rhein Tech Laboratories, Inc.                                           Client: Garmin Int’l Inc.
360 Herndon Parkway                                                      Model/HVIN: A03437
Suite 1400                                                 Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                               ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                Report #: 2017239DXX

 Table 3-5:   Radiated Emissions Harmonics/Spurious: TVDD 3.90V, Type A
                                       Site
     Emission       Analyzer
                                   Correction     Corrected        Limit           Margin
    Frequency       Reading
                                     Factor       (dBuV/m)       (dBuV/m)           (dB)
      (MHz)        (dBuV/m)
                                     (dB/m)
      27.12           -29.8            22.9          -6.9          29.5             -36.4
      40.68            23.1           -16.3           6.8          40.0             -33.2
      54.24            28.7           -22.1           6.6          40.0             -33.4
      67.80            31.0           -23.1           7.9          40.0             -32.1
      81.36            26.3           -21.1           5.2          40.0             -34.8
      94.92            31.0           -18.5          12.5          43.5             -31.0
      108.48           22.3           -17.1           5.2          43.5             -38.3
      122.04           22.7           -16.7           6.0          43.5             -37.5
      135.60           23.5           -17.2           6.3          43.5             -37.2

 Table 3-6:   Radiated Emissions Harmonics/Spurious: TVDD 3.90V, Type B
                                       Site
     Emission       Analyzer
                                   Correction     Corrected        Limit           Margin
    Frequency       Reading
                                     Factor       (dBuV/m)       (dBuV/m)           (dB)
      (MHz)        (dBuV/m)
                                     (dB/m)
      27.12           -29.7            22.9          -6.8          29.5             -36.3
      40.68            22.9           -16.3           6.6          40.0             -33.4
      54.24            27.2           -22.1           5.1          40.0             -34.9
      67.80            31.0           -23.1           7.9          40.0             -32.1
      81.36            26.2           -21.1           5.1          40.0             -34.9
      94.92            32.3           -18.5          13.8          43.5             -29.7
      108.48           23.7           -17.1           6.6          43.5             -36.9
      122.04           23.2           -16.7           6.5          43.5             -37.0
      135.60           23.3           -17.2           6.1          43.5             -37.4

 Table 3-7:   Radiated Emissions Harmonics/Spurious: TVDD 3.90V, Type A&B
                                       Site
     Emission       Analyzer
                                   Correction     Corrected        Limit           Margin
    Frequency       Reading
                                     Factor       (dBuV/m)       (dBuV/m)           (dB)
      (MHz)        (dBuV/m)
                                     (dB/m)
      27.12           -29.9            22.9          -7.0          29.5             -36.5
      40.68            22.7           -16.3           6.4          40.0             -33.6
      54.24            27.3           -22.1           5.2          40.0             -34.8
      67.80            30.8           -23.1           7.7          40.0             -32.3
      81.36            25.9           -21.1           4.8          40.0             -35.2
      94.92            30.0           -18.5          11.5          43.5             -32.0
      108.48           22.4           -17.1           5.3          43.5             -38.2
      122.04           22.9           -16.7           6.2          43.5             -37.3
      135.60           23.5           -17.2           6.3          43.5             -37.2




                                                                                Page 11 of 31


Rhein Tech Laboratories, Inc.                                           Client: Garmin Int’l Inc.
360 Herndon Parkway                                                      Model/HVIN: A03437
Suite 1400                                                 Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                               ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                Report #: 2017239DXX

 Table 3-8:   Radiated Emissions Harmonics/Spurious: TVDD 3.20V, Type A
                                       Site
     Emission       Analyzer
                                   Correction     Corrected        Limit           Margin
    Frequency       Reading
                                     Factor       (dBuV/m)       (dBuV/m)           (dB)
      (MHz)        (dBuV/m)
                                     (dB/m)
      27.12           -30.0            22.9          -7.1          29.5             -36.6
      40.68            22.8           -16.3           6.5          40.0             -33.5
      54.24            27.7           -22.1           5.6          40.0             -34.4
      67.80            30.8           -23.1           7.7          40.0             -32.3
      81.36            25.8           -21.1           4.7          40.0             -35.3
      94.92            31.1           -18.5          12.6          43.5             -30.9
      108.48           22.3           -17.1           5.2          43.5             -38.3
      122.04           22.6           -16.7           5.9          43.5             -37.6
      135.60           23.2           -17.2           6.0          43.5             -37.5

 Table 3-9:   Radiated Emissions Harmonics/Spurious: TVDD 3.20V, Type B
                                       Site
     Emission       Analyzer
                                   Correction     Corrected        Limit           Margin
    Frequency       Reading
                                     Factor       (dBuV/m)       (dBuV/m)           (dB)
      (MHz)        (dBuV/m)
                                     (dB/m)
      27.12           -29.3            22.9          -6.4          29.5             -35.9
      40.68            23.4           -16.3           7.1          40.0             -32.9
      54.24            27.2           -22.1           5.1          40.0             -34.9
      67.80            31.1           -23.1           8.0          40.0             -32.0
      81.36            26.0           -21.1           4.9          40.0             -35.1
      94.92            30.4           -18.5          11.9          43.5             -31.6
      108.48           22.4           -17.1           5.3          43.5             -38.2
      122.04           22.6           -16.7           5.9          43.5             -37.6
      135.60           23.4           -17.2           6.2          43.5             -37.3

 Table 3-10:  Radiated Emissions Harmonics/Spurious: TVDD 3.20V, Type A&B
                                       Site
     Emission       Analyzer
                                   Correction     Corrected        Limit           Margin
    Frequency       Reading
                                     Factor       (dBuV/m)       (dBuV/m)           (dB)
      (MHz)        (dBuV/m)
                                     (dB/m)
      27.12           -29.9            22.9          -7.0          29.5             -36.5
      40.68            22.8           -16.3           6.5          40.0             -33.5
      54.24            27.5           -22.1           5.4          40.0             -34.6
      67.80            30.9           -23.1           7.8          40.0             -32.2
      81.36            26.1           -21.1           5.0          40.0             -35.0
      94.92            30.6           -18.5          12.1          43.5             -31.4
      108.48           22.6           -17.1           5.5          43.5             -38.0
      122.04           22.7           -16.7           6.0          43.5             -37.5
      135.60           23.2           -17.2           6.0          43.5             -37.5




                                                                                Page 12 of 31


   Rhein Tech Laboratories, Inc.                                                           Client: Garmin Int’l Inc.
   360 Herndon Parkway                                                                      Model/HVIN: A03437
   Suite 1400                                                                 Standards: FCC 15.225/IC RSS-210
   Herndon, VA 20170                                                               ID’s: IPH-03437/1792A-03437
   http://www.rheintech.com                                                                Report #: 2017239DXX

    3.5     Radiated Emissions Digital Test Data

    Table 3-11:        Digital Radiated Emissions Test Data
                                        Temperature: 73.9°F Humidity: 52%
                                                                       Site
Emission                Antenna    Turntable   Antenna   Analyzer                 Emission
             Test                                                   Correction                 Limit       Margin    Pass/
Frequency               Polarity   Azimuth      Height   Reading                    Level
            Detector                                                 Factor                  (dBuV/m)       (dB)      Fail
  (MHz)                  (H/V)       (deg)       (m)      (dBuV)                  (dBuV/m)
                                                                     (dB/m)
  241.0        QP          H          90         1.0       53.2       -27.6         25.6          46.0     -20.4     PASS
  391.8        QP          H          90         1.0       46.7       -23.5         23.2          46.0     -22.8     PASS
  420.0        QP          H          90         1.0       39.5       -22.5         17.0          46.0     -29.0     PASS
  574.0        QP          H          90         1.0       49.3       -19.5         29.8          46.0     -16.2     PASS
  683.5        QP          H          90         1.0       39.1       -19.3         19.8          46.0     -26.2     PASS
  691.0        QP          H          90         1.0       39.4       -19.3         20.1          46.0     -25.9     PASS
  764.0        QP          H          90         1.0       56.5       -17.9         38.6          46.0      -7.4     PASS
  774.0        QP          H          90         1.0       54.2       -17.8         36.4          46.0      -9.6     PASS
  784.0        QP          H          90         1.0       45.8       -17.8         28.0          46.0     -18.0     PASS
  794.0        QP          H          90         1.0       47.0       -18.0         29.0          46.0     -17.0     PASS
  804.0        QP          H          90         1.0       44.6       -17.9         26.7          46.0     -19.3     PASS
  814.0        QP          H          90         1.0       48.9       -17.6         31.3          46.0     -14.7     PASS

    Table 3-12:   Radiated Emissions Test Equipment
      RTL                                                                                Serial          Calibration
                Manufacturer      Model               Part Type
    Asset #                                                                             Number            Due Date
                 Rohde and                          Loop Antenna
    901663                      HFH2-Z2                                               827525/019           5/1/19
                  Schwarz                          (9 kHz-30 MHz)
                 Rhein Tech                   OATS 1 Preamplifier 40dB
    900905                       PR-1040                                                   1006           8/18/18
                Laboratories                      (30 MHz–2 GHz)
                 Rhein Tech    AM3-1197-       3 meter antenna mast,                    Outdoor             Not
    900878
                Laboratories      0005                polarizing                        Range 1           Required
                 Rhein Tech     WRT-000-                                                                    Not
    901242                                       Wood rotating table                       N/A
                Laboratories      0003                                                                    Required
                   Agilent                       Spectrum Analyzer
    901583                       N9010A                                               MY51250846           2/6/20
                Technologies                     (10 Hz–26.5 GHz)
                                                    Bilog Antenna
    900791         Chase       CBL6111B                                                    N/A            10/4/20
                                                (30 MHz–2000 MHz)
                                              EMI Receiver RF Section
    900913     Hewlett Packard   85462A                                               3325A00159           4/4/19
                                                  (9 kHz–6.5 GHz)
                                                  RF Filter Section,
    900914     Hewlett Packard   8546OA                                               3330A00107           4/4/19
                                                 (100 kHz-6.5 GHz)
      Test       Rhein Tech
                                   N/A         RTL Emission Software                       1.1              N/A
    Software    Laboratories

    Test Personnel:




               Khue N. Do                                                               March 12, 2018
              Test Engineer                            Signature                         Date of Test



                                                                                                    Page 13 of 31


Rhein Tech Laboratories, Inc.                                                       Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                  Model/HVIN: A03437
Suite 1400                                                             Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                           ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                            Report #: 2017239DXX

 4     AC Conducted Emissions - FCC 15.207; IC RSS-Gen 8.8: Conducted Limits

 4.1     Site and Test Description

 The power line conducted emissions measurements were performed in a Series 81 type shielded enclosure
 manufactured by Rayproof. The EUT was assembled on a wooden table 80 centimeters high. Power was
 fed to the EUT through a 50-ohm/50 microhenry Line Impedance Stabilization Network (LISN). The EUT
 LISN was fed power through an A.C. filter box on the outside of the shielded enclosure. The filter box and
 EUT LISN housing are bonded to the ground plane of the shielded enclosure. A second LISN, the
 peripheral LISN, provides isolation for the EUT test peripherals. This peripheral LISN was also fed A.C.
 power. A metal power outlet box, which is bonded to the ground plane and electrically connected to the
 peripheral LISN, powers the EUT host peripherals.

 The spectrum analyzer was connected to the AC line through an isolation transformer. The 50-ohm output
 of the EUT LISN was connected to the spectrum analyzer input through a Solar 100 kHz high-pass filter.
 The filter is used to prevent overload of the spectrum analyzer from noise below 100 kHz. Conducted
 emission levels were measured on each current-carrying line with the spectrum analyzer operating in the
 CISPR quasi-peak mode (or peak mode if applicable).

 The analyzer's 6 dB bandwidth was set to 9 kHz. Video filter less than 10 times the resolution bandwidth is
 not used. Average measurements are performed in linear mode using a 10 kHz resolution bandwidth, a 1
 Hz video bandwidth, and by increasing the sweep time in order to obtain a calibrated measurement. The
 emission spectrum was scanned from 150 kHz to 30 MHz. The highest emission amplitudes relative to the
 appropriate limits were measured and have been recorded.

 4.2     Test Limits

                                        Line-Conducted Emissions
                                               Limit (dBµV)
          Frequency (MHz)                      Quasi-Peak                              Average
             0.15 to 0.50                        66 to 56                              56 to 46
             0.50 to 5.00                           56                                   46
            5.00 to 30.00                           60                                   50




                                                                                            Page 14 of 31


Rhein Tech Laboratories, Inc.                                        Client: Garmin Int’l Inc.
360 Herndon Parkway                                                   Model/HVIN: A03437
Suite 1400                                              Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                            ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                             Report #: 2017239DXX

 4.3   Conducted Emissions Test Data

 Plot 4-1:      Conducted Emissions Receive – Neutral




 Plot 4-2:      Conducted Emissions Receive - Phase




                                                                             Page 15 of 31


Rhein Tech Laboratories, Inc.                                                 Client: Garmin Int’l Inc.
360 Herndon Parkway                                                            Model/HVIN: A03437
Suite 1400                                                       Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                     ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                      Report #: 2017239DXX

 Table 4-1:    Conducted Emissions Test Equipment
   RTL                                                                      Serial        Calibration
            Manufacturer    Model                Part Type
  Asset #                                                                  Number          Due Date
               Hewlett                      Spectrum Analyzer
  900968                    8567A                                        2602A00160         4/26/19
              Packard                        (10 kHz-1.5 GHz)
               Hewlett                     Quasi-Peak Adapter
  900339                   85650A                                        2521A00743         4/26/19
              Packard                          (30 Hz-1 GHz)
               Hewlett                           Spectrum
  900970                   85662A                                        2542A11239         4/26/19
              Packard                         Analyzer Display
                AFJ
  901082                     LS16                16A LISN               16010020081         2/13/21
            International
   Test       Quantum
                            TILE!7         TILE! Test Software             7.1.3.20           N/A
 Software      Change

 Test Personnel:


           Khue N. Do                                                      March 20, 2018
          Test Engineer                   Signature                         Date of Test




                                                                                      Page 16 of 31


Rhein Tech Laboratories, Inc.                                                      Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                 Model/HVIN: A03437
Suite 1400                                                            Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                          ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                           Report #: 2017239DXX

 5     Occupied Bandwidth – IC RSS-Gen 6.6

 5.1     99% Bandwidth Test Procedure

 The 99% bandwidths per RSS-Gen 6.6 were measured using a 50-ohm spectrum analyzer. The modulated
 carrier was adjusted on the analyzer so that it was displayed entirely on the spectrum analyzer. The sweep
 time was auto and allowed through several sweeps with the max hold function used in peak detector mode.

 • The transmitter shall be operated at its maximum carrier power measured under normal test conditions.
 • The span of the analyzer shall be set to capture all products of the modulation process, including the
 emission skirts.
 • The resolution bandwidth (RBW) shall be in the range of 1% to 5% of the occupied bandwidth (OBW) and
 video bandwidth (VBW) shall be approximately 3x RBW.

 Note: Video averaging is not permitted.

 5.2     99% Bandwidth Test Data

 Table 5-1:      99% Bandwidth Test Data
                        Mode                                         99% Bandwidth (MHz)
                   4.75V – Type A                                            2.8
                   4.75V – Type B                                            2.7
                  4.75V – Type A&B                                           2.8
                    3.2V – Type A                                            2.5
                    3.2V – Type B                                            2.5
                  3.2V – Type A&B                                            2.6
                    3.9V – Type A                                            2.5
                    3.9V – Type B                                            2.5
                  3.9V – Type A&B                                            2.5




                                                                                           Page 17 of 31


Rhein Tech Laboratories, Inc.                                 Client: Garmin Int’l Inc.
360 Herndon Parkway                                            Model/HVIN: A03437
Suite 1400                                       Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                     ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                      Report #: 2017239DXX

 5.3   99% Bandwidth Plots

 Plot 5-1:      99% Bandwidth – 4.75V – Type A




                                                                      Page 18 of 31


Rhein Tech Laboratories, Inc.                                 Client: Garmin Int’l Inc.
360 Herndon Parkway                                            Model/HVIN: A03437
Suite 1400                                       Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                     ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                      Report #: 2017239DXX

 Plot 5-2:      99% Bandwidth – 4.75V – Type B




                                                                      Page 19 of 31


Rhein Tech Laboratories, Inc.                                   Client: Garmin Int’l Inc.
360 Herndon Parkway                                              Model/HVIN: A03437
Suite 1400                                         Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                       ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                        Report #: 2017239DXX

 Plot 5-3:      99% Bandwidth – 4.75V – Type A&B




                                                                        Page 20 of 31


Rhein Tech Laboratories, Inc.                                Client: Garmin Int’l Inc.
360 Herndon Parkway                                           Model/HVIN: A03437
Suite 1400                                      Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                    ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                     Report #: 2017239DXX

 Plot 5-4:      99% Bandwidth – 3.2V – Type A




                                                                     Page 21 of 31


Rhein Tech Laboratories, Inc.                                Client: Garmin Int’l Inc.
360 Herndon Parkway                                           Model/HVIN: A03437
Suite 1400                                      Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                    ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                     Report #: 2017239DXX

 Plot 5-5:      99% Bandwidth – 3.2V – Type B




                                                                     Page 22 of 31


Rhein Tech Laboratories, Inc.                                  Client: Garmin Int’l Inc.
360 Herndon Parkway                                             Model/HVIN: A03437
Suite 1400                                        Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                      ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                       Report #: 2017239DXX

 Plot 5-6:      99% Bandwidth – 3.2V – Type A&B




                                                                       Page 23 of 31


Rhein Tech Laboratories, Inc.                                Client: Garmin Int’l Inc.
360 Herndon Parkway                                           Model/HVIN: A03437
Suite 1400                                      Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                    ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                     Report #: 2017239DXX

 Plot 5-7:      99% Bandwidth – 3.9V – Type A




                                                                     Page 24 of 31


Rhein Tech Laboratories, Inc.                                Client: Garmin Int’l Inc.
360 Herndon Parkway                                           Model/HVIN: A03437
Suite 1400                                      Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                    ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                     Report #: 2017239DXX

 Plot 5-8:      99% Bandwidth – 3.9V – Type B




                                                                     Page 25 of 31


Rhein Tech Laboratories, Inc.                                                  Client: Garmin Int’l Inc.
360 Herndon Parkway                                                             Model/HVIN: A03437
Suite 1400                                                        Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                      ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                       Report #: 2017239DXX

 Plot 5-9:        99% Bandwidth – 3.9V – Type A&B




 Table 5-2:        99% Bandwidth Test Equipment
    RTL                                                                      Serial        Calibration
                   Manufacturer      Model            Part Type
  Asset #                                                                   Number          Due Date
                      Agilent                     EXA Signal Analyzer
   901583                           N9010A                               MY51250846           2/6/20
                   Technologies                    (10 Hz-26.5 GHz)

 Test Personnel:



              Dan Baltzell                                                   March 27, 2018
             Test Engineer                   Signature                        Date of Test




                                                                                       Page 26 of 31


Rhein Tech Laboratories, Inc.                                                           Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                      Model/HVIN: A03437
Suite 1400                                                                 Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                               ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                                Report #: 2017239DXX

 6 Frequency Stability – FCC 2.1055, 15.225(e): Frequency Stability; IC RSS-210 B.6 Transmitter
  Frequency Stability

 6.1   Test Procedure

 The carrier frequency stability is the ability of the transmitter to maintain an assigned carrier frequency.

 15.255(e): The frequency tolerance of the carrier signal shall be maintained within ± .01% of the operating
 frequency over a temperature variation of -20°C to +50°C at normal supply voltage, and for a variation in
 the primary supply voltage from 85% to 115% of the rated supply voltage at a temperature of 20°C. For
 battery-operated equipment, the equipment tests shall be performed using a new battery.

 IC RSS-210 B.6: Carrier frequency stability shall be maintained to ±0.01% (±100 ppm).

 The EUT was evaluated over the temperature range -20°C to +50°C.

 The temperature was initially set to -20°C and a 1-hour period was observed for stabilization of the EUT.
 The frequency stability was measured within one minute after application of primary power to the
 transmitter. The temperature was raised at intervals of 10 degrees centigrade through the range. A ½-hour
 period was observed to stabilize the EUT at each measurement step and the frequency stability was
 measured within one minute after application of primary power to the transmitter. Additionally, the power
 supply voltage of the EUT was varied +/-15% nominal input voltage.

 6.2   Test Data

 Table 6-1:       Temperature Frequency Stability
         Temperature (°C)            Measured Frequency (MHz)                Percent of Operating Frequency
                  -20                         13.560000                                  0.0000
                  -10                         13.560003                                  0.0000
                   0                          13.560002                                  0.0000
                   10                         13.560002                                  0.0000
            20 (reference)                    13.560002                                  0.0000
                   30                         13.560000                                  0.0000
                   40                         13.560000                                  0.0000
                   50                         13.559994                                  0.0000

 Table 6-2:       TVDD Voltage Frequency Stability at 20°C
          Voltage (TVDD)             Measured Frequency (MHz)                Percent of Operating Frequency
                  3.2                        13.560002                                   0.0000
            3.9(reference)                   13.560000                                   0.0000
                 4.75                        13.560000                                   0.0000

 Table 6-3:       External Voltage Frequency Stability at 20°C
           Voltage (VDC)               Measured Frequency (MHz)              Percent of Operating Frequency
                 4.25                         13.560001                                  0.0000
            5 (reference)                     13.560000                                  0.0000
                 5.75                         13.560000                                  0.0000

 Results: The EUT is compliant.

                                                                                                 Page 27 of 31


Rhein Tech Laboratories, Inc.                                                      Client: Garmin Int’l Inc.
360 Herndon Parkway                                                                 Model/HVIN: A03437
Suite 1400                                                            Standards: FCC 15.225/IC RSS-210
Herndon, VA 20170                                                          ID’s: IPH-03437/1792A-03437
http://www.rheintech.com                                                           Report #: 2017239DXX

 Table 6-4:         Frequency Stability Test Equipment
   RTL                                                                            Serial       Calibration
                      Manufacturer         Model              Part Type
  Asset #                                                                        Number         Due Date
                                                            Temperature
                        Tenney
     900946                                TH65               Chamber             11380          3/26/19
                    Engineering, Inc.
                                                            with Humidity
                        Agilent                          EXA Signal Analyzer
     901583                               N9010A                               MY51250846         2/6/20
                     Technologies                         (10 Hz-26.5 GHz)
     901672         Rohde&Schwarz         FSEM30          Spectrum Analyzer    1079.8500.30      4/17/19
     901627           Meterman            34XR-A             Multimeter         040402802        4/19/18
       N/A          Hewlett Packard        6024A          DC Power Supply      1912A00331          N/A

 Test Personnel:



              Daniel Baltzell                                                     March 28, 2018
              Test Engineer                       Signature                       Date of Tests


 7     Conclusion

 The data in this measurement report shows that the EUT as tested, Garmin International Inc. Model/HVIN
 A03437, FCC ID: IPH-03437, IC: 1792A-03437, complies with the applicable requirements of Parts 2 and
 15 of the FCC Rules and Regulations, and IC RSS-210 and RSS-Gen.




                                                                                           Page 28 of 31



Document Created: 2018-04-13 16:07:53
Document Modified: 2018-04-13 16:07:53

© 2024 FCC.report