RFx Report

FCC ID: IPH-03433

RF Exposure Info

Download: PDF
FCCID_4312316

                                                      RF Exposure Evaluation


Reference:      CFR 47 FCC Part 1.1310
                RSS-102. Issue 5

Description:   All transmitters in the device have the possibility of transmitting simultaneously. The worst-case exposure for
each transmitter was used to calculate the percentage of the allowable limit that each transmitter contributed. All of the
percentages were then added together to verify that at the specified operating distance, they were below the allowable limit.

All measurements were peak or RMS power readings taken from test reports from accredited test labs. Antenna gains were
taken from the manufacturer’s specifications.

Limits:         Maximum exposure limits from CFR 47, FCC Part 1.1310:

                                     Table 1 - Limits for Maximum Permissible Exposure (MPE)

   Frequency range          Electric field strength        Magnetic field strength        Power density       Averaging time
        (MHz)                        (V/m)                         (A/m)                    (mW/cm2)            (minutes)
                                       (A) Limits for Occupational/Controlled Exposure
0.3-3.0                                           614                             1.63                *100                        6
3.0-30                                          1842/f                           4.89/f             *900/f2                       6
30-300                                            61.4                           0.163                  1.0                       6
300-1,500                                                                                             f/300                       6
1,500-100,000                                                                                             5                       6
                                  (B) Limits for General Population/Uncontrolled Exposure
0.3-1.34                                          614                             1.63                *100                       30
1.34-30                                          824/f                           2.19/f             *180/f2                      30
30-300                                            27.5                           0.073                  0.2                      30
300-1,500                                                                                            f/1500                      30
1,500-100,000                                                                                           1.0                      30




                                                           Page 1 of 4


                                                     RF Exposure Evaluation

 Occupational/Controlled                             0
 General Population/uncontrolled                     1


                                                   Power
                                                   (conducted)                              Limit at
                       Antenna         Power       +10% for    Power                        specified
 Transmitter Frequency Gain            (conducted) tolerance   Density                      distance     % of limit   Add     Total

                MHz          numerical mW                mW            mW/cm^2 mW/cm^2
            1         2412         1              635           698.50  0.13903    1.00                      13.90%        1 13.90%
            2         2402         1                 5            5.50  0.00109    1.00                       0.11%        1  0.11%
                                                                                                                      TOTAL 14.01%

 Distance              20 cm                                                                                          PASS?   YES



                                   Table 2 - Calculations according to CFR 47, Part 1.1310, Table 1(B)

When measurements were performed as EIRP, the antenna gain is listed as 1. In cases where the antenna gain is not
listed as 1, the power measurement was performed as conducted and the antenna gain from the manufacturer’s
datasheet was used.

The power density is calculated as shown below:

       S = (P x G)/(4 x π x d^2) – used to calculate exposure at 20 cm

       d = √(S/(P x G) x 4 X π) – used to calculate minimum distance to meet limits

       1 mW/cm^2 = 10 W/m^2




                                                             Page 2 of 4


                                                    RF Exposure Evaluation

Using RSS-102, Issue 5, Section 2.5.2

   RF exposure evaluation is required if the separation distance between the user and/or bystander and the device’s radiating
                          element is greater than 20 cm, except when the device operates as follows:

 • below 20 MHz6 and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less than 1 W (adjusted for
                                                   tune-up tolerance);

 • at or above 20 MHz and below 48 MHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less
                             than 4.49/ƒ0.5 W (adjusted for tune-up tolerance), where ƒ is in MHz;

• at or above 48 MHz and below 300 MHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less
                                      than 0.6 W (adjusted for tune-up tolerance);

 • at or above 300 MHz and below 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less
                      than 1.31 x 10-2 ƒ^(0.6834) W (adjusted for tune-up tolerance), where ƒ is in MHz;

• at or above 6 GHz and the source-based, time-averaged maximum e.i.r.p. of the device is equal to or less than 5 W (adjusted for
                        tune-up tolerance). In these cases, the information contained in the RF exposure




                                                           Page 3 of 4


                                               RF Exposure Evaluation




                                                            Power
                                                            EIRP +10%
                                         Antenna   Power    for
                Transmitter Frequency    Gain      EIRP     tolerance Limit   Result
                            MHz          numerical W                   W
                          1 2412 – 2462          1    0.635      0.695  2.684          Exempt
                          2  2402 - 2480         1    0.005      0.006  2.676          Exempt




*Antenna gain was set to 1 because power levels were based off of EIRP values

10% was added to account for power tolerance




                                                    Page 4 of 4



Document Created: 2019-06-10 08:55:16
Document Modified: 2019-06-10 08:55:16

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC