Test report

FCC ID: INWP7

Test Report

Download: PDF
FCCID_977135

                                                         Test report          Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                     Page: 1 of 27




                                                    Test report
                                                        for
                                                     WindLink



                     Report Date:                  July 2, 2008



                     Signatures:




                     Tested by:
                                                   ________________
                                                   Päivi Punta           Testing engineer




                     Contents approved:            ________________
                                                   Petri Lehtinen        Operational manager




Test results are valid for the tested unit only.                              The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                  Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                                 Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                      Email: firstname.lastname@intertek.com


                                                                              Test report                                Identification: T08-606C-EMC
                                                                   Product compliance test
                                                                    EMC-measurements                                                                       Page: 2 of 27


CONTENTS
1       LABORATORY INFORMATION .................................................................................................................................... 3
2       CUSTOMER INFORMATION.......................................................................................................................................... 3
3       SUMMARY OF TEST RESULTS ..................................................................................................................................... 4
4       EUT INFORMATION......................................................................................................................................................... 5
     4.1         EUT description ......................................................................................................................................... 5
     4.2         EUT TEST SETUPS.................................................................................................................................. 6
5       APPLICABLE STANDARDS............................................................................................................................................. 6
6       FIELD STRENGTH OF FUNDAMENTAL ..................................................................................................................... 7
     6.1         Test setup and measurement method ......................................................................................................... 7
     6.2         EUT operation mode.................................................................................................................................. 7
     6.3         Limit........................................................................................................................................................... 7
     6.4         Results........................................................................................................................................................ 7
7       RADIATED SPURIOUS EMISSIONS .............................................................................................................................. 8
     7.1         Test setup ................................................................................................................................................... 8
     7.2         Test method................................................................................................................................................ 9
     7.3         EUT operation mode.................................................................................................................................. 9
     7.4         Limit........................................................................................................................................................... 9
     7.5         Results...................................................................................................................................................... 10
8       20 dB BANDWIDTH ......................................................................................................................................................... 13
     8.1         Test setup and measurement method ....................................................................................................... 13
     8.2         EUT operation mode................................................................................................................................ 13
     8.3         Results...................................................................................................................................................... 14
     8.4         Screen shots ............................................................................................................................................. 14
9       99 % BANDWIDTH .......................................................................................................................................................... 16
     9.1         Test setup and measurement method ....................................................................................................... 16
     9.2         EUT operation mode................................................................................................................................ 16
     9.3         Results...................................................................................................................................................... 17
     9.4         Screen shots ............................................................................................................................................. 17
10      CONDUCTED EMISSIONS TO AC-MAINS................................................................................................................. 19
     10.1        Test setup ................................................................................................................................................. 19
     10.2        EUT operation mode................................................................................................................................ 19
     10.3        Limits ....................................................................................................................................................... 19
     10.4        Results...................................................................................................................................................... 20
     10.5        Screen shots ............................................................................................................................................. 21
11      RECEIVER RADIATED EMISSION.............................................................................................................................. 22
     11.1        Test setup ................................................................................................................................................. 22
     11.2        Test method.............................................................................................................................................. 23
     11.3        EUT operation mode................................................................................................................................ 23
     11.4        Limit......................................................................................................................................................... 23
     11.5        Results...................................................................................................................................................... 24
12      TEST EQUIPMENT.......................................................................................................................................................... 26
     12.1        Conducted measurements......................................................................................................................... 26
     12.2        Radiated measurements............................................................................................................................ 26
13      TEST SETUP PHOTOGRAPHS ..................................................................................................................................... 27




Test results are valid for the tested unit only.                                                                          The report may be copied only in its entireness

Intertek ETL Semko Oy                                                  Business ID                                                            Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                                           FI 1871439-4                                                           Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                                                                  Email: firstname.lastname@intertek.com


                                                         Test report             Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                        Page: 3 of 27


1      LABORATORY INFORMATION

                     Test Laboratory                      INTERTEK ETL SEMKO OY
                                                          EMC Laboratory
                                                          Koneenkatu 12 / K17
                                                          05830 Hyvinkää
                                                          FINLAND

                                                          Tel: +358 10 424 6200
                                                          Fax: +358 10 424 6201
                                                          e-mail: firstname.surname@intertek.com

                     FCC registration                     910391 (January 27, 2003)
                     number:                              IC 4616A-1 (May 14, 2003)
                     IC file number:


2      CUSTOMER INFORMATION

                     Client                               Polar Elektro Oy
                                                          Professorintie 5
                                                          90440 Kempele
                                                          Finland

                                                          Tel. +358 8 520 2100
                                                          Fax +358 8 520 2200
                     Contact person:                      Jouni savolainen
                                                          Polar Elektro Oy
                                                          Professorintie 5
                                                          90440 Kempele
                                                          Finland

                                                          Tel: +358 8 520 2100
                                                          Fax: +358 8520 2200
                     Testing date:                        April 23 – June 04, 2008
                     Report date:                         July 02, 2008

                     The tests listed in this report have been done to demonstrate compliance to the FCC
                     rules section CFR47 §15.249, §15.209 and IC standard RSS-GEN, RSS-210.




Test results are valid for the tested unit only.                                 The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                    Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                                   Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                        Email: firstname.lastname@intertek.com


                                                             Test report             Identification: T08-606C-EMC
                                                       Product compliance test
                                                        EMC-measurements                                        Page: 4 of 27


3      SUMMARY OF TEST RESULTS

                     Transmitter measurements
                    Section in       Section in RSS-                    Test                                          Result
                    CFR 47           210
                    § 15.249 (a)     A2.9                               Field strength of fundamental                 PASS
                    § 15.249 (a) (d) 2.7, A2.9                          Spurious radiated emissions                   PASS
                    § 15.215 (c)                                        20 dB bandwidth                               PASS
                                     RSS-GEN 4.4.1                      99% bandwidth                                 PASS

                     Receiver measurements
                     Section in Section in Section in                   Test                                          Result
                      CFR 47 RSS-GEN ICES-003
                      §15.107     7.2.2       5.3                       Conducted emissions to AC-                    PASS
                                                                        power lines
                       §15.109                 7.2.3          5.5       Radiated emissions                            PASS

                     PASS           Pass
                     FAIL           Fail
                     X              Measured, but there is no applicable performance criteria
                     Na             Not applicable




Test results are valid for the tested unit only.                                     The report may be copied only in its entireness

Intertek ETL Semko Oy                                    Business ID                                    Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                             FI 1871439-4                                   Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                            Email: firstname.lastname@intertek.com


                                                           Test report               Identification: T08-606C-EMC
                                                     Product compliance test
                                                      EMC-measurements                                          Page: 5 of 27


4      EUT INFORMATION

                     The EUT and accessories used in the tests are listed below. Later in this report only
                     EUT numbers are used as reference.

                                            Device            Type             S/N                                 EUT
                                                                                                                   numbe
                                                                                                                   r
                                            W.I.N.D           WindLink         F821P70300034**                     60601
                                            2,4GHz USB-
                    EUT                     Dongle
                                            W.I.N.D           WindLink         F821P70300035***                    60602
                                            2,4GHz USB-
                                            Dongle
                                            W.I.N.D           WindLink         F821P70300032***                    60603
                                            2,4GHz USB-
                                            Dongle

                                            Portable          DELL             -                                   60604
                    Accessories
                                            computer
                                            Printer           HP               -                                   60605
                                            Mouse             Compaq           -                                   60606
                     Notes:
                     **     Modified to transmit continuously
                     ***    Modified with antenna connector for conducted measurements


4.1      EUT description

                     EUT is a USB dongle for transferring data between Polar wrist computers and PC.
                     The data transfer is conducted using radio link operating in 2.4GHz frequency
                     band.

                     The EUT was not modified during the tests.




Test results are valid for the tested unit only.                                     The report may be copied only in its entireness

Intertek ETL Semko Oy                                  Business ID                                      Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                           FI 1871439-4                                     Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                            Email: firstname.lastname@intertek.com


                                                         Test report         Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                    Page: 6 of 27



4.2      EUT TEST SETUPS

                     For each test the EUT was exercised to find out the worst case of operation modes
                     and device configuration.

                     Two different test setups were used: one for conducted measurements, another for
                     radiated measurements. Two EUT were equipped with an external antenna
                     connector for conductive measurements.

                     The test setup photographs are in the document referenced in section 13.


5      APPLICABLE STANDARDS

                     The tests were performed in guidance of:

                     CFR 47 part:
                            §15.107
                            §15.109
                            §15.209
                            §15.249
                            ANSI C63.4, 2003

                     IC standard:
                             RSS-GEN, Issue 1
                             RSS-210, Issue 7
                             ICES-003, Issue 4
                             CISPR 22, 2002

                     Deviations, modifications or clarifications (if any) to above mentioned documents
                     are written in each section under "Test method" for each test case.




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                               Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                    Email: firstname.lastname@intertek.com


                                                                Test report                 Identification: T08-606C-EMC
                                                          Product compliance test
                                                           EMC-measurements                                            Page: 7 of 27


6      FIELD STRENGTH OF FUNDAMENTAL

                       EUT                                  60601
                       Accessories                          60604
                       Temp, Humidity,                      26 ºC                     27 RH%                         1001 hPa
                       Air Pressure
                       Date of measurement                  May 29, 2008
                       FCC rule part                        §15.249 (a)
                       RSS-210 section                      A2.9 (1)
                       Measured by                          Päivi Punta

6.1      Test setup and measurement method

                     The EUT was set on a non-conductive turntable in a semi-anechoic chamber.
                     The EUT was set at 0.8m height. Measuring antenna was scanned 1 – 4 m in
                     height.
                     The measurements were repeated in three EUT orientations and two antenna
                     polarizations.
                     The measured signal was routed from the measuring antenna to the spectrum
                     analyzer.
                     The measurement was made using 1 MHz resolution bandwidth and 1 MHz video
                     bandwidth and maximum hold function to record the maximum peak output power.

6.2      EUT operation mode

                       EUT operation mode                   Continuous transmission
                       EUT frequency                        2402, 2440, 2481 MHz
                       EUT TX power level                   0 dBm (Software configuration)

6.3      Limit

         Table 1: Field strength of fundamental
                     Frequency (MHz)                                    mV/m ( @3m)                    dBuV/m ( @3m)
                         2400-2483.5                                      50 (Avg)                    94 (Avg) 114 (peak)

6.4      Results
         Table 2:              Maximum field strength of fundamental (Peak value)
             Freq         Measured           Correction         Result           EUT        Antenna        Antenna         Turntable
             MHz           Value              Factor           dBuV/m         orientation     Pol.          height           angle
                           dBuV                 dB                                                            m               deg
            2401             59,1                  33,7          92,8           Pos 1         Hor              1,0             211
            2440             60,1                  33,9          94,0           Pos 3         Hor              1,0             336
            2481             58,3                  34,1          92,4           Pos 2         Hor              1,7             173



Test results are valid for the tested unit only.                                            The report may be copied only in its entireness

Intertek ETL Semko Oy                                       Business ID                                        Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                                FI 1871439-4                                       Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                                   Email: firstname.lastname@intertek.com


                                                                     Test report                                Identification: T08-606C-EMC
                                                          Product compliance test
                                                           EMC-measurements                                                                Page: 8 of 27


7       RADIATED SPURIOUS EMISSIONS

                       EUT                                    60601
                       Accessories                            60604
                       Temp, Humidity,                        26 ºC                                    27 RH%                           1001 hPa
                       Air Pressure
                       Date of measurement                    May 29, 2008
                       FCC rule part                          §15.249 (a) (d)
                       RSS-210 section                        2.7, A2.9 (2)
                       Measured by                            Päivi Punta

7.1      Test setup

                     EUT was modified to send constant carrier at nominal frequency.

                     The test was done using an automated test system, where a computer controlled the
                     measurement equipments.


                      SHIELDED ANECHOIC ROOM        MEASUREMENT ANTENNA        4.0 m
                                                                                       NOTCH       PRE-
                                                                                       FILTER      AMPLIFIER
                         EUT
                                                                                                                      SPECTRUM
                                                                                                                      ANALYZER




                                                                     1.0 m
                                            3.0 m




                     Picture 1:            Test setup for radiated spurious emissions measurement
                                           30 MHz - 3 GHz frequencies

                      SHIELDED ANECHOIC ROOM
                                                      MEASUREMENT     4.0 m   HIGH PASS
                                                                                                PRE-AMPLIFIER
                                                        ANTENNA                 FILTER

                         EUT
                                                                                                                       SPECTRUM
                                                                                                                       ANALYZER




                                                             1.0 m
                                            1.0 m




                     Picture 2:            Test setup for radiated spurious emissions measurement
                                           3 GHz – 25 GHz frequencies




Test results are valid for the tested unit only.                                                                The report may be copied only in its entireness

Intertek ETL Semko Oy                                        Business ID                                                           Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                                 FI 1871439-4                                                          Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                                                       Email: firstname.lastname@intertek.com


                                                          Test report           Identification: T08-606C-EMC
                                                    Product compliance test
                                                     EMC-measurements                                      Page: 9 of 27



7.2      Test method

                           1. The emissions were searched and maximized by moving the turntable,
                              changing the measuring antenna polarization and height and manipulating
                              the EUT.
                           2. Levels of suspicious signals and levels of EUT transmitter harmonics were
                              recorded.
                           3. The recorded levels were corrected in the automated test system with the
                              measurement antenna factor, cable attenuations and filter attenuation.
                           4. The corrected values, giving the EUT radiated spurious emission levels as
                              dBµV/m at 3 m distance, are reported.

7.3      EUT operation mode

                       EUT operation mode             Continuous transmission
                       EUT frequency                  2402,2440, 2481 MHz
                       EUT TX power level             0 dBm (Software configuration)

7.4      Limit

                     Table 3:              Radiated spurious emission limits at measurement distance of 3m
                       Frequency band                 3m Limit           3m Limit                   Detector
                            (MHz)                      (µV/m)            (dBµV/m)
                            30 – 88                      100                 40                        QP
                            88 -216                      150                43.5                       QP
                           216 - 960                     200                 46                        QP
                          960 - 1000                     500                54.0                       QP
                        1000 - 25000                     500                54.0                      AVG
                        1000 - 25000                    5000                74.0                      PEAK

                     As default, all emissions were compared against the general limits. If any emission
                     exceeded that limit, it was further checked, that it complies with the -50dBc
                     requirement.




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

Intertek ETL Semko Oy                                 Business ID                                  Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                          FI 1871439-4                                 Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                       Email: firstname.lastname@intertek.com


                                                                Test report               Identification: T08-606C-EMC
                                                          Product compliance test
                                                           EMC-measurements                                        Page: 10 of 27


7.5      Results

                     Measurement system noise level was least 20 dB below the spurious emission
                     limit. Only levels of suspicious signals and transmitter harmonic frequencies,
                     which were above the measurement system noise, are reported.

Table 4:             Emission levels PEAK detector
          Freq            Measured           Correction         Result        Marginal    EUT            Ant        Ant          TT
          MHz              Value              Factor           dBuV/m         dBuV/m     Position        Pol.      height       angle
                           dBuV                 dB
          7206               51,5                  -3,8          47,7          -26,3     Pos 2          Ver          1.1         260




Test results are valid for the tested unit only.                                          The report may be copied only in its entireness

Intertek ETL Semko Oy                                       Business ID                                      Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                                FI 1871439-4                                     Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                                 Email: firstname.lastname@intertek.com


                                                         Test report         Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                  Page: 11 of 27


Spurious emissions on band edge restricted bands




            Picture 3:              Band edge measurement, Average




            Picture 4:              Band edge measurement, Peak




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                               Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                    Email: firstname.lastname@intertek.com


                                                         Test report         Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                  Page: 12 of 27




            Picture 5:              Band edge measurement, Average




            Picture 6:              Band edge measurement, Peak




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                               Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                    Email: firstname.lastname@intertek.com


                                                         Test report            Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                     Page: 13 of 27


8       20 dB BANDWIDTH

                       EUT                           60602
                       Accessories                   60604
                       Temp, Humidity,               21 ºC                   49 RH%                     992 hPa
                       Air Pressure
                       Date of measurement           June 23, 2008
                       FCC rule part                 §15.215 (c)
                       RSS-210 section
                       Measured by                   Päivi Punta


8.1      Test setup and measurement method

                     The 20dB bandwidth was measured using 10 kHz resolution bandwidth and
                     maximum hold function of the spectrum analyzer. 20dB bandwidth was defined by
                     measuring the maximum level on the measured channel and by placing display line
                     20 dB below this value and by reading the bandwidth from the intersection of the
                     measured trace and display line.


8.2      EUT operation mode

                       EUT operation mode            Normal modulation
                       EUT frequency                 2402, 2440, 2481 MHz
                       EUT TX power level            0 dBm (Software configuration)




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                   Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                                  Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                       Email: firstname.lastname@intertek.com


                                                         Test report            Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                     Page: 14 of 27


8.3      Results
                     Table 5:              20dB bandwidth measurement results
                                EUT Frequency                          Limit                   Measured value
                                    MHz                                MHz                         MHz
                                    2402                                 -                         1.80
                                    2440                                 -                         2.03
                                    2481                                 -                         2.01



8.4      Screen shots




                     Picture 7:            20dB Bandwidth measurement result, 2402




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                   Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                                  Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                       Email: firstname.lastname@intertek.com


                                                         Test report          Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                   Page: 15 of 27




                     Picture 8:            20dB Bandwidth measurement result, 2440




                     Picture 9:            20dB Bandwidth measurement result, 2481




Test results are valid for the tested unit only.                              The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                 Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                                Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                     Email: firstname.lastname@intertek.com


                                                         Test report            Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                     Page: 16 of 27


9      99 % BANDWIDTH

                       EUT                           60602
                       Accessories                   60604
                       Temp, Humidity,               21 ºC                   49 RH%                     992 hPa
                       Air Pressure
                       Date of measurement           June 23, 2008
                       FCC rule part
                       RSS-GEN section               4.4.1
                       Measured by                   Marko Turkkila, Päivi Punta


9.1      Test setup and measurement method

                     The 99% occupied bandwidth was calculated from spectrum analyzer
                     measurements.
                     The measurement data was read from the analyzer to computer.
                     Software in computer calculated the total power from the measurement data and
                     defined the frequency band containing 99% of the total power.
                     Markers in the spectrum analyzer were then placed between the calculated
                     frequencies to show the calculated 99% power band in the screenshots.


9.2      EUT operation mode

                       EUT operation mode            Normal modulation
                       EUT frequency                 2402, 2440, 2481 MHz
                       EUT TX power level            0 dBm (Software configuration)




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                   Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                                  Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                       Email: firstname.lastname@intertek.com


                                                         Test report           Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                    Page: 17 of 27


9.3      Results
                     Table 6:              99% bandwidth measurement results
                                EUT Frequency                          Limit                  Measured value
                                    MHz                                MHz                        MHz
                                    2402                                 -                        1,996
                                    2440                                 -                        1,996
                                    2481                                 -                        1.987


9.4      Screen shots




                     Picture 10:           99% Bandwidth measurement result 2402MHz




Test results are valid for the tested unit only.                               The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                  Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                                 Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                      Email: firstname.lastname@intertek.com


                                                         Test report         Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                  Page: 18 of 27




                     Picture 11:           99% Bandwidth measurement result, 2440MHz




                     Picture 12:           99% Bandwidth measurement result, 2481MHz




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                               Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                    Email: firstname.lastname@intertek.com


                                                         Test report         Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                  Page: 19 of 27



10 CONDUCTED EMISSIONS TO AC-MAINS

                       EUT                           60601
                       Accessories                   60604, 60605, 60606
                       Temp, Humidity,               22 ºC               45 RH%                      997 hPa
                       Air Pressure
                       Date of measurement           June 27, 2008
                       FCC rule part                 §15.107
                       RSS-GEN section               7.2.2
                       ICES-003 section              5.3
                       Measured by                   Päivi Punta

10.1 Test setup

                     Charger was connected to line impedance stabilization network and conducted
                     emissions to AC-mains were measured using measurement receiver.


10.2 EUT operation mode

                     EUT was connected to portable computer USB connector. Transmitter was set to
                     receiver active mode.


10.3 Limits

                                                                         FCC / IC
                           Frequency of emission              Limit                      Limit
                                  [MHz]                      [dBμV]                     [dBμV]
                                                           Quasi peak                  Average
                              0,15 – 0,50                   66 – 56*                   56 – 46*
                                0,50 – 5                       56                         46
                                 5 – 30                        60                         50
                     * The limit decreases linearly with the logarithm of the frequency




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                               Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                    Email: firstname.lastname@intertek.com


                                                          Test report            Identification: T08-606C-EMC
                                                    Product compliance test
                                                     EMC-measurements                                     Page: 20 of 27



10.4 Results

                     The measured interference values using peak and average detectors are shown in
                     the pictures 3 and 4 below.
                     All signals closer than 6 dB to the limit have been measured using quasi peak and
                     average detectors and reported in the table 7 and 8.

                     Table 7:              Quasi peak detector measurement results, AC live
                             Frequency             Measured value              Limit               Margin to limit
                               [MHz]                  [dBμV]                  [dBμV]                   [dB]
                                N/A

                     Table 8:              Average detector measurement results, AC live
                             Frequency             Measured value              Limit               Margin to limit
                               [MHz]                  [dBμV]                  [dBμV]                   [dB]
                                N/A

                     Table 9:              Quasi peak detector measurement results, AC neutral
                             Frequency             Measured value              Limit               Margin to limit
                               [MHz]                  [dBμV]                  [dBμV]                   [dB]
                                N/A

                     Table 10:             Average detector measurement results, AC neutral
                             Frequency             Measured value              Limit               Margin to limit
                               [MHz]                  [dBμV]                  [dBμV]                   [dB]
                                N/A




Test results are valid for the tested unit only.                                 The report may be copied only in its entireness

Intertek ETL Semko Oy                                 Business ID                                   Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                          FI 1871439-4                                  Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                        Email: firstname.lastname@intertek.com


                                                               Test report          Identification: T08-606C-EMC
                                                         Product compliance test
                                                          EMC-measurements                                   Page: 21 of 27


10.5 Screen shots




                     Picture 13:           AC-mains conducted emission measurement results, AC live




                     Picture 14:                   AC-mains conducted emission measurement results, AC neutral




Test results are valid for the tested unit only.                                    The report may be copied only in its entireness

Intertek ETL Semko Oy                                      Business ID                                 Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                               FI 1871439-4                                Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                           Email: firstname.lastname@intertek.com


                                                                     Test report                      Identification: T08-606C-EMC
                                                          Product compliance test
                                                           EMC-measurements                                                    Page: 22 of 27


11 RECEIVER RADIATED EMISSION

                       EUT                                    60601
                       Accessories                            60604, 60605, 60606
                       Temp, Humidity,                        25 ºC               29 RH%                                      1001 hPa
                       Air Pressure
                       Date of measurement                    June 2, 2008
                       FCC rule part                          §15.109
                       RSS-GEN section                        7.2.3
                       ICES-003 section                       5.5
                       Measured by                            Päivi Punta

11.1 Test setup

                     The test was done using an automated test system, where a computer controlled the
                     measurement equipments.


                      SHIELDED ANECHOIC ROOM        MEASUREMENT ANTENNA       4.0 m

                                                                                      PRE-AMPLIFIER
                         EUT
                                                                                                            SPECTRUM
                                                                                                            ANALYZER




                                                                     1.0 m
                                            3.0 m




                     Picture 15:           Test setup for radiated spurious emissions measurement
                                           30 MHz - 1 GHz frequencies

                      SHIELDED ANECHOIC ROOM
                                                      MEASUREMENT     4.0 m
                                                        ANTENNA                PRE-AMPLIFIER

                         EUT
                                                                                                             SPECTRUM
                                                                                                             ANALYZER




                                                             1.0 m
                                            1.0 m




                     Picture 16:           Test setup for radiated spurious emissions measurement
                                           1 GHz – 12.4 GHz frequencies




Test results are valid for the tested unit only.                                                      The report may be copied only in its entireness

Intertek ETL Semko Oy                                        Business ID                                                 Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                                 FI 1871439-4                                                Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                                             Email: firstname.lastname@intertek.com


                                                          Test report           Identification: T08-606C-EMC
                                                    Product compliance test
                                                     EMC-measurements                                    Page: 23 of 27



11.2 Test method

                           1. The emissions were searched and maximized by moving the turntable,
                              changing the measuring antenna polarization and height and manipulating
                              the EUT.
                           2. Levels of suspicious signals and levels of EUT transmitter harmonics were
                              recorded.
                           3. The recorded levels were corrected in the automated test system with the
                              measurement antenna factor, cable attenuations and filter attenuation.
                           4. The corrected values, giving the EUT radiated spurious emission levels as
                              dBµV/m at 3 m distance, are reported.

11.3 EUT operation mode

                     EUT was connected to portable computer USB connector. Transmitter was set to
                     receiver active mode.

                       EUT operation mode             Receiver mode
                       EUT frequency                  2402 MHz
                       EUT TX power level             Na

11.4 Limit

                     Table 11:             Radiated spurious emission limits at measurement distance 3m
                       Frequency band                 3m Limit           3m Limit                   Detector
                            (MHz)                      (µV/m)            (dBµV/m)
                            30 – 88                      100                 40                        QP
                            88 -216                      150                43.5                       QP
                           216 - 960                     200                 46                        QP
                          960 - 1000                     500                54.0                       QP
                        1000 - 12400                     500                54.0                      AVG
                        1000 - 12400                    5000                74.0                      PEAK




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

Intertek ETL Semko Oy                                 Business ID                                  Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                          FI 1871439-4                                 Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                       Email: firstname.lastname@intertek.com


                                                              Test report               Identification: T08-606C-EMC
                                                     Product compliance test
                                                      EMC-measurements                                           Page: 24 of 27


11.5 Results
                     The measured interference values using Quasi peak and average detectors are
                     shown in the pictures below.

                     All signals closer than 6 dB to the limit below 1 GHz have been measured using
                     quasi peak or average detector and reported in the table 12, 13 and 14.


Table 12:            Radiated emissions using Quasi peak detector
          Freq            Measured           Correction       Result        Marginal    EUT            Ant        Ant          TT
          MHz              Value              Factor         dBuV/m         dBuV/m     Position        Pol.      height       angle
                           dBuV                 dB
          N/A

Table 13:               Radiated emissions using Peak detector
          Freq            Measured           Correction       Result        Marginal    EUT            Ant        Ant          TT
          MHz              Value              Factor         dBuV/m         dBuV/m     Position        Pol.      height       angle
                           dBuV                 dB
          N/A


Table 14:               Radiated emissions using Average detector
          Freq            Measured           Correction       Result        Marginal    EUT            Ant        Ant          TT
          MHz              Value              Factor         dBuV/m         dBuV/m     Position        Pol.      height       angle
                           dBuV                 dB
          N/A




Test results are valid for the tested unit only.                                        The report may be copied only in its entireness

Intertek ETL Semko Oy                                     Business ID                                      Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                              FI 1871439-4                                     Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                               Email: firstname.lastname@intertek.com


                                                                                                             Test report                     Identification: T08-606C-EMC
                                                                                                 Product compliance test
                                                                                                  EMC-measurements                                                    Page: 25 of 27



                                                          100      FCC PART 15.109; 30 MHz - 1 GHz




                                                           88




                                                           76




                                                           64




                                                           52




                                                           40 CFR 47 (FCC) 15.109 (a) Class B; 30M-1G; QP




                                                           28




                                                           16




                                                            4
                                         Level (dBµV/m)




                                                           -8




                                                          -20
                                                          30M                                    100M                                                     1G
                                                             Frequency (Hz)




                     Picture 17:                                              radiated emission results, 30 – 1000 MHz,
                                                                              Red= horizontal polarization, blue = vertical polarization


                                         110                    FCC PART 15.109; Idle; 1GHz- 12.5GHz; Measured at 1m corrected to 3m



                                         100



                                           90



                                           80

                                                           CFR 47 (FCC) 15.109 (a) Class B; 1-24G; PEAK
                                           70



                                           60

                                                           CFR 47 (FCC) 15.109 (a) Class B; 1-24G; Average
                                           50



                                           40



                                           30



                                           20



                                           10
                        Level (dBuV/m)




                                                      0



                                         -10
                                                  1G                                                                                   10G               20G
                                                    Frequency (Hz)




                     Picture 18:                                              radiated emission results, 1 – 12,5 GHz,
                                                                              Red= horizontal polarization, blue = vertical polarization




Test results are valid for the tested unit only.                                                                                             The report may be copied only in its entireness

Intertek ETL Semko Oy                                                                                 Business ID                                               Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                                                                          FI 1871439-4                                              Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                                                                                    Email: firstname.lastname@intertek.com


                                                         Test report          Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                   Page: 26 of 27


12      TEST EQUIPMENT

                     All testing and measurement equipment has been calibrated once a year, except the
                     antennas that are calibrated every two years.

12.1 Conducted measurements

                       Equipment                    Manufacturer             Model
                       Spectrum Analyzer            Agilent                  E7405A
                       Attenuator 3 dB              Narda                    779-3

12.2 Radiated measurements

                       Equipment                    Manufacturer             Model
                       Spectrum Analyzer            Agilent                  E7405A
                       Antenna                      Chase                    CBL 6141
                       Antenna                      Schwarzbeck              BBHA 9120D
                       Antenna                      Schwarzbeck              BBHA 9170
                       Band reject filter           Wainwright               WRCT2400/2483
                                                    Instruments
                       High pass filter             Wainwright               WHK3.0/18GST
                                                    Instruments
                       Pre-amplifier                Agilent                  87405B
                       Pre-amplifier                JCA                      118-400
                       Pre-amplifier                Miteq                    AMF-6F-18002650-25-10P
                       Turn table / antenna         EMCO                     2090
                       mast controller




Test results are valid for the tested unit only.                              The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                 Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                                Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                     Email: firstname.lastname@intertek.com


                                                         Test report         Identification: T08-606C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                  Page: 27 of 27


13 TEST SETUP PHOTOGRAPHS

                     Test setup photograph can be found in a separate document

                                    T08-606C-EMC_PHOTOS.doc




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

Intertek ETL Semko Oy                                Business ID                                Tel: +358 10 424 6200
P.O. Box 1350, Koneenkatu 12                         FI 1871439-4                               Fax: +358 10 424 6201
FI-05801 Hyvinkää, Finland                                                    Email: firstname.lastname@intertek.com



Document Created: 2008-07-04 10:12:43
Document Modified: 2008-07-04 10:12:43

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC