Test report

FCC ID: INWJ2

Test Report

Download: PDF
FCCID_740840

                                                                             Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                  Page: 1 of 19
EMC Laboratory                                                                                       MS-Word2000




                                                     Test report
                                                         for
                                                   Speed W.I.N.D



                     Report Date:                   November 2, 2006



                     Signatures:


                     Tested by:
                                                    _______________________________
                                                    Jani Kiiski       Test Engineer


                     Contents approved:
                                                    _______________________________
                                                    Tuomo Hahl        Test Engineer




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                  Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                               Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                      Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                                                         Identification: T06-140C-EMC
                                                                   Product compliance test
                                                                    EMC-measurements                                                                    Page: 2 of 19
EMC Laboratory                                                                                                                                         MS-Word2000

CONTENTS
1       LABORATORY INFORMATION .................................................................................................................................. 3
2       CUSTOMER INFORMATION........................................................................................................................................ 3
3       SUMMARY OF TEST RESULTS ................................................................................................................................... 4
4       EUT INFORMATION....................................................................................................................................................... 5
     4.1         EUT description ....................................................................................................................................... 5
     4.2         EUT TEST SETUPS................................................................................................................................ 5
5       APPLICABLE STANDARDS........................................................................................................................................... 6
6       FIELD STRENGTH OF FUNDAMENTAL ................................................................................................................... 7
     6.1         Test setup and measurement method ....................................................................................................... 7
     6.2         EUT operation mode................................................................................................................................ 7
     6.3         Limit......................................................................................................................................................... 7
     6.4         Results...................................................................................................................................................... 8
7       RADIATED SPURIOUS EMISSIONS ............................................................................................................................ 9
     7.1         Test setup ................................................................................................................................................. 9
     7.2         Test method............................................................................................................................................ 10
     7.3         EUT operation mode.............................................................................................................................. 10
     7.4         Limit....................................................................................................................................................... 10
     7.5         Results.................................................................................................................................................... 11
8       20 dB BANDWIDTH ....................................................................................................................................................... 12
     8.1         Test setup and measurement method ..................................................................................................... 12
     8.2         EUT operation mode.............................................................................................................................. 12
     8.3         Results.................................................................................................................................................... 13
     8.4         Screen shots ........................................................................................................................................... 13
9       99 % BANDWIDTH ........................................................................................................................................................ 14
     9.1         Test setup and measurement method ..................................................................................................... 14
     9.2         EUT operation mode.............................................................................................................................. 14
     9.3         Results.................................................................................................................................................... 15
     9.4         Screen shots ........................................................................................................................................... 15
10      FREQUENCY STABILITY............................................................................................................................................ 16
     10.1        Test setup and measurement method ..................................................................................................... 16
     10.2        EUT operation mode.............................................................................................................................. 16
     10.3        Results.................................................................................................................................................... 17
11      TEST EQUIPMENT........................................................................................................................................................ 18
     11.1        Radiated measurements.......................................................................................................................... 18
12      TEST SETUP PHOTOGRAPHS ................................................................................................................................... 19




Test results are valid for the tested unit only.                                                                          The report may be copied only in its entireness

NATLABS Oy                                                                 VAT nr:                                                              Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories                                  FI 1871439 4                                                           Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                                                                     Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                     Page: 3 of 19
EMC Laboratory                                                                                          MS-Word2000

1      LABORATORY INFORMATION

                     Test Laboratory                      NATLABS OY
                                                          EMC Laboratory
                                                          Koneenkatu 12 / K17
                                                          05830 Hyvinkää
                                                          FINLAND

                                                          Tel: +358 20 475 2600
                                                          Fax: +358 20 475 2719
                                                          e-mail: firstname.surname@ette.com

                     FCC registration                     910391 (January 27, 2003)
                     number:                              IC 4616 (May 14, 2003)
                     IC file number:


2      CUSTOMER INFORMATION

                     Client                               Polar Electro Oy
                                                          Professorintie 5
                                                          90440 Kempele
                                                          Finland

                                                          Tel. +358 9 875 870
                                                          Fax. +358 9 875 87301
                     Contact person:                      Kari Parkkisenniemi
                                                          Polar Electro Oy
                                                          Proessorintie 5
                                                          90440 Kempele
                                                          Finland


                                                          Tel. +35840-574 0869
                                                          Fax. +3588- 520 2220
                     Receipt of EUT:                      August 25, 2006
                     Testing date:                        September 6 – September 13, 2006
                     Report date:                         November 2, 2006

                     The tests listed in this report have been done to demonstrate compliance to the FCC
                     rules section §15.249, §15.209 and IC standard RSS-210.




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                     Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                                  Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                         Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                 Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                      Page: 4 of 19
EMC Laboratory                                                                                           MS-Word2000

3      SUMMARY OF TEST RESULTS

                     Transmitter measurements
                    Section in       Section in RSS-                Test                                          Result
                    CFR 47           210
                    § 15.249 (a)     A2.9 (1)                       Field strength of fundamental                 PASS
                    § 15.249 (a) (d) 2.7, A2.9 (2)                  Spurious radiated emissions                   PASS
                    § 15.215 (c)                                    20 dB bandwidth                               PASS
                                     RSS-GEN 4.4.1                  99% bandwidth                                 PASS
                    § 15.215 (c)     RSS-GEN 7.2.4                  Frequency stability                           PASS

                     PASS           Pass
                     FAIL           Fail
                     X              Measured, but there is no applicable performance criteria
                     Na             Not applicable




Test results are valid for the tested unit only.                                 The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                      Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                                   Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                          Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                     Identification: T06-140C-EMC
                                                    Product compliance test
                                                     EMC-measurements                                         Page: 5 of 19
EMC Laboratory                                                                                               MS-Word2000

4      EUT INFORMATION

                     The EUT and accessories used in the tests are listed below. Later in this report only
                     EUT numbers are used as reference.

                                            Device                   Type      S/N                         EUT number
                    EUT                     Speed sensor             Speed     S1                          14001 *1)
                                                                     W.I.N.D
                                            Speed sensor             Speed     S10                         14002 *2)
                                                                     W.I.N.D
                                            Speed sensor             Speed     S4                          14003 *3)
                                                                     W.I.N.D
                    Accessories Battery                              CR1632        14004
                    Notes:
                    *1)     Continuous carrier wave
                    *2)     Continuous modulated carrier, connector for conducted measurements
                    *3)     Continuous carrier wave, connector for conducted measurements

4.1      EUT description

                     EUT is battery powered cycling speed sensor that transmits its measurement data to
                     a cycling computer via radio link. Radio link uses fixed frequency (2471 MHz) and
                     GFSK modulation.

                     The EUT was not modified during the tests.

4.2      EUT TEST SETUPS

                     For each test the EUT was exercised to find out the worst case of operation modes
                     and device configuration.

                     Two different test setups were used: one for conducted measurements, another for
                     radiated measurements. Two EUT were equipped with an external antenna
                     connector for conductive measurements.

                     The test setup photographs are in the document referenced in section 12.




Test results are valid for the tested unit only.                                     The report may be copied only in its entireness

NATLABS Oy                                               VAT nr:                                         Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories                FI 1871439 4                                      Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                              Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                             Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                  Page: 6 of 19
EMC Laboratory                                                                                       MS-Word2000


5      APPLICABLE STANDARDS

                     The tests were performed in guidance of CFR 47 Part 15.249, 15.209, 15.109 and
                     Part 2, ANSI C63.4 (2003), RSS-GEN / RSS-210

                     Deviations, modifications or clarifications (if any) to above mentioned documents
                     are written in each section under "Test method" for each test case.




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                  Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                               Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                      Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                     Page: 7 of 19
EMC Laboratory                                                                                          MS-Word2000

6      FIELD STRENGTH OF FUNDAMENTAL

                       EUT                           14001
                       Accessories                   14004
                       Temp, Humidity,               25 ºC                   64 RH%                     1015 hPa
                       Air Pressure
                       Date of measurement           September 11, 2006
                       FCC rule part                 §15.249 (a)
                       RSS-210 section               A2.9 (1)
                       Measured by                   Jani Kiiski

6.1      Test setup and measurement method

                     The EUT was set on a non-conductive turntable in a semi-anechoic chamber.
                     The EUT was set at 0.8m height. Measuring antenna was scanned 1 – 4 m in
                     height.
                     The measurements were repeated in three EUT orientations and two antenna
                     polarizations.
                     The measured signal was routed from the measuring antenna to the spectrum
                     analyzer.
                     The measurement was made using 1 MHz resolution bandwidth and 1 MHz video
                     bandwidth and maximum hold function to record the maximum peak output power.


6.2      EUT operation mode

                       EUT operation mode            Continuous transmission
                       EUT frequency                 2471 MHz
                       EUT TX power level            -10 dBm (Software configuration)

6.3      Limit

            Table 1: Field strength of fundamental (Measured with average detector)
                       Frequency (MHz)              mV/m ( @3m)              dBµV/m ( @3m)
                          2400-2483.5                 50 (Avg)             94 (Avg) 114 (Peak)




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                      Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                                   Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                          Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                       Identification: T06-140C-EMC
                                                        Product compliance test
                                                         EMC-measurements                                       Page: 8 of 19
EMC Laboratory                                                                                                 MS-Word2000


6.4      Results

         Table 2:              Maximum field strength of fundamental (Peak value)
           Freq          Measured           Correction      Result       EUT           Antenna        Antenna        Turntable
           MHz           Value              Factor          dBuV/m       orientation   Pol.           height         angle
                         dBuV               dB
            2471             50.9                  34          84.9         Pos 3         Ver              4               11


                     Since the measurements are made with sample that is modified to continuous
                     transmission, average results are calculated from peak results using duty cycle.

                                    Average level ≤ Peak level – 20 log (duty cycle).

                     According to manufacturer the Duty cycle for this product is 150µs long
                     transmission at 5Hz frequency.

                     Therefore,

                                    Average level ≤ Peak level – 20 log ((100 ms – 150 µs) / 150µs)
                                    Average level ≤ Peak level – 56.5 dB




Test results are valid for the tested unit only.                                       The report may be copied only in its entireness

NATLABS Oy                                                   VAT nr:                                       Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories                    FI 1871439 4                                    Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                                Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                                                Identification: T06-140C-EMC
                                                          Product compliance test
                                                           EMC-measurements                                                              Page: 9 of 19
EMC Laboratory                                                                                                                          MS-Word2000

7       RADIATED SPURIOUS EMISSIONS

                       EUT                                    14001
                       Accessories                            14004
                       Temp, Humidity,                        27 ºC                                    63 RH%                           1009 hPa
                       Air Pressure
                       Date of measurement                    September 13, 2006
                       FCC rule part                          §15.249 (a) (d)
                       RSS-210 section                        2.7, A2.9 (2)
                       Measured by                            Jani Kiiski

7.1      Test setup

                     EUT was modified to send constant carrier at nominal frequency.

                     The test was done using an automated test system, where a computer controlled the
                     measurement equipments.


                      SHIELDED ANECHOIC ROOM        MEASUREMENT ANTENNA        4.0 m
                                                                                       NOTCH       PRE-
                                                                                       FILTER      AMPLIFIER
                         EUT
                                                                                                                      SPECTRUM
                                                                                                                      ANALYZER




                                                                     1.0 m
                                            3.0 m




                     Picture 1:            Test setup for radiated spurious emissions measurement
                                           30 MHz - 3 GHz frequencies

                      SHIELDED ANECHOIC ROOM
                                                      MEASUREMENT     4.0 m   HIGH PASS
                                                                                                PRE-AMPLIFIER
                                                        ANTENNA                 FILTER

                         EUT
                                                                                                                       SPECTRUM
                                                                                                                       ANALYZER




                                                             1.0 m
                                            1.0 m




                     Picture 2:            Test setup for radiated spurious emissions measurement
                                           3 GHz – 25 GHz frequencies




Test results are valid for the tested unit only.                                                                The report may be copied only in its entireness

NATLABS Oy                                                      VAT nr:                                                             Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories                       FI 1871439 4                                                          Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                                                         Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                Identification: T06-140C-EMC
                                                    Product compliance test
                                                     EMC-measurements                                   Page: 10 of 19
EMC Laboratory                                                                                          MS-Word2000


7.2      Test method

                           1. The emissions were searched and maximized by moving the turntable,
                              changing the measuring antenna polarization and height and manipulating
                              the EUT.
                           2. Levels of suspicious signals and levels of EUT transmitter harmonics were
                              recorded.
                           3. The recorded levels were corrected in the automated test system with the
                              measurement antenna factor, cable attenuations and filter attenuation.
                           4. The corrected values, giving the EUT radiated spurious emission levels as
                              dBµV/m at 3 m distance, are reported.

7.3      EUT operation mode

                       EUT operation mode             Continuous transmission
                       EUT frequency                  2471 MHz
                       EUT TX power level             -10 dBm (Software configuration)

7.4      Limit

                     Table 3:              Radiated spurious emission limits at measurement distance of 3m
                       Frequency band                 3m Limit           3m Limit                   Detector
                            (MHz)                      (µV/m)            (dBµV/m)
                            30 – 88                      100                 40                        QP
                            88 -216                      150                43.5                       QP
                           216 - 960                     200                 46                        QP
                          960 - 1000                     500                54.0                       QP
                        1000 - 25000                     500                54.0                      AVG
                        1000 - 25000                    5000                74.0                      PEAK

                     As default, all emissions were compared against the general limits. If any emission
                     exceeded that limit, it was further checked, that it complies with the -50dBc
                     requirement.




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

NATLABS Oy                                               VAT nr:                                    Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories                FI 1871439 4                                 Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                         Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                        Identification: T06-140C-EMC
                                                           Product compliance test
                                                            EMC-measurements                                    Page: 11 of 19
EMC Laboratory                                                                                                  MS-Word2000

7.5      Results

                     Measurement system noise level was least 20 dB below the spurious emission
                     limit. Only levels of suspicious signals and transmitter harmonic frequencies,
                     which were above the measurement system noise, are reported.

Table 4:             Emission levels PEAK detector
          Freq            Measured           Correction          Result     Marginal    EUT            Ant        Ant          TT
          MHz              Value              Factor            dBuV/m      dBuV/m     Position        Pol.      height       angle
                           dBuV                 dB
          4942               69.5                  -15.3          54.2       -19.8     Pos 3          Hor         1.05         198


                     Since the measurements are made with sample that is modified to continuous
                     transmission, average results are calculated from peak results using duty cycle.

                                    Average level ≤ Peak level – 20 log (duty cycle).

                     According to manufacturer the Duty cycle for this product is 150µs long
                     transmission at 5Hz frequency.

                     Therefore,

                                    Average level ≤ Peak level – 20 log ((100 ms – 150 µs) / 150µs)
                                    Average level ≤ Peak level – 56.5 dB




Test results are valid for the tested unit only.                                        The report may be copied only in its entireness

NATLABS Oy                                                      VAT nr:                                     Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories                       FI 1871439 4                                  Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                                 Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                    Page: 12 of 19
EMC Laboratory                                                                                          MS-Word2000

8       20 dB BANDWIDTH

                       EUT                           14002
                       Accessories                   14004
                       Temp, Humidity,               25 ºC                   61 RH%                     1005 hPa
                       Air Pressure
                       Date of measurement           September 06, 2006
                       FCC rule part                 §15.215 (c)
                       RSS-210 section
                       Measured by                   Jani Kiiski


8.1      Test setup and measurement method

                     The 20dB bandwidth was measured using 10 kHz resolution bandwidth and
                     maximum hold function of the spectrum analyzer. 20dB bandwidth was defined by
                     measuring the maximum level on the measured channel and by placing display line
                     20 dB below this value and by reading the bandwidth from the intersection of the
                     measured trace and display line.


8.2      EUT operation mode

                       EUT operation mode            Normal modulation
                       EUT frequency                 2471 MHz
                       EUT TX power level            -10 dBm (Software configuration)




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                      Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                                   Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                          Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                    Page: 13 of 19
EMC Laboratory                                                                                          MS-Word2000

8.3      Results
                     Table 5:              20dB bandwidth measurement results
                                EUT Frequency                        Limit                     Measured value
                                    MHz                              MHz                           MHz
                                    2471                               -                           0.807


8.4      Screen shots




                     Picture 3:            20dB Bandwidth measurement result




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

NATLABS Oy                                               VAT nr:                                    Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories                FI 1871439 4                                 Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                         Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                    Page: 14 of 19
EMC Laboratory                                                                                          MS-Word2000

9      99 % BANDWIDTH

                       EUT                           14002
                       Accessories                   14004
                       Temp, Humidity,               25 ºC                   61 RH%                     1005 hPa
                       Air Pressure
                       Date of measurement           September 06, 2006
                       FCC rule part
                       RSS-GEN section               4.4.1
                       Measured by                   Jani Kiiski


9.1      Test setup and measurement method

                     The 99% occupied bandwidth was calculated from spectrum analyzer
                     measurements.
                     The measurement data was read from the analyzer to computer.
                     Software in computer calculated the total power from the measurement data and
                     defined the frequency band containing 99% of the total power.
                     Markers in the spectrum analyzer were then placed between the calculated
                     frequencies to show the calculated 99% power band in the screenshots.


9.2      EUT operation mode

                       EUT operation mode            Normal modulation
                       EUT frequency                 2471 MHz
                       EUT TX power level            -10 dBm (Software configuration)




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                      Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                                   Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                          Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                               Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                   Page: 15 of 19
EMC Laboratory                                                                                         MS-Word2000

9.3      Results
                     Table 6:              99% bandwidth measurement results
                                EUT Frequency                       Limit                     Measured value
                                    MHz                             MHz                           MHz
                                    2471                              -                           0.833


9.4      Screen shots




                     Picture 4:            99% Bandwidth measurement result




Test results are valid for the tested unit only.                               The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                    Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                                 Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                        Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                  Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                      Page: 16 of 19
EMC Laboratory                                                                                            MS-Word2000

10 FREQUENCY STABILITY

                       EUT                           14003
                       Accessories
                       Temp, Humidity,               - ºC                      - RH%                      - hPa
                       Air Pressure
                       Date of measurement           September 13, 2006
                       FCC rule part                 §15.215 (c)
                       RSS-GEN section               7.2.4
                       Measured by                   Jani Kiiski

10.1 Test setup and measurement method


                             TEMPERATURE
                               CHAMBER

                                                                    Spectrum
                                      EUT                           analyzer




                           1. The climate chamber temperature was set to the maximum value and the
                              temperature was allowed to stabilize

                           2. The EUT was placed in the chamber power off

                           3. The EUT temperature was allowed to stabilize for 30 minutes

                           4. The EUT was turned on and set to transmit

                           5. Transmitter peak frequency was measured with spectrum analyzer

                           6. The steps 3 - 5 were repeated for each temperature

10.2 EUT operation mode

                       EUT operation mode            Continuous transmission
                       EUT channel                   2471 MHz
                       EUT TX power level            -10 dBm (Software configuration)




Test results are valid for the tested unit only.                                  The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                       Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                                    Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                           Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                                Identification: T06-140C-EMC
                                                    Product compliance test
                                                     EMC-measurements                                   Page: 17 of 19
EMC Laboratory                                                                                          MS-Word2000

10.3 Results
                     Table 7:              Frequency stability measurement results
                                             Temperature                       Transmitter frequency
                                                (º/C)                                 (MHz)
                                                  50                                 2471.071
                                                  40                                 2471.074
                                                  30                                 2471.080
                                                  20                                 2471.086
                                                  10                                 2471.090
                                                   0                                 2471.092
                                                 -10                                 2471.089
                                                 -20                                 2471.082
                                                 -30                                 2471.067




Test results are valid for the tested unit only.                                The report may be copied only in its entireness

NATLABS Oy                                               VAT nr:                                    Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories                FI 1871439 4                                 Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                         Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                              Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                  Page: 18 of 19
EMC Laboratory                                                                                        MS-Word2000

11      TEST EQUIPMENT

                     All testing and measurement equipment has been calibrated once a year, except the
                     antennas that are calibrated every two years.

11.1 Radiated measurements

                       Equipment                    Manufacturer             Model
                       Spectrum Analyzer            Agilent                  E7405A
                       Antenna                      Chase                    CBL 6141
                       Antenna                      Schwarzbeck              BBHA 9120D
                       Antenna                      Schwarzbeck              BBHA 9170
                       Band reject filter           Wainwright               WRCT2400/2483
                                                    Instruments
                       High pass filter             Wainwright               WHK3.0/18GST
                                                    Instruments
                       Pre-amplifier                Agilent                  87405B
                       Pre-amplifier                JCA                      118-400
                       Pre-amplifier                Miteq                    AMF-6F-18002650-25-10P
                       Turn table / antenna         EMCO                     2090
                       mast controller




Test results are valid for the tested unit only.                              The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                   Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                                Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                       Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland


                                                                             Identification: T06-140C-EMC
                                                   Product compliance test
                                                    EMC-measurements                                 Page: 19 of 19
EMC Laboratory                                                                                       MS-Word2000

12 TEST SETUP PHOTOGRAPHS

                     Test setup photograph can be found in a separate document

                                    T06-140C-EMC_PHOTOS.doc




Test results are valid for the tested unit only.                             The report may be copied only in its entireness

NATLABS Oy                                              VAT nr:                                  Tel: +358 20 475 2600
Nordic Accredited Testing Laboratories               FI 1871439 4                               Fax: +358 20 475 2719
P.O. Box 1300, Koneenkatu 12                                                      Email: firstname.lastname@ette.com
FIN-05801 Hyvinkää, Finland



Document Created: 2006-11-02 14:37:54
Document Modified: 2006-11-02 14:37:54

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC