RF Exposure Report

FCC ID: INGRU-G3TH

RF Exposure Info

Download: PDF
FCCID_4032731

                                                       FCC ID: INGRU-G3TH




   RF Exposure Evaluation
                               of
  E.U.T.         : UHF PLL hand-held transmitter

  FCC ID.        : INGRU-G3TH

  MODEL          : RU-G3TH


                               for

APPLICANT       :

ADDRESS         :

                           Prepared by


           ELECTRONICS TESTING CENTER, TAIWAN
              NO. 34. LIN 5. DINGFU, LINKOU DIST.,
            NEW TAIPEI CITY, TAIWAN, 24442, R.O.C.
           Tel:(02)26023052            Fax:(02)26010910
           http://www.etc.org.tw ; e-mail: emc@etc.org.tw
               Report Number : 17-07-RBF-020-MPE


                                                                FCC ID: INGRU-G3TH



         TEST REPORT CERTIFICATION
Applicant             : JTS Professional Co., Ltd.
                        NO. 148, 9TH INDUSTRY RD., TA-LI INDUSTRIAL PARK,
                        TAI-LI CITY, TAIWAN, R.O.C.


Manufacturer          : JTS Professional Co., Ltd.
                        NO. 148, 9TH INDUSTRY RD., TA-LI INDUSTRIAL PARK,
                        TAI-LI CITY, TAIWAN, R.O.C.


Description of EUT

 a)   Type of EUT     : UHF PLL hand-held transmitter
 b)   Trade Name      : JYS
 c)   Model No.       : RU-G3TH
 d)   Serial Model    : ---
 e) Power Supply      : DC 3V Battery


Regulation Applied        : FCC KDB447498 D01. The equipment fulfills the
requirements on power density for general population/uncontrolled exposure and
therefore fulfills the requirements of section 1.1310 of FCC 47 CFR Part 1.
Note:
1. The result of the testing report relate only to the item tested.
2. The testing report shall not be reproduced expect in full, without the written
approval of ETC


                                                     FCC ID: INGRU-G3TH




Date of Issue                  : Sep,25, 2018




   Test Engineer :
                         (Brian Huang, Engineer )




   Approve & Authorized Signer :
                                         Vincent Chang, Supervisor
                                       EMC Dept. II of ELECTRONICS
                                        TESTING CENTER, TAIWAN


                                                                FCC ID: INGRU-G3TH


Product Information:
Type of EUT: UHF PLL hand-held transmitter
FCC ID:      INGRU-G3TH
Model:       RU-G3TH


According to KDB 447498 section 4.3.1, the 1-g SAR test exclusion thresholds at test
separation distance ≤ 50 mm are determined by:



[(max. power of channel, including tune-up tolerance, mW) / (min. test separation
distance,mm)] ·[√f(GHz)] ≤ 3.0

The max. average power of channel, including tune-up tolerance(mW) is 10.0mW @
607.875MHz (With Tune-up tolerance),

The min. test separation distance (mm) is 5 mm,


So, [(max. power of channel, including tune-up tolerance, mW) / (min. test separation
distance, mm)] ·[√f(GHz)] = 1.56 < 3.0 (With Tune-up tolerance).


Therefore, standalone SAR measurements are not required for both head and body.
.