Test Report

FCC ID: INGIN64TH

Test Report

Download: PDF
FCCID_1054394

     FCC Part 74 Subpart H
      EMI TEST REPORT
                            of
   E.U.T.         :   UHF PLL single channel
                      diversity wireless system
   FCC ID.      : INGIN64TH
   Model No. : IN64TH
   Serial Model : IN64THSM
   Working Frequency : 502-697.875 MHz

                            for

APPLICANT : JTS Professional Co., Ltd.
ADDRESS   : NO. 148, 9TH INDUSTRY RD., TA-LI
              INDUSTRIAL PARK, TAI-LI CITY,
              TAIWAN, R.O.C.
                      Test Performed by

        ELECTRONICS TESTING CENTER (ETC) , TAIWAN
            NO. 34, LIN 5, DINGFU TSUEN, LINKOU SHIANG
               TAIPEI COUNTY, TAIWAN, 24442, R.O.C.
                 TEL : (02)26023052 FAX : (02)26010910
              http:// www.etc.org.tw ; e-mail:emc@etc.org.tw


                Report Number : 08-09-RBF-067-001


                                                               Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                             FCC ID.: INGIN64TH




                  TEST REPORT CERTIFICATION

 Applicant              : JTS Professional Co., Ltd.
                          NO. 148, 9TH INDUSTRY RD., TA-LI INDUSTRIAL PARK,
                          TAI-LI CITY, TAIWAN, R.O.C.
 Manufacturer           : JTS Professional Co., Ltd.
                             NO. 148, 9TH INDUSTRY RD., TA-LI INDUSTRIAL PARK,
                             TAI-LI CITY, TAIWAN, R.O.C.

 Description of EUT     :
                             a) Type of EUT         : UHF PLL single        channel   diversity
                                                      wireless system
                             b) Trade Name          : JTS
                             c) Model No.           : IN64TH
                             d) Serial Model        : IN64THSM
                             e) FCC ID              : INGIN64TH
                             f) Working Frequency   : 502-697.875 MHz
                             g) Power Supply        : Battery DC 1.5V*2




Regulation Applied : FCC Rules and Regulations Part 74 Subpart H (2008)

I HEREBY CERTIFY THAT; The data shown in this report were made in accordance with the
procedures given in ANSI C63.4 and the energy emitted by the device was founded to be within
the limits applicable. I assume full responsibility for accuracy and completeness of these data.

Issued Date :               Nov. 10, 2008



Test Engineer :
                                ( Vincent Chang )



Approve & Authorized Signer :
                                        Will Yauo, Manager
                                   EMC Dept. II of ELECTRONICS
                                    TESTING CENTER, TAIWAN




                                                                                           Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                                                                             FCC ID.: INGIN64TH




Table of Contents                                                                                                                                            Page
1. GENERAL INFORMATION ............................................................................................................................... 1
1.1 PRODUCT DESCRIPTION .......................................................................................................................................... 1
1.2 TEST METHODOLOGY .............................................................................................................................................. 1
1.3 TEST FACILITY ........................................................................................................................................................ 1
2. REQUIREMENTS OF PROVISIONS ................................................................................................................ 2
2.1   DEFINITION ............................................................................................................................................................. 2
2.2   FREQUENCIES AVAILABLE ...................................................................................................................................... 2
2.3   REQUIREMENTS FOR RADIO EQUIPMENT ON CERTIFICATION .................................................................................. 2
2.4   LABELING REQUIREMENT ....................................................................................................................................... 3
3. OUTPUT POWER MEASUREMENT ................................................................................................................ 4
3.1   PROVISION APPLICABLE ......................................................................................................................................... 4
3.2   MEASUREMENT PROCEDURE................................................................................................................................... 4
3.3   TEST DATA ............................................................................................................................................................. 6
3.4   RESULT CALCULATION ........................................................................................................................................... 7
3.5   TEST EQUIPMENT .................................................................................................................................................... 7
4. MODULATION CHARACTERISTICS ............................................................................................................. 8
4.1   PROVISIONS APPLICABLE ........................................................................................................................................ 8
4.2   MEASUREMENT METHOD........................................................................................................................................ 8
4.3   MEASUREMENT INSTRUMENT ................................................................................................................................. 9
4.4   MEASUREMENT RESULT ......................................................................................................................................... 9
5. OCCUPIED BANDWIDTH OF EMISSION .................................................................................................... 11
5.1 PROVISIONS APPLICABLE ...................................................................................................................................... 11
5.2 MEASUREMENT METHOD...................................................................................................................................... 11
5.3 OCCUPIED BANDWIDTH TEST EQUIPMENT ............................................................................................................ 11
5.4 BANDWIDTH MEASURED ...................................................................................................................................... 12
   5.4.1 Input Level Derived...................................................................................................................................... 12
   5.4.2 Occupied Bandwidth Plotted........................................................................................................................ 12
6. FIELD STRENGTH OF EMISSION................................................................................................................. 16
6.1   PROVISIONS APPLICABLE ...................................................................................................................................... 16
6.2   MEASUREMENT PROCEDURE................................................................................................................................. 16
6.3   MEASURING INSTRUMENT .................................................................................................................................... 17
6.4   MEASURING DATA ................................................................................................................................................ 18
6.5   OTHER EMISSION .................................................................................................................................................. 24
6.6   RADIATED MEASUREMENT PHOTOS ...................................................................................................................... 25
7. FREQUENCY STABILITY MEASUREMENT............................................................................................... 26
7.1   PROVISIONS APPLICABLE ...................................................................................................................................... 26
7.2   MEASUREMENT PROCEDURE................................................................................................................................. 26
7.3   MEASUREMENT INSTRUMENT ............................................................................................................................... 27
7.4   MEASUREMENT DATA .......................................................................................................................................... 28
8 CONDUCTED EMISSION MEASUREMENT ................................................................................................. 31
8.1 STANDARD APPLICABLE ....................................................................................................................................... 31




                                                                                                                                                                        Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                Sheet 1 of 31 Sheets
                                                                              FCC ID.: INGIN64TH



1. GENERAL INFORMATION

   1.1 Product Description
           a) Type of EUT             :   UHF PLL single channel diversity wireless system
           b) Trade Name              :   JTS
           c) Model No.               :   IN64TH
           d) Serial Model            :   IN64THSM
           e) FCC ID                  :   INGIN64TH
           f) Working Frequency       :   502-697.875 MHz
           g) Power Supply            :   Battery DC 1.5V*2
           h) Emission Designator     :   128KF3E
                                          2M+2DK=2x(16kHz)+2x(48kHz)x1=128kHz



   1.2 Test Methodology

        Both conducted and radiated testing were performed according to the procedures in
        chapter 13 of ANSI C63.4 (2003). Test also follow “TIA/ELA 603-Land Mobile FM or
        PM Communications Equipment Measurement and Performance Standsrds” and section
        2.1046, 2.1047, 2.1049, 2.1051, 2.1053, and 2.1055 of Part 2 of CFR 47.

   1.3 Test Facility

        The open area test site and conducted measurement facility used to collect the radiated
        data is located on the roof top of Building at NO.34, LIN 5, DINGFU TSUEN,
        LINKOU SHIANG TAIPEI COUNTY, TAIWAN, 24442, R.O.C.
        This site has been fully described in a report submitted to your office, and accepted in a
        letter dated Aug. 05, 2008.




                                                                                               Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                Sheet 2 of 31 Sheets
                                                                              FCC ID.: INGIN64TH



2. REQUIREMENTS OF PROVISIONS
   2.1 Definition
        Intentional radiator:
        A device that intentionally generates and emits radio frequency energy by radiation or
        induction.

   2.2 Frequencies Available
        According to sec. 74.802 of Part 74, the following frequencies are available for low
        power auxiliary station :

                                           Frequencies (MHz)

                             26.100-26.480           455.000-456.000
                             54.000-72.000           470.000-488.000
                             76.000-88.000           488.000-494.000
                             161.625-161.775         614.000-806.000
                             174.000-216.000         450.000-451.000
                             944.000-952.000


   2.3 Requirements for Radio Equipment on Certification

        (1) RF Output Power
           For transmitters, the power output shall be measured at the RF output terminals.


        (2) Modulation Characteristics
           For Voice Modulated Communication Equipment, a curve or equivalent data
           showing the frequency response of the audio modulating circuit over a range of 100
           to 5000 Hz shall be submitted.


        (3) Occupied Bandwidth
           For radiotelephone transmitter, other than single sideband or indenpent sideband
           transmitter, when modulateed by a 2.5kHz tone at an input level 16 dB greater than
           that necessary to produce 50 percent modulation.


        (4) Spurious Emissions at Antenna Terminals
           The radio frequency voltage or power generated within the equipment and appearing
           on a spurious frequency shall be checked at the equipment output terminal when
           properly loaded with a suitable artificial antenna.




                                                                                               Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                               Sheet 3 of 31 Sheets
                                                                             FCC ID.: INGIN64TH




        (5) Field Strength of Spurious Emissions
           Measurements shall be made to detect spurious emission that may be radiated
           directly from the cabinet, control circuits, power leads, or intermediate circuit
           elements under normal condition of installation and operation.

        (6) Frequencies Tolerance
           a) The frequency stability shall be measured with variation of ambient temperature.
           b) The frequency stability shall be measured with variation of primary supply voltage.



   2.4 Labeling Requirement
       Each equipment for which a type acceptance application is filed on or after May 1,1981,
       shall bear an identification plate or label pursuant to § 2.925 ( Identification of
       equipment) and §2.926(FCC identifier).




                                                                                              Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                Sheet 4 of 31 Sheets
                                                                              FCC ID.: INGIN64TH



3. OUTPUT POWER MEASUREMENT



   3.1 Provision Applicable
       According to §74.861(e)(1)(ii), the output power shall not exceed 250 milliwatts.


   3.2 Measurement Procedure
       1. Setup the configuration per figure 1 and 2 for frequencies measured below and above 1
          GHz respectively, adjusting the input voltage to produce the maximum power.
       2. Adjust the analyzer for each frequency measured in chapter 6 on a 1 MHz frequency
          span and 1MHz resolution bandwidth.
       3. The search antenna is to be raised and lowered over a range from 1 to 4 meters in
          horizontally polarized orientation. Position the highness when the highest value is
          indicated on spectrum analyzer, then change the orientation of EUT on test table over a
          range from 0。 to 360 。, and record the highest value indicated on spectrum analyzer
          as reference value.
       4. Repeat step 3 until all frequencies need to be measured were complete.
       5. Repeat step 4 with search antenna in vertical polarized orientations.
       6. Replace the EUT with a tuned dipole antenna (horn antenna for above 1 GHz) relative
          to each frequency in horizontally polarized orientation and as the same polarized
          orientation with search antenna. Connect the tuned dipole antenna to a standard signal
          generator (SG) via a low loss cable. Power on the SG and tune the right frequency in
          measuring as well as set SG at a appreciated output level. Rise and lower the search
          antenna to get the highest value on spectrum analyzer, and then hold this position.
          Adjust the SG output to get a identical value derived from step 3 on spectrum analyzer.
          Record this value for result calculated.


       7. Repeat step 6 until all frequencies need to be measured were complete.


       8. Repeat step 7 with both dipole antenna (horn antenna for above 1 GHz) and search
          antenna in vertical polarized orientations.




                                                                                               Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                               Sheet 5 of 31 Sheets
                                                                             FCC ID.: INGIN64TH



                        Figure 2 : Frequencies measured below 1 GHz configuration


                                                                             Antenna Tower



                                       3m                                         Search
                                                                                 Antenna
                EUT
                                              4m
                                                                          RF Test
                                                                          Receiver


                         Turn                      1m
                                      0.8m
                         Table




                      Ground Plane




                        Figure 1 : Frequencies measured above 1 GHz configuration


                                                                        Antenna Tower



                                 3m                                    Horn Antenna
          EUT
                                       4m                             Spectrum
                                                                      Analyzer


                 Turn                        1m
                             0.8m
                 Table
                                                                         Amplifier




                                                                                              Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                            Sheet 6 of 31 Sheets
                                                                          FCC ID.: INGIN64TH


   3.3 Test Data

            A. Channel Low (ERP)
            Operated mode : TX                      Test Date   : Nov. 05, 2008
            Temperature   : 25 °C                   Humidity    : 65 %

            Frequency      Meter    SG    Cable Antenna Result Output    Limit
                          Reading Reading Loss                 Power
              (MHz)                              Gain (dBm)
                         (dBμV/m) (dBm) (dB)                   (mW)     (mW)

                   502        80.9   8.0     -2    ----   6.0   3.981     250



            B. Channel Mid (ERP)
            Operated mode : TX                      Test Date   : Nov. 05, 2008
            Temperature    : 25 °C                  Humidity    : 65 %

            Frequency      Meter    SG    Cable Antenna Result Output    Limit
                          Reading Reading Loss                 Power
              (MHz)                              Gain (dBm)
                         (dBμV/m) (dBm) (dB)                   (mW)     (mW)

                   600       80.7    10.6   -2.2   ----   8.4   6.918     250




            C. Channel High (ERP)
            Operated mode : TX                      Test Date   : Nov. 05, 2008
            Temperature    : 25 °C                  Humidity    : 65 %

            Frequency      Meter    SG    Cable Antenna Result Output    Limit
                          Reading Reading Loss                 Power
              (MHz)                              Gain (dBm)
                         (dBμV/m) (dBm) (dB)                   (mW)     (mW)

              697.875         80.5   10.9   -2.3   ----   8.6   7.244     250
         Note: For measured frequency below 1GHz, a tuned dipole antenna is used.




                                                                                           Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                             Sheet 7 of 31 Sheets
                                                                           FCC ID.: INGIN64TH




   3.4 Result Calculation

          Result calculation is as following :
           Result = SG Reading +Cable Loss +Antenna Gain Corrected
           Antenna Gain Corrected : is used for antenna other than dipole to convert radiated
           power to ERP.

                                   Result(dBm)
                   mW = log −1[                ]
                                       10

   3.5 Test Equipment

          Equipment             Manufacturer       Model No. Calibration Date Next Cal. Date
      EMI Test Receiver        Rohde & Schwarz      ESCI      2007/12/27       2008/12/26
      Double Ridged            EMCO                 3115      2008/05/14       2009/05/14
      Antenna
      Signal generator         HP                   8656B       2007/11/29         2008/11/28




                                                                                            Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                              Sheet 8 of 31 Sheets
                                                                            FCC ID.: INGIN64TH



4. MODULATION CHARACTERISTICS
   4.1 Provisions Applicable

       According to § 2.1047 (a), for Voice Modulated Communication Equipment, the
       frequency response of the audio modulating circuit over a range of 100 to 5000 Hz shall
       be measured.


   4.2 Measurement Method

       A) Modulation Limit

       1. Position the EUT as shown in figure 3, adjust the audio input frequency to 100 Hz and
          the input level from 0V to maximum permitted input voltage with recording each
          carrier frequency deviation responding to respective input level.

       2. Repeat step 1 with changing the input frequency for 200, 500, 1000, 3000, and 5000
          Hz in sequence.


       B) Frequency response of all circuits

       1. Position the EUT as shown in figure 3.

       2. Vary the modulating frequency from 100 Hz to 15000 Hz with constant input voltage
          (derived from 5.4(a) of this test report), and observe the change in output.

                 Figure 3 : Modulation characteristic measurement configuration

                                                               Radio
                        EUT                                Communication
                                                              Test Set


                                                             Spectrum
                                                             Analyzer




                                                                                             Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                                                           Sheet 9 of 31 Sheets
                                                                                                                         FCC ID.: INGIN64TH


   4.3 Measurement Instrument

           Equipment                                  Manufacturer                Model No. Calibration Date Next Cal. Date
      Radio Communication                             Marconi                      2955B     2008/10/30       2009/10/29
      Test Set
      Spectrum Analyzer                               Rohde & Schwarz                  FSP40              2008/09/05                 2009/09/05




   4.4 Measurement Result

              A). Frequency response

                                           100 Hz              200 Hz             500 Hz                  1kHz               3 kHz               5 kHz

                          6


                          5


                          4
       Output Level (V)




                          3


                          2


                          1


                          0
                              1   5   10   20   30   40   50    60      70   80   90    100   150   200   250    300   350   400   450    500   800 1000
                                                                                                                                         Input Level (mV)




                                                                                                                                                Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                                                                                                                             Sheet 10 of 31 Sheets
                                                                                                                                                                                            FCC ID.: INGIN64TH




                                      B). Modulation Limit

                                                            100 Hz                                200 Hz                        500 Hz                   1kHz             3 kHz             5 kHz
  kHz
    55

                        50

                        45

                        40

                        35

                        30

                        25

                        20

                        15

                        10

                             5

                             0
                                  1         5         10         20         30         40         50         60     70     80       90       100   150 200    250   300 350    400    450 500    800 1000
                                                                                                                                                                           Input Level (mV)




                                      C). Frequency response of all circuits



                                 30


                                 20
   Frequency Response (dB)




                                 10


                                  0


                             -10


                             -20


                             -30
                                      0.1       0.2        0.3        0.4        0.5        0.6        0.7    0.8    0.9        1        2     3     4    5     6     7    8      9    10   11    12   13   14   15

                                                                                                                                                                                        Input Frequency (kHz)




                                                                                                                                                                                                                 Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                 Sheet 11 of 31 Sheets
                                                                                FCC ID.: INGIN64TH



5. OCCUPIED BANDWIDTH OF EMISSION
   5.1 Provisions Applicable

       According to §2.1049 (c)(1), For radiotelephone transmitter, other than single sideband
       or indenpent sideband transmitter, when modulateed by a 2.5kHz tone at an input level
       16 dB greater than that necessary to produce 50 percent modulation.
       According to §74.861( e)(5), the frequency emission bandwidth shall not exceed 200 kHz.


   5.2 Measurement Method
       1. Check the calibration of the measuring instrument using either an internal calibrator or
          a known signal from an external generator.

       2. Position the EUT as shown in figure 4, and Install new batteries in the EUT. Turn on
          the EUT ant set it to any one convenient frequency within its operating range. Set a
          reference level on the measuring instrument equal to the highest peak value.

       3. Apply a 2.5 kHz modulation signal to EUT and measure the frequencies of the
          modulated signal from the EUT where it is the specified number of dB below the
          reference level set in step 2. This is the occupied bandwidth specified.

                   Figure 4 : Occupied bandwidth measurement configuration


                                                                    Radio
                            EUT                                 Communication
                                                                   Test Set


                                                                  Spectrum
                                                                  Analyzer




   5.3 Occupied Bandwidth Test Equipment

           Equipment               Manufacturer      Model No. Calibration Date Next Cal. Date
      Radio Communication          Marconi            2955B     2008/10/30       2009/10/29
      Test Set
      Spectrum Analyzer            Rohde & Schwarz     FSP40       2008/09/05           2009/09/05




                                                                                                 Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                                           Sheet 12 of 31 Sheets
                                                                                                          FCC ID.: INGIN64TH


   5.4 Bandwidth Measured

        5.4.1 Input Level Derived

                 Input Audio Frequency : 2.5 kHz, Sine Wave


                           Frequency Devition
      kHz
        50
        45
        40
        35
        30
        25
        20
        15
        10
         5
         0
             1    5   10   20   30   40   50    60   70   80   90   100   150   200   250   300   350   400   450   500    800 1000
                                                                                                                          Input Level (mV)


             The Level input to produce 50﹪modulation is 25 mV, therefore the magnitude 16 dB
             greater than it is 995.2 mV.



        5.4.2 Occupied Bandwidth Plotted
             The Channel Low 26 dB Bandwidth is 132.000KHz.
             The Channel Mid 26 dB Bandwidth is 132.500KHz.
             The Channel High 26 dB Bandwidth is 132.500KHz.




                                                                                                                                 Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                    Sheet 13 of 31 Sheets
                                                                                   FCC ID.: INGIN64TH


                                                  * RBW 3 kHz   Delta 1 [T1 ]
                                                   VBW 10 kHz               0.01 dB
       Ref    0 dBm             Att   30 dB        SWT 30 ms       132.000000000 kHz
       0                                                        Marker 1 [T1 ]
                                                                          -35.88 dBm
                                                                                       *
                                                                   501.932500000 MHz    A
       -10

1 PK
VIEW
       -20



       -30
                         1                                        1
                D1 -35.88 dBm
                                                                                       PS
       -40



       -50

                                                                                       3DB
       -60                                                                             AC



       -70



       -80



       -90


       -100

       Center 502 MHz                         25 kHz/                   Span 250 kHz




Date: 5.NOV.2008        08:14:27




                                                                                                    Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                    Sheet 14 of 31 Sheets
                                                                                   FCC ID.: INGIN64TH


                                                  * RBW 3 kHz   Delta 1 [T1 ]
                                                   VBW 10 kHz               0.77 dB
       Ref    0 dBm             Att   30 dB        SWT 30 ms       132.500000000 kHz
       0                                                        Marker 1 [T1 ]
                                                                          -37.06 dBm
                                                                                       *
                                                                   599.932000000 MHz    A
       -10

1 PK
VIEW
       -20



       -30
                         1                                        1
                D1 -36.19 dBm                                                          PS
       -40



       -50

                                                                                       3DB
       -60                                                                             AC



       -70



       -80



       -90


       -100

       Center 600 MHz                         25 kHz/                   Span 250 kHz




Date: 5.NOV.2008        08:38:21




                                                                                                    Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                   Sheet 15 of 31 Sheets
                                                                                  FCC ID.: INGIN64TH


                                                 * RBW 3 kHz   Delta 1 [T1 ]
                                                  VBW 10 kHz               0.70 dB
       Ref    0 dBm            Att   30 dB        SWT 30 ms       132.500000000 kHz
       0                                                       Marker 1 [T1 ]
                                                                         -36.41 dBm
                                                                                      *
                                                                  697.807000000 MHz    A
       -10

1 PK
VIEW
       -20



       -30
                         1                                       1
                D1 -35.6 dBm
                                                                                      PS
       -40



       -50

                                                                                      3DB
       -60                                                                            AC



       -70



       -80



       -90


       -100

       Center 697.875 MHz                    25 kHz/                   Span 250 kHz




Date: 5.NOV.2008       08:11:56




                                                                                                   Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                 Sheet 16 of 31 Sheets
                                                                                FCC ID.: INGIN64TH



6. FIELD STRENGTH OF EMISSION
   6.1 Provisions Applicable
       According to §2.1053, measurements shall be made to detect spurious emission that may
       be radiated directly from the cabinet, control circuits, power leads, or intermediate circuit
       elements under normal condition of installation and operation. Information submitted
       shall include the relative radiated power of spurious emission with reference to the rated
       power output of the transmitter, assuming all emissions are radiated from a halfwave
       dipole antenna.

       According to §74.861(e)(6), the mean power of emissions shall be attenuated below the
       mean output power of the transmitter in accordance with the follwing sceedule:
       (i)       on any frequency removed from the operating frequency by more than 50 percent
            up to and including 100 percent of the authorized bandwidth: at least 25 dB.
       (ii)      on any frequency removed from the operating frequency by more than 100
            percent up to and including 250 percent of the authorized bandwidth: at least 35 dB.
       (iii)     on any frequency removed from the operating frequency by more than 250
            percent of the authorized bandwidth shall be attenuated below the unmodulated carrier
            by at least 43 plus 10 Log(output power in watts) dB.


   6.2 Measurement Procedure
       1. Setup the configuration per figure 1 and 2 for frequencies measured below and above 1
          GHz respectively, adjusting the input voltage to produce the maximum power as
          measured in chapter 3.
       2. Adjust the analyzer for each frequency measured in chapter 6 on a 1 MHz frequency
          span and 1MHz resolution bandwidth.
       3. The search antenna is to be raised and lowered over a range from 1 to 4 meters in
          horizontally polarized orientation. Position the highness when the highest value is
          indicated on spectrum analyzer, then change the orientation of EUT on test table over a
          range from 0。 to 360 。, and record the highest value indicated on spectrum analyzer
          as reference value.
       4. Repeat step 3 until all frequencies need to be measured were complete.
       5. Repeat step 4 with search antenna in vertical polarized orientations.
       6. Replace the EUT with a tuned dipole antenna (horn antenna for above 1 GHz) relative
          to each frequency in horizontally polarized orientation and as the same polarized
          orientation with search antenna. Connect the tuned dipole antenna to a standard signal
          generator (SG) via a low loss cable. Power on the SG and tune the right frequency in
          measuring as well as set SG at a appreciated output level. Rise and lower the search
          antenna to get the highest value on spectrum analyzer, and then hold this position.
          Adjust the SG output to get a identical value derived from step 3 on spectrum analyzer.
          Record this value for result calculated.



                                                                                                 Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                            Sheet 17 of 31 Sheets
                                                                           FCC ID.: INGIN64TH



       7. Repeat step 6 until all frequencies need to be measured were complete.
       8. Repeat step 7 with both dipole antenna (horn antenna for above 1 GHz) and search
          antenna in vertical polarized orientations.

   6.3 Measuring Instrument


           Equipment               Manufacturer   Model No. Calibration Date Next Cal. Date
      Spectrum Analyzer            Rohde & Schwarz FSP40     2008/09/11       2009/09/11
      Double Ridged Antenna        EMCO            3115      2008/05/14       2009/05/14
      Log-periodic Antenna         EMCO            3146      2008/10/25       2009/10/24
      Biconical Antenna            EMCO            3110      2007/12/21       2008/12/20
      Amplifier                    HP              8449B     2008/09/20       2009/09/19
      Amplifier                    HP              8447D     2008/09/05       2009/09/05

        Measuring instrument setup in frequency band measured is as following :

         Frequency Band                                              Resolution         Video
                                    Instrument         Function
              (MHz)                                                  bandwidth       Bandwidth
            30 to 1000         Spectrum Analyzer      Peak            100 kHz          100 kHz
           Above 1000          Spectrum Analyzer      Peak            1 MHz            1 MHz




                                                                                            Rev. 2.0


   ETC Report No.:08-09-RBF-067-001                                            Sheet 18 of 31 Sheets
                                                                              FCC ID.: INGIN64TH


      6.4 Measuring Data

               Mode: 502-697.875MHz

               a. Channel Low
               Operated mode : TX                      Test Date   : Nov. 05, 2008
               Temperature    : 25 °C                  Humidity    : 65 %


          Unmodulated carrier output power is 6.0 dBm , or 3.981 mW (ERP).
          The limit of spurious or harmonics is calculated as following :
                               6.0-[43+10log(carrier output power in W)], or -13dBm

Frequency Meter Reading       SG Reading Antenna Antenna Cable           Result       Limit Margin
            (dBuV)              (dBm)      Gain   Gain    Loss           (dBm)
  (MHz)     H      V           H     V            Corr’   (dB)           H V          (dBm) (dB)
1004.000     ---     ---        ---    ---    6.4    -2.0  1.30          ---    ---    -13.0   ---
1506.000     ---     ---        ---    ---    9.3    -2.0  1.75          ---    ---    -13.0   ---
2008.000     ---     ---        ---    ---    9.2    -2.0  1.75          ---    ---    -13.0   ---
2510.000     ---     ---        ---    ---    9.7    -2.0  1.75          ---    ---    -13.0   ---
3012.000     ---     ---        ---    ---    9.6    -2.0  2.10          ---    ---    -13.0   ---
3514.000     ---     ---        ---    ---  10.6     -2.0  2.10          ---    ---    -13.0   ---
4016.000     ---     ---        ---    ---  10.9     -2.0  2.10          ---    ---    -13.0   ---
4518.000     ---     ---        ---    ---  10.9     -2.0  2.60          ---    ---    -13.0   ---
5020.000     ---     ---        ---    ---  12.1     -2.0  2.60          ---    ---    -13.0   ---
          Note :
          1. Remark “---“ means that the emission level is too weak to be detected.
          2. For measured frequency below 1GHz, a tuned dipole antenna is used.
          3. Result calculation is as following :
              Result = SG Reading +Cable Loss +Antenna Gain +Antenna Gain Corrected
              Antenna Gain Corrected : is used for antenna other than dipole to convert radiated
              power to ERP.
          4. Spurious or harmonics above 1 GHz is too low to be detected or attenuated more than
             60 dB from limit value.




                                                                                               Rev. 2.0


   ETC Report No.:08-09-RBF-067-001                                            Sheet 19 of 31 Sheets
                                                                              FCC ID.: INGIN64TH




               a. Channel Middle
               Operated mode : TX                      Test Date   : Nov. 05, 2008
               Temperature    : 25 °C                  Humidity    : 65 %


          Unmodulated carrier output power is 8.4 dBm , or 6.918 mW (ERP).
          The limit of spurious or harmonics is calculated as following :
                               8.4-[43+10log(carrier output power in W)], or -13dBm

Frequency Meter Reading       SG Reading Antenna Antenna Cable           Result       Limit Margin
            (dBuV)              (dBm)      Gain   Gain    Loss           (dBm)
  (MHz)     H      V           H     V            Corr’   (dB)           H V          (dBm) (dB)
1200.000     ---     ---        ---    ---    6.4    -2.0  1.30          ---    ---    -13.0   ---
1800.000     ---     ---        ---    ---    9.3    -2.0  1.75          ---    ---    -13.0   ---
2400.000     ---     ---        ---    ---    9.2    -2.0  1.75          ---    ---    -13.0   ---
3000.000     ---     ---        ---    ---    9.7    -2.0  1.75          ---    ---    -13.0   ---
3600.000     ---     ---        ---    ---    9.6    -2.0  2.10          ---    ---    -13.0   ---
4200.000     ---     ---        ---    ---  10.6     -2.0  2.10          ---    ---    -13.0   ---
4800.000     ---     ---        ---    ---  10.9     -2.0  2.10          ---    ---    -13.0   ---
5400.000     ---     ---        ---    ---  10.9     -2.0  2.60          ---    ---    -13.0   ---
6000.000     ---     ---        ---    ---  12.1     -2.0  2.60          ---    ---    -13.0   ---
          Note :
          1. Remark “---“ means that the emission level is too weak to be detected.
          2. For measured frequency below 1GHz, a tuned dipole antenna is used.
          3. Result calculation is as following :
              Result = SG Reading +Cable Loss +Antenna Gain +Antenna Gain Corrected
              Antenna Gain Corrected : is used for antenna other than dipole to convert radiated
              power to ERP.
          4. Spurious or harmonics above 1 GHz is too low to be detected or attenuated more than
             60 dB from limit value.




                                                                                               Rev. 2.0


   ETC Report No.:08-09-RBF-067-001                                            Sheet 20 of 31 Sheets
                                                                              FCC ID.: INGIN64TH




               c. Channel High

               Operated mode : TX                      Test Date   : Nov. 05, 2008
               Temperature   : 25 °C                   Humidity    : 65 %


          Unmodulated carrier output power is 8.6 dBm , or 7.244 mW (ERP).
          The limit of spurious or harmonics is calculated as following :
                               8.6-[43+10log(carrier output power in W)], or -13dBm

Frequency Meter Reading       SG Reading Antenna Antenna Cable           Result     Limit Margin
            (dBuV)              (dBm)      Gain   Gain    Loss           (dBm)
  (MHz)     H      V           H     V            Corr’   (dB)           H V       (dBm) (dB)
1395.750     ---     ---        ---    ---    9.1    -2.0   1.3          ---   --- -13.0     ---
2093.625     ---     ---        ---    ---    9.3    -2.0   1.7          ---   --- -13.0     ---
2791.500     ---     ---        ---    ---    9.7    -2.0   1.7          ---   --- -13.0     ---
3489.375     ---     ---        ---    ---    9.6    -2.0   2.1          ---   --- -13.0     ---
4187.250     ---     ---        ---    ---  10.9     -2.0   2.1          ---   --- -13.0     ---
4885.125     ---     ---        ---    ---  10.9     -2.0   2.1          ---   --- -13.0     ---
5583.000     ---     ---        ---    ---  11.9     -2.0   2.5          ---   --- -13.0     ---
6280.875     ---     ---        ---    ---  11.8     -2.0   2.5          ---   --- -13.0     ---
6978.750     ---     ---        ---    ---  11.5     -2.0   2.9          ---   --- -13.0     ---
          Note :
          1. Remark “---“ means that the emission level is too weak to be detected.
          2. For measured frequency below 1GHz, a tuned dipole antenna is used.
          3. Result calculation is as following :
              Result = SG Reading +Cable Loss +Antenna Gain +Antenna Gain Corrected
              Antenna Gain Corrected : is used for antenna other than dipole to convert radiated
              power to ERP.
          4. Spurious or harmonics above 1 GHz is too low to be detected or attenuated more than
             60 dB from limit value.

               d. Emission mask plots




                                                                                               Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                 Sheet 21 of 31 Sheets
                                                                                FCC ID.: INGIN64TH


                                            * RBW 3 kHz      Marker 1 [T1 ]
                                                VBW 10 kHz              -9.82 dBm
       Ref    0 dBm           Att   30 dB       SWT 225 ms      502.024000000 MHz
       0
                                                                                    *
                                            1
                                                                                     A
       -10
       F502-000
1 PK
VIEW
       -20



       -30


                                                                                    PS
       -40



       -50

                                                                                    3DB
       -60                                                                          AC



       -70



       -80



       -90


       -100

       Center 502 MHz                   200 kHz/                       Span 2 MHz




Date: 5.NOV.2008        08:20:47




                                                                                                 Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                  Sheet 22 of 31 Sheets
                                                                                 FCC ID.: INGIN64TH


                                                * RBW 3 kHz   Marker 1 [T1 ]
                                                 VBW 10 kHz             -10.14 dBm
       Ref    0 dBm           Att   30 dB        SWT 225 ms      599.972000000 MHz
       0
                                                                                     *
                                            1
                                                                                      A
       -10
       F600-000
1 PK
VIEW
       -20



       -30


                                                                                     PS
       -40



       -50

                                                                                     3DB
       -60                                                                           AC



       -70



       -80



       -90


       -100

       Center 600 MHz                   200 kHz/                        Span 2 MHz




Date: 5.NOV.2008        08:39:46




                                                                                                  Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                    Sheet 23 of 31 Sheets
                                                                   FCC ID.: INGIN64TH


                                           * RBW 3 kHz
                                             VBW 10 kHz
       Ref    0 dBm          Att   30 dB     SWT 225 ms
       0
                                                                       *
                                                                        A
       -10
       F697-875
1 PK
VIEW
       -20



       -30


                                                                       PS
       -40



       -50

                                                                       3DB
       -60                                                             AC



       -70



       -80



       -90


       -100

       Center 697.875 MHz              200 kHz/           Span 2 MHz




Date: 5.NOV.2008      08:32:21




                                                                                    Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                Sheet 24 of 31 Sheets
                                                                               FCC ID.: INGIN64TH




   6.5 Other Emission


            a) Emission frequencies below 1 GHz

            Test Date : Nov. 05, 2008          Temperature : 25 °C              Humidity : 65 %

              Frequency Ant-Pol     Meter    Corrected    Result    Limit    Margin    Table      Ant.
                                   Reading    Factor      @3m      @3m        (dB)    Degree     High
                (MHz)      H/V     (dBuV)      (dB)      (dBuV/m) (dBuV/m)            (Deg.)      (m)
              182.170       V        27.7       -8.9        18.8     43.5    -24.7      175         1.0
              192.180       V        29.6       -8.1        21.5     43.5    -22.0      182         1.0
              228.920       V        27.9       -5.2        22.7     46.0    -23.3      192         1.0
              382.610       V        29.6       -6.1        23.5     46.0    -22.5      177         1.0
              445.640       H        31.2       -5.6        25.6     46.0    -20.4       75         1.5
              511.060       V        33.2       -4.7        28.5     46.0    -17.5      192         1.0
  Note :
           1. Remark “---” means that the emissions level is too low to be measured.
           2. The expanded uncertainty of the radiated emission tests is 3.53 dB.

            b) Emission frequencies above 1 GHz
               Radiated emission frequencies above 1 GHz to 25 GHz were too low to be
               measured with a pre-amplifier of 35 dB.




                                                                                                Rev. 2.0


ETC Report No.:08-09-RBF-067-001      Sheet 25 of 31 Sheets
                                     FCC ID.: INGIN64TH




   6.6 Radiated Measurement Photos




                                                      Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                              Sheet 26 of 31 Sheets
                                                                             FCC ID.: INGIN64TH



7. FREQUENCY STABILITY MEASUREMENT
   7.1 Provisions Applicable

       According to §2.1055 (a)(1), the frequency stability shall be measured with variation of
       ambient temperature from -30℃to +50℃centigrade, and according to §2.1055 (d)(2), the
       frequency stability shall be measured with variation of primary supply voltage from 85 to
       115 percent of the nominal value for other than hand carried battery equipment.

       According to §74.861(e)(4), the frequency tolerance of the transmitter shall be 0.005
       percent.



   7.2 Measurement Procedure

       A) Frequency stability versus environmental temperature

       1. Setup the configuration per figure 5 for frequencies measured at ambient temperature
          if it is within 15℃to 25℃. Otherwise, an environmental chamber set for a temperature
          of 20℃shall be used.


       2. Turn on EUT and set SA center frequency to the right frequency needs to be measured.
          Then set SA RBW to 30 kHz, VBW to 100kHz and frequency span to 500 kHz.
          Record this frequency to be a reference.

       3. Set the temperature of chamber to 50℃. Allow sufficient time (approximately 30 min)
          for the temperature of the chamber to stabilize. While maintaining a constant
          temperature inside the chamber, turn the EUT on and measure the EUT operating
          frequency.

       4. Repeat step 2 with a 10℃decreased per stage until the lowest temperature -30℃is
          measured, record all measurement frequencies.



       B) Frequency stability versus input voltage


       1. Setup the configuration per figure 7 for frequencies measured at ambient temperature
          if it is within 15℃to 25℃. Otherwise, an environmental chamber set for a temperature
          of 20℃shall be used. Install new batteries in the EUT.




                                                                                              Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                 Sheet 27 of 31 Sheets
                                                                                FCC ID.: INGIN64TH



       2. Set SA center frequency to the right frequency needs to be measured. Then set SA
          RBW to 30 kHz, VBW to 100kHz and frequency span to 500 kHz. Record this
          frequency to be a reference.


       3. For non hand carried, battery operated device, supply the EUT primary voltage with 85
          and 115 percent of the nominal value and record the frequency.



                        Figure 5 : Frequency stability measurement configuration


                           Temperature Chamber



                       Spectrum
                       Analyzer




                                                                     DC
                                                                 Power Supply




   7.3 Measurement Instrument


          Equipment               Manufacturer    Model No.     Calibration Date Next Cal. Date
     Spectrum Analyzer        Rohde & Schwarz FSP40              2008/09/11            2009/09/11
     Temperature Chamber      MALLIER            MCT-2X-M        2007/12/07            2008/12/06




                                                                                                 Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                  Sheet 28 of 31 Sheets
                                                                                 FCC ID.: INGIN64TH


   7.4 Measurement Data
          A. Channel Low
          A1. Frequency stability versus enviroment tempture

      Reference Frequency :502 MHz                     Limit:0.005%
      Enviroment    Power      Frequency measured with time elapsed
      Tempture     Supplied           2 minute                5 minute               10 minute
         (℃)         (Vac)      (MHz)         (%)          (MHz)         (%)     (MHz)         (%)
          50                   502.0015     0.00030       502.0011    0.00022   502.0014     0.00028
          40                   502.0008     0.00016       502.0007    0.00014   502.0008     0.00016
          30                   502.0011     0.00022       502.0015    0.00030   502.0014     0.00028
          20       New Batt.   502.0001     0.00002       502.0004    0.00008   502.0004     0.00008
          10                   502.0007     0.00014       502.0005    0.00010   502.0010     0.00020
           0                   502.0015     0.00030       502.0014    0.00028   502.0013     0.00026
         -10                   502.0018     0.00036       502.0013    0.00026   502.0014     0.00028
         -20                   502.0019     0.00038       502.0018    0.00036   502.0017     0.00034
         -30                   502.0011     0.00022       502.0015    0.00030   502.0014     0.00028

          A2. Frequency stability versus supplied voltage (85% - 115%)

      Reference Frequency : 502 MHz                    Limit:0.005%
      Enviroment     Power      Frequency measured with time elapsed
      Tempture      Supplied          2 minute                5 minute              10 minute
         (℃)         (Vac)         (MHz)         (%)       (MHz)         (%)     (MHz)           (%)
          25       End-Point   502.0008     0.00016       502.0005    0.00010   502.0007     0.00014




                                                                                                  Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                  Sheet 29 of 31 Sheets
                                                                                 FCC ID.: INGIN64TH




          B. Channel Middle
          B1. Frequency stability versus enviroment tempture

      Reference Frequency : 600 MHz                    Limit:0.005%
      Enviroment    Power      Frequency measured with time elapsed
      Tempture     Supplied           2 minute                5 minute               10 minute
         (℃)         (Vac)      (MHz)         (%)          (MHz)         (%)     (MHz)         (%)
          50                   600.0015     0.00025       600.0014    0.00023   600.0013     0.00022
          40                   600.0014     0.00023       600.0013    0.00022   600.0014     0.00023
          30                   600.0010     0.00017       600.0010    0.00017   600.0011     0.00018
          20       New Batt.   600.0008     0.00013       600.0007    0.00012   600.0070     0.00117
          10                   600.0009     0.00015       600.0005    0.00008   600.0009     0.00015
           0                   600.0015     0.00025       600.0014    0.00023   600.0013     0.00022
         -10                   600.0018     0.00030       600.0015    0.00025   600.0014     0.00023
         -20                   600.0015     0.00025       600.0019    0.00032   600.0017     0.00028
         -30                   600.0017     0.00028       600.0015    0.00025   600.0015     0.00025

          B2. Frequency stability versus supplied voltage (85% - 115%)

      Reference Frequency : 600 MHz                    Limit:0.005%
      Enviroment     Power      Frequency measured with time elapsed
      Tempture      Supplied          2 minute                5 minute              10 minute
         (℃)         (Vac)         (MHz)         (%)       (MHz)         (%)     (MHz)           (%)
          25       End-Point   600.0003     0.00005       600.0002    0.00003   600.0008     0.00013




                                                                                                  Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                                 Sheet 30 of 31 Sheets
                                                                                FCC ID.: INGIN64TH




          C. Channel High
          C1. Frequency stability versus enviroment tempture

      Reference Frequency : 697.875 MHz               Limit:0.005%
      Enviroment    Power      Frequency measured with time elapsed
      Tempture     Supplied          2 minute                5 minute               10 minute
         (℃)         (Vac)      (MHz)        (%)          (MHz)         (%)     (MHz)         (%)
          50                   697.8759    0.00013       697.8758    0.00011   697.8755     0.00007
          40                   697.8761    0.00016       697.8762    0.00017   697.8763     0.00019
          30                   697.8762    0.00017       697.8763    0.00019   697.8764     0.00020
          20       New Batt.   697.8755    0.00007       697.8754    0.00006   697.8763     0.00019
          10                   697.8754    0.00006       697.8755    0.00007   697.8759     0.00013
           0                   697.8762    0.00017       697.8764    0.00020   697.8764     0.00020
         -10                   697.8760    0.00014       697.8762    0.00017   697.8768     0.00026
         -20                   697.8764    0.00020       697.8763    0.00019   697.8769     0.00027
         -30                   697.8764    0.00020       697.8769    0.00027   697.8764     0.00020

          C2. Frequency stability versus supplied voltage (85% - 115%)

      Reference Frequency : 697.875 MHz               Limit:0.005%
      Enviroment    Power      Frequency measured with time elapsed
      Tempture     Supplied         2 minute                 5 minute              10 minute
         (℃)         (Vac)      (MHz)           (%)       (MHz)         (%)     (MHz)           (%)
          25       End-oint    697.8752    0.00003       697.8754    0.00006   697.8753     0.00004




                                                                                                 Rev. 2.0


ETC Report No.:08-09-RBF-067-001                                           Sheet 31 of 31 Sheets
                                                                          FCC ID.: INGIN64TH



8 CONDUCTED EMISSION MEASUREMENT
   8.1 Standard Applicable
       This EUT is excused from investigation of conducted emission, for it is powered by DC
       battery only. According to §15.207 (d), measurements to demonstrate compliance with
       the conducted limits are not required for devices which only employ battery power for
       operation and which do not operate from the AC power lines or contain provisions for
       operation while connected to the AC power lines.




                                                                                           Rev. 2.0



Document Created: 2008-12-15 15:24:23
Document Modified: 2008-12-15 15:24:23

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC