RF exposure Info

FCC ID: IKQMCQ

RF Exposure Info

Download: PDF
FCCID_4481414

                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch




                                                                    Report No.: SZEM190301164302
                                                                    Page:        1 of 13

COVER PAGE

                      Human Exposure Report
Application No.:          SZEM1903011643CR
Applicant:                Scosche Industries Inc.
Address of Applicant:     1550 Pacific Ave, Oxnard, CA93033, USA
Manufacturer:             Scosche Industries Inc.
Address of Manufacturer:  1550 Pacific Ave, Oxnard, CA93033, USA
Factory:                  Scosche Industries Inc.
Address of Factory:       1550 Pacific Ave, Oxnard, CA93033, USA
Equipment Under Test (EUT):
EUT Name:                 Wireless car charger
Model No.:                MCQ, MCQVP, MCQD, MCQWDDP, MCQWD, MCQXX-XX (XX can be A-Z
                          or 0-9) ♣
                          Please refer to section 1.2 of this report which indicates which model was
                          actually tested and which were electrically identical.
Trade Mark:               SCOSCHE
FCC ID:                   IKQMCQ
Standards:                47 CFR PART 1, SUBPART I, SECTION 1.1310
Date of Receipt:          2019-08-13
Date of Test:                  2019-08-13 TO 2019-08-16
Date of Issue:                 2019-08-20
Test Result :                   Pass*

* In the configuration tested, the EUT complied with the standards specified above.




       Keny Xu
EMC Laboratory Manager




             Keny Xu
      EMC Laboratory Manager


                                                        SGS—CSTC Standards Technical Services Co., Ltd.
                                                        Shenzhen Branch

                                                                                                                                   Report No.: SZEM190301164302
                                                                                                                                   Page:        2 of 13


Contents
                                                                                                                                                                                                   Page




    2.1      DETAILSOFE.U.T . ..22222222l22220222222rrsreerrsreerrsreerrserrsreerrsseeceeseeceeseeceeseeceeseeceeseecseseeceseecceseecceseecces ce ce es ce cc es ce ca es ce caees 3
    2.2       DESCRIPTION OF SUPPORT UNITS......2222.222ll2222l00er0sseerrsreersreee es esc es ce ces eeeeeseeeeeceseeseeeeeseeceeseeceeseecees ce ce eseecc es ce caees 3
    2.3      TEST LOCATION....2.l2lllll2llll222rrrreerrsreerrsreerrsreeceeeersseeeeeseeseeseeeeeseeeeeseeeeeseeeeeseeeeeseeccesecceseecceseeccesceccescecceseecc es ce ca ces 4
    2.4      TEST FACILITY....2.2222lll2020ll2220rrrreerrsreerrsreerrsreeeeee es eeeeeseeseeseeeeeseeceeseeeeeseeeeeseeeeeseecenececceseecceseeccescecceseecceseecc es ce ca ces 4
    2.5      DEVIATIONFROM STANDARDS........222222222022llllrrserrrrsrereeeesrsrsreseeeesessseeseeeeseesessseee sc es es eeee cce ec es se cesc es en es se ce se es cce ees 5
    2.6      ABNORMALITIES FROM STANDARD CONDITIONS...2222222222222122022202er00treeeeeerr66 se se se ce es se se se ce es se es se ce se es en en se ce se es e en ee s 5

3         EQUIPMENTS USED DURING TEST ..22220000000sssssssssereccecccerceceseccccccescccercccescccccccesccccsccccccccsccccscccccccccccccccccccces 0



    4.1      RF EXPOSURE TEST ...........l.l.llll.l.llllllrrcerrrreerrsreereseersseesesseesesseeeesseeessseecesseecssseeecsseecesseecesseecceseecceseecces ce ce es ce ca es ce caees 7
          4.1.1       E.U.T. ODBYAIHIONM......020020000000000000ssvrssrssrssssessrssrrssessessersssesessereseesessere se es es se es s es es es se ns se es es se cssn as es se cssn es en se en s 7
          4.1.2       Me@ASU@M@Nt D@IQ...................0220000000000000022rrrrrrsesseerrrrereeeeeeeeerereeeseeeeeeeeeee es es es es se es en eree es se es en e se se esns en en 8

5         PHOTOGRAPHS— TEST PHOTOS....2200000000sssss0seereeceseccccccersercesescccccescrccscrccscsccccccscsccscsccccccsccccccccccccccccccccsccee 13




                                         Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                         overleaf, available on request or accessible at http://www.sgs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                         subject to Terms and Conditions for Electronic Documents at http://www.sqs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                                         Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                         advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                         Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                         transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                         except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                                         appearance of this document is unlawful and offenders may be prosecuted to the fullest extent         the law. Unless otherwise stated the
                                         results shown in this test report refer onl¥ to the sample(s) tested and such sample(s) are retained for 30 days only.
                                         Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone (86—755) 8307 1443,
                                         or email: CN.Doccheck@sgs.com
                                   . Ltd. No.1 Workshop, M—10, Middle Section, Science & Technology Park, Shenzhen, China 518057   t (86—755) 26012053 f (86—755) 26710594   www.sgsgroup.com.cn
                                             4B —Ril— NKRAFEM—10OKR—SJB                                        B&E: 518057         t (86—755) 26012053 f (86—755) 26710594   sgs.china@sgs.com
                                         I
                                                                                                                                                      Member of the SGS Group (SGS SA)


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                  Report No.: SZEM190301164302
                                                                  Page:       3 of 13



1     General Information
1.1 Details of E.U.T.
      Power supply:              Input: DC 5V, 2A or DC 9V, 1.67A
                                 Output: 5W, 7.5W, 10W
                                 Car Charge,
                                 Model: CQA8
                                 Input: DC 12V
                                 Output: DC 3.6-6.5V, 3.0A
                                          DC 6.5-9V, 2.0A
                                          DC 9-12V, 1.5A
      Cable:                     USB Cable: 150cm, Unshielded
      Operation frequency:       123.462kHz to 205.192kHz
      Modulation type:           Load modulation
      Antenna type:              Loop Coil Antenna
      Antenna Gain:              0dBi
      Remark:                    Tests were conducted in all three load modes and the worst case 10W(DC
                                 9V, 1.67A) is reported only.

1.2 Description of Support Units
      Description                 Manufacturer                  Model No.                Serial No.
      iPhone 8                          Apple                     A1863               F4GVQ656JC6D
      Mobile Phone                  SAMSUNG                     SM-G9500                R28J9140LPB


Declaration of EUT Family Grouping:
Model No.: MCQ, MCQVP, MCQD, MCQWDDP, MCQWD, MCQXX-XX (XX can be A-Z or 0-9)
Only the model MCQ was tested, since the electrical circuit design, layout, components used, internal wiring
and functions were identical for all the above models, with only difference on package and car mount type.


                     5                                   SGS—CSTC Standards Technical Services Co., Ltd.
                                                         Shenzhen Branch

                                                                                                                                   Report No.: SZEM190301164302
                                                                                                                                   Page:       4 of 13




1.3     Test Location
        All tests were performed at:
        SGS—CSTC Standards Technical Services Co., Ltd., Shenzhen Branch
        No. 1 Workshop, M—10, Middle Section, Science & Technology Park, Shenzhen, Guangdong, China.
        518057.
        Tel: +86 755 2601 2053                                      Fax: +86 755 2671 0594
            No tests were sub—contracted.

1.4     Test Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        * CNAS (No. CNAS L2929)
        CNAS has accredited SGS—CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
        Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
        Laboratories (CNAS—CLO1 Accreditation Criteria for the Competence of Testing and Calibration
        Laboratories) for the competence in the field of testing.
        * A2LA (Certificate No. 3816.01)
        SGS—CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
        American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
        * VCCI
        The 3m Fully—anechoic chamber for above 1GHz, 10m Semi—anechoic chamber for below 1GHz,
        Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
        Conducted Interference Measurement of SGS—CSTC Standards Technical Services Co., Ltd. have
        been registered in accordance with the Regulations for Voluntary Control Measures with Registration
        No.: G—20026, R—14188, C—12383 and T—11153 respectively.
        * FCC —Designation Number: CN1178
        SGS—CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
        as an accredited testing laboratory.
        Designation Number: CN1178. Test Firm Registration Number: 406779.
        *     Innovation, Science and Economic Development Canada
        SGS—CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
        by ISED as an accredited testing laboratory.
        CAB identifier: CNOOO6.
        IC#: 4620C.




                                          Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                          overleaf, available on request or accessible at http://www.sgs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                          subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                                          Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                          advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                          Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                          transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                          except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
                                          appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                                          results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                                          Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443,
                                          or email: CN.Doccheck@sgs.com
                     ica effigef Co. Ltd. No.1 Workshop, M—10, Middle Section, Science & Technology Park, Shenzhen, China 518057   t (86—755) 26012053 f (86—755) 26710594   www.sgsgroup.com.cn
Shenzhen Brantésl@ EBE mE    aboratory.     41B ~Ril— AKRAFEM—10K—SJB                                              BB&@: 518057    t (86—755) 26012053 f (86—755) 26710594   sgs.china@sgs.com
                                          T
                                                                                                                                                      Member of the SGS Group (SGS SA)


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Shenzhen Branch
                                             Report No.: SZEM190301164302
                                             Page:       5 of 13




1.5 Deviation from Standards
    None.

1.6 Abnormalities from Standard Conditions
    None.


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                     Report No.: SZEM190301164302
                                                     Page:       6 of 13




2   Equipments Used during Test

                                                          Inventory   Cal. Due date
    Item   Test Equipment     Manufacturer   Model No.
                                                             No.       (yyyy-mm-dd)

           3m Semi-Anechoic
     1                        ETS-LINDGREN     N/A        SEL0017      2020-06-10
               Chamber
             Electric and
     2      Magnetic Field       Narda       EHP-50F      EMC092       2020-05-06
              Analyzer


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                  Report No.: SZEM190301164302
                                                                  Page:       7 of 13



3     Test Results
3.1 RF Exposure test
      Test Requirement:               47 CFR PART 1, Subpart I, Section 1.1310
      Measurement Distance:           0-15cm
      Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                            (A) Limits for Occupational/Controlled Exposures
         0.3-3.0                614                      1.63                *(100)             6
          3.0-30               1842/f                    4.89/f            *(900/f 2)           6
         30-300                 61.4                     0.163                1.0               6
        300-1500                  /                        /                 f/300              6
      1500-100,000                /                        /                     5              6
                        (B) Limits for General Population/Uncontrolled Exposure
         0.3-1.34               614                      1.63                *(100)            30
         1.34-30                824/f                    2.19/f            *(180/f 2)          30
         30-300                 27.5                     0.073                0.2              30
        300-1500                  /                        /                f/1500             30
      1500-100,000                /                        /                  1.0              30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC
    rules. The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits
    for 150kHz:614V/m,1.63A/m).
3.1.1 E.U.T. Operation

      Operating Environment:
      Temperature:     25.0 °C            Humidity:   51 % RH         Atmospheric Pressure: 1015 mbar

       EUT Operation:
      This device has been tested with mobile phone at zero charge, intermediate charge, and full
       charge.


                                SGS-CSTC Standards Technical Services Co., Ltd.
                                Shenzhen Branch
                                                           Report No.: SZEM190301164302
                                                           Page:       8 of 13



3.1.2   Measurement Data




        Mobile phone has been charge at zero charge, intermediate charge, and full charge.
        Electric Field Emissions

         Operation       Test                     Probe Measure Result(V/m)
                                      Test                                         50%Limit
         frequency     Distance
                                     Position    zero    intermediate     full
                                                charge      charge      charge      (V/m)
                           (cm)
                                      Side 1     2.97        2.71         2.16       307
                                      Side 2     4.87        4.63         4.18       307
           125kHz           0         Side 3     3.71        3.36         2.82       307
                                      Side 4     8.28        7.94         7.42       307
                                       Top       2.74        2.44         1.95       307


        Magnetic Field Emissions

         Operation       Test                     Probe Measure Result(A/m)
                                      Test                                         50%Limit
         frequency     Distance
                                     Position   zero     intermediate   full
                                                charge      charge      charge      (A/m)
                           (cm)
                                      Side 1    0.5066      0.4793       0.4187     0.815
                                      Side 2    0.7244      0.6963       0.6312     0.815
          125 kHz           0         Side 3    0.7006      0.6785       0.6189     0.815
                                      Side 4    0.7064       0.678       0.6159     0.815
                                       Top      0.3884      0.3607       0.2987     0.815


                       SGS-CSTC Standards Technical Services Co., Ltd.
                       Shenzhen Branch
                                                  Report No.: SZEM190301164302
                                                  Page:       9 of 13



Electric Field Emissions

 Operation       Test                    Probe Measure Result(V/m)
                             Test                                       50%Limit
 frequency     Distance
                            Position    zero    intermediate     full
                                       charge      charge      charge    (V/m)
                  (cm)
                             Side 1     2.63        2.37        1.99      307
                             Side 2     4.63        4.31        3.86      307
   125kHz          2         Side 3     3.44        3.28        2.75      307
                             Side 4     6.71        6.42        5.87      307
                              Top       2.47        2.19        1.73      307


Magnetic Field Emissions

 Operation       Test                    Probe Measure Result(A/m)
                             Test                                       50%Limit
 frequency     Distance
                            Position   zero     intermediate   full
                                       charge      charge      charge    (A/m)
                  (cm)
                             Side 1                                      0.815
                                       0.4952      0.4678      0.4033
                             Side 2                                      0.815
                                       0.7028      0.6767      0.6219
  125 kHz          2         Side 3                                      0.815
                                       0.6865      0.6643      0.6128
                             Side 4                                      0.815
                                       0.6831      0.6525      0.5979
                              Top                                        0.815
                                       0.3641      0.3359      0.2823

Electric Field Emissions

 Operation       Test                    Probe Measure Result(V/m)
                             Test                                       50%Limit
 frequency     Distance
                            Position    zero    intermediate     full
                                       charge      charge      charge    (V/m)
                  (cm)
                             Side 1     2.29        2.08        1.62      307
                             Side 2     4.24        3.85        3.31      307
   125kHz          4         Side 3     3.14        2.82        2.44      307
                             Side 4     5.54        5.35        4.99      307
                              Top       2.28        1.98        1.57      307


                       SGS-CSTC Standards Technical Services Co., Ltd.
                       Shenzhen Branch
                                                  Report No.: SZEM190301164302
                                                  Page:       10 of 13



Magnetic Field Emissions

 Operation       Test                    Probe Measure Result(A/m)
                             Test                                       50%Limit
 frequency     Distance
                            Position   zero     intermediate   full
                                       charge      charge      charge    (A/m)
                  (cm)
                             Side 1                                      0.815
                                       0.4763      0.4474      0.3911
                             Side 2                                      0.815
                                       0.6905      0.6613      0.6012
  125 kHz          4         Side 3                                      0.815
                                       0.6674      0.6362      0.5776
                             Side 4                                      0.815
                                       0.6773      0.6482      0.5938
                              Top                                        0.815
                                       0.3402      0.3149      0.2585

Electric Field Emissions

 Operation       Test                    Probe Measure Result(V/m)
                             Test                                       50%Limit
 frequency     Distance
                            Position    zero    intermediate     full
                                       charge      charge      charge    (V/m)
                  (cm)
                             Side 1     2.15        1.71        1.19      307
                             Side 2     4.02        3.72        3.21      307
   125kHz          6         Side 3     2.85        2.54        2.08      307
                             Side 4     4.63        4.25        3.68      307
                              Top       1.98        1.68        1.23      307


                       SGS-CSTC Standards Technical Services Co., Ltd.
                       Shenzhen Branch
                                                  Report No.: SZEM190301164302
                                                  Page:       11 of 13



Magnetic Field Emissions

 Operation       Test                    Probe Measure Result(A/m)
                             Test                                       50%Limit
 frequency     Distance
                            Position   zero     intermediate   full
                                       charge      charge      charge    (A/m)
                  (cm)
                             Side 1                                      0.815
                                       0.4626      0.4374      0.3873
                             Side 2                                      0.815
                                       0.6681      0.6457      0.5996
  125 kHz          6         Side 3                                      0.815
                                       0.6562      0.6282      0.5664
                             Side 4                                      0.815
                                       0.6554      0.6249      0.5594
                              Top                                        0.815
                                       0.3354      0.3113      0.2641

Electric Field Emissions

 Operation       Test                    Probe Measure Result(V/m)
                             Test                                       50%Limit
 frequency     Distance
                            Position    zero    intermediate     full
                                       charge      charge      charge    (V/m)
                  (cm)
                             Side 1     1.46        1.15        0.59      307
                             Side 2     3.52        3.15        2.64      307
   125kHz          8         Side 3     2.23        1.93        1.51      307
                             Side 4     3.51        3.16        2.67      307
                              Top       1.28        0.91        0.46      307


Magnetic Field Emissions

 Operation       Test                    Probe Measure Result(A/m)
                             Test                                       50%Limit
 frequency     Distance
                            Position   zero     intermediate   full
                                       charge      charge      charge    (A/m)
                  (cm)
                             Side 1                                      0.815
                                       0.4546      0.4321      0.3856
                             Side 2                                      0.815
                                       0.6689      0.6417      0.5815
  125 kHz          8         Side 3                                      0.815
                                       0.6426      0.6185      0.5648
                             Side 4                                      0.815
                                       0.6345      0.6048      0.5482
                              Top                                        0.815
                                       0.3286      0.3063      0.2496


                     SGS-CSTC Standards Technical Services Co., Ltd.
                     Shenzhen Branch
                                                 Report No.: SZEM190301164302
                                                 Page:       12 of 13


Electric Field Emissions

 Operation       Test                   Probe Measure Result(V/m)
                            Test                                       50%Limit
 frequency     Distance
                           Position    zero    intermediate     full
                                      charge      charge      charge    (V/m)
                  (cm)
                            Side 1     1.14        0.75        0.28      307
                            Side 2     3.04        2.83        2.42      307
   125kHz          10       Side 3     1.85        1.52        1.11      307
                            Side 4     2.63        2.38        1.85      307
                             Top       1.12        0.84        0.38      307


Magnetic Field Emissions

 Operation       Test                   Probe Measure Result(A/m)
                            Test                                       50%Limit
 frequency     Distance
                           Position   zero     intermediate   full
                                      charge      charge      charge    (A/m)
                  (cm)
                            Side 1                                      0.815
                                      0.4315      0.4062      0.3424
                            Side 2                                      0.815
                                      0.6418      0.6178      0.5643
  125 kHz          10       Side 3                                      0.815
                                      0.6102      0.5861      0.5365
                            Side 4                                      0.815
                                      0.6347      0.6034      0.5568
                             Top                                        0.815
                                      0.3107      0.2788      0.2272

Electric Field Emissions

 Operation       Test                   Probe Measure Result(V/m)
                            Test                                       50%Limit
 frequency     Distance
                           Position    zero    intermediate     full
                                      charge      charge      charge    (V/m)
                  (cm)
                            Side 1     0.61        0.49        0.13      307
                            Side 2     2.77        2.51        2.04      307
   125kHz          15       Side 3     1.22        0.92        0.51      307
                            Side 4     1.87        1.51        1.09      307
                             Top       0.56        0.35        0.08      307


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Shenzhen Branch
                                                          Report No.: SZEM190301164302
                                                          Page:       13 of 13



     Magnetic Field Emissions

      Operation      Test                     Probe Measure Result(A/m)
                                 Test                                         50%Limit
      frequency    Distance
                                Position   zero       intermediate   full
                                           charge        charge      charge    (A/m)
                     (cm)
                                 Side 1     0.4084        0.3798     0.3337    0.815
                                 Side 2     0.6078        0.5781     0.5313    0.815
       125 kHz         15        Side 3     0.5757        0.5481     0.4908    0.815
                                 Side 4     0.5964        0.5714     0.5137    0.815
                                  Top       0.2742        0.2478     0.1859    0.815




4   Photographs- Test photos
    Refer to test RF exposure setup photos.



                                  - End of the Report -



Document Created: 2019-10-15 08:53:49